Search NASA⌕ Search

SEARCH · Search NASA

Results for “Static air temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

JTAGG II Brush Seal Test Results

The Tri-services JTAGG 2 engine uses two identical brush seals, in tandem, located aft of the high pressure compressor. The engine operating conditions, at intermediate rated power (IRP), for this seal are estimated to be 50,000 rpm (899 ft/sec) speed, 175 psid air to air pressure differential and 1200 F air temperature. The testing was comprised of static air leakage, performance, seal offset, rotor run out tests and a 50 hr endurance test in the NASA Lewis seal rig. Based on the test results, it is concluded that the brush seal design should be able to meet the air leakage flow factor goal of less than 0.004 for the engine IRP operating conditions. For the 4.12 in. i.d. labyrinth seal, 0.005 in. typical radial clearance, at the JTAGG 2 operating conditions, the leakage flow factor is 0.007. The long term seal life can not be predicted accurately due to the limited endurance testing of 50 hr. However, based on the excellent condition of the test seal and rotor after 50 hr of testing, it is anticipated that the seals should easily meet the JTAGG 2 engine test requirement.

Arora, Gul K.↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva↗

Effects of test facility contaminants on supersonic hydrogen-air diffusion flames

Results are presented from an analytical assessment of the effects of NO and H2O in air on the ignition and reaction of hydrogen. Three flow models of the burning process were used, each including a 32 reaction chemistry mechanism. These models were a plug flow reactor to determine ignition and reaction times; a well-stirred reactor to assess flame stability or blow-off; and a parabolic Navier-Stokes code to examine the diffusion flame combustion. The diffusion flame was computed for a cold supersonic H2 jet coaxial with a supersonic air stream at a static temperature of 1100 K and a pressure of 1 atmosphere.

Rogers, R. Clayton↗

Effects of test facility contaminants on supersonic hydrogen-air diffusion flames

Results are presented from an analytical assessment of the effects of NO and H2O in air on the ignition and reaction of hydrogen. Three flow models of the burning process were used, each including a 32 reaction chemistry mechanism. These models were a plug flow reactor to determine ignition and reaction times; a well-stirred reactor to assess flame stability or blow-off, and a parabolic Navier Stokes code to examine the diffusion flame combustion. The diffusion flame was computed for a cold supersonic H2 jet coaxial with a supersonic air stream at a static temperature of 1100 K and a pressure of 1 atmosphere.

Rogers, R. Clayton↗

Species and velocity visualization of unseeded heated air and combusting hydrogen jets using laser and flashlamp sources

Three techniques for the visualization of species and/or velocity in unseeded H2/air flames and heated air jets are described and preliminary image data are presented. The techniques described are: (1) simultaneous ArF laser imaging of H2, O2, and Rayleigh cross-section weighted density in an H2, O2, and Rayleigh cross-section weighted density in an H2/air flame; (2) ultraviolet flashlamp imaging of O2, OH, and Rayleigh cross-section weighted density in an H2/air flame; and (3) Raman Excitation plus Laser Induced Electronic Fluorescence velocimetry in heater air flows, up to static temperatures of 700 K. Application of these techniques, individually or in combination, should provide useful insight into mixing and reacting flows containing H2, O2, N2 and reaction intermediates such as OH.

Diskin, Glenn S.↗

Experimental Investigation of a Five-stage Axial-flow Research Compressor with Transonic Rotors in All Stages III : Interstage Data and Individual Stage Performance Characteristics

For use in computing the detailed performance parameters of individual blade rows of a multistage compressor, radial distributions of total pressure, total temperature, static pressure and air-flow angle are tabulated. The data cover a range of air flow from choke to the approximate surge limit for equivalent rotor speeds from 70 to 100 percent of design. Equivalent stage performance curves determined from the radial survey measurements indicate both the individual performance and the matching of the stages at the speeds investigated.

Sandercock, Donald M↗

BOREAS AFM-2 Wyoming King Air 1994 Aircraft Sounding Data

The BOREAS AFM-2 team used the University of Wyoming King Air aircraft during IFCs 1, 2, and 3 in 1994 to collected pass-by-pass fluxes (and many other statistics) for the large number of level (constant altitude), straight-line passes used in a variety of flight patterns over the SSA and NSA and areas along the transect between these study areas. The data described here form a second set, namely soundings that were incorporated into nearly every research flight by the King Air in 1994. These soundings generally went from near the surface to above the inversion layer. Most were flown immediately after takeoff or immediately after finishing the last flux pattern of that particular day's flights. The parameters that were measured include wind direction, wind speed, west wind component (u), south wind component (v), static pressure, air dry bulb temperature, potential temperature, dewpoint, temperature, water vapor mixing ratio, and CO2 concentration. Data on the aircraft's location, attitude, and altitude during data collection are also provided. These data are stored in tabular ASCH files. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Kelly, Robert D.↗

Uncertainty Analysis of the NASA Glenn 8- by 6-Foot Supersonic Wind Tunnel 2019 Characterization Test 14-Foot, 5.8 Percent Test Section Porosity

This paper presents methods and results of a measurement uncertainty analysis that was performed for the 8- by 6-foot Supersonic Wind Tunnel located at the NASA Glenn Research Center. The uncertainty analysis is based on data collected during a characterization test following major structural modifications to the facility and upgrades to the facility’s data and control systems. The statistical methods and engineering judgments used to estimate elemental uncertainties are described in this report. The Monte Carlo method of propagating uncertainty was selected to determine the uncertainty of calculated variables of interest. A description of the Monte Carlo method as applied for this analysis is provided. The primary variable of interest (VOI) for this facility is free stream Mach number. In addition to determining the uncertainty in Mach number, the uncertainty in free stream values of static pressure, total pressure, dynamic pressure, total temperature, static temperature, Reynolds number, and air speed were also calculated. Uncertainty results are presented as random (unpredictable variation in repeated measurements), systematic (potential offset between observed and true value), and total (random and systematic combined) uncertainty for Mach number. Systematic uncertainty results are presented for the other VOIs. Individual uncertainty sources are presented both dimensionally and as percent contributions to uncertainty in all VOIs, to aid in the identification of primary uncertainty sources.

Uncertainty Analysis↗

Static and Dynamic Friction Behavior of Candidate High Temperature Airframe Seal Materials

The following report describes a series of research tests to evaluate candidate high temperature materials for static to moderately dynamic hypersonic airframe seals. Pin-on-disk reciprocating sliding tests were conducted from 25 to 843 C in air and hydrogen containing inert atmospheres. Friction, both dynamic and static, was monitored and serves as the primary test measurement. In general, soft coatings lead to excessive static friction and temperature affected friction in air environments only.

Dellacorte, C.↗

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

NOx mediated formation of ε – UO 3 during thermal decomposition of uranyl nitrate hexahydrate under static air conditions

The thermal decomposition of uranyl nitrate hexahydrate in air at temperatures of 650 – 800 °C is expected to yield α – U 3 O 8 through intermediate UO 3 phases. Here, n this study, Raman spectroscopy complimented by powder X-ray diffraction revealed the unexpected formation of ε – UO 3 as an accompanying phase during thermal decomposition of UNH at 700 °C under static air conditions. Experiments demonstrated that ε – UO 3 does not form during the initial ramp up stage nor during the high temperature heating period; but instead forms during the cooling stage between 250 – 400 °C. Additional experiments revealed that UNH initially decomposes through an amorphous UO 3 intermediate prior to α – U 3 O 8 formation. Attempts to bypass the U 3 O 8 precursor in the formation of ε – UO 3 were unsuccessful, supporting the necessity of U 3 O 8 (α – U 3 O 8 in this study) in the formation of ε – UO 3 . The observed phase evolution is proposed to result from the NOx species generated during UNH thermal decomposition, which create localized oxidizing conditions within the furnace under static air conditions. Furthermore, a predominantly phase pure ε – UO 3 was synthesized under static air conditions through the addition of an extra plateau at 250 °C during the cooling step. These findings demonstrate the importance of gas-phase chemistry and cooling conditions in uranium oxide phase evolution and provide additional insight into ε – UO 3 formation pathways.

Epsilon uranium trioxide↗

Summary of the 5th Propulsion Aerodynamics Workshop Nozzle Test Case: Heated Nozzle Exhaust Passing Over A Film-Cooled Plate

This paper summarizes findings from the fifth AIAA Propulsion Aerodynamics Workshop nozzle test case. The experimental configuration examined by workshop participants was a subsonic nozzle with a square exit blowing a heated exhaust over a film-cooled plate. Computational fluid dynamics solutions were obtained and compared to experimental measurements of flow velocities and temperatures, as well as plate surface temperatures. The heated nozzle operated with a Mach 0.3 exit flow at a static temperature ratio of 2.7. Cooling air blowing ratios of 0, 1, and 2 were considered. Computational meshes for the flow domain were provided for participants. Workshop participants from eight separate organizations represented government, industry, and academia. A variety of flow solutions were obtained: Most of the flow solutions employed a Reynolds-averaged Navier-Stokes (RANS) approach, but scale-resolving simulations were used in some cases, including wall-modeled large-eddy simulation (LES), and a few hybrid RANS-LES approaches. One Lattice-Boltzmann solver was employed. For heat transfer to the test article, many participants used a conjugate heat transfer approach. Effects of mesh sensitivity, flow solution approach, and wall heat transfer approach are considered. In general, a fully three-dimensional conjugate heat transfer approach enabled better prediction of surface temperatures than simpler wall temperature boundary treatments. Also, the scale resolving approaches provided better prediction of static temperatures in the flow immediately above the plate consisting of the hot jet exhaust boundary layer interacting with the cooling film. Comparisons of plate surface friction drag and heat transfer obtained from the computations are also presented.

nozzle↗