A High-Performance Superconducting Tunnel Junction (STJ) Soft X-ray Detector for Biological Science
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Small-area (1x1 sq micron) high-current-density NbN-MgO-NbN tunnel junctions with I-V characteristics suitable for high frequency mixers were fabricated. These junctions are integrated with superconducting microstrip lines designed to resonate out the large junction capacitance. The mixer gain and noise performance were studied near 205 GHz as a function of the inductance provided by the microstrip. This has yielded values of junction capacitance of 85 fF/sq microns and magnetic penetration depth of 3800 angstroms. Mixer noise as low as 133 K has been obtained for properly tuned junctions. This is the best noise performance ever reported for an NbN SIS mixer.
Small area (less than 1 sq micron), high-current-density NbN/MgO/NbN tunnel junctions with I-V characteristics suitable for high-frequency mixers have been fabricated. Mesa-geometry junctions with an area of about 1 sq micron and critical current density of 5-10 kA/sq cm are integrated with superconducting microstrip lines designed to resonate out the junction capacitance. A study was made of the mixer gain and noise performance near 205 GHz as a function of the inductance provided by the microstrip line. This has confirmed, at a high millimeter-wave frequency, values of junction capacitance of 85 fF/sq micron and recently measured values of a magnetic penetration depth of 380 nm. Mixer noise temperatures as low as 134 K at 1.5 K have been obtained for properly tuned junctions. A significant improvement in mixer performance on cooling from 4.2 K to 1.5 K was observed. Edge-geometry junctions with an area of 0.3 sq microns and critical current density of 18-25 kA/sq cm have also been fabricated. These junctions give a mixer noise temperature of 145 K at 4.2 K without the use of integrated tuning elements. These are the best results ever achieved for NbN-based SIS mixers.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The development and construction of an ultralow noise heterodyne receiver for millimeter wave astronomy is described along with its use for 115.3 GHz Co line observations. The receiver uses a Superconductor-Insulator-Superconductor (SIS) quasiparticle tunnel junction mixer to convert the millimeter wave signal to a microwave intermediate frequency. Experiments aimed at quantitative verification of J. R. Tucker's quantum mixer theory are studied, to see whether it could be used as the basis for the design of a practical receiver. The experimental results were in excellent agreement with the theory, assuming the three frequency approximation. Infinite available gain and negative output resistance were observed for the first time, nonclassical effects which are not seen in conventional diode mixers. Using Tucker's theory, an SIS receiver was then designed and constructed. At 115 GHz, the single sideband receiver noise temperature is 83K, the lowest ever reported in this frequency range. A CO survey toward Cygnus-X region, using this SIS receiver on the Columbia-GISS 4 ft. telescope, is also described.
The design, fabrication, and testing of a quasi-particle tunnel junction receiver for use at 345 GHz are discussed. The design employs small area Nb/Nb-oxide/PbInAu edge junctions in order to keep the device capacitance small and maintain a modest value for omega R(N)C. For optimum noise performance and beam properties the mixer is contained in a waveguide mounting structure. The best sensitivity was obtained at 312 GHz where a double sideband (DSB) noise temperature of 275 K was measured. Noise temperatures of 400 K (DSB) or better were obtained out to 350 GHz.
A heterodyne mixer with a micromachined horn antenna and a superconductor-insulator- superconductor (SIS) tunnel junction as mixing element is tested in the W-band (75-115 GHz) frequency range. Micromachined integrated horn antennas consist of a dipole antenna suspended on a thin Si(3)N(4) dielectric membrane inside a pyramidal cavity etched in silicon. The mixer performance is optimized by using a backing plane behind the dipole antenna to tune out the capacitance of the tunnel junction. The lowest receiver noise temperature of 30 +/- 3 K (without any correction) is measured at 106 GHz with a 3-dB bandwidth of 8 GHz. This sensitivity is comparable to the state-of-the-art waveguide and quasi-optical SIS receivers, showing the potential use of micromachined horn antennas in imaging arrays.
A heterodyne mixer with a micromachined horn antenna and a superconductor-insulator-superconductor (SIS) tunnel junction as mixing element is tested in the W-band (75-115 GHz) frequency range. Micromachined integrated horn antennas consist of a dipole antenna suspended on a thin Si3N4 dielectric membrane inside a pyramidal cavity etched in silicon. The mixer performance is optimized by using a backing plane behind the dipole antenna to tune out the capacitance of the tunnel junction. The lowest receiver noise temperature of 30 +/- 3 K (without any correction) is measured at 106 GHz with a 3-dB bandwidth of 8 GHz. This sensitivity is comparable to the state-of-the-art waveguide and quasi-optical SIS receivers, showing the potential use of micromachined horn antennas in imaging arrays.
We have developed a low-noise 850 GHz superconductor-insulator-superconductor (SIS) quasi-particle mixer with NbTiN thin-film microstrip tuning circuits and hybrid Nb/AlN/NbTiN tunnel junctions. The mixer uses a quasioptical configuration with a planar twin-slot antenna feeding a two-junction tuning circuit. At 798 GHz, we measured an uncorrected double-sideband receiver noise temperature of T(sub RX) = 260 K at 4.2 K bath temperature. This mixer outperforms current Nb SIS mixers by a factor of nearly 2 near 800 GHz. The high gap frequency and low loss at 800 GHz make NbTiN an attractive material with which to fabricate tuning circuits for SIS mixers. NbTiN mixers can potentially operate up to the gap frequency, 2(delta)/h is approximately 1.2THz.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment uses superconducting tunnel junction (STJ) sensors to search for physics beyond the standard model (BSM) with recoil spectroscopy of the 7 Be EC decay into 7 Li. A pulsed UV laser is used to calibrate the STJs throughout the experiment with ∼20 meV precision. Phase-III of the BeEST experiment revealed a systematic calibration discrepancy between STJs. We found these artifacts to be caused by resistive crosstalk and by intensity variations of the calibration laser. For phase-IV of the BeEST experiment, we have removed the crosstalk by designing the STJ array so that each pixel has its own ground wire. We now also use a more stable UV laser for calibration. The new STJ arrays were fabricated at STAR Cryoelectronics and tested at LLNL and FRIB. They have the same high energy resolution of ∼1-2~eV in the energy range of interest below 100~eV as before, and they no longer exhibit the earlier calibration artifacts. We discuss the design changes and the STJ array performance for the next phase of the BeEST experiment.
Superconducting quantum bits (qubits) rely on ultra-thin, amorphous oxide tunneling barriers that can have significant inhomogeneities and defects as grown. This can result in relatively large uncertainties and deleterious effects in the circuits, limiting the scalability. Finding a robust solution to the junction reproducibility problem has been a long-standing goal in the field. Here, we demonstrate a transformational technique for controllably tuning the electrical properties of aluminum-oxide tunnel junctions. This is accomplished using a low-voltage, alternating-bias applied individually to the tunnel junctions, with which resistance tuning by more than 70% can be achieved. The data indicates an improvement of coherence and reduction of two-level system defects. Transmission electron microscopy shows that the treated junctions are predominantly amorphous, albeit with a more uniform distribution of alumina coordination across the barrier. This technique is expected to be useful for other devices based on ionic amorphous materials.
The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment searches for evidence of heavy neutrino mass eigenstates in the nuclear electron capture decay of 7 Be by precisely measuring the recoil energy of the 7 Li daughter. In Phase III, the BeEST experiment has been scaled from a singl superconducting tunnel junction (STJ) sensor to a 36-pixel array to increase sensitivity and mitigate gamma-induced backgrounds. Phase III also uses a new continuous data acquisition system that greatly increases the flexibility for signal processing and data cleaning. Here, we have developed procedures for signal processing and spectral fitting that are sufficiently robust to be automated for large datasets. Furthermore, this article presents the optimized procedures before unblinding the majority of the Phase III dataset to search for physics beyond the standard model.
Over the last few years, considerable progress have been made in the development of techniques for fabricating high-quality superconducting circuits, and this success, together with major advances in the theoretical understanding of quantum detection and mixing at millimeter and submillimeter wavelengths, has made the development of CAD techniques for superconducting nonlinear circuits an important new enterprise. For example, arrays of quasioptical mixers are now being manufactured, where the antennas, matching networks, filters and superconducting tunnel junctions are all fabricated by depositing niobium and a variety of oxides on a single quartz substrate. There are no adjustable tuning elements on these integrated circuits, and therefore, one must be able to predict their electrical behavior precisely. This requirement, together with a general interest in the generic behavior of devices such as direct detectors and harmonic mixers, has lead us to develop a range of CAD tools for simulating the large-signal, small-signal, and noise behavior of superconducting tunnel junction circuits.
This paper will describe the fabrication of small aluminum tunnel junctions for applications in astronomy. Antenna-coupled superconducting tunnel junctions with integrated single-electron transistor readout have the potential for photon-counting sensitivity at sub-millimeter wavelengths. The junctions for the detector and single-electron transistor can be made with electron-beam lithography and a standard self-aligned double-angle deposition process. However, high yield and uniformity of the junctions is required for large-format detector arrays. This paper will describe how measurement and modification of the sensitivity ratio in the resist bilayer was used to greatly improve the reliability of forming devices with uniform, sub-micron size, low-leakage junctions.
The BeEST experiment is a precision laboratory search for physics beyond the standard model that measures the electron capture decay of 7 Be implanted into superconducting tunnel junction (STJ) detectors. For Phase-III of the experiment, we constructed a continuously sampling data acquisition system to extract pulse shape and timing information from 16 STJ pixels offline. Four additional pixels are read out with a fast list-mode digitizer, and one with a nuclear MCA already used in the earlier limit-setting phases of the experiment. Here, we present the performance of the data acquisition system and discuss the relative advantages of the different digitizers.