Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source code (Computer science)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CDAC Student Report: Summary of LLNL Internship

Multiple objectives motivated me to apply for an internship at LLNL: I wanted to experience the work environment at a national lab, to learn about research and job opportunities at LLNL in particular, and to gain greater experience with code development, particularly within the realm of high performance computing (HPC). This summer I was selected to participate in LLNL's Computational Chemistry and Material Science Summer Institute (CCMS). CCMS is a 10 week program hosted by the Quantum Simulations group leader, Dr. Eric Schwegler. CCMS connects graduate students to mentors at LLNL involved in similar re- search and provides weekly seminars on a broad array of topics from within chemistry and materials science. Dr. Xavier Andrade and Dr. Erik Draeger served as my co-mentors over the summer, and Dr. Andrade continues to mentor me now that CCMS has concluded. Dr. Andrade is a member of the Quantum Simulations group within the Physical and Life Sciences at LLNL, and Dr. Draeger leads the HPC group within the Center for Applied Scientific Computing (CASC). The two have worked together to develop Qb@ll, an open-source first principles molecular dynamics code that was the platform for my summer research project.

36 MATERIALS SCIENCE↗

SU-E-T-204: Improving Multiple Isocenter Coincidence: Elekta Beam Modulator with HexaPOD Six Degrees Couchtop

Purpose: With evolution from frame-based to image-guided SRS/SRT technique, the coincidence of multiple isocenters must be within a tight tolerance: MV, kV, table mechanical, and, in this case, HexaPOD 6° patient positioning system. Reported here is a method for improving the effectiveness of an isocenter alignment procedure which ultimately led to isocenter coincidence on an Elekta Beam Modulator LINAC equipped with 4 mm MLC leaves and a fixed secondary jaw to within a radius of 1mm. Methods: Utilizing a self-leveling laser, the Elekta ball (BB) bearing phantom (8mm steel ball), the Modus QA Isocenter Cube software, and a colleague-provided isocenter alignment method, the kV, table mechanical, and HexaPOD isocenters were localized to the MV isocenter. Isocenter coincidence was tested using the Isocenter Cube from Modus QA, brought to kV isocenter using CBCT and the HexaPOD system. MV images were taken at various gantry, collimator, and couch angles and then analyzed with the aforementioned software to determine coincidence of the 5mm steel ball at cube center with MV isocenter. To improve overall coincidence, two errors were addressed iteratively: (1) LINAC mechanical and radiation isocenter coincidence allowing each isocenter volume to have similar variations during gantry and collimator rotation and (2) collimator rotational walkout which reduced the size of both mechanical and radiation isocenters. Beam steering was performed to bring MV isocenter closer to mechanical and collimator walkout was adjusted by physically shifting the MLC bank. Initial procedures were repeated to align all isocenters and perform regular checks for consistency. Results: Post-initial alignment revealed a maximum diameter of 1.8mm for MV isocenter and maximum isocenter alignment error of up to 1.22mm radius which improved to roughly 1.0mm MV isocenter diameter and <0.71mm radius alignment error with a consistency within 0.25mm. Conclusion: With the methods described, all isocenters were brought into alignment within a radius of 1mm.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-348: Verification MU Calculation for Conformal Radiotherapy with Multileaf Collimator Using Report AAPM TG 114

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for 3D conformal radiotherapy with multileaf high and low resolution according to the report of AAPM TG 11 Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS. A 6MV photon beam produced by Primus and Novalis linear accelerators equipped with an Optifocus MLC and HDMLC, respectively. TPS dose calculation algorithms were pencil beam and Monte Carlo. 1082 treatments plans were selected for the study. The algorithm was written in free and open source CodeBlocks C++ platform. Treatment plans were imported by the software using RTP format. Equivalent size field is obtained from the positions of the leaves; the effective depth of calculation can be introduced by TPS's dosimetry report or automatically calculated starting from SSD. The inverse square law is calculated by the 3D coordinates of the isocenter and normalization point of the treatment plan. The dosimetric parameters TPR, Sc, Sp and WF are linearly interpolated. Results: 1082 plans of both machines were analyzed. The average uncertainty between the TPS and the independent calculation was −0.43% ± 2.42% [−7.90%, 7.50%]. Specifically for the Primus the variation obtained was −0.85% ± 2.53% and for the Novalis 0.00% ± 2.23%. Data show that 94.8% of the cases the uncertainty was less than or equal to 5%, while 98.9% is less than or equal to 6%. Conclusion: The developed software is appropriate for use in calculation of UM. This software can be obtained upon request.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-373: A Motorized Stage for Fast and Accurate QA of Machine Isocenter

Purpose: Precision delivery of radiation dose relies on accurate knowledge of the machine isocenter under a variety of machine motions. This is typically determined by performing a Winston-Lutz test consisting of imaging a known object at multiple gantry/collimator/table angles and ensuring that the maximum offset is within specified tolerance. The first step in the Winston-Lutz test is careful placement of a ball bearing at the machine isocenter as determined by repeated imaging and shifting until accurate placement has been determined. Conventionally this is performed by adjusting a stage manually using vernier scales which carry the limitation that each adjustment must be done inside the treatment room with the risks of inaccurate adjustment of the scale and physical bumping of the table. It is proposed to use a motorized system controlled outside of the room to improve the required time and accuracy of these tests. Methods: The three dimensional vernier scales are replaced by three motors with accuracy of 1 micron and a range of 25.4mm connected via USB to a computer in the control room. Software is designed which automatically detects the motors and assigns them to proper axes and allows for small shifts to be entered and performed. Input values match calculated offsets in magnitude and sign to reduce conversion errors. Speed of setup, number of iterations to setup, and accuracy of final placement are assessed. Results: Automatic BB placement required 2.25 iterations and 13 minutes on average while manual placement required 3.76 iterations and 37.5 minutes. The average final XYZ offsets is 0.02cm, 0.01cm, 0.04cm for automatic setup and 0.04cm, 0.02cm, 0.04cm for manual setup. Conclusion: Automatic placement decreased time and repeat iterations for setup while improving placement accuracy. Automatic placement greatly reduces the time required to perform QA.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-JeP3-10: Update On a Real-Time Treatment Guidance System Using An IR Navigation System for Pleural PDT

Purpose: Photodynamic therapy (PDT) is used in conjunction with surgical debulking of tumorous tissue during treatment for pleural mesothelioma. One of the key components of effective PDT is uniform light distribution. Currently, light is monitored with 8 isotropic light detectors that are placed at specific locations inside the pleural cavity. A tracking system with real-time feedback software can be utilized to improve the uniformity of light in addition to the existing detectors. Methods: An infrared (IR) tracking camera is used to monitor the movement of the light source. The same system determines the pleural geometry of the treatment area. Software upgrades allow visualization of the pleural cavity as a two-dimensional volume. The treatment delivery wand was upgraded for ease of light delivery while incorporating the IR system. Isotropic detector locations are also displayed. Data from the tracking system is used to calculate the light fluence rate delivered. This data is also compared with in vivo data collected via the isotropic detectors. Furthermore, treatment volume information will be used to form light dose volume histograms of the pleural cavity. Results: In a phantom study, the light distribution was improved by using real-time guidance compared to the distribution when using detectors without guidance. With the tracking system, 2D data can be collected regarding light fluence rather than just the 8 discrete locations inside the pleural cavity. Light fluence distribution on the entire cavity can be calculated at every time in the treatment. Conclusion: The IR camera has been used successfully during pleural PDT patient treatment to track the motion of the light source and provide real-time display of 2D light fluence. It is possible to use the feedback system to deliver a more uniform dose of light throughout the pleural cavity.

60 APPLIED LIFE SCIENCES↗

SU-D-213-05: Design, Evaluation and First Applications of a Off-Site State-Of-The-Art 3D Dosimetry System

Purpose: To design, construct and commission a prototype in-house three dimensional (3D) dose verification system for stereotatic body radiotherapy (SBRT) verification at an off-site partner institution. To investigate the potential of this system to achieve sufficient performance (1mm resolution, 3% noise, within 3% of true dose reading) for SBRT verification. Methods: The system was designed utilizing a parallel ray geometry instigated by precision telecentric lenses and an LED 630nm light source. Using a radiochromic dosimeter, a 3D dosimetric comparison with our gold-standard system and treatment planning software (Eclipse) was done for a four-field box treatment, under gamma passing criteria of 3%/3mm/10% dose threshold. Post off-site installation, deviations in the system’s dose readout performance was assessed by rescanning the four-field box irradiated dosimeter and using line-profiles to compare on-site and off-site mean and noise levels in four distinct dose regions. As a final step, an end-to-end test of the system was completed at the off-site location, including CT-simulation, irradiation of the dosimeter and a 3D dosimetric comparison of the planned (Pinnacle{sup 3}) to delivered dose for a spinal SBRT treatment(12 Gy per fraction). Results: The noise level in the high and medium dose regions of the four field box treatment was relatively 5% pre and post installation. This reflects the reduction in positional uncertainty through the new design. This At 1mm dose voxels, the gamma pass rates(3%,3mm) for our in-house gold standard system and the off-site system were comparable at 95.8% and 93.2% respectively. Conclusion: This work will describe the end-to-end process and results of designing, installing, and commissioning a state-of-the-art 3D dosimetry system created for verification of advanced radiation treatments including spinal radiosurgery.

60 APPLIED LIFE SCIENCES↗

SU-E-T-128: Dosimetric Evaluation of MLC Modeling in Pinnacle V9.2 for Varian TrueBeam STx

Purpose: To evaluate the effects of MLC modeling after commissioning the Varian TrueBeam LINAC in Pinnacle version 9.2. Methods: Stepand-shoot IMRT QAs were investigated when we observed our measured absolute dose results using ion chamber (Capintec PR-05P) were uncharacteristically low; about 4–5% compared to doses calculated by Pinnacle{sup 3} (Phillips, Madison, WI). This problem was predominant for large and highly modulated head and neck (HN) treatments. Intuitively we knew this had to be related to shortcomings in the MLC modeling in Pinnacle. Using film QA we were able to iteratively adjust the MLC parameters. We confirmed results by re-testing five failed IMRT QA patients; and ion chamber measurements were verified in Quasar anthropomorphic phantom. Results: After commissioning the LINAC in Pinnacle version 9.2, the MLC transmission for 6X, 10X and 15X were 2.0%, 1.7% and 2.0%, respectively, and additional Interleaf leakage for all three energies was 0.5%. These parameters were obtained from profiles scanned with an Edge detector (Sun Nuclear, Melbourne, FL) during machine commissioning. A Verification testing with radiographic EDR2 film (Kodak, Rochester, NY) measurement was performed by creating a closed MLC leaf pattern and analyzing using RIT software (RIT, Colorado Springs, CO). This reduced MLC transmission for 6X, 10X and 15X to 0.7%, 0.9% and 0.9%, respectively; while increasing additional Interleaf leakage for all three energies to 1.0%. Conclusion: Radiographic film measurements were used to correct MLC transmission values for step and shoot IMRT fields used in Pinnacle version 9.2. After adjusting the MLC parameters to correlate with the film QA, there was still very good agreement between the Pinnacle model and commissioning data. Using the same QA methodology, we were also able to improve the beam models for the Varian C-series linacs, Novalis-Tx, and TrueBeam M-120 linacs.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-P-05: Electronic Brachytherapy: A Physics Perspective On Field Implementation

Purpose: We want to summarize our experience implementing a successful program of electronic brachytherapy at several dermatology clinics with the help of a cloud based software to help us define the key program parameters and capture physics QA aspects. Optimally developed software helps the physicist in peer review and qualify the physical parameters. Methods: Using the XOFT™ Axxent™ electronic brachytherapy system in conjunction with a cloud-based software, a process was setup to capture and record treatments. It was implemented initially at about 10 sites in California. For dosimetric purposes, the software facilitated storage of the physics parameters of surface applicators used in treatment and other source calibration parameters. In addition, the patient prescription, pathology and other setup considerations were input by radiation oncologist and the therapist. This facilitated physics planning of the treatment parameters and also independent check of the dwell time. From 2013–2014, nearly1500 such calculation were completed by a group of physicists. A total of 800 patients with multiple lesions have been treated successfully during this period. The treatment log files have been uploaded and documented in the software which facilitated physics peer review of treatments per the standards in place by AAPM and ACR. Results: The program model was implemented successfully at multiple sites. The cloud based software allowed for proper peer review and compliance of the program at 10 clinical sites. Dosimtery was done on 800 patients and executed in a timely fashion to suit the clinical needs. Accumulated physics data in the software from the clinics allows for robust analysis and future development. Conclusion: Electronic brachytherapy implementation experience from a quality assurance perspective was greatly enhanced by using a cloud based software. The comprehensive database will pave the way for future developments to yield superior physics outcomes.

07 ISOTOPE AND RADIATION SOURCES↗

Kokkos v.4.0

SAND2023-07883O Kokkos software implements C++ performance portability programming models, tools and math libraries, which enables science and engineering software developers to use single-source codes for a wide range of computer architectures. Kokkos also provides implementations of existing and proposed C++ standard features that support programming model and math libraries that are used for implementing performance-portable scientific and engineering applications. The Kokkos libraries provide algorithms, data structures, and tools to enable high-performance computing developers to write performance-portable code. Capabilities fall into three broad categories: Kokkos Core, Kokkos Kernels, and Kokkos Tools. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

WE-DE-201-12: Thermal and Dosimetric Properties of a Ferrite-Based Thermo-Brachytherapy Seed

Purpose: The novel thermo-brachytherapy (TB) seed provides a simple means of adding hyperthermia to LDR prostate permanent implant brachytherapy. The high blood perfusion rate (BPR) within the prostate motivates the use of the ferrite and conductive outer layer design for the seed cores. We describe the results of computational analyses of the thermal properties of this ferrite-based TB seed in modelled patient-specific anatomy, as well as studies of the interseed and scatter (ISA) effect. Methods: The anatomies (including the thermophysical properties of the main tissue types) and seed distributions of 6 prostate patients who had been treated with LDR brachytherapy seeds were modelled in the finite element analysis software COMSOL, using ferrite-based TB and additional hyperthermia-only (HT-only) seeds. The resulting temperature distributions were compared to those computed for patient-specific seed distributions, but in uniform anatomy with a constant blood perfusion rate. The ISA effect was quantified in the Monte Carlo software package MCNP5. Results: Compared with temperature distributions calculated in modelled uniform tissue, temperature distributions in the patient-specific anatomy were higher and more heterogeneous. Moreover, the maximum temperature to the rectal wall was typically ∼1 °C greater for patient-specific anatomy than for uniform anatomy. The ISA effect of the TB and HT-only seeds caused a reduction in D90 similar to that found for previously-investigated NiCu-based seeds, but of a slightly smaller magnitude. Conclusion: The differences between temperature distributions computed for uniform and patient-specific anatomy for ferrite-based seeds are significant enough that heterogeneous anatomy should be considered. Both types of modelling indicate that ferrite-based seeds provide sufficiently high and uniform hyperthermia to the prostate, without excessively heating surrounding tissues. The ISA effect of these seeds is slightly less than that for the previously-presented NiCu-based seeds.

07 ISOTOPE AND RADIATION SOURCES↗

Monaural Music Source Separation using Convolutional Sparse Coding

We present a comprehensive performance study of a new time-domain approach for estimating the components of an observed monaural audio mixture. Unlike existing time-frequency approaches that use the product of a set of spectral templates and their corresponding activation patterns to approximate the spectrogram of the mixture, the proposed approach uses the sum of a set of convolutions of estimated activations with prelearned dictionary filters to approximate the audio mixture directly in the time domain. The approximation problem can be solved by an efficient convolutional sparse coding algorithm. The effectiveness of this approach for source separation of musical audio has been demonstrated in our prior work, but under rather restricted and controlled conditions, requiring the musical score of the mixture being informed a priori and little mismatch between the dictionary filters and the source signals. In this paper, we report an evaluation that considers wider, and more practical, experimental settings. This includes the use of an audio-based multipitch estimation algorithm to replace the musical score, and an external dataset of audio single notes to construct the dictionary filters. Here, our result shows that the proposed approach remains effective with a larger dictionary, and compares favorably with the state-of-the-art nonnegative matrix factorization approach. However, in the absence of the score and in the case of a small dictionary, our approach may not be better.

97 MATHEMATICS AND COMPUTING↗

Structure‐Aware Representation Learning for Effective Performance Prediction

ABSTRACT Application performance is a function of several unknowns stemming from the interactions between the application, runtime, OS, and underlying hardware, making it challenging to model performance using deep learning techniques, especially without a large labeled dataset. Collecting such labeled longitudinal datasets can take weeks. Intuitively, developers could save analysis time during code development by taking a comparative approach between multiple applications. However, the unknown dynamic interactions between applications and execution environments make it difficult for deep learning‐based models to predict the performance of new applications. In this paper, we address these problems by presenting a labeled dataset for the community and taking a comparative analysis approach to explore the source code differences between different correct implementations of the same problem. This paper assesses the feasibility of using purely static information, for example, Abstract Syntax Tree (AST), of applications to predict performance change based on code structure. We evaluate several deep learning‐based representation learning techniques for source code and propose an architecture for the tree‐based Long Short‐Term Memory (LSTM) models to discover latent representations for a source code's hierarchical structure. We demonstrate that our proposed architecture enables feed‐forward predictive models to predict change in performance using source code with up to 84% accuracy.

Ramadan, Tarek [Department of Computer Science Tex↗

Remove Welding Residual Stress for CFETR Vacuum Vessel by Trailing Ultrasonic Impact Treatment

The China fusion engineering test reactor (CFETR) vacuum vessel is welded by narrow gap TIG (NG-TIG) welding, and the welding residual stress of the CFETR vacuum vessel can be redistributed by trailing welding ultrasonic impact treatment. In order to investigate the feasibility of the residual stress removing scheme, and to obtain the optimal trailing ultrasonic impact treatment technological parameters in the process of removing welding residual stress, a welding model that similar to vacuum vessel welding seam is established by using ABAQUS software, a NG-TIG welding heat source subroutine which is written in FORTRAN language used to simulate NG-TIG welding. According to the welding simulation results, a trailing welding ultrasonic impact treatment model is established, and the effects of the impact pin number, the impact method, the impact pin diameter and the impact frequency on welding residual stress are studied. The results show that the longitudinal residual stress in welding seam and its adjacent area and the lateral residual stress in the whole region have been obviously decreased by different trailing welding ultrasonic impact processes, and have made the tensile stress in the welding seam and its adjacent area has been changed into compressive stress, which can provide theoretical guidance and reference for actual production.

36 MATERIALS SCIENCE↗

Detection rate evaluation of ex-core detectors in the subcritical OPR-1000 reactor

The OPR-1000 is a PWR reactor developed in Korea. One-type ex-core detectors for monitoring of power distributions were installed in the OPR-1000 reactor to alternate the three-types of the ex-core detectors. For the verification of the detection performances, neutron transport calculation was performed by using MCNP5 code. The reaction rate in the ex-core detectors and the neutron flux were evaluated by using MCNP5 code as changing the boron concentration from 1800 ppm to 1122 ppm in the subcritical condition. The reaction rate results in fission chamber show that minimum and maximum values are 0.03577 and 3.33563 reactions/cm{sup 3}-sec, respectively. This study can be directly used for the verification and improvement of fission chamber performance in using one-type ex-core detector. Also, it can be utilized for the production of the reference data in determining neutron source strength. It is expected the proposed simulation method can be utilized to the improvement of the dose monitoring system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TU-H-CAMPUS-IeP1-02: Validation of a CT Monte Carlo Software

Purpose: To validate the in-house developed CT Monte Carlo calculation tool GMctdospp against reference simulation sets provided by the AAPM in the new report 195. Methods: Deposited energy was calculated in four segments (test 1) and two 10 cm long cylinders (test 2) inside a CTDI phantom (following case #4 of the AAPM report 195). The x-ray point source of a given 120 kVp spectrum was collimated to a fan beam with two thicknesses (10 mm, 80 mm) for a static and a rotational setup. In addition, a given chest geometry was used to calculate deposited energy in several organs for a 0° static and a rotational beam (following case #5 of the AAPM report 195). The results of GMctdospp were compared against the particular mean value of the four quoted Monte Carlo codes (EGSnrc, Geant 4, MCNP and Penelope). Results: Calculated values showed no outliers in any of the cases. Differences between GMctdospp and the particular mean Results: Calculated values showed no outliers in any of the cases. Differences between GMctdospp and the particular mean value were always at similar magnitude compared to the quoted codes. For case #4 (CTDI phantom) the relative differences were within 1.5 %, on average 0.4 % and for case #5 (chest phantom) within 2.5 % and on average 0.85 %. Conclusion: The results confirmed an overall uncertainty of the Monte-Carlo calculation chain in GMctdospp being <2.5 %, for most cases even better. This can be considered small compared to other sources of uncertainties, e.g. virtual source and patient models. The photon transport implemented in GMctdospp inside a voxel-based patient geometry was successfully verified.

60 APPLIED LIFE SCIENCES↗

Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis

We present the development and characterization of a dedicated resonant soft x-ray scattering facility. Capable of operation over a wide energy range, the beamline and endstation are primarily used for scattering from soft matter systems around the carbon K-edge ({approx}285 eV). We describe the specialized design of the instrument and characteristics of the beamline. Operational characteristics of immediate interest to users such as polarization control, degree of higher harmonic spectral contamination, and detector noise are delineated. Of special interest is the development of a higher harmonic rejection system that improves the spectral purity of the x-ray beam. Special software and a user-friendly interface have been implemented to allow real-time data processing and preliminary data analysis simultaneous with data acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-557: Measuring Neutron Activation of Cardiac Devices Irradiated During Proton Therapy Using Indium Foils

Purpose: Measuring Neutron Activation of Cardiac devices Irradiated during Proton Therapy using Indium Foils Methods: The foils had dimensions of 25mm x 25mm x 1mm. After being activated, the foils were placed in a Canberra Industries well chamber utilizing a NaI(Tl) scintillation detector. The resulting gamma spectrum was acquired and analyzed using Genie 2000 spectroscopy software. One activation foil was placed over the upper, left chest of RANDO where a pacemaker would be. The rest of the foils were placed over the midline of the patient at different distances, providing a spatial distribution over the phantom. Using lasers and BBs to align the patient, 200 MU square fields were delivered to various treatment sites: the brain, the pancreas, and the prostate. Each field was shot at least a day apart, giving more than enough time for activity of the foil to decay (t1=2 = 54.12 min). Results: The net counts (minus background) of the three aforementioned peaks were used for our measurements. These counts were adjusted to account for detector efficiency, relative photon yields from decay, and the natural abundance of 115-In. The average neutron flux for the closed multi-leaf collimator irradiation was measured to be 1.62 x 106 - 0.18 x 106 cm2 s-1. An order of magnitude estimate of the flux for neutrons up to 1 keV from Diffenderfer et al. gives 3 x 106 cm2 s-1 which does agree on the order of magnitude. Conclusion: Lower energy neutrons have higher interaction cross-sections and are more likely to damage pacemakers. The thermal/slow neutron component may be enough to estimate the overall risk. The true test of the applicability of activation foils is whether or not measurements are capable of predicting cardiac device malfunction. For that, additional studies are needed to provide clinical evidence one way or the other.

07 ISOTOPE AND RADIATION SOURCES↗

TH-CD-BRA-09: Towards Absolute Dose Measurement in MRI-Linac and Gamma-Knife: Design and Construction of An MR-Compatible Water Calorimeter

Purpose: The purpose of this work is to design and optimize a portable Water Calorimeter (WC) for use in a commercial MRI-linac and Gamma-knife in addition to conventional radiotherapy linacs. Water calorimeters determine absorbed dose to water at a point by measuring radiation-induced temperature rise of the volume (the two are related by the medium specific heat capacity). In this formalism, one important correction factor is heat transfer correction k-ht. It compensates for heat gain/loss due to conductive and convective effects, and is numerically calculated as ratio of temperature rise in the absence of heat loss to that in the presence of heat loss. Operating at 4°C ensures convection is minimal. Methods: A commercial finite element software was used to evaluate several WC designs with different insulation materials and thicknesses; channels allowing coolant to travel around WC (to sustain WC at 4°C) were modeled, and worst-case scenario variation in the temperature of the coolant was simulated for optimization purposes (2.6 mK/s). Additionally, several calorimeter vessel design parameters (front/back glass thickness/separation, diameter) were also simulated and optimized. Optimization is based on minimizing long term calorimeter drift (24h) as well as variation and magnitude of k-ht. Results: The final selected WC design reached a modest drift of 11µK/s after 15h for the worst-case coolant temperature variation. This design consists of coolant channels being encompassed on both sides by cryogel insulation. For the MRI-linac beam, glass thickness plays the largest effect on k-ht with variation of upto 0.6% in the first run for thicknesses ranging between 0.5–1.7mm. Subsequent runs vary only within 0.1% with glass thickness. Other factors such as vessel radius and top/bottom glass separation have sub 0.1% effects on k-ht. Conclusion: An MR-safe 4°C stagnant WC appropriate for dosimetry in MRI-linac and Gamma-Knife was designed, optimized, and construction is nearly completed. NSERC Discovery Grant RGPIN-435608.

07 ISOTOPE AND RADIATION SOURCES↗