Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral linewidths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

Spectrophone stabilized laser with line center offset frequency control

Continuous offset tuning of a frequency stabilized CW gas laser is achieved by using a spectrophone filled with the same gas as the laser for sensing a dither modulation, detecting a first or second derivative of the spectrophone output with a lock-in amplifier, the detected output of which is integrated, and applying the integrator output as a correction signal through a circuit which adds to the dither signal from an oscillator a dc offset that is adjusted with a potentiometer to a frequency offset from the absorption line center of the gas, but within the spectral linewidth of the gas. Tuning about that offset frequency is achieved by adding a dc value to the detected output of the dither modulation before integration using a potentiometer.

Kavaya, M. J.↗

Detection of NO sub x,C2H4 concentrations by using CO and CO2 lasers

A laser, especially the infrared line tunable laser, opens up a new way to monitor the atmospheric environment, and already has gotten effective practical application. One of the most serious problems in open path remote measurement at atmospheric pressure is the broadening effect which leads to increased linewidths, spectral interferences, and, as a result, tends to reduce detection sensitivity, so measuring laser wavelengths should be selected carefully, and interaction between the measuring wavelength and gas to be measured must be known very well. Therefore, N2O, No, NO2, CH4, NH3 and C2H4 absorption properties at some lines of CO and CO2 line tunable lasers were studied. The absorption coefficients of NO, NO2, and C2H4; some results on detection of NO sub x, C2H4 concentrations in both laboratory and field; and selection of measuring wavelengths and error analysis are discussed.

Gengchen, W.↗

A lidar system for measuring atmospheric pressure and temperature profiles

The design and operation of a differential absorption lidar system capable of remotely measuring the vertical structure of tropospheric pressure and temperature are described. The measurements are based on the absorption by atmospheric oxygen of the spectrally narrowband output of two pulsed alexandrite lasers. Detailed laser output spectral characteristics, which are critical to successful lidar measurements, are presented. Spectral linewidths of 0.026 and 0.018 per cm for the lasers were measured with over 99.99 percent of the energy contained in three longitudinal modes.

Schwemmer, Geary K.↗

Quasi-optical Josephson-junction oscillator arrays

Josephson junctions are natural voltage-controlled oscillators capable of generating submillimeter-wavelength radiation, but a single junction usually can produce only 100 nW of power and often has a broad spectral linewidth. The authors are investigating 2D quasi-optical power combining arrays of 103 and 104 NbN/MgO/NbN and Nb/Al-AlO(x)/Nb junctions to overcome these limitations. The junctions are dc-biased in parallel and are distributed along interdigitated lines. The arrays couple to a resonant mode of a Fabry-Perot cavity to achieve mutual phase-locking. The array configuration has a relatively low impedance, which should allow the capacitance of the junctions to be tuned out at the oscillation frequency.

Stern, J. A.↗

An Intense Slit Discharge Source of Jet-Cooled Molecular Ions and Radicals (T(sub rot) less than 30 K)

A novel pulsed, slit supersonic discharge source is described for generating intense jet-cooled densities of radicals (greater than 10(exp 12)/cu cm) and molecular ions (greater than 10(exp 10)/cu cm) under long absorption path (80 cm), supersonically cooled conditions. The design confines the discharge region upstream of the supersonic expansion orifice to achieve efficient rotational cooling down to 30 K or less. The collisionally collimated velocity distribution in the slit discharge geometry yields sub-Doppler spectral linewidths, which for open-shell radicals reveals spin-rotation splittings and broadening due to nuclear hyperfine structure. Application of the slit source for high-resolution, direct IR laser absorption spectroscopy in discharges is demonstrated on species such as OH, H3O(+) and N2H(+).

Anderson, David T.↗

Spectral dispersion of the linewidth enhancement factor and four wave mixing conversion efficiency of an InAs/GaAs multimode quantum dot laser

The spectral dependence of the linewidth enhancement factor (αH-factor) of a multimode InAs/GaAs quantum dot laser is analyzed. Amplified spontaneous and high-frequency modulation methods are used to experimentally retrieve the αH-factor of each longitudinal mode below and above the threshold. A dispersion of the αH-factor is unlocked across the entire optical spectrum, which is further illustrated in the context of four wave mixing experiments. The results show that the induced conversion efficiency is increased at lasing wavelengths where the linewidth enhancement is lower. These results highlight the importance of carefully monitoring the linewidth enhancement factor in quantum dot lasers especially for frequency combs and mode-locking applications in future optical communication systems.

Ding, Shihao (ORCID:0000000346416944)↗

Lifetime-resolved photon-correlation Fourier spectroscopy

The excited state population of single solid-state emitters is subjected to energy fluctuations around the equilibrium driven by the bath and relaxation through the emission of phonons or photons. Simultaneous measurement of the associated spectral dynamics requires a technique with a high spectral and temporal resolution with an additionally high temporal dynamic range. We propose a pulsed excitation-laser analog of photon-correlation Fourier spectroscopy (PCFS), which extracts the linewidth and spectral diffusion dynamics along the emission lifetime trajectory of the emitter, effectively discriminating spectral dynamics from relaxation and bath fluctuations . This lifetime-resolved PCFS correlates photon-pairs at the output arm of a Michelson interferometer in both their time-delay between laser-excitation and photon-detection T and the time-delay between two photons τ . We propose the utility of the technique for systems with changing relative contributions to the emission from multiple states, for example, quantum emitters exhibiting phonon-mediated exchange between different fine-structure states.

36 MATERIALS SCIENCE↗

The tropospheric emission spectrometer (TES) for the Earth Observing System (EOS)

In recent years, increasing concern has been expressed about Global Change - the natural and anthropogenic alteration of the Earth's environment involving global greenhouse warming and the associated climate change, urban and regional atmospheric pollution, acid deposition, regional increases in tropospheric zone, and the decrease in stratospheric ozone. A common theme among these problems is that they all involve those tropospheric trace gases which are fundamental to the biosphere-troposphere interaction, the chemistry of the free troposphere itself, and troposphere-stratosphere exchange. The chemical species involved all have spectral signatures within the near and mid infrared that can now be measured by advanced techniques of remote-sensing infrared spectroradiometry. Such a system is the Tropospheric Emission Spectrometer (TES), now in Phase B definition for the Earth Observing System (EOS) polar platforms. TES addresses these objectives by obtaining radiometrically calibrated, linewidth-limited spectral resolution, infrared spectra of the lower atmosphere using both natural thermal emission and reflected sunlight (where appropriate) in three different, but fully programmable, modes: a gobal mode, a pointed mode, and a limb-viewing mode. The goals of TES, its instrumentation, operational modes, sensitivity and data handling are discussed.

Beer, R.↗

Linewidth narrowing in self-injection locked lasers: Effects of quantum confinement

This paper explores the impact of gain medium on linewidth narrowing in integrated self-injection locked III–V/SiN lasers, theoretically and experimentally. We focus on the effects of carrier densities of states in zero- and two-dimensional structures due to quantum-dot and quantum-well confinement. The theoretical approach includes (a) multimode laser interaction to treat mode competition and wave mixing, (b) quantum-optical contributions from spontaneous emission, and (c) composite laser/free-space eigenmodes to describe outcoupling and coupling among components within an extended cavity. For single-cavity lasers, such as distributed feedback lasers, the model reproduces the experimentally observed better linewidth performance of quantum-dot active regions over quantum-well ones. When applied to integrated III–V/SiN lasers, our analysis indicates Hz-level linewidth performance for both quantum-dot and quantum-well gain media due to overcoming the difference in carrier-induced refractive index by incorporating a high-Q SiN passive resonator. Trade-offs are also explored between linewidth, output power, and threshold current.

Cavity quantum electrodynamics↗

Charge collection and trapping mechanisms in hexagonal boron nitride epilayers

Understanding charge collection and trapping mechanisms is crucial for using hexagonal boron nitride (h-BN) as active layers for many photonic and electronic devices such as deep UV detectors and emitters, neutron detectors, and single photon emitters. Charge collection and trapping mechanisms in h-BN epilayers have been investigated by probing impurity related optical emissions under an applied electrical field. Our results suggested that the existence of oxygen impurities affects the charge collection efficiency and results in an additional emission peak at 3.75 eV, corresponding to a donor-acceptor pair (DAP) recombination involving O N (oxygen residing on the nitrogen site) donors and the V B -H (boron vacancy bonded with hydrogen complex) deep level acceptors. Experimental results further revealed that the applied electric field induces an anti-correlation between the emission intensity of the DAP transition and the charge collection efficiency from which it was shown that it is possible to find an expression to quantitatively measure the maximum charge collection efficiency in h-BN. The results introduce not only a coherent picture for the relationship between common impurities in h-BN and charge collection and trapping mechanisms but also useful insights into possible approaches to improve the quality, purity, and charge collection of the h-BN epilayers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature-dependent Spectral Emission of Hexagonal Boron Nitride Quantum Emitters on Conductive and Dielectric Substrates

We report a reduction in the linewidth and suppression of spectral diffusion of quantum emitters in hexagonal boron nitride supported on a conductive substrate. In this work, we observe a temperature-dependent reduction in the spectral emission linewidth for CVD-grown and exfoliated crystals on conductive ITO relative to those seen on silicon dioxide (SiO 2 ) substrates. We show that the inhomogeneous linewidth can be suppressed by 45% as a result of using a conductive substrate. We investigate the zero-phonon line profile at temperatures ranging from 4 to 300 K and decompose the effects of thermal broadening and spectral diffusion at each temperature by Voigt fitting. The temperature dependence of homogeneous and inhomogeneous components of the broadening is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stable isotope laser spectroscopy

Recent advances in semiconductor laser technology have produced a reliable lightweight device ideally suited for a spacecraft high resolution molecular spectrometer. Lead-salt tunable diode lasers (TDL) emit in several spectral modes, each with a very narrow linewidth of -0.0003/cm. This spectral resolution is much narrower than typical Doppler broadened molecular linewidths in the mid-IR range. Thus it is possible to detect individual rotational lines within the vibrational band and measure their intensity, which can be used to determine gas concentration. The narrow spectral lines of any impurity gas tend to lie between the narrow lines of the gas of interest. This represents a major advantage over the accepted gas chromatograph mass spectrometer (GCMS) technique for measuring gas concentrations and isotope ratios. The careful and extensive gas purification procedures required to remove impurities for reliable GCMS measurements will not be required for an IR laser gas analysis. The infrared laser gas analysis technique is being developed to measure stable isotopic ratios of gases such as CO2, CH4, N2O, and NH3. This will eventually lead to development of instruments capable of in situ istopic measurements on planets such as Mars. The carbon (C-12, C-13) isotope ratio is indicative of the type of carbon fixation mechanisms (e.g., photosynthesis, respiration) in operation on a planet, while the nitrogen (N-14, N-15) isotope ratio can probably be used to date nitrogen-bearing Martian samples. The absorbance ratio of two adjacent lines of CO2 in the 2300/cm (4.3 micron) region of the spectrum was measured. The precision of the measurement is presently better than 1 percent and significant improvement is anticipated as rapid sweep-integration techniques and computer controlled data acquistion capabilities are incorporated.

Becker, J. F.↗

The influence of laser energy on deuterium emission characteristics from a Zircaloy-4 plasma

Laser-produced plasma coupled with optical emission spectroscopy (OES) is a promising technique for detecting certain isotopes, with unique capabilities such as standoff and rapid detection and minimal to no sample preparation requirements. The key figure-of-merit for isotopic analysis using optical spectroscopy tools is the linewidth relative to the isotope shift. Although the isotopes of hydrogen (1H, 2H, and 3H) possess large isotopic shifts (1H–2H ≈ 180 pm, 1H–3H ≈ 240 pm), being a light element, the H transitions are susceptible to various broadening mechanisms in the plasma environment. One of the critical parameters that influence the linewidth of a transition in an LPP is the incident laser energy. In the present study, we evaluated the role of laser energy on plume expansion dynamics, deuterium emission intensity, and linewidth in a nanosecond laser-produced Zircaloy-4 plasma. The changes in 2Hα emission intensity and linewidth were investigated for varying laser fluence and time after plasma onset. Spatially resolved and spatially integrated OES were performed and compared to investigate the emission spectral features and linewidth of 2Hα. Monochromatic two-dimensional time-resolved imaging was also performed to understand the morphology of the deuterium and protium emission relative to all species in the plume. Our results showed that 1Hα and 2Hα emissions predominantly occur closer to the target. Measurements of 2Hα linewidth approached similar values at later times of plasma evolution regardless of the laser energy. The linewidths of the 2Hα transition showed insignificant differences between spatially resolved and spatially integrated measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Matched tandem etalon camera - MATEC - and its application to auroral observations

The matched tandem etalon camera employs a Fabry-Perot interferometer (FP) in the photographic mode for the spatial resolution over all angles up to 7 deg from normal. An interference filter and an appropriate field lens isolate a single order of 0.1 A resolution, which is recorded simultaneously at all angles in the field of view by array detection. Thus the resolution and luminosity of the MATEC camera are those of the FP. The MATEC pilot model has a ratio of free spectral range to linewidth of 400 and utilizes intensified photographic detection. In a system applied to auroral measurements the MATEC views a semiconical sky mirror to provide a simulatenous dimension of spatial resolution in the N-S meridian combined with the dimension of spectral resolution. Stellar features and cloud and ground reflections are more easily identified than by any scanning photometer.

Young, E. R.↗