Search NASA⌕ Search

SEARCH · Search NASA

Results for “Struts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

DETERMINATION OF STRUT QUALITY FACTORS IN ADDITIVELY MANUFACTURED LATTICES USING IN-SITU COMPRESSION TESTING µ-CT

In response to the need for an automated, commercial method to qualify additively manufactured (AM) lattice components, an experiment was conducted to evaluate the effects of defective lattice struts on the structural compression strength. Lattice samples with known defective or missing struts were compressed using a Deben CT5000RT and imaged using xray µ-CT. The compressive force and x-ray computed tomography results were compared to defect free standards to evaluate the impact of each defect type on the overall structure’s compressive strength. This analysis will allow for simplifications to Finite Element Analysis (FEA) on AM parts without sacrificing model fidelity. Understanding the contribution of each defect type and severity will also better inform non-destructive evaluation (NDE) personnel of the inspection parameters necessary to detect the smallest feature of importance.

Dinova, Vincent A.↗

Initial Clinical Experience With the Strut-Adjusted Volume Implant (SAVI) Breast Brachytherapy Device for Accelerated Partial-Breast Irradiation (APBI): First 100 Patients With More Than 1 Year of Follow-Up

Purpose: The Strut-Adjusted Volume Implant (SAVI; Cianna Medical, Aliso Viejo, CA) is a multichannel single-entry brachytherapy device designed to allow dose modulation to minimize normal tissue dose while simultaneously maximizing target coverage. This is the first report on the initial 102 patients with nearly 2 years of median follow-up. Methods and Materials: One hundred two patients were treated at two institutions. Data were collected on eligibility and dosimetry and followed for toxicity and recurrence. Results: The median follow-up is 21 months. Overall dosimetry is outstanding (median percent of target volume receiving 90% of the prescription dose was 95.9%, volume of target receiving 150% of the prescription dose was 27.8 mL, and volume of target receiving 200% of the prescription dose was 14.0 cm{sup 3}). No devices were pulled prior to treatment completion. For patients with a skin bridge of less than 7 mm, the maximum median skin dose was 280 cGy (median percent of target volume receiving 90% of the prescription dose was 95.2%, volume of target receiving 150% of the prescription dose was 25.8 cm{sup 3} and volume of target receiving 200% of the prescription dose was 12.7 mL). For patients with both chest wall and skin of less than 7 mm, the maximum median lung dose was 205 cGy with simultaneous skin dose of 272 cGy. The rate of telangiectasia was 1.9%. Grade 1 hyperpigmentation developed in 10 patients (9.8%) and Grade 2 fibrosis in 2 patients (1.9%). There were 2 symptomatic seromas and 2 cases of asymptomatic fat necrosis (1.9%). Of the patients, 27% were not eligible for MammoSite balloon brachytherapy (Hologic, Inc., Marlborough, MA) and 5% were not eligible for any balloon brachytherapy. The recurrence rate was 1%. Conclusions: The SAVI appears to safely allow an increase in eligibility for APBI over balloon brachytherapy or three-dimensional conformal radiation, highlighting the outstanding device flexibility to maximize the target dose and minimize the normal tissue dose. The device was well tolerated by patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Dosimetric Differences in Strut-Adjusted Volume Implant Treatment Plans Calculated With TG-43 Formalism and a Model-Based Dose Calculation Algorithm

To comprehensively characterize dosimetric differences between calculations with a commercial model-based dose calculation algorithm (MBDCA) and the TG-43 formalism in application to accelerated partial breast irradiation (APBI) with the strut-adjusted volume implant (SAVI) applicator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRA-14: Optimization of Dosimetric Guidelines for Accelerated Partial Breast Irradiation (APBI) Using the Strut-Adjusted Volume Implant (SAVI)

Purpose: Treatment planning guidelines for accelerated partial breast irradiation (ABPI) using the strut-adjusted volume implant (SAVI) are inconsistent between the manufacturer and NSABP B-39/RTOG 0413 protocol. Furthermore neither set of guidelines accounts for different applicator sizes. The purpose of this work is to establish guidelines specific to the SAVI that are based on clinically achievable dose distributions. Methods: Sixty-two consecutive patients were implanted with a SAVI and prescribed to receive 34 Gy in 10 fractions twice daily using high dose-rate (HDR) Ir-192 brachytherapy. The target (PTV-EVAL) was defined per NSABP. The treatments were planned and evaluated using a combination of dosimetric planning goals provided by the NSABP, the manufacturer, and our prior clinical experience. Parameters evaluated included maximum doses to skin and ribs, and volumes of PTV-EVAL receiving 90%, 95%, 100%, 150%, and 200% of the prescription (V90, etc). All target parameters were evaluated for correlation with device size using the Pearson correlation coefficient. Revised dosimetric guidelines for target coverage and heterogeneity were determined from this population. Results: Revised guidelines for minimum target coverage (ideal in parentheses): V90≥95%(97%), V95≥90%(95%), V100≥88%(91%). The only dosimetric parameters that were significantly correlated (p<0.05) with device size were V150 and V200. Heterogeneity criteria were revised for the 6–1 Mini/6-1 applicators to V150≤30cc and V200≤15cc, and unchanged for the other sizes. Re-evaluation of patient plans showed 90% (56/62) met the revised minimum guidelines and 76% (47/62) met the ideal guidelines. All and 56/62 patients met our institutional guidelines for maximum skin and rib dose, respectively. Conclusions: We have optimized dosimetric guidelines for the SAVI applicators, and found that implementation of these revised guidelines for SAVI treatment planning yielded target coverage exceeding that required by existing guidelines while preserving heterogeneity constraints and minimizing dose to organs at risk.

60 APPLIED LIFE SCIENCES↗

SU-E-T-487: Impact of Geometric Uncertainties in Accelerated Partial Breast Irradiation Using the Strut-Adjusted Volume Implant (SAVI)

Purpose: Single-entry multi-catheter devices have been developed for accelerated partial breast irradiation (APBI). Rotational and translational uncertainties are usually mitigated by quality assurance, however its actual dosimetric impact has not been addressed, which is presented here for SAVI applicator. Methods: Under Institutional Review Board exemption status, we retrospectively analyzed 48 APBI treatment plans using SAVI applicator. For quick calculation of dose-volume histogram (DVH) considering geometric uncertainties, the coordinate of each voxel of critical organs after rotation or translation along the central catheter was calculated using an in-house software instead of rotating or translating the entire dose distribution. Results: For most cases, the skin doses increased with rotation to both directions. At 10 degree of rotation, the increase of Dmax (percent prescribed dose) at 50% (median), 75%, 90%, and 100% (maximum) percentile were 0.3%, 1.7%, 5.6% and 25.0%, respectively. The increase of chest wall Dmax at 50%, 75%, 90%, and 100% percentile were 0.1%, 1.0%, 10.3% and 38.8%, respectively. The increase of skin Dmax of the patients with the distance between skin surface and lumpectomy cavity surface ≤16 mm was significantly larger than those with the distance >16 mm. Similarly, patients with the distance between lung and lumpectomy cavity surface ≤20 mm showed higher sensitivity of chest wall Dmax against rotation than patients with the distance <20 mm. Translation of the applicator showed larger impact on the skin dose than rotation, although the effects on chest wall was less than 2% even at 10 mm displacement. At 5 mm of translation, increase of skin Dmax at 50%, 75%, 90%, and 100% percentile were 2.3%, 8.0%, 15.3% and 77.7%, respectively. Conclusion: The impacts of the geometric uncertainties (rotation and translation) of SAVI applicator were investigated. The skin-lumpectomy cavity and lung-lumpectomy cavity distances showed significant relationship with skin and chest wall doses, respectively.

60 APPLIED LIFE SCIENCES↗

Experimental investigation of heat treatments on the mechanical performance of grade 300 maraging steel strut-based lattices

Lightweight and strong components are essential for reducing energy consumption and enhancing efficiency. Lattice structures are one such geometry utilized to achieve weight reduction. This study investigates the mechanical properties of various lattice structures fabricated from Maraging Steel (EOS MS1) using the Direct Metal Laser Sintering (DMLS) method. The samples include three distinct cellular geometries: body-centered cubic (BCC), face-centered cubic (FCC), and octet truss configurations, which are subjected to tensile and compressive tests. The primary goal of this research is to evaluate the impact of heat treatment on the mechanical properties of cellular architecture under tensile and compressive loading conditions. Destructive, nondestructive testing, and simulation results were also obtained from different heat treatment processes. It was found that the age-hardened specimens performed the best overall in terms of ultimate tensile/compressive strength and elongation. The top-performing topologies in compression and tension were found to be the octet structure, as they were able to withstand the most loading and straining when compared to the other specimens.

Engineering↗

Microstructural characterization of in situ MXCT images of high density foams under large strains

Foams are used in numerous applications, such as vibration damping and energy mitigation (e.g., packaging and helmets), wherein their mechanical properties are of critical importance. A typical compressive response of a high density elastomeric foam, shown in Fig 1, generally contains three regions of interest: (I) a linear-elastic region, governed by strut bending; (II) a relatively flat, or slowly increasing stress-strain response, accompanied by strut buckling and the localized collapse of pores; and (III) an exponentially increasing stress-strain curve wherein the collapse of the pore matrix leads to densification. Two material properties of interest, upon which considerable research has focused are the foam's Young's modulus, E{sub f}, defined as the slope of the stress-strain response in region I, and the collapse stress, {sigma}{sub f}, defined as the stress at which the response begins to deviate from linearity. It has been observed [1, 2, 3] that Young's modulus and the collapse stress are dependent on the material properties of the strut material and the non-dimensional relative-density of the foam, {rho}* = {rho}{sub f}/{rho}{sub m}, where {rho}{sub r} is the gross density of the foam and {rho}{sub m} is the density of the strut, or matrix, material. For foam of low relative-density, i.e, {rho}* < 0.1, the collapse stress and Young's modulus obey the relations {sigma}{sub c}/E{sub m} {proportional_to} ({rho}*){sup m} and E{sub f}/E{sub m} {proportional_to} ({rho}*){sup n} where E{sub m} is Young's modulus of the strut material and the bounds on the parameters m and n are 0.05 {le} m {le} 0.2 and 1 {le} n {le} 4 [4]. For open-celled foams, n = 2, whereas for closed-celled foams, n = 3. Theoretically, n = 1 for foams with an ''ideal strut'' configuration [6]. Foams of high relative-density ({rho}* > 0.1) require correcting terms to account for the axial contributions of the ''thick'' struts [5]. The above equations relate important foam properties to the relative-density of the foam; however, there exists a gap in the understanding of how the foam microstructure affects the mechanical response of the foam. This is due in large part to the difficulty of characterizing foam structures in 3D, especially foams of high relative-density. Most elastomeric foams are manufactured by the introduction of a gas into a cross-linking polymer. The developing foam microstructure has a complex dependence on the polymer viscosity and rate of polymerization, resulting in a randomly arranged pore structure with a large distribution of pore sizes. One approach is to characterize foam microstructures solely in terms of the cross-sectional shape and vector arrangement of the strut matrix, since it is this matrix that supports the stresses upon loading of the foam; yet as the density of a foam is increased, the very definition of what constitutes a strut brakes down. Another, perhaps easier to visualize, characterization of foam microstructure can come from a description of the pore shape and arrangement. Given the random nature of the microstructures of blown foam, both approaches are useful and valid. This paper describes our work aimed at linking the mechanical response and microstructural evolution of high relative-density foam as it undergoes large deformation. This work consists of several inter-related parts, including (i) measuring the compressive stress-strain response, as illustrated in Fig. 1, (ii) obtaining in situ micro X-ray computed tomography (MXCT) images of high relative-density foams undergoing large strains, and (iii) developing mathematical, computer aided, methodologies to perform image analysis and calculations of parameters that characterize the pores and struts. By using MXCT, a non-invasive technique for imaging the internal structure of materials, we are able to observe, internally, individual struts and pores as they undergo large deformation. Here we describe our computer aided image analysis methodologies and present examples of their application to the MXCT images of foams. Operations of the computer program include noise removal (smoothing), thresholding [7], edge detection [8], distance transformation [9, 10], pore detection via a Hough transformation [11], and skeletonization [12]. Strut parameters, such as the strut cross-sectional area and strut arrangement, are calculated from a skeleton-based model of the MXCT images. The Hough transform is a feature detection method used primarily in image analysis applications. We use this transform to detect and calculate pore parameters, such as pore arrangement and pore size distribution. The experiments and calculations are performed in order to develop data for the formulation of theory that links foam mechanical behavior specifically to the microstructure of high relative-density foams, not just simply to the relative-density of the foam.

36 MATERIALS SCIENCE↗

CMC vane assembly apparatus and method

A metal vane core or strut (64) is formed integrally with an outer backing plate (40). An inner backing plate (38) is formed separately. A spring (74) with holes (75) is installed in a peripheral spring chamber (76) on the strut. Inner and outer CMC shroud covers (46, 48) are formed, cured, then attached to facing surfaces of the inner and outer backing plates (38, 40). A CMC vane airfoil (22) is formed, cured, and slid over the strut (64). The spring (74) urges continuous contact between the strut (64) and airfoil (66), eliminating vibrations while allowing differential expansion. The inner end (88) of the strut is fastened to the inner backing plate (38). A cooling channel (68) in the strut is connected by holes (69) along the leading edge of the strut to peripheral cooling paths (70, 71) around the strut. Coolant flows through and around the strut, including through the spring holes.

42 ENGINEERING↗

Multi-Defect Detection in Additively Manufactured Lattice Structures Using 3D Electrical Resistance Tomography

Cellular lattice structures possess high strength-to-weight ratios suitable for advanced lightweight engineering applications. However, their quality and mechanical performance can degrade because of defects introduced during manufacturing or in-service. Their complexity and small length scale features make defects difficult to detect using conventional nondestructive evaluation methods. Here we propose a current injection-based method, electrical resistance tomography (ERT), that can be used to detect damaged struts in conductive cellular lattice structures with their intrinsic electromechanical properties. The reconstructed conductivity distributions from ERT can reveal the severity and location of damaged struts without having to probe each strut. However, the low central sensitivity of ERT may result in image artifacts and inaccurate localization of damaged struts. To address this issue, this study introduces an absolute, high throughput, conductivity reconstruction algorithm for 3D ERT. The algorithm incorporates a strut-based normalized sensitivity map to compensate for lower interior sensitivity and suppresses reconstruction artifacts. Numerical simulations and experiments on fabricated representative cellular lattice structures were performed to verify the ability of ERT to quantitatively identify single and multiple damaged struts. The improved performance of this method compared with classical ERT was observed, based on greatly decreased imaging and reconstructed value errors.

36 MATERIALS SCIENCE↗

Suppressing Ordering in Equiatomic Fe-Co via Laser Powder Bed Fusion

Neutron and electron diffraction was employed to evaluate the effectiveness of thermal management strategies in suppressing the formation of the equilibrium-ordered B2 (CsCl) phase in equiatomic binary Fe-Co specimens fabricated by laser powder bed fusion additive manufacturing. Specimens with a tensile dogbone geometry were fabricated using various combinations of process parameters (laser power and raster speed) and thermal management strategies (no support struts, struts only in the top gauge section, and struts throughout the gauge section). Diffraction results demonstrate that the rapid solidification during PBF-L effectively minimized B2 formation, with laser power and effective scan velocity having no significant impact on the degree of ordering. Furthermore, the inclusion of support struts in the top grip region had no perceivable impact on ordering, whereas specimens with support struts in the gauge region exhibited no detectable ordering. Results are discussed in the context of thermal finite element analysis predictions.

Laser Material Processing↗