Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development of Computational Environmental Microbiome Workflows for the Laboratory and the International Space Station

Identification of microorganisms in the spaceflight environment is critical for crew health risk assessment on the International Space Station (ISS). Since 2017, nanopore sequencing technology has been used to support thein situ identification of microbial species during spaceflight. Beginning in 2018, a culture-independent, swab-to-sequencer method was implemented onboard the ISS to provide a more thorough insight of the ISS microbiome. Eliminating microbial culture enables identification of difficult-to-culture organisms, reduces risks associated with potentially pathogenic cultures, and could significantly reduce the time from sample-to-answer. However, this molecular-based approach generates large metagenomic datasets that require substantial computational resources for analysis. To process nanopore-generated sequencing data, the JSC Microbiology Laboratory established a bioinformatics workflow on Amazon EC2 under the security guidance of the NASA Science Managed Cloud Environment (SMCE).This resource allows for the development, testing, and accessing of computational tools for processing large and complex datasets. The work described here will address the downlinking of data from the ISS, the automated pipeline developed to identify targeted bacterial and fungal organisms, and the time from sampling onboard to microbial identification. The pipelines have been enhanced to address high and low biomass samples using optimization based on sample source (air, water, or surface) and type of collection (filter, colony, or swab).The resulting microbiome data can be assessed beyond microbial identifications to gain understanding toward population changes over time, potential selective environmental pressures, and evaluating correlations with a wide range of additional data sets. Metagenome analysis pipelines in development could allow for simultaneous identification of microbial species, gene function, and gene pathways present in the environment. Beyond the ground processing, the developed analysis pipeline is currently deployed onboard the ISS to allow for near real-time assessments of the ISS microbiome. This study serves as a critical foundation for exploration missions, where rapid microbiome analyses will be required.

G. Marie Sharp↗

Supervisory sampling and control: Sources of suboptimality in a prediction task

A process supervisor is defined as a person who decides when to sample the process input and what values of a control variable to specify in order to maximize (minimize) a given value function of input sampling period, control setting, and process state. Presented experimental data in such a process where the value function is a time-averaged sampling cost plus mean squared difference between input and control variable. The task was unpaced prediction of the output of a second order filter driven by white noise. Experimental results, when compared to the optical strategy, reveal several consistently suboptimal behaviors. One is a tendency not to choose a long prediction interval even though the optimal strategy dictates that one should. Some results are also interpreted in terms of those input parameters according to which each subjects' behavior would have been nearest optimal. Differences of those parameters from actual input parameters served to quantify how subjects' prediction behavior differed from optimal.

Sheridan, T. B.↗

The correlation of X-ray emission with strong millimeter activity in extragalactic sources

A sample of 25 strong extragalactic millimeter sources have been observed at about 1 keV with the Imaging Proportional Counter on the Einstein X-Ray Observatory and at 90 GHz with the NRAO 11 m telescope. A strong correlation between the millimeter and X-ray flux densities is found. This result is consistent with a synchronous self-Compton model in which the X-ray emission arises from the Compton scattering of millimeter radio photons off the relativistic electrons which created them.

Owen, F. N.↗

VLA observations of a complete sample of extragalactic X-ray sources. II

A complete sample of 35 X-ray selected sources found with the Einstein Observatory has been observed with the Very Large Array at 6 cm to investigate the relationship between radio and X-ray emission in extragalactic objects. Detections include three active galactic nuclei (AGNs), two clusters or groups of galaxies, two individual galaxies, and two BL Lac objects. The frequency of radio emission in X-ray selected AGNs is compared with that of optically selected quasars using the integral radio-optical luminosity function. The result suggests that the probability for X-ray selected quasars to be radio sources is higher than for those optically selected. No obvious correlation is found in the sample between the richness of X-ray luminosity of the cluster and the presence of a galaxy with radio luminosity at 5 GHz larger than 10 to the 30th ergs/s/Hz.

Schild, R.↗

Simultaneous Sampling Of Two Spectral Sources

New technique uses bundle of fiber optics to sample a dye laser and a spectral lamp simultaneously. By use of real-time display with this sampling technique, two signals superimposed, and effect of any spectral adjustments determined immediately. System used to diagnose combustion.

Jarrett, Olin, Jr.↗

A search for precursors of ultracompact H II regions in a sample of luminous IRAS sources. III. Circumstellar dust properties

The James Clerk Maxwell Telescope has been used to obtain submillimeter and millimeter continuum photometry of a sample of 30 IRAS sources previously studied in molecular lines and centimeter radio continuum. All the sources have IRAS colours typical of very young stellar objects (YSOs) and are associated with dense gas.

(astronomical) pre-main-sequence stars radiosource↗

The Swift-BAT Hard X-ray Transient Monitor

The Burst Alert Telescope (BAT) on the Swift satellite is a large field of view instrument that continually monitors the sky to provide the gamma-ray burst trigger for Swift. An average of more than 70% of the sky is observed on a daily basis. The survey mode data is processed on two sets on time scales: from one minute to one day as part of the transient monitor program, and from one spacecraft pointing (approx.20 minutes) to the full mission duration for the hard X-ray survey program. The transient monitor has recently become public through the web site http:// swift.gsfc.nasa.gov/docs/swift/results/transients/. Sky images are processed to detect astrophysical sources in the 15-50 keV energy band and the detected flux or upper limit is calculated for >100 sources on time scales up to one day. Light curves are updated each time that new BAT data becomes available (approx.10 times daily). In addition, the monitor is sensitive to an outburst from a new or unknown source. Sensitivity as a function of time scale for catalog and unknown sources will be presented. The daily exposure for a typical source is approx.1500-3000 seconds, with a 1-sigma sensitivity of approx.4 mCrab. 90% of the sources are sampled at least every 16 days, but many sources are sampled daily. It is expected that the Swift-BAT transient monitor will become an important resource for the high energy astrophysics community.

Krimm, Hans↗

The Quasar Fraction in Low-Frequency Selected Complete Samples and Implications for Unified Schemes

Low-frequency radio surveys are ideal for selecting orientation-independent samples of extragalactic sources because the sample members are selected by virtue of their isotropic steep-spectrum extended emission. We use the new 7C Redshift Survey along with the brighter 3CRR and 6C samples to investigate the fraction of objects with observed broad emission lines - the 'quasar fraction' - as a function of redshift and of radio and narrow emission line luminosity. We find that the quasar fraction is more strongly dependent upon luminosity (both narrow line and radio) than it is on redshift. Above a narrow [OII] emission line luminosity of log(base 10) (L(sub [OII])/W) approximately > 35 [or radio luminosity log(base 10) (L(sub 151)/ W/Hz.sr) approximately > 26.5], the quasar fraction is virtually independent of redshift and luminosity; this is consistent with a simple unified scheme with an obscuring torus with a half-opening angle theta(sub trans) approximately equal 53 deg. For objects with less luminous narrow lines, the quasar fraction is lower. We show that this is not due to the difficulty of detecting lower-luminosity broad emission lines in a less luminous, but otherwise similar, quasar population. We discuss evidence which supports at least two probable physical causes for the drop in quasar fraction at low luminosity: (i) a gradual decrease in theta(sub trans) and/or a gradual increase in the fraction of lightly-reddened (0 approximately < A(sub V) approximately < 5) lines-of-sight with decreasing quasar luminosity; and (ii) the emergence of a distinct second population of low luminosity radio sources which, like M8T, lack a well-fed quasar nucleus and may well lack a thick obscuring torus.

Willott, Chris J.↗

IRAS observations of AGN candidates at low flux levels

IRAS additional observations were used to obtain a sample of point sources at much fainter flux levels than hitherto available through the IRAS Point Source Catalogue. This sample is being used to compile an incomplete but representative catalogue of faint IRAS candidate Active Galactic Nuclei (AGNs) and to study the evolution of the infrared bright galaxies. Ground based follow up observations (optical spectroscopy) are mainly hampered by identification confusion.

Degrijp, Marinus H. K.↗

Integrated Microfluidic Gas Sensors for Water Monitoring

A silicon-based microhotplate tin oxide (SnO2) gas sensor integrated into a polymer-based microfluidic system for monitoring of contaminants in water systems is presented. This device is designed to sample a water source, control the sample vapor pressure within a microchannel using integrated resistive heaters, and direct the vapor past the integrated gas sensor for analysis. The sensor platform takes advantage of novel technology allowing direct integration of discrete silicon chips into a larger polymer microfluidic substrate, including seamless fluidic and electrical interconnects between the substrate and silicon chip.

Zhu, L.↗

X-ray spectra of a complete sample of extragalactic core-dominated radio sources

We present ROSAT soft X-ray spectra for the members of a complete sample of 13 core-dominated, flat radio spectrum sources. The sample comprises all radio sources from a flux-limited radio catalog (S(sub 5GHz) greater than 1 Jy; Kuehr et al. 1981) which are north of delta = 70 deg, at galactic latitudes b greater than 10 deg, and have a flat radio spectrum between 1.4 and 5 GHz (alpha(sub r) less than 0.5; f approximately nu(sup -alpha)). The sources have already undergone much study at radio and optical wavelengths and are classified in broad terms as quasars (8 sources) and BL Lac objects (5 sources). We find mean X-ray power-law energy indices of alpha(sub x) = 0.59 +/- 0.19 for the quasars and 1.36 +/- 0.27 for the BL Lac objects (68% confidence range for two parameters of interest as determined by a maximum likelihood method), supporting earlier Einstein Observatory results for heterogeneous samples of sources (Worrall & Wilkes 1990). A non-zero dispersion on alpha(sub x) is found for both the quasars and the BL Lac objects. When we incorporate published radio, mm, and optical measurements and compare the X-ray and broad-band spectral indices alpha(sub x), alpha(sub rx), alpha(sub mm,x), and alpha(sub ox), the most obvious difference between the quasar and BL Lac subsamples lies within the X-ray band. We have fitted the multi-wavelength data to inhomogeneous synchotron-self-Compton models and find that, for the BL Lac objects with steep X-ray spectra, synchotron emission can account for the radio to soft X-ray measurements, whereas the BL Lac objects with hard X-ray spectra and the quasars require significant Compton emission to model the spectral flattening indicated by alpha(sub x) less than alpha(sub ox).

Brunner, H.↗

Sample size and sampling errors as the source of dispersion in chemical analyses

The paper describes a Monte Carlo model for simulation of two-dimensional representations of thin sections of some of the more common igneous rock textures. These representations are extrapolated to three dimensions to develop a volume of 'rock'. The model (here applied to a medium-grained high-Ti basalt) can be used to determine a statistically significant sample for a lunar rock or to predict the probable errors in the oxide contents that can occur during the analysis of a sample that is not representative of the parent rock.

Clanton, U. S.↗

Early evolution of the crust-mantle system

Nd isotopic data indicate that most Archean igneous rocks including compositions ranging from komatiite to tonalite are derived from undepleted or depleted upper mantle sources. If sampling is representative, only a few require enriched sources. A major unresolved question is the fate of the material removed from the upper mantle leaving early depleted sources as residue. One possibility is that widespread depletion of the early mantle resulted from a period of early degassing and magmatism. Rare gas isotopic data, in particular 129Xe/130Xe ratios, seem to demand that the upper mantle was extensively degassed at or before 4.4 b.y. and this led to rapid growth of the atmosphere and oceans. The lower mantle, however, was not significantly degassed during this event. It is likely that such widespread degassing and magmatism of the upper mantle transferred significant quantities of incompatible elements into the uppermost mantle or crust. Once formed, such an enriched fraction should resist recycling into the mantle and collect at or near the Earth's surface. One possibility is that it collects chiefly in a zone of partial melting, analogous to the present low-velocity zone at the base of the lithosphere.

Condie, K. C.↗

Dual Source Mass Spectrometer and Sample Handling System

We present details of a miniature integrated time-of-flight mass spectrometer and sample handling system under development to address some of the needs for in situ sample analysis on landed missions. Additional information is contained in the original extended abstract.

Brinckerhoff, W. B.↗