Search NASA⌕ Search

SEARCH · Search NASA

Results for “Starling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Deterioration of left ventricular chamber performance after bed rest : "cardiovascular deconditioning" or hypovolemia?

BACKGROUND: Orthostatic intolerance after bed rest is characterized by hypovolemia and an excessive reduction in stroke volume (SV) in the upright position. We studied whether the reduction in SV is due to a specific adaptation of the heart to head-down tilt bed rest (HDTBR) or acute hypovolemia alone. METHODS AND RESULTS: We constructed left ventricular (LV) pressure-volume curves from pulmonary capillary wedge pressure and LV end-diastolic volume and Starling curves from pulmonary capillary wedge pressure and SV during lower body negative pressure and saline loading in 7 men (25+/-2 years) before and after 2 weeks of -6 degrees HDTBR and after the acute administration of intravenous furosemide. Both HDTBR and hypovolemia led to a similar reduction in plasma volume. However, baseline LV end-diastolic volume decreased by 20+/-4% after HDTBR and by 7+/-2% after hypovolemia (interaction P<0.001). Moreover, SV was reduced more and the Starling curve was steeper during orthostatic stress after HDTBR than after hypovolemia. The pressure-volume curve showed a leftward shift and the equilibrium volume of the left ventricle was decreased after HDTBR; however, after hypovolemia alone, the curve was identical, with no change in equilibrium volume. Lower body negative pressure tolerance was reduced after both conditions; it decreased by 27+/-7% (P<0.05) after HDTBR and by 18+/-8% (P<0.05) after hypovolemia. CONCLUSIONS: Chronic HDTBR leads to ventricular remodeling, which is not seen with equivalent degrees of acute hypovolemia. This remodeling leads to a greater decrease in SV during orthostatic stress after bed rest than hypovolemia alone, potentially contributing to orthostatic intolerance.

NASA Discipline Cardiopulmonary↗

Cardiac atrophy after bed-rest deconditioning: a nonneural mechanism for orthostatic intolerance

BACKGROUND: The cardiovascular adaptation to bed rest leads to orthostatic intolerance, characterized by an excessive fall in stroke volume (SV) in the upright position. We hypothesized that this large fall in SV is due to a change in cardiac mechanics. METHODS AND RESULTS: We measured pulmonary capillary wedge pressure (PCWP), SV, left ventricular end-diastolic volume (LVEDV), and left ventricular mass (by echocardiography) at rest, during lower-body negative pressure, and after saline infusion before and after 2 weeks of bed rest with -6 degrees head-down tilt (n=12 subjects aged 24+/-5 years). Pressure (P)-volume (V) curves were modeled exponentially by P=ae(kV)+b and logarithmically by P=-Sln[(Vm-V)/(Vm-V0)], where V0 indicates volume at P=0, and the constants k and S were used as indices of normalized chamber stiffness. Dynamic stiffness (dP/dV) was calculated at baseline LVEDV. The slope of the line relating SV to PCWP during lower-body negative pressure characterized the steepness of the Starling curve. We also measured plasma volume (with Evans blue dye) and maximal orthostatic tolerance. Bed rest led to a reduction in plasma volume (17%), baseline PCWP (18%), SV (12%), LVEDV (16%), V0 (33%), and orthostatic tolerance (24%) (all P<.05). The slope of the SV/PCWP curve increased from 4.6+/-0.4 to 8.8+/-0.9 mL/mm Hg (P<.01) owing to a parallel leftward shift in the P-V curve. Normalized chamber stiffness was unchanged, but dP/dV was reduced by 50% at baseline LVEDV, and cardiac mass tended to be reduced by 5% (P<.10). CONCLUSIONS: Two weeks of head-down-tilt bed rest leads to a smaller, less distensible left ventricle but a shift to a more compliant portion of the P-V curve. This results in a steeper Starling relationship, which contributes to orthostatic intolerance by causing an excessive reduction in SV during orthostasis.

NASA Discipline Cardiopulmonary↗

Starling1 - Mission Technologies Overview

The Starling series of demonstration missions will test technologies required to achieve affordable, distributed spacecraft ("swarm") missions that: are scalable to at least 100 spacecraft for applications that include synchronized multipoint measurements; involve closely coordinated ensembles of two or more spacecraft operating as a single unit for interferometric, synthetic aperture, or similar sensor architectures; or use autonomous or semi-autonomous operation of multiple spacecraft functioning as a unit to achieve science or other mission objectives with low-cost small spacecraft.Starling1 will focus on developing technologies that enable scalability and deep space application. The mission goals include the demonstration of a Mobile Ad-hoc NETwork (MANET) through an in-space communication experiment, vision based relative navigation through the Starling Formation-flying Optical eXperiment (StarFOX), and demonstration of autonomous spacecraft reconfiguration using technologies developed by the Distributed System Autonomy (DSA) project.

Cannon, Howard↗

Conjunction Assessment and Deconfliction Paradigm for Co-Located Satellite Constellations With on-Spacecraft “Autonomous” Flight Dynamics Control

Satellite constellations that employ on-spacecraft flight dynamics and conjunction assessment (CA) approaches face particular challenges. First, they must arrange to obtain and upload to the constellation satellite close approach information, such as Conjunction Data Messages, so that their on-board systems will have the data they need to make informed CA decisions. Second, given current latencies in obtaining CA screening information, such systems often cannot obtain dedicated screenings of their proposed maneuvers before they are executed. Third, they usually cannot engage in real time with owner/operators (O/Os) with whom they may come into conjunction, relying instead on pre-arranged courses of action that may or may not fit a given situation well. Despite these difficulties, it is nonetheless possible, as operators such as SpaceX have demonstrated, to operate safely using on-board CA calculations, in the presence of a largely collaborative operating environment. The situation breaks down, however, when two constellations that operate with such a paradigm are placed in the same orbital region and will experience conjunctions with each other. Each may have a vague idea of where the other’s satellites are, or perhaps even a somewhat precise idea if they exchange O/O ephemerides, but neither will know the other’s more immediate maneuver intentions, especially for situations in which they are in a high-risk conjunction with each other and a mitigation maneuver is required. As there is no formalized way for these automated systems to ascertain each other’s intentions for this type of conjunction, it is quite possible that each spacecraft may choose a maneuver that results in the two objects’ colliding. An opportunity to develop a solution to this problem was presented by the NASA “Starling” project, a small experimental constellation developed to demonstrate autonomous satellite control and constellation reconfiguration and for which a launch was obtained that, serendipitously, will place this constellation close to the SpaceX Starlink constellation. Because the NASA constellation is experimental, an extended mission part of the mission has been negotiated to implement and test mechanisms for resolving the problem of co-located constellations with on-board flight dynamics control. For the last eighteen months, a consortium among NASA Ames (the Starling satellite providers), NASA CARA (the Agency organization responsible for conjunction assessment), Space X, and the Department of Commerce (in observer status) has met regularly to assemble a concept of operations for a robust solution to this problem and has developed a prototype ground node that will serve as a needed CA screening and information dispensary. The approach and methods, as well as the active employment of the developed ground node, will be tested both in simulation before actual use and then in actual spacecraft operations, which are anticipated to begin in January 2024. This paper will describe the co-located autonomously-controlled constellation problem and the developed solution in detail, outlining what ground node (i.e., government) infrastructure and features are required, what particular capabilities are needed by the constellations themselves in order to make use of this deconfliction paradigm, and the migration path forward to allow such a capability set to be incorporated by the Department of Commerce’s space traffic coordination system.

Conjunction Assessment↗

NASA Small Spacecraft and Distributed Systems Program - Recent and Upcoming Technology Demonstrations and Development Efforts

NASA’s Small Spacecraft & Distributed Systems (SSDS) program strengthens U.S. ability to conduct unique missions by rapidly developing and demonstrating capabilities for SmallSat exploration, science, and commercial space. In collaboration with NASA Centers, other government agencies, commercial industry, and academia, SSDS advances next generation SmallSat technologies like power, processing, propulsion, communications, autonomous navigation, architectures (swarms), and applications (AI/ML/Edge Computing)—to extend missions beyond LEO into cislunar and planetary space. Various investment mechanisms exist for SSDS to select and fund projects that will ultimately advance NASA’s Moon to Mars Architecture. Presented here are the latest achievements and findings from recently completed SSDS projects, along with updates from ongoing efforts and planned future work. Successful missions like Starling and CAPSTONE continue to demonstrate their capability after several years on-orbit. Advancements in next generation swarm configurations are being implemented by Starling for space traffic monitoring and management applications. Findings from recent SSDS flight projects are discussed: DiskSat, a unique SmallSat platform alternative to canisterized nanosatellites, launched December 2025 and is gathering data; the PTD series of missions concluded in December 2025. Current SSDS efforts are focused on addressing NASA Shortfalls relating to rendezvous and proximity operations, neuromorphic computing, and space situational awareness.

Roger C Hunter↗

NASA Small Spacecraft and Distributed Systems: Recent and Upcoming Technology Demonstrations and Development Efforts

NASA’s Small Spacecraft & Distributed Systems (SSDS) program strengthens U.S. ability to conduct unique missions by rapidly developing and demonstrating capabilities for SmallSat exploration, science, and commercial space. In collaboration with NASA Centers, other government agencies, commercial industry, and academia, SSDS advances next generation SmallSat technologies like power, processing, propulsion, communications, autonomous navigation, architectures (swarms), and applications (AI/ML/Edge Computing)—to extend missions beyond LEO into cislunar and planetary space. Various investment mechanisms exist for SSDS to select and fund projects that will ultimately advance NASA’s Moon to Mars Architecture. Presented here are the latest achievements and findings from recently completed SSDS projects, along with updates from ongoing efforts and planned future work. Successful missions like Starling and CAPSTONE continue to demonstrate their capability after several years on-orbit. Advancements in next generation swarm configurations are being implemented by Starling for space traffic monitoring and management applications. Findings from recent SSDS flight projects are discussed: DiskSat, a unique SmallSat platform alternative to canisterized nanosatellites, launched December 2025 and is gathering data; the PTD series of missions concluded in December 2025. Current SSDS efforts are focused on addressing NASA Shortfalls relating to rendezvous and proximity operations, neuromorphic computing, and space situational awareness.

Roger Hunter↗

FOD impact testing of composite fan blades

The results of impact tests on large, fiber composite fan blades for aircraft turbofan engine applications are discussed. Solid composite blades of two different sizes and designs were tested. Both graphite/epoxy and boron/epoxy were evaluated. In addition, a spar-shell blade design was tested that had a boron/epoxy shell bonded to a titanium spar. All blades were tested one at a time in a rotating arm rig to simulate engine operating conditions. Impacting media included small gravel, two inch diameter ice balls, gelatin and RTV foam-simulated birds, as well as starlings and pigeons. The results showed little difference in performance between the graphite and boron/epoxy blades. The results also indicate that composite blades may be able to tolerate ice ball and small bird impacts but need improvement to tolerate birds in the small duck and larger category.

Johns, R. H.↗

FOD impact testing of composite fan blades

The results of impact tests on large, fiber composite fan blades for aircraft turbofan engine applications are discussed. Solid composite blades of two different sizes and designs were tested. Both graphite/epoxy and boron/epoxy were evaluated. In addition, a spar-shell blade design was tested that had a boron/epoxy shell bonded to a titanium spar. All blades were tested one at a time in a rotating arm rig to simulate engine operating conditions. Impacting media included small gravel, two inch diameter ice balls, gelatin, and RTV foam-simulated birds, as well as starlings and pigeons. The results showed little difference in performance between the graphite and boron/epoxy blades. The results also indicate that composite blades may be able to tolerate ice ball and small bird impacts but need improvement to tolerate birds in the small duck and larger category.

Johns, R. H.↗

Impact testing on composite fan blades

The results of impact tests on large, fiber composite fan blades for aircraft turbofan engine applications are discussed. Solid composite blades of two different sizes and designs were tested. Both graphite/epoxy and boron/epoxy were evaluated. In addition, a spar-shell blade design was tested that had a boron/epoxy shell bonded to a titanium spar. All blades were tested one at a time in a rotating arm rig to simulate engine operating conditions. Impacting media included small gravel, two inch diameter ice balls, gelatin and RTV foam-simulated birds, as well as starlings and pigeons. The results showed little difference in performance between the graphite and boron/epoxy blades. The results also indicate that composite blades may be able to tolerate ice ball and small bird impacts but need improvement to tolerate birds in the small duck and larger category.

Johns, R. H.↗

Effect of gravitational and inertial forces on vertical distribution of pulmonary blood flow

Vertical distribution of pulmonary blood flow (VDPBF) was studied, using radioactive microsphere emboli, in dogs without thoracotomy in the right decubitus position during exposure to lateral accelerations of 1, 2, 4, and 6 G. At all levels of force environment studied, an inverse linear relationship was observed between vertical height in the thorax and pulmonary blood flow (ml/min/ml lung tissue) with a decrease in flow to the most dependent region of the lung despite large increases in intravascular pressures at this site. Changes in blood flow were smallest at the mid-lung level, the hydrostatic 'balance point' for vascular and pleural pressures. These force environment-dependent changes in VDPBF are not readily explainable by the Starling resistor analog. Gravity-dependent regional differences in pleural and associated interstitial pressures, plus possible changes in vascular tone resulting from inadequate aeration of blood in the most dependent regions of the lung, probably also affect VDPBF.

Chevalier, P. A.↗

Program for impact testing of spar-shell fan blades, test report

Six filament-wound, composite spar-shell fan blades were impact tested in a whirligig relative to foreign object damage resulting from ingestion of birds into the fan blades of a QCSEE-type engine. Four of the blades were tested by injecting a simulated two pound bird into the path of the rotating blade and two were tested by injecting a starling into the path of the blade.

Ravenhall, R.↗

Transcapillary fluid shifts in head and neck tissues during and after simulated microgravity

To understand the mechanism, magnitude, and time course of facial puffiness that occurs in microgravity, seven male subjects were tilted 6 degrees head down for 8 hr, and all four Starling transcapillary pressures were directly measured before, during, and after tilt. Head-down tilt (HDT) caused facial edema and a significant elevation of microvascular pressures measured in the lower lip: capillary pressures increased from 27.2 +/- 5 mm Hg pre-HDT to 33.9 +/- 1.7 mm Hg by the end of tilt. Subcutaneous and intramuscular interstitial fluid pressures in the neck also increased as a result of HDT, while interstitial fluid colloid osmotic pressures remained unchanged. Plasma colloid osmotic pressures dropped significantly after 4 hr of HDT, suggesting a transition from fluid filtration to absorption in capillary beds between the heart and feet during HDT. After 4 hr of seated recovery from HDT, microvascular pressures remained significantly elevated by 5 to 8 mm Hg above baseline values, despite a significant HDT diuresis and the orthostatic challenge of an upright, seated posture. During the control (baseline) period, urine output was 46.7 ml/hr; during HDT, it was 126.5 ml/hr. These results indicate that facial edema resulting from HDT is primarily caused by elevated capillary pressures and decreased plasma colloid osmotic pressures. Elevation of cephalic capillary pressures sustained for 4 hr after HDT suggests that there is a compensatory vasodilation to maintain microvascular perfusion. The negativity of interstitial fluid pressures above heart level also has implications for the maintenance of tissue fluid balance in upright posture.

Parazynski, S. E.↗

Transcapillary fluid shifts in tissues of the head and neck during and after simulated microgravity

To understand the mechanism, magnitude, and time course of facial puffiness that occurs in microgravity, seven male subjects were tilted 6 degrees head down for 8 hr, and all four Starling transcapillary pressures were directly measured before, during , and after tilt. Head-down tilt (HDT) caused facial edema and a significant elevation of microvascular pressures measured in the lower lip. Subcutaneous and intramuscular interstitial fluid pressures in the neck also increased as a result of HDT, while interstitial fluid colloid osmotic pressures remained unchanged. Plasma colloid osmotic pressures dropped significantly after 4 hr of HDT, suggesting a transition from fluid filtration to absorption in capillary beds between the heart and feet during HDT. After 4 hr of seated recovery from HDT, microvascular pressures remained significantly elevated by 5 to 8 mm Hg above baseline values despite a significant HDT diuresis and the orthostatic challenge of an upright, seated posture. During the control (baseline) period, urine output was 46.7 ml/hr; during HDT, it was 126.5 ml/hr.

Hargens, A. R.↗

Physiologic mechanisms of circulatory and body fluid losses in weightlessness identified by mathematical modeling

Central volume expansion due to fluid shifts in weightlessness is believed to activate adaptive reflexes which ultimately result in a reduction of the total circulating blood volume. However, the flight data suggests that a central volume overdistention does not persist, in which case some other factor or factors must be responsible for body fluid losses. We used a computer simulation to test the hypothesis that factors other than central volume overdistention are involved in the loss of blood volume and other body fluid volumes observed in weightlessness and in weightless simulations. Additionally, the simulation was used to identify these factors. The results predict that atrial volumes and pressures return to their prebedrest baseline values within the first day of exposure to head down tilt (HDT) as the blood volume is reduced by an elevated urine formation. They indicate that the mechanisms for large and prolonged body fluid losses in weightlessness is red cell hemoconcentration that elevates blood viscosity and peripheral resistance, thereby lowering capillary pressure. This causes a prolonged alteration of the balance of Starling forces, depressing the extracellular fluid volume until the hematocrit is returned to normal through a reduction of the red cell mass, which also allows some restoration of the plasma volume. We conclude that the red cell mass becomes the physiologic driver for a large 'undershoot' of the body fluid volumes after the normalization of atrial volumes and pressures.

Simanonok, K. E.↗

Renal function alterations during skeletal muscle disuse in simulated microgravity

This project was to examine the alterations in renal functions during skeletal muscle disuse in simulated microgravity. Although this area could cover a wide range of investigative efforts, the limited funding resulted in the selection of two projects. These projects would result in data contributing to an area of research deemed high priority by NASA and would address issues of the alterations in renal response to vasoactive stimuli during conditions of skeletal muscle disuse as well as investigate the contribution of skeletal muscle disuse, conditions normally found in long term human exposure to microgravity, to the balance of fluid and macromolecules within the vasculature versus the interstitium. These two projects selected are as follows: investigate the role of angiotensin 2 on renal function during periods of simulated microgravity and skeletal muscle disuse to determine if the renal response is altered to changes in circulating concentrations of angiotensin 2 compared to appropriate controls; and determine if the shift of fluid balance from vasculature to the interstitium, the two components of extracellular fluid volume, that occur during prolonged exposure to microgravity and skeletal muscle disuse is a result, in part, to alterations in the fluid and macromolecular balance in the peripheral capillary beds, of which the skeletal muscle contains the majority of recruitment capillaries. A recruitment capillary bed would be most sensitive to alterations in Starling forces and fluid and macromolecular permeability.

Tucker, Bryan J.↗

Rodent Studies of Cardiovascular Deconditioning

Changes in blood pressure can occur for two reasons: 1) A decrease in cardiac output resulting from the altered contractility of the heart or through changes in venous filling pressure via the Frank Starling mechanism or; 2) A change in systemic vascular resistance. The observed changes in cardiac output and blood pressure after long term space flight cannot be entirely explained through changes in contractility or heart rate alone. Therefore, alterations in filling pressure mediated through changes in systemic venous capacitance and arterial resistance function may be important determinants of cardiac output and blood pressure after long term space flight. Our laboratory and previous studies have shown the importance of veno-constriction mediated by the carotid sinus baroreceptor reflex system on overall circulatory homeostasis and in the regulation of cardiac output. Our proposed experiments test the overall hypothesis that alterations in venous capacitance function and arterial resistance by the carotid sinus baroreceptor reflex system are an important determinant of the cardiac output and blood pressure response seen in astronauts after returning to earth from long term exposure to microgravity. This hypothesis is important to our overall understanding of circulatory adjustments made during long term space flight. It also provides a framework for investigating counter measures to reduce the incidence of orthostatic hypotension caused by an attenuation of cardiac output. We continue to use hind limb unweighted (HLU) rat model to simulate the patho physiological effects as they relate to cardiovascular deconditioning in microgravity. We have used this model to address the hypothesis that microgravity induced cardiovascular deconditioning results in impaired vascular responses and that these impaired vascular responses result from abnormal alpha-1 AR signaling. The impaired vascular reactivity results in attenuated blood pressure and cardiac output responses to an orthostatic challenge. We have used in vitro vascular reactivity assays to explore abnormalities in vascular responses in vessels from HLU animals and, cardiac output (CO), blood pressure (BP) and heart rate (HR) measurements to characterize changes in hemodynamics following HLU.

Shoukas, Artin A.↗

Numerical simulation of the influence of gravity and posture on cardiac performance

A numerical model of the cardiovascular system was used to quantify the influences on cardiac function of intrathoracic pressure and intravascular and intraventricular hydrostatic pressure, which are fundamental biomechanical stimuli for orthostatic response. The model included a detailed arterial circulation with lumped parameter models of the atria, ventricles, pulmonary circulation, and venous circulation. The venous circulation was divided into cranial, central, and caudal regions with nonlinear compliance. Changes in intrathoracic pressure and the effects of hydrostatic pressure were simulated in supine, launch, sitting, and standing postures for 0, 1, and 1.8 G. Increasing intrathoracic pressure experienced with increasing gravity caused 12% and 14% decreases in cardiac output for 1 and 1.8 G supine, respectively, compared to 0 G. Similar results were obtained for launch posture, in which the effects of changing intrathoracic pressure dominated those of hydrostatic pressure. Compared to 0 G, cardiac output decreased 0.9% for 1 G launch and 15% for 1.8 G launch. In sitting and standing, the position of the heart above the hydrostatic indifference level caused the effects of changing hydrostatic pressure to dominate those of intrathoracic pressure. Compared to 0 G, cardiac output decreased 13% for 1 G sitting and 23% for 1.8 G sitting, and decreased 17% for 1 G standing and 31% for 1.8 G standing. For a posture change from supine to standing in 1 G, cardiac output decreased, consistent with the trend necessary to explain orthostatic intolerance in some astronauts during postflight stand tests. Simulated lower body negative pressure (LBNP) in 0 G reduced cardiac output and mean aortic pressure similar to I G standing, suggesting that LBNP provides at least some cardiovascular stimuli that may be useful in preventing postflight orthostatic intolerance. A unifying concept, consistent with the Frank-Starling mechanism of the heart, was that cardiac output was proportional to cardiac diastolic transmural pressure for all postures and gravitational accelerations.

Non-NASA Center↗