Search NASA⌕ Search

SEARCH · Search NASA

Results for “Step height”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Flight-measured pressure characteristics of aft-facing steps in thick boundary layer flow for transonic and supersonic Mach numbers

Aft-facing step base pressure flight data were obtained for three step heights for nominal transonic Mach numbers of 0.80, 0.90, and 0.95, and for supersonic Mach numbers of 2.2, 2.5, and 2.8 with a Reynolds number, based on the fuselage length ahead of the step, of about 10 to the 8th power. Surface static pressures were measured ahead of the step, behind the step, and on the step face (base), and a boundary layer rake was used to obtain boundary layer reference conditions. A comparison of the data from the present and previous experiments shows the same trend of increasing base pressure ratio (decreasing drag) with increasing values of momentum thickness to step height ratios. However, the absolute level of these data does not always agree at the supersonic Mach numbers. For momentum thickness to height ratios near 1.0, the differences in the base pressure ratios appear to be primarily a function of Reynolds number based on the momentum thickness. Thus, for Mach numbers above 2, the data analyzed show that the base pressure ratio decreases (drag increases) as Reynolds number based on momentum thickness increases for a given momentum thickness and step height.

Powers, S. G.↗

Limiting Step Bunch Height During Crystal Growth from Flowing Solutions

High precision interferometric studies of step bunching on KDP crystal surface growing from solution moving at rates up to 1 d s . It is shown that the bunch height is limited as the bunch propagates over the surface. An hypothesis is put forward describing why the bunch height decreases as the solution flow rate increases.

Booth, N. A.↗

Heat-transfer and pressure distributions for laminar separated flows downstream of rearward-facing steps with and without mass suction

Heat-transfer and pressure distributions were measured for laminar separated flows downstream of rearward-facing steps with and without mass suction. The flow conditions were such that the boundary-layer thickness was comparable to or larger than the step height. For both suction and no-suction cases, an increase in the step height resulted in a sharp decrease in the initial heat-transfer rates behind the step. Downstream, however, the heat transfer gradually recovered back to less than or near attached-flow values. Mass suction from the step base area increased the local heat-transfer rates; however, this effect was relatively weak for the laminar flows considered. Even removal of the entire approaching boundary layer raised the post-step heat-transfer rates only about 10 percent above the flatplate values. Post-step pressure distributions were found to depend on the entrainment conditions at separation. In the case of the solid-faced step, a sharp pressure drop behind the step was followed by a very short plateau and relatively fast recompression. For the slotted-step connected to a large plenum but without suction, the pressure drop at the base was much smaller and the downstream recompression more gradual than that for solid-faced step.

Brown, R. D.↗

Effect of initial conditions on turbulent reattachment downstream of a backward-facing step

The reattachment of a fully turbulent, two-dimentional shear layer downstream of a backward-facing step has been studied experimentally. The work examines the effect of variations in inlet conditions on the process of reattachment. A series of experiments was conducted in a low-speed wind tunnel using specialized instrumentation suited to the highly turbulent reversing flow near reattachment. Accurate characterization of the time-mean features of the reattaching flows was possible. Assuming linear scaling normalized on distance from reattachment, distributions of normalized pressure coefficient and forward flow fraction, and time-averaged skin friction coefficient appear universal for two-dimensional reattachment, independent of initial conditions and step height, for given duct geometry (area ratio) and for high step-height Reyolds numbers with thin separating boundary layers. The results suggest universal flow structure in the reattachment zone.

Westphal, R. V.↗

Rearward-facing steps in laminar supersonic flows with and without suction.

It was found in the experimental study conducted that, for both suction and no-suction cases, an increase in the step height caused a sharp drop in the initial heating rates which then gradually recovered to less or near the attached-flow values. The height of the step controlled the heating rates at the step base. Mass suction from the separated area increased the local heating rates, the relative increase being most significant immediately behind the step. In general, however, the effect of mass suction on heat-transfer at all laminar flows was relatively weak.

Jakubowski, A. K.↗

Modeling the Effects of a Backward-Facing Step on Boundary-Layer Transition

We model transition to turbulence in a two-dimensional boundary layer downstream of a backward-facing step (BFS) along a flat plate. With the goal of evaluating the available engineering models for predicting the effects of step excrescences on the transition characteristics, two separate methodologies are used to monitor the streamwise shift in the transition onset location as the step height and the flow speed are varied across the range of a previously reported experiment involving step-height-to-local-displacement-thickness ratios of 0 < h/δ* < 1.6. Unlike the variable N -factor method from the previous literature, both of these methods are general in scope and do not involve any empirical correlations that are specific to step excrescences. The first of these techniques involves an N -factor method that directly accounts for the change in boundary-layer instability characteristics due to the step. Stability computations using the harmonic linearized Navier-Stokes equations (HLNSE), which fully account for the nonparallel-mean-flow effects close to the BFS, indicate that the measured transition locations at nearly all test conditions ( h/δ* < 1.3) correlate well with a computed N -factor of N tr = 7.6, demonstrating a successful stability-based transition criterion related to step excrescences. Linear stability theory, which does not account for nonparallel effects, demonstrates reasonable agreement with the HLNSE results, yielding good predictions for the overall trends, but predicts a somewhat earlier onset of transition than HLNSE. The other methodology used in this work involves transport-equation-based transition models. We first show that the Langtry-Menter y - Re θt transition model cannot accurately predict the location of transition onset for moderate BFS heights because it is unable to accurately account for the flow history effects. Along with the Langtry-Menter transition model, we also show the amplification factor transport model does not produce accurate transition locations for subsonic flow over steps even though it accounts for some flow history effects.

Transition↗

Modeling the Effects of a Backward-Facing Step on Boundary-Layer Transition

We model transition to turbulence in a two-dimensional boundary layer downstream of a backward-facing step (BFS) along a flat plate. With the goal of evaluating the available engineering models for predicting the effects of step excrescences on the transition characteristics, two separate methodologies are used to monitor the streamwise shift in the transition onset location as the step height and the flow speed are varied across the range of a previously reported experiment involving step-height-to-local-displacement-thickness ratios of 0 < h/δ* < 1.6. Unlike the variable N -factor method from the previous literature, both of these methods are general in scope and do not involve any empirical correlations that are specific to step excrescences. The first of these techniques involves an N -factor method that directly accounts for the change in boundary-layer instability characteristics due to the step. Stability computations using the harmonic linearized Navier-Stokes equations (HLNSE), which fully account for the nonparallel-mean-flow effects close to the BFS, indicate that the measured transition locations at nearly all test conditions ( h/δ* < 1.3) correlate well with a computed N -factor of N tr = 7.6, demonstrating a successful stability-based transition criterion related to step excrescences. Linear stability theory, which does not account for nonparallel effects, demonstrates reasonable agreement with the HLNSE results, yielding good predictions for the overall trends, but predicts a somewhat earlier onset of transition than HLNSE. The other methodology used in this work involves transport-equation-based transition models. We first show that the Langtry-Menter y - Re θt transition model cannot accurately predict the location of transition onset for moderate BFS heights because it is unable to accurately account for the flow history effects. Along with the Langtry-Menter transition model, we also show the amplification factor transport model does not produce accurate transition locations for subsonic flow over steps even though it accounts for some flow history effects.

Transition↗

Geoid anomalies over two South Atlantic fracture zones

Seasat altimetry profiles across the Falkland-Agulhas and Ascension fracture zones were examined for evidence of step-like geoid offsets predicted from thermal modeling of the lithosphere. Neither the plate nor the half-space model of lithospheric thermal evolution succeeds in predicting the variations in step height with age across the fracture zone branches considered. For ages less than about 30 Ma, the step offsets decrease in a manner suggesting a plate with a thickness of 50-75 km. At greater ages, the offsets show complex behavior that may be due to bathymetric features adjacent to the fracture zones. Similar geoid patterns on opposite branches of the Falkland-Agulhas fracture zone are indicative of processes that act symmetrically on both sides of the Mid-Atlantic Ridge. This is consistent both with small-scale convection occurring beneath the lithosphere and with bathymetric features originally produced along the ridge crest and now located symmetrically on opposite sides of the ridge. The west flank of the Ascension fracture zone displays a regrowth in step height at about 40 Ma consistent with small-scale convection and in agreement with other studies of Pacific and South Atlantic fracture zones.

Freedman, Adam P.↗

Experimental study of flow reattachment in a single-sided sudden expansion

The reattachment of a fully turbulent, two dimensional, separated shear layer downstream of a single-sided sudden expansion in a planar duct flow was examined experimentally. The importance of changing the structure of the separated shear layer on the reattachment process itself was examined. For all cases, the Reynolds number based on step height was greater than 20,000, the expansion ratio was 5/3, and the inlet boundary layer was less than one-half step height in thickness. A crucially important phase was the development of a pulsed wall probe for measurement of skin friction in the reattachment region, thus providing an unambiguous definition of the reattachment length. Quantitative features of reattachment - including streamwise development of the mean and fluctuating velocity field, pressure rise, and skin friction - were found to be similar for all cases studied when scaled by the reattachment length. A definition of the reattachment zone is proposed.

Westphal, R. V.↗

The development and application of the stirred‐reactor coupon analysis (SRCA) test method

A new technique, termed the stirred‐reactor coupon analysis (SRCA) method, has been developed to measure the rate of glass dissolution in forward‐rate conditions. Monolithic glass coupons are partially masked with an inert material before placement in a large volume of well‐mixed solution with known chemistry and temperature for a predetermined duration. After the test, the mask is removed, and the difference in step height between the protected area and the exposed corroded portions of the sample coupon is measured to determine the extent of glass dissolution. The step height is converted to a rate measurement using the test duration and glass density. Test parameters such as sample surface preparation and test duration were evaluated to determine their effects on the measured rates. Additionally, results from an interlaboratory study (ILS) consisting of 12 laboratories from 11 different institutions are presented, where each laboratory performed 12 independent tests. When removing experimental outlier data, the 95% reproducibility limits for the SRCA method has no statistical difference with previously published standardized test methods used to determine the forward rate of glass dissolution. Overall, this paper describes steps necessary to perform the test method and provides the statistical calculations to evaluate test accuracy.

chemical durability↗

An Experimental Study of a Separated/Reattached Flow Behind a Backward-Facing Step. Re(sub h) = 37,000

An experimental study was carried out to investigate turbulent structure of a two-dimensional incompressible separating/reattaching boundary layer behind a backward-facing step. Hot-wire measurement technique was used to measure three Reynolds stresses and higher-order mean products of velocity fluctuations. The Reynolds number, Re(sub h), based on the step height, h, and the reference velocity, U(sub 0), was 37,000. The upstream oncoming flow was fully developed turbulent boundary layer with the Re(sub theta) = 3600. All turbulent properties, such as Reynolds stresses, increase dramatically downstream of the step within an internally developing mixing layer. Distributions of dimensionless mean velocity, turbulent quantities and antisymmetric distribution of triple velocity products in the separated free shear layer suggest that the shear layer above the recirculating region strongly resembles free-shear mixing layer structure. In the reattachment region close to the wall, turbulent diffusion term balances the rate of dissipation since advection and production terms appear to be negligibly small. Further downstream, production and dissipation begin to dominate other transport processes near the wall indicating the growth of an internal turbulent boundary layer. In the outer region, however, the flow still has a memory of the upstream disturbance even at the last measuring station of 51 step-heights. The data show that the structure of the inner layer recovers at a much faster rate than the outer layer structure. The inner layer structure resembles the near-wall structure of a plane zero pressure-gradient turbulent boundary layer (plane TBL) by 25h to 30h, while the outer layer structure takes presumably over 100h.

Jovic, Srba↗

Apron heights around stepped massifs in the Cydonia Mensae region: Do they record the local paleobathymetry of Oceanus Borealis?

The use of photoclinometry and shadow measurements to determine the basin volume without linking the measurements to a global datum is described. Since the boundary, or shoreline, of the basin cannot be tied to the datum and typically has no useful local relative height to measure, what is needed is a number of measurements of the height of the paleoshorelines distributed across the basin. Photoclinometric profiles are being compiled from Viking Orbiter images of the Cydonia Mensae region, which includes images with high sun elevations, necessary to avoid shadows, and images with low sun elevations, to enable the use of shadow measurements as an independent check, at high resolution (40 to 100 m/pixel). Both asymmetric and symmetric photoclinometric profile models are being used, and the results cross checked with one another to minimize errors. An apron-height map, potentially a paleobathymetric map of part of the margin of Oceanus Borealis, can be compiled from this data to determine whether variations in apron height are consistent with a lacustrine interpretation.

Parker, T. J.↗

Microstructural Simulation of Ion-Irradiated Natural Rocks and Minerals

This report details the contribution of Oak Ridge National Laboratory to the Nuclear Energy University Program (NEUP) project, "Rapid Characterization of Concrete Mineralogy using Multi-Scale Tools" led by the University of Illinois at Urbana-Champaign. To support the subsequent license renewal (SLR) of the US nuclear power plants (NPPs) fleet, the performance of concrete-forming aggregates against neutron irradiation needs to be assessed. Ion irradiation is proposed as a rapid, cost-effective surrogate method to full neutron irradiation testing. To complement the characterization of ion-irradiated rock specimens, ORNL has run finite-elements and fast-Fourier transform (FFT-based) simulations using the codes MARS and Microstructure-Oriented Scientific Analysis of Irradiated Concrete (MOSAIC). The main conclusion of this analysis is that the apparent post–ion-irradiation step-height underestimates the accumulated free radiation-induced volumetric expansion (RIVE) in the ion-implanted depth by about 15% at full amorphization and about 25% toward the beginning of the ion irradiation experiment. The discrepancy is explained by the fact that the step height is proportional to the sum of the RIVE (i.e., one third of the RIVE) and the irradiation-assisted plastic strains in the vertical direction (lower than two thirds of the RIVE). Because of the large lateral compressive stresses caused by the restraining effect of the unirradiated substrate, the stress field in the mineral grains and at the grain boundary (GB) in the ion-implanted layer is much different than the comparable stress field occurring during neutron irradiation. Hence, the mismatch RIVE causing cracks in the rock-forming minerals leads to different cracking patterns. Ion irradiation continues to be used as a rapid technique to assess the RIVE potential of rocks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Geometric factors affecting noise suppresion and thrust loss of divergent-lobe supersonic jet noise suppressor

The thrust loss and noise suppression of a divergent-lobe supersonic jet noise suppressor were experimentally determined over a range of nozzle pressure ratios of 1.5 to 4.0. These small-scale cold flow tests were made to determine the effect on thrust and noise of: suppressor length, rearward facing step height, suppressor divergence angle, and ejector shroud length and location. Noise suppression was achieved at nozzle pressure ratios of 2.5 and greater. Maximum lobe jet noise attenuation of 15 db with thrust loss differences of 1.5 percent compared to the convergent nozzle were obtained at a nozzle pressure ratio of 3.5 with an ejector shroud two nozzle diameters long. Without the ejector the attenuation was 13 db with thrust loss differences of 11 percent. Short suppressors approximately one primary nozzle throat diameter long performed as well as longer suppressors. Rearward facing step height had a significant effect on noise suppression. Ejector shrouds two nozzle diameters in length are feasible.

Huff, R. G.↗

Electropolishing parameters study for surface smoothening of low-$\beta$650 MHz five-cell niobium superconducting radio frequency cavity

Electropolishing (EP) is applied to niobium (Nb) superconducting radio frequency (SRF) cavities, which are used in particle accelerators for their surface treatment. The EP process for 1.3 GHz cavities has been extensively studied earlier. In this work, a parametric study on EP of low-β (0.61) 650 MHz Nb SRF cavities (LB650), which will be used in pre-production cryomodule for proton improvement plan-II (PIP-II) linear accelerator, was conducted to determine adequate EP conditions for attaining a smooth surface of the cavities. EP performed with the standard parameters and an initial cathode (cathode-I) having a cathode surface area of ~5% of the cavity surface area yielded a rough equator surface of the cavity. The grain step height on the equator weld position was measured to be ~ 32 μm. The rough surface was attributed to preferential grain etching confirmed by a polarization curve showing a linear relationship between the EP current and voltage and the absence of the current plateau region. The cathode was modified to make its surface area twice that of cathode-I. The modified cathode (cathode-M) provided a current plateau region in the corresponding I-V curves measured at different cavity temperatures. The onset voltage for the plateau was found to be higher at higher cavity temperatures. Here this study revealed that even with cathode-M, the standard 18 V was low for EP of such large-sized cavities when the cavity temperature was 18 °C. EP performed at a higher voltage of 22–24.5 V with cathode-M yielded a smooth surface with a grain step height of only 0.6 μm. The applied EP conditions also improved removal uniformity along the cavity length. In contrast to the cavity treated with cathode-I, the cavities treated with cathode-M achieved a significantly higher accelerating gradient (E acc ) in vertical tests conducted in a cryostat at 2 K. The modified EP was found efficient to produce the cavities that achieved E acc of 22.4 MV/m, required by PIP II project in the baseline RF tests, to qualify for further surface processing used to enhance their quality factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Flameholding characteristics of a swept-strut H2 fuel-injector for scramjet applications

A series of direct-connect tests are conducted which simulate the flow around the center swept-strut fuel-injector of a scramjet engine module. The experimental geometry includes both perpendicular and parallel fuel injectors which are swept with respect to the upstream flow direction in a manner simulating the flow geometry in the combustion region of the scramjet module. Seven different strut injector geometries are evaluated for their performance, flameholding, and inlet-combustor interaction characteristics. The most efficient combustion process is exhibited by the configuration having the deepest step with perpendicular injector orifices located 3.5 to 4.5 step heights downstream from the step. However, long centerbody and staged injection configurations perform as equally well as the deep step configuration when evaluating only the amount of perpendicular fuel injection. Since the staged injection configuration exhibits the lowest ignition and flameholding limit, it is suggested that the optimum injection configuration should incorporate a deep step with staged injection in order to improve the low temperature autoignition-flameholding characteristics.

Northam, G. B.↗

Numerical predictions of residence times behind a rearward facing step with transverse injection

A numerical investigation of the two-dimensional recirculation zone formed between a rear-ward facing step and a transverse hydrogen jet in a supersonic flow is presented. Calculations were made using an elliptic flow computer code with a time-relaxation finite difference integration algorithm. Cases were examined for jet static pressures between 2 and 5 times mainstream with jets located 3 to 7 step heights downstream of the step. Nominal mainstream flow conditions were Mach 2.4 air at 1 atm pressure and 1000K (1800R) static temperature. Results in the form of mean properties in the recirculation zone and residence time are presented. Calculations of the decay of hydrogen mass from the steady state are presented for selected cases. The combustion potential for each case is assessed by comparison of computed conditions in the recirculation zone with the results from a well-stirred reactor theory.

Rogers, R. C.↗

Numerical predictions of residence times behind a rearward facing step with transverse injection

A numerical investigation of the two-dimensional recirculation zone formed between a rearward facing step and a transverse hydrogen jet in a supersonic flow is presented. Calculations were made using an elliptic flow computer code with a time-relaxation finite difference integration algorithm. Cases were examined for jet static pressures between 2 and 5 times mainstream with jets located 3 to 7 step heights downstream of the step. Nominal mainstream flow conditions were Mach 2.4 air at 1 atm pressure and 1000 K (1800 R) static temperature. Results in the form of mean properties in the recirculation zone and residence time are presented. Calculations of the decay of hydrogen mass from the steady state are presented for selected cases. The combustion potential for each case is assessed by comparison of computed conditions in the recirculation zone with the results from a well-stirred reactor theory.

Rogers, R. C.↗