Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sterile or Heavy Neutrinos”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Replacement of Cobalt in Medical Device Sterilization: Current Trends, Opportunities and Barriers to Adoption of X-ray and E-Beam Within the Medical Device Sterilization Market

Radioactive sources, specifically Co-60, are crucially important to the medical device sterilization industry; however, their benefits must be balanced against the need to ensure that the materials are secure. Accelerator-based sterilization methods, including X-ray and E-Beam, can in many cases sufficiently replace Co-60 and ethylene oxide, the dominant modalities currently in use; however, a lack of hands-on experience with accelerators, regulations, and a lack of capacity have hampered faster adoption of these technologies. The market is likely to change, however, given public pressures against ethylene oxide and concerns over the cost and long-term supply chain robustness of Co-60. This may provide an opportunity for growth for accelerator capabilities. Current research at Sandia National Laboratories and Argonne National Laboratory, on behalf of the Department of Energy’s National Nuclear Security Administration Office of Radiological Security, is focused on developing an understanding of the medical device sterilization marketplace, the different modalities that are used to sterilize goods, and the drivers that affect the actors within it. Research at Pacific Northwest National Laboratory, in conjunction with the medical device sterilization industry, has focused on expanding the industry’s understanding of the capabilities of X-ray sterilization and developing data that can inform the industry’s consideration of a transition towards accelerator-based devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Primordial black hole sterile neutrinogenesis: sterile neutrino dark matter production independent of couplings

Abstract Sterile neutrinos (ν s s) are well-motivated and actively searched for hypothetical neutral particles that would mix with the Standard Model active neutrinos. They are considered prime warm dark matter (DM) candidates, typically when their mass is in the keV range, although they can also be hot or cold DM components. We discuss in detail the characteristics and phenomenology ofν s s that minimally couple only to active neutrinos and are produced in the evaporation of early Universe primordial black holes (PBHs), a process we called “PBH sterile neutrinogenesis”. Contrary to the previously studiedν s production mechanisms, this novel mechanism does not depend on the active-sterile mixing. The resultingν s s have a distinctive spectrum and are produced with larger energies than in typical scenarios. This characteristic enablesν s s to be WDM in the unusual 0.3 MeV to 0.3 TeV mass range, if PBHs do not matter-dominate the Universe before evaporating. When PBHs matter-dominate before evaporating, the possible coincidence of induced gravitational waves associated with PBH evaporation and astrophysical X-ray observations fromν s decays constitutes a distinct signature of our scenario.

Astronomy & Astrophysics↗

Teaching sterile neutrinos in an undergrad laboratory: a sterile-neutrino search using data from the MicroBooNE liquid-argon time projection chamber performed in an undergraduate teaching laboratory

Dataset associated with "A sterile-neutrino search using data from the MicroBooNE liquid-argon time projection chamber performed in an undergraduate teaching laboratory" an educational paper to teach data analisys within particle physics for 3-4 yr physics major undergrads. Data format are csv, h5 and pkl

Gramellini, Elena [Manchester U.] (ORCID:000000031↗

Probing Heavy Majorana Neutrinos and the Weinberg Operator through Vector Boson Fusion Processes in Proton-Proton Collisions at s = 13 TeV

The first search exploiting the vector boson fusion process to probe heavy Majorana neutrinos and the Weinberg operator at the LHC is presented. The search is performed in the same-sign dimuon final state using a proton-proton collision dataset recorded at s = 13 TeV , collected with the CMS detector and corresponding to a total integrated luminosity of 138 fb -1 . The results are found to agree with the predictions of the standard model. For heavy Majorana neutrinos, constraints on the squared mixing element between the muon and the heavy neutrino are derived in the heavy neutrino mass range 50 GeV–25 TeV; for masses above 650 GeV these are the most stringent constraints from searches at the LHC to date. A first test of the Weinberg operator at colliders provides an observed upper limit at 95% confidence level on the effective $μμ$ Majorana neutrino mass of 10.8 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Population Transfer Mechanism for Sterile Neutrino Dark Matter

We present a mechanism for producing a cosmologically significant relic density of one or more sterile neutrinos. This scheme invokes two steps: First, a population of “heavy” sterile neutrinos is created by scattering-induced decoherence of active neutrinos. Second, this population is transferred, via sterile neutrino self-interaction-mediated scatterings and decays, to one or more lighter mass (∼10 keV to ∼1 GeV) sterile neutrinos that are far more weakly (or not at all) mixed with active species and could constitute dark matter. Dark matter produced this way can evade current electromagnetic and structure-based bounds, but may nevertheless be probed by future observations.

Dark matter↗

Neutrino Dipole Moments and Radiative Signatures from Partial Compositeness

We investigate composite neutrino models where heavy neutrinos emerge as bound states from a near-conformal strongly coupled sector. Standard Model neutrinos mix with these composite singlets via an inverse seesaw mechanism, where the anomalous scaling dimensions of the composite-sector operators naturally suppress light neutrino masses to sub-eV scales. Matching the conformal dynamics onto low-energy theory yields enhanced electromagnetic transition dipole operators with couplings $d_{μN} \sim 10^{-6}$-$10^{-8}\,\mathrm{GeV}^{-1}$, parametrically larger than the loop-level predictions of minimal Dirac or Majorana models. We carry out a dedicated event-level simulation of the production-and-decay chain $νX \to \mathcal{U} X \to νγX$ and compute the resulting event rates at MiniBooNE and MINERvA within the model, accounting for the composite production cross section and decay kinematics in detail. We further present predictions for the photon energy, angular, and multiplicity distributions. For the benchmark scenarios accessible at these experiments the radiative signal is predominantly single-photon; the composite structure additionally permits fragmentation of the up-scattered state into multiple heavy neutrinos, each decaying as $N\toνγ$, with multi-photon final states emerging for lighter compositeness scales or higher beam energies as a qualitatively new probe of the composite dynamics.

Assi, Benoît [Cincinnati U.; Fermilab] (ORCID:0000↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

Elucidating the mechanisms of enhanced lignin bioconversion by an alkali sterilization strategy

Biological lignin valorization represents an emerging green approach to upgrade lignin for sustainable and economic biorefineries. However, lignin generally exhibits poor water solubility and inhomogeneous distribution in an aqueous medium, significantly limiting its bioconversion efficiency. Herein, we develop a novel alkali sterilization strategy to effectively enhance the dispersion and fermentation performance of lignin substrates. The colloidal particle size and molecular structure variations of lignin during the sterilization were thoroughly investigated to reveal the mechanisms of enhanced fermentation performance. Results showed that alkali sterilization achieved a completely aseptic effect when mixing lignin medium at an initial pH of 12.7 for 24 h. Dynamic light scattering (DLS) analysis demonstrated that the hydrodynamic volume of colloidal lignin particles decreased by 96.3% by alkali sterilization compared with the conventional thermal sterilization. Moreover, lignin characterizations by nuclear magnetic resonance (NMR) spectroscopy and gel permeation chromatography (GPC) suggested that alkali sterilization modified the lignin molecular structure by generating 50% more hydrophilic carboxyl groups, reducing the weight-average molecular weight (M w ) by 23.0%, and narrowing the molar-mass dispersity (D M ) by 23.8%. The generation of lignin substrates with more uniform distribution and lower molecular weight improved Rhodococcus opacus PD630 cell growth and metabolism. Microbial cell amount, lignin degradation, and lipid production in alkali sterilized medium increased by 309%, 30.3%, and 48.3%, respectively, compared to those in thermally sterilized medium. These results clearly demonstrated that alkali sterilization dramatically improved the lignin bioconversion performance. Furthermore, this work presents a facile and effective sterilization strategy to overcome inhomogeneous lignin distribution in aqueous fermentation media, showing great potentials as a platform technique for promoting biological lignin valorization.

59 BASIC BIOLOGICAL SCIENCES↗

Probing mass orderings in presence of a very light sterile neutrino in a liquid argon detector

Results from experiments like LSND and MiniBooNE hint towards the possible presence of an extra eV scale sterile neutrino. The addition of such a neutrino will significantly impact the standard three flavor neutrino oscillations. In particular, it can give rise to additional degeneracies due to additional sterile parameters. For an eV scale sterile neutrino, the cosmological constraints dictate that the sterile state is heavier than the three active states. However, for lower masses of sterile neutrinos, the sterile state can be lighter than one and/or more of the three states. In such cases, the mass ordering of the sterile neutrinos also becomes unknown, along with the mass ordering of the active states. In this paper, we explore the mass ordering sensitivity in the presence of a sterile neutrino assuming the mass squared difference |Δ 41 | to be in the range 10 –4 –1 eV 2 . We study (i) how the ordering of the active states, i.e. the determination of the sign of Δ 31 gets affected by the presence of a sterile neutrino in the above mass range, (ii) the possible determination of the sign of Δ 41 for Δ 41 in the range 10 –4 –0.1 eV 2 . This analysis is done in the context of a liquid argon detector using beam neutrinos traveling a distance of 1300 km and atmospheric neutrinos that propagate through a distance ranging from 10 – 10000 km, allowing resonant matter effects. Apart from presenting separate results from these sources, we also do a combined study and probe the synergy between these two in giving an enhanced sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for heavy Majorana neutrinos in e ± e ± and e ± μ ± final states via WW scattering in pp collisions at s = 13 TeV with the ATLAS detector

A search for heavy Majorana neutrinos in scattering of same-sign W boson pairs in proton–proton collisions at $\sqrt{s}$ = 13 TeV at the LHC is reported. The dataset used corresponds to an integrated luminosity of 140 fb -1 , collected with the ATLAS detector during 2015–2018. The search is performed in final states including a same-sign ee or eμ pair and at least two jets with large invariant mass and a large rapidity difference. No significant excess of events with respect to the Standard Model background predictions is observed. The results are interpreted in a benchmark scenario of the Phenomenological Type-I Seesaw model. New constraints are set on the values of the |V eN | 2 and |V eN V$^{*}_{μN}$| parameters for heavy Majorana neutrino masses between 50 GeV and 20 TeV, where V ℓN is the matrix element describing the mixing of the heavy Majorana neutrino mass eigenstate with the Standard Model neutrino of flavour ℓ = e,μ. The sensitivity to the Weinberg operator is investigated and constraints on the effective ee and eμ Majorana neutrino masses are reported. The statistical combination of the ee and eμ channels with the previously published μμ channel is performed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

System for sterilizing objects

A system for producing a stream of humidified sterilizing gas for sterilizing objects such as the water systems of space vehicles and the like includes a source of sterilant gas which is fed to a mixing chamber which has inlet and outlet ports. The level of the water only partially fills the mixing chamber so as to provide an empty space adjacent the top of the chamber. A heater is provided for heating the water in the chamber so as to produce a humidified atmosphere. The sterilant gas is fed through an arcuate shaped tubular member connected to the inlet port of the mixing chamber for producing a vortex type of flow of sterilant gas into the chamber for humidification. A tubular member extends from the mixing chamber for supplying the humidified sterilant gas to the object for being sterilized. Scrubbers are provided for removing the sterilant gas after use.

Bryan, C. J.↗

Ultrashort Pulse Laser Surface Processing Techniques for Sterilization of Metal Surfaces for Planetary Protection

To prevent forward contamination from microbes aboard spacecraft intended to search for extraterrestrial life, there is a need for effective sterilization methods. However, current techniques are both time-consuming and expensive. For example, dry heat sterilization requires removal from the assembly site and several days of treatment. Furthermore, some components such as optics and electronics are not compatible with current sterilization techniques. Here, we report the latest results in our development of a novel femtosecond laser processing technique for the rapid sterilization of spacecraft hardware. Femtosecond lasers produce extremely high photon fluxes (10^29 photons/sec*cm^2, ~0.03 J/cm^2) in extremely short pulses, which can inactivate even stress-tolerant microbial spores with minimal damage to the spacecraft surface. Aluminum coupons were inoculated with specific densities of Bacillus subtilis bacterial endospores. These coupons were treated with various laser illumination parameters. Afterward, metal coupon samples were assayed for viable spores using a polyvinyl alcohol (PVA) peel, serial dilution, and plating for colony-forming units (CFU). Results indicate that with high enough energy density and pulse counts, most bacterial spores are inactivated with minimal damage to the metal. The sterilization is dependent on both the fluence and pulse count. In addition, femtosecond pulses are more effective than longer pulses for inactivation. These experiments have consistently achieved 4-log reduction in viable spores. Sterilization has been achieved on both flat metal coupons and non-flat surfaces with microchannels, with a slight reduction in sterilization efficiency on the uneven surface. The application of air flow during laser processing was also investigated as a way to remove spores that are dislodged from the surface by the laser illumination, which would contribute to the reduction of spacecraft bioburden. With laser processing technology rapidly evolving, our results support the possibility of an extremely rapid, in-situ surface sterilization method for use in spacecraft assembly clean rooms.

Kaleb McQuillan↗

General approach to neutrino mass mechanisms with sterile neutrinos

We present a mathematical framework for constructing the most general neutrino mass matrices that yield the observed spectrum of light active neutrino masses in conjunction with arbitrarily many heavy sterile neutrinos, without the need to assume a hierarchy between Dirac and Majorana mass terms. The seesaw mechanism is a byproduct of the formalism, along with many other possibilities for generating tiny neutrino masses. We comment on phenomenological applications of this approach, in particular deriving a mechanism to address the long-standing ( g − 2 ) μ anomaly in the context of the left-right symmetric model. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗