Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Orbitron: A crossed-field device for co-confinement of high energy ions and electrons

To explore the confinement of high-energy ions above the space charge limit, we have developed a hybrid magnetic and electrostatic confinement device called an Orbitron. The Orbitron is a crossed-field device combining aspects of magnetic mirrors, magnetrons, and orbital ion traps. Ions are confined in orbits around a high-voltage cathode with co-rotating electrons confined by a relatively weak magnetic field. Experimental and computational investigations focus on reaching ion densities above the space charge limit through the co-confinement of electrons. The experimental apparatus and suite of diagnostics are being developed to measure the critical parameters, such as plasma density, particle energy, and fusion rate for high-energy, non-thermal plasma conditions in the Orbitron. Initial results from experimental and computational efforts have revealed the need for cathode voltages on the order of 100–300 kV, leading to the development of a custom high voltage, ultra-high vacuum bushing rated for 300 kV.

Materials Science↗

Model predictive current profile control in tokamaks by exploiting spatially moving electron cyclotron current drives

The plasma control systems in next-generation tokamaks like ITER will balance competing control objectives to achieve the desired level of performance in advanced scenarios while preventing magnetohydrodynamic instabilities and disruptions. During normal tokamak operation, the points of incidence of the electromagnetic waves generated by the electron cyclotron heating and current drives (EC H&CDs) are usually fixed in space. However, the points of incidence can be modified in real-time by changing the angles of the mirrors that reflect the EC H&CD waves. Altering the points of incidence, in turn, varies the ability of the plasma control system to regulate a plasma property. For instance, changing the EC H&CD wave incidence location may place the power demands necessary to achieve a particular plasma target within saturation limits. Therefore, using the EC H&CD deposition location, which is related to the EC H&CD mirror angle, as a supplementary controllable variable may facilitate access to a given target scenario. However, active scenario-control algorithms have not been designed so far to fully exploit this capability in real time. In this work, a model predictive controller that can handle actuation locations as control inputs is developed. In particular, the controller is designed to regulate both the auxiliary powers and the EC H&CD deposition locations in a pre-defined optimal sense to achieve the control objective of attaining and sustaining a target current profile. Further, the proposed controller is tested for a DIII-D tokamak scenario in nonlinear simulations using the Control Oriented Transport SIMulator (COTSIM).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

General guide concepts for compact, high-brilliance neutron moderators

The trend in neutron sciences is toward integrating compact, high-brightness moderators into new or upgraded facilities. Transporting neutrons from the source to the sample position with a phase-space distribution tailored to specific requirements is crucial to leverage high source brilliance. Here we have investigated four guide concepts using Monte Carlo ray tracing simulations: Montel beamline with nested Kirkpatrick–Baez mirrors, curved-tapered beamline with a bender and straight sections, straight-elliptical beamline, and curved-elliptical beamline. The straight-elliptical (curved-elliptical) beamline features two half-ellipse guides connected by a straight (non-straight) guide section. The neutron transport efficiency and phase space homogeneity have been quantitatively compared. Our results show that the straight-elliptical beamline performs best because of few neutron bounces on the guide surface with small reflection angles, minimizing flux loss. The Montel beamline provides the best spatial confinement of neutrons within the desired region; however, there is a high thermal-neutron loss due to large reflection angles. The curved-tapered beamline suffers from significant flux loss due to high bounces, and it shows a non-uniform angular distribution related to broad ranges of bounces and reflection angles. The non-straight guide section of the curved-elliptical beamline increases the phase space inhomogeneity, leading to a spatially non-uniform beam profile. The results apply to general neutron instruments that require transporting thermal and cold neutrons from a compact, high-brilliance moderator to the sample location with a moderate phase-space volume.

47 OTHER INSTRUMENTATION↗

Convolutional double copy in (anti) de Sitter space

The double copy is a remarkable relationship between gauge theory and gravity that has been explored in a number of contexts, most notably scattering amplitudes and classical solutions. The convolutional double copy provides a straightforward method to bridge the two theories via a precise map for the fields and symmetries at the linearised level. This method has been thoroughly investigated in flat space, offering a comprehensive dictionary both with and without fixing the gauge degrees of freedom. In this paper, we extend this to curved space with an (anti) de Sitter background metric. We work in the temporal gauge, and employ a modified convolution that involves the Mellin transformation in the time direction. As an example, we show that the point-like charge in gauge theory double copies to the (dS-) Schwarzschild black hole solution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectral phase singularity and topological behavior in perfect absorption

Perfect absorbers, which can achieve total absorption of all incoming energy, have been extensively studied in the last decades for various important technologies in general wave systems. Here, we show that perfect absorption (PA) is generically associated with topological spectral phase singularity (SPS), carrying conserved and tunable quantized topological invariants in spectral space. The order of topological invariant $\tilde{v}$ depends on the number of degenerate outgoing channels. Two commonly studied absorbers, mirror-backed and all-dielectric structures, are reexamined from a topological perspective to reveal the generation, evolution, and annihilation of SPSs with $\tilde{v}$ = ±1 or even high orders (i.e., $\tilde{v}$ = ±2,±4). A strategy based on charge conservation of SPSs to design dual-band perfect absorbers has been established. Our findings establish the topological origin of the robust existence of PA. More broadly, in this letter, we highlight topology as the fundamental property of conventional scattering behaviors. Finally, this insight could lead to opportunities in applications such as biosensing, topological metasurfaces, and micro/nano thermal radiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MCTrans++: a 0-D model for centrifugal mirrors

The centrifugal mirror confinement scheme incorporates supersonic rotation of a plasma into a magnetic mirror device. This concept has been shown experimentally to drastically decrease parallel losses and increase plasma stability as compared with prior axisymmetric mirrors. MCTrans++ is a dimensionless (0-D) scoping tool which rapidly models experimental operating points in the Centrifugal Mirror Fusion Experiment (CMFX) at the University of Maryland. In the low-collisionality regime, parallel losses can be modelled analytically. A confining potential is set up that is partially ambipolar and partially centrifugal. Due to the stabilizing effects of flow shear, the perpendicular losses can be modelled as classical. Radiation losses such as bremsstrahlung and cyclotron emission are taken into account. A neutrals model is included, and, in some circumstances, charge-exchange losses are found to exceed all other loss mechanisms. We use the SUNDIALS ARKODE library to solve the underlying equations of this model; the resulting software is suitable for scanning large parameter spaces, and can also be used to model time-dependent phenomena such as a capacitive discharge. MCTrans++ has been used to verify results from prior centrifugal mirrors, create an experimental plan for CMFX and find configurations for future reactor-scale fusion devices.

Schwartz, Nick R. (ORCID:0000000296846435)↗

Calibration of the IXPE Focal Plane X-Ray Polarimeters to Polarized Radiation

The Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission—in partnership with the Italian Space Agency—dedicated to X-ray polarimetry in the 2–8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector, a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units at INAF-IAPS, in Italy, where a dedicated facility was setup at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.

79 ASTRONOMY AND ASTROPHYSICS↗

Photovoltaic device for enhancing power output of concentrating solar thermal power plants

A photovoltaic retrofit device for a concentrating solar thermal power plant having a parabolic trough reflector, and a fluid receiver with working fluid therein spaced from the reflector and positioned at a focal point of the reflector. The photovoltaic device includes a plurality of adjustable angle dichroic mirrors positioned between the parabolic trough reflector and the fluid receiver. A photovoltaic receiver assembly has multiple photovoltaic panels in angular relationship to each other. A photovoltaic temperature regulating system includes a fluid medium to regulate temperature of the photovoltaic panels.

Otanicar, Todd↗

Semi-implicit continuum kinetic modeling of weakly collisional parallel transport in a magnetic mirror

We present implicit-explicit (IMEX) kinetic simulations of weakly collisional parallel plasma transport in magnetic mirror configurations using the continuum code COGENT. The numerical scheme employs a Jacobian-free Newton–Krylov method with algebraic multigrid preconditioning to overcome the severe time step limitations imposed by strong mirror forces in fully explicit schemes. Applied to parameters relevant to the Wisconsin HTS Axisymmetric Mirror experiment, the IMEX approach enables time steps up to 2.5×10 4 times larger than those permitted by explicit methods, resulting in a 2500× speedup in 1D–2V simulations of parallel transport with kinetic ions and Boltzmann electrons. Additionally, a reduced bounce-averaged model for a square mirror is implemented to support the computationally intensive fully kinetic simulations. The bounce-averaged formulation is used to evaluate the numerical convergence of the velocity-space discretization algorithms and to assess the role of the collision model by comparing simulations employing the nonlinear Fokker–Planck and the simplified Lenard–Bernstein–Dougherty collision operators.

Collision theories↗

Fourier-based three-dimensional multistage transformer for aberration correction in multicellular specimens

High-resolution tissue imaging is often compromised by sample-induced optical aberrations that degrade resolution and contrast. Although wavefront sensor-based adaptive optics (AO) can measure these aberrations, such hardware solutions are typically complex, expensive to implement and slow when serially mapping spatially varying aberrations across large fields of view. Here we introduce AOViFT (adaptive optical vision Fourier transformer)—a machine learning-based aberration sensing framework built around a three-dimensional multistage vision transformer that operates on Fourier domain embeddings. AOViFT infers aberrations and restores diffraction-limited performance in puncta-labeled specimens with substantially reduced computational cost, training time and memory footprint compared to conventional architectures or real-space networks. We validated AOViFT on live gene-edited zebrafish embryos, demonstrating its ability to correct spatially varying aberrations using either a deformable mirror or postacquisition deconvolution. By eliminating the need for the guide star and wavefront sensing hardware and simplifying the experimental workflow, AOViFT lowers technical barriers for high-resolution volumetric microscopy across diverse biological samples.

Alshaabi, Thayer [Howard Hughes Medical Institute,↗

Entanglement maximization and mirror symmetry in two-Higgs-doublet models

We consider 2-to-2 scatterings of Higgs bosons in a CP-conserving two-Higgs-doublet model (2HDM) and study the implication of maximizing the entanglement in the flavor space, where the two doublets Φ a , a = 1, 2, can be viewed as a qubit: Φ 1 = |0⟩ and Φ 2 = |1⟩. More specifically, we compute the scattering amplitudes for Φ a Φ b → Φ c Φ d and require the outgoing flavor entanglement to be maximal for a full product basis such as the computational basis, which consists of {|00⟩, |01⟩, |10⟩, |11⟩}. In the unbroken phase and turning off the gauge interactions, entanglement maximization results in the appearance of an U(2) × U(2) global symmetry among the quartic couplings, which in general is broken softly by the mass terms. Interestingly, once the Higgs bosons acquire vacuum expectation values, maximal entanglement enforces an exact U(2) × U(2) symmetry, which is spontaneously broken to U(1) × U(1). As a byproduct, this gives rise to Higgs alignment as well as to the existence of 6 massless Nambu-Goldstone bosons. The U(2) × U(2) symmetry can be gauged to lift the massless Goldstones, while maintaining maximal entanglement demands the presence of a discrete Z 2 symmetry interchanging the two gauge sectors. The model is custodially invariant in the scalar sector, and the inclusion of fermions requires a mirror dark sector, related to the standard one by the Z 2 symmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extremely Metal-poor Galaxies in DESI DR1: Connections to Galaxies in the Early Universe

Extremely metal-poor galaxies (XMPGs), defined as having metallicities below 10% of the solar value, are considered possible local analogs to primordial systems and offer a unique window into early galaxy evolution. This study presents a large-scale search for XMPGs using data from the Dark Energy Spectroscopic Instrument Data Release 1, systematically evaluating their resemblance to high-redshift galaxies. From a parent sample of more than 14 million galaxies, we identify 662 (556 new) confirmed XMPGs and 763 (666 new) high-quality candidates via the direct T$_{e}$ method. Our results reveal that XMPGs follow a distinct star-forming main sequence (SFMS) that is elevated and shallower than that of the comparing star-forming galaxies. Notably, at higher stellar masses (M$_{⋆}$ > 10$^{7.5}$M$_{⊙}$), the XMPG SFMS converges with the sequence observed in high-redshift galaxies by the James Webb Space Telescope, indicating that mature XMPGs sustain star formation rates comparable to their primordial counterparts. Furthermore, XMPGs consistently deviate below the local fundamental metallicity relation, mirroring high-redshift galaxy behavior. These findings demonstrate that XMPGs not only exhibit low metallicities but also preserve scaling relations characteristic of the early Universe, confirming their potential value as local laboratories for studying early galaxy formation processes.

Sui, Jipeng [Beijing Observ.; Beijing, GUCAS] (ORC↗

A light QCD axion with hilltop misalignment

We study the cosmological evolution of a light QCD axion and identify the parameter space to obtain the correct relic dark matter abundance. The axion potential is flattened at the origin, corresponding to the only minimum, while it is unsuppressed at π. These potential features arise by assuming a mirror sector with the strong CP phase $\overline{θ}$ shifted by π compared to the SM sector, which allows the mirror axion potential to be tuned against the usual QCD axion potential. Before the QCD phase transition, assuming the mirror sector is decoupled and much colder than the SM thermal bath, the mirror sector potential dominates, causing the axion to initially roll to a temporary minimum at π. However, after the QCD phase transition, the potential minimum changes, and the axion relaxes from the newly created “hilltop” near π to the CP-conserving minimum at the origin. As the axion adiabatically tracks this shift in the potential minimum through the QCD phase transition, with non-adiabatic evolution near π and 0, it alters the usual prediction of the dark matter abundance. Consequently, this “hilltop” misalignment mechanism opens new regions of axion parameter space, with the correct relic abundance while still solving the strong CP problem, that could be explored in future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

Nuclear Charge Radii of Silicon Isotopes

The nuclear charge radius of 32 Si was determined using collinear laser spectroscopy. The experimental result was confronted with ab initio nuclear lattice effective field theory, valence-space in-medium similarity renormalization group, and mean field calculations, highlighting important achievements and challenges of modern many-body methods. The charge radius of 32 Si completes the radii of the mirror pair 32 Ar – 32 Si, whose difference was correlated to the slope L of the symmetry energy in the nuclear equation of state. Furthermore, our result suggests L ≤ 60 MeV, which agrees with complementary observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Path integral games with de Sitter α-vacua

The α-vacua are a 1-parameter family of quantum field vacua in de Sitter space which are invariant under the isometry group SO(1, d). In this work give a path integral construction of the de Sitter α-vacua. We explain that these states can be prepared by acting on the Bunch-Davies vacuum with a certain non-local charge operator. While most conserved charges live on a single codimension-1 manifold, we show that this particular charge lives on a pair of two codimension-1 manifolds which are antipodal mirrors of each other. The rules for the manipulation of this charge as an insertion in the path integral are explained. We further explain how this charge can be used to solve for the wavefunctionals of the α-vacua at $\mathcal{I}$ | (in the regime that α is small) by deforming the equator of de Sitter space to $\mathcal{I}$ + /$\mathcal{I}$ – .

Global Symmetries↗

Loss-cone stabilization in rotating mirrors: thresholds and thermodynamics

In the limit of sufficiently fast rotation, rotating mirror traps are known to be stable against the loss-cone modes associated with conventional (non-rotating) mirrors. This paper calculates how quickly a mirror configuration must rotate in order for several of these modes to be stabilized (in particular, the high-frequency convective loss cone, drift cyclotron loss cone and Dory–Guest–Harris modes). Commonalities in the stabilization conditions for these modes then motivate a modified formulation of the Gardner free energy and diffusively accessible free energy to be used for systems in which the important modes have wavevectors that are orthogonal or nearly orthogonal to the magnetic field, as well as a modification to include the effects of a loss region in phase space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics↗