Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sustainable Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Tailoring biogenic straw insulation from additive manufacturing

In the pursuit of carbon-storing materials that could help accomplish high levels of building sustainability, wheat straw has emerged as a promising alternative to fossil fuel-based building materials. Straw is 100% biodegradable and abundant agricultural waste used in the construction 400 years ago, and it has been reported to have the lowest embodied carbon when measured against other typical insulating materials. Here, in this study, we report additive manufacturing of carbon-sequestration insulation panel materials by upcycling cellulose fibrils from wheat straw. Cellulose obtained from alkaline and 2,2,6,6-tetramethylpiperidine-1-oxyl radical-mediated oxidation shows thermal conductivity of 0.036 W m -1 K -1 , alongside elastic and flexural modulus of 900 MPa and 502 MPa, respectively. In addition, an in-situ hydrophobic treatment in the cellulose-based insulation panels is achieved with an average water contact angle of 133.7° Furthermore, the extrusion-based additive manufacturing of a 3D-printable ink obtained by mixing the cellulose and silica aerogel precursor is accomplished, with the printed material exhibiting structural integrity, thus showing great potential towards the development of state-of-the-art, sustainable materials for carbon-sequestration building applications.

36 MATERIALS SCIENCE↗

Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China

Indoor environmental quality (IEQ) is an essential element of sustainable building performance. To advance knowledge of indoor environmental quality in Chinese nonresidential buildings, this study conducted post-occupancy evaluation (POE) in varied use areas within schools, hospitals, offices, hotels and shopping malls through environmental measurements and occupant surveys in 10 buildings over four seasons in Chongqing, China. Measured thermal conditions were more frequently within comfort standards in winter than in summer according to the predicted mean vote – predicted percentage dissatisfied model; but the model did not reliably predict thermal satisfaction. There was insufficient illuminance in 28% of studied areas and high illuminance in shopping malls led to complaints about glare. Sound pressure exceeded the Chinese guideline in all buildings with shopping malls having significantly higher levels than other buildings. CO 2 was generally below the Chinese national guideline of 1000 ppm; the two percent of measurements that exceeded the guideline occurred in classrooms, hospital wards and underground supermarkets. Formaldehyde did not exceed the limit level of 0.1 mg/m3 in any space. Most of the buildings did not provide effective protection from outdoor fine particulate matter (PM2.5), and infiltration from outdoors was the main factor for exceeding health-based guidelines indoors. Shopping malls had lower IEQ satisfaction than offices, schools and hospitals. Sound was the factor with the lowest satisfaction level among the four principal environmental factors. Overall, this study demonstrates value of POE on identifying deficiencies in indoor environment and provides a reference for assessment of IEQ in nonresidential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comparative analysis of green building rating systems in China and the United States

Several studies have compared green building rating systems (GBRSs) in China and the United States, Nonetheless, few studies included in-depth analysis on specific rating tools with project specific data validating green building technologies and actual performance. This study conducted a comprehensive data-driven comparison of the GBRSs of China and the United States. The goal was to understand the current status and further improve China's GBRS and promote green building technologies. The study first conducted thorough comparisons of GBRSs in China and the U.S. by selecting a series of distinct rating tools. Then, it analyzed each tool's development objectives, contents, and rating score settings. Further, the comparison concludes the future development needs for China's GBRS. In addition to standard comparison, green building technologies applied in certified projects were also summarized. The results demonstrated that GBRSs in both China and the U.S. reflect well the technical paths to achieve green building sustainable development. By analyzing certified projects, it was also found that the incremental costs of green building technologies were controllable. Finally, based on the comparison and case analysis, the study provide a set of policy recommendations to further improve China's green building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Building Energy Modeling with Large Language Models: Exploration and Case Studies

The rapid progression in artificial intelligence has facilitated the emergence of large language models like ChatGPT, offering potential applications extending into specialized engineering modeling, especially physics-based building energy modeling. This paper investigates the innovative integration of large language models with building energy modeling software, focusing specifically on the fusion of ChatGPT with EnergyPlus. A literature review is first conducted to reveal a growing trend of incorporating large language models in engineering modeling, albeit limited research on their application in building energy modeling. We underscore the potential of large language models in addressing building energy modeling challenges and outline potential applications including simulation input generation, simulation output analysis and visualization, conducting error analysis, co-simulation, simulation knowledge extraction and training, and simulation optimization. Three case studies reveal the transformative potential of large language models in automating and optimizing building energy modeling tasks, underscoring the pivotal role of artificial intelligence in advancing sustainable building practices and energy efficiency. The case studies demonstrate that selecting the right large language model techniques is essential to enhance performance and reduce engineering efforts. The findings advocate a multidisciplinary approach in future artificial intelligence research, with implications extending beyond building energy modeling to other specialized engineering modeling.

building energy modeling↗

Key Accomplishments & Results: Sustainable Wastewater Infrastructure of the Future

This fact sheet summarizes the key accomplishments and results from DOE's Better Buildings Sustainable Wastewater Infrastructure of the Future (SWIFt) Accelerator. The Accelerator was a 3-year effort between DOE and state and local jurisdictions to promote energy data management practices in wastewater operations in an effort to increase energy efficiency in wastewater facilities around the country. Accelerator participants shared implementation plans, and DOE combined the results into a final toolkit.

wastewater, water resource recovery facilities, en↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

Multimodal sensor fusion framework for residential building occupancy detection

For several years now, smart building energy systems have been a research area of intensive activity. In light of the increasing need for sustainable buildings and energy systems, this trend motivates an increasing need for a solution to reduce carbon dioxide emissions and improve energy efficiency. This work proposes a high-performing and transferable occupancy detection framework that combines sensor data from different data modalities, including time series environmental data (temperature, humidity, and illuminance), image data, and acoustic energy data using ensemble method. To draw out the best prediction performance in each modality, the proposed framework was developed, including various models that were designed to learn the occupancy patterns reflected in the physical data streams. To tackle the time series environmental data, we designed two variants of an occupancy detection spatiotemporal pattern network (Occ-STPN) that performs both feature level and decision level fusion, respectively. We also propose a new metric; the fading memory mean square error (FMMSE), that provides a fair evaluation and penalization of delayed occupancy predictions. Multiple open-sourced datasets, including the Electricity Consumption and Occupancy and the University of California, Irvine's (UCI) building occupancy detection dataset, along with our own real data collected from six different houses, were used to validate the algorithms' performance. The experimental results presented herein break down the performance for each sensing modality, and a detailed analysis of the performance is also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilience with Renewables

This presentation is intended for the DOE Better Buildings Sustainable Corrections Infrastructure Partnership (SCIP) program webinar series. It will explain the INL Resilience Framework, discuss how to apply it for building managers, and give examples of the ways batteries can aid in resilience by walking through a case study conducted for Iowa Lakes Electric Cooperative.

17 WIND ENERGY↗

Building Life-Cycle Analysis with the GREET Building Module: Methodology, Data, and Case Studies

To holistically address building sustainability, Argonne National Laboratory has expanded its Greenhouse gases, Regulated Emissions, and Energy use in Technologies (GREET) life-cycle model with a new GREET Building Module. This report documents life-cycle analysis (LCA) methodology and foreground data that Argonne National Laboratory compiles and develops to address embodied greenhouse gas (GHG) emissions and energy impacts of a wide range of envelope and structural building materials for new construction and retrofits. The methodology and data form the backbone of the GREET Building Module. This research effort focuses on developing consistent LCA methodology that conforms to building LCA standards such as the EN 15978 to address embodied GHG emissions and energy impacts of building materials/technologies. We document detailed foreground data for selected building materials and building components that are common for building construction. To test the LCA methodology and the GREET Building Module, this report includes case studies of insulation materials and wall panels for residential building retrofit. We have developed a separate document as a User Guide for understanding and applying the GREET Building Module to conduct detailed, process-level LCA of embodied carbon and energy impacts of emerging building materials and technology solutions that of interest to the Building Technologies Office (BTO) of the US Department of Energy, researchers, and industry stakeholders.

42 ENGINEERING↗

Flame retardant biogenic building insulation materials from hemp fiber

Biogenic thermal insulation materials are in high demand because of its carbon-sequestration nature. However, high flammability, moisture condensation, and relatively high thermal conductivity of biogenic material are major concerns for sustainable building applications. In this study, we report the fire-retardant cellulose xerogel insulation nanocomposites derived from hemp fiber recycling and silica xerogel, in which the boric acid treatment improves its fire retardancy. The as-prepared materials show a low thermal conductivity of 31.3 mW/m K, high flexural modulus of 665 MPa, hydrophobicity with the water contact angle of 115°, and fire retardancy with 30% weight loss over a period of burning time 10 min. Overall, this work provides an effective method for the synthesis of fire-retardant biogenic thermal insulation materials and shows a promising way for next-generation bio-based insulation materials.

36 MATERIALS SCIENCE↗

Flame-retardant cellulose-aerogel composite from agriculture waste for building insulation

Bio-based thermal insulation materials are in high demand due to their availability, reproducibility, and carbon-sequestration nature. However, high flammability, moisture condensation, and high thermal conductivity of biogenic material are major concerns for sustainable building applications. In this study, we report the fire-retardant cellulose aerogel insulation nanocomposites derived from wheat straw and silica aerogel, in which sodium bicarbonate improves its fire retardancy. We combined blended straw fibers and hammermilled straw fibers to create a structural hierarchy composite. The blended straw, with its longer and thicker size, served as reinforcement, while the hammermilled straw fibers acted as filler. This hierarchical structure was further integrated with aerogel for applications in green buildings. The as-prepared materials show a low thermal conductivity of 24.1 mW/m.K, high flexural modulus of 736 MPa, hydrophobicity with a water contact angle of 110.42°, and excellent fire retardancy. Altogether, this work provides an effective method for the synthesis of fire-retardant biogenic thermal insulation materials and shows a promising way for next-generation bio-based insulation materials.

36 MATERIALS SCIENCE↗

Convincing Clients to Make Zero a Reality: Preprint

As buildings are the largest end-users of carbon-intensive energy in the United States, it is critical that design and construction professionals implement energy-efficient and sustainable building designs and systems. Building owners seeking building energy performance improvements, either with new construction or retrofit of existing facilities, usually need the expertise of design and construction professionals to guide them through the process. These "trusted advisers" make the design decisions that ultimately result in the energy performance of the building. Members of the design and construction community have identified that clients' perception of cost associated with such designs and building upgrades have posed the most significant barrier to increased adoption. If solved, this would enable design and construction firms to better engage as trusted advisors along the lines of energy and carbon reduction of the built environment. NREL has developed a resource that helps design and construction professionals and their clients match their projects with financial incentives. A newly developed cohort of design and construction professionals, as part of the U.S. Department of Energy's Better Buildings Initiative, has brought real-world project experiences to the development process, contributing meaningful insights that have been critical to evaluating the successes of and providing direction to this much needed financial guide.

Better Buildings↗

A deep learning-based Bayesian framework for high-resolution calibration of building energy models

Calibrating building energy models (BEMs), i.e., closing discrepancy between modeling and field measurements, is of significance to support its applications in building sustainability and resilience analysis. However, as being widely used in practice, current Bayesian calibration is mostly performed in low-resolution (annual or monthly), instead of high-resolution (hourly or sub-hourly), which is crucial to support emerging BEM applications, such as building-renewable energy integration (demand response) and smart control. This is attributable to the gaps in current Bayesian calibration process, including (1) difficulty in supporting reliable high-resolution calibration with over-parameterization and multi-solution issues, (2) inadequacy of meta-model to capture temporal building dynamics in high-resolution, and (3) excessive computational burdens of covariance matrix calculation in Bayesian inference. Therefore, to close these gaps, this research proposes a novel deep learning-based Bayesian calibration framework, involving pre-calibration mechanism, Long Short-Term Memory as surrogate models, and simplified covariance matrix calculation, to calibrate BEMs in high temporal resolution (i.e., hourly) with enhanced accuracy and computational efficiency. Finally, the case study demonstrates its effectiveness to match modeling outcomes with measurements and realize CV-RMSE of < 30 % and NMBE of < 6 % in hourly resolution, as well as a significant reduction of calibration time (by > 99 %, from > 600 h to ~ 1.5 h).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Global and regional perspectives on optimizing thermo-responsive dynamic windows for energy-efficient buildings

Architectural thermo-responsive dynamic windows offer an autonomous solution for solar heat regulation, thereby reducing building energy consumption. Previous work has emphasized the significance of thermo-responsive windows in hot climates due to their role in solar heat control and subsequent energy conservation; conversely, our study provides a different perspective. Through a global-scale analysis, we explore over 100 material samples and execute more than 2.8 million simulations across over two thousand global locations. World heatmap results, derived from well-trained artificial neural network models, reveal that thermo-responsive windows are especially useful in climates where buildings demand both heating and cooling energy, whereas thermo-responsive windows with optimal transition temperatures show no dynamic features in most of low-latitude tropical regions. Additionally, this study provides a practical guideline and an open-source mapping tool to optimize the intrinsic properties of thermo-responsive materials and evaluate their energy performance for sustainable buildings at various geographical scales.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Raising the Bar in High Performance Laboratory Design

Laboratory facilities are expensive to build and operate, they consume energy at high rates compared to other types of buildings, and modifications are frequently required to accommodate ever-changing research activities. PNNL sought ways to address these issues in the design and construction of a 14,700 sq. ft. new laboratory building. To improve adaptability to change a high roof structure was used that allows raising the ceiling when needed with minimal disruption to installed HVAC and electrical utilities. Also, HVAC equipment was located on a mezzanine above the central corridor rather than above ceilings. This eliminates the need for maintenance personnel to routinely access lab spaces, reducing disruption to research staff and improving maintenance access. To improve the reliability of operations while reducing energy consumption, heat pipe heat recovery with evaporative cooling, zoned heating/cooling coils, high-efficiency condensing boilers, district cooling, VAV fume hoods, DDC controls, energy use monitoring, and implementation of the US Department of Energy’s Guiding Principles for Federal Leadership in Sustainable Buildings were all used. The energy model developed during design projected energy use at 2,840 MBtu/yr, a 13.5% savings over ASHRAE Standard 90.1-2010. The first full year of operation resulted in actual energy use of 2,661 MBtu, a savings of 19% over Standard 90.1. As a result of the project design’s demonstrated success, these strategies will be incorporated into a significantly larger (125,000 sq ft), $65 million lab facility to be constructed on the PNNL campus in 2020.

Scott, Jeffery M.↗

Digital Twin Applications in the Water Sector: A Review

As cities develop and resource demands rise, the water sector faces crucial challenges to deliver reliable, sustainable, and efficient services. Digital Twins (DTs), virtual replicas of physical systems, offer a promising tool to transform how we manage water infrastructure. Originally developed in the aerospace industry, DTs are now gaining traction in the water sector, enabling real-time monitoring, simulation, and predictive control of water and wastewater treatment, collection and distribution networks, and water reclamation and reuse systems. While still emerging in the water sector, DTs have shown potential to enhance operational efficiency, reduce environmental impacts, and support smarter, more resilient water management. This review study provides a comprehensive overview of current DT applications in the water sector, highlighting successful case studies, technical challenges, and knowledge gaps. It also explores how DTs can help bridge the water–energy nexus by optimizing resources utilized across interconnected systems. By synthesizing recent advances and identifying future research directions, this paper illustrates how DTs can play a central role in building sustainable, adaptive, and digitally-enabled water infrastructure.

digital twin↗

Carbon-Sequestration Straw Cellulose-Aerogel Gradient Thermal Insulation Material

Green superinsulation materials are essential for net-zero sustainable building envelopes. Realizing such potential is indispensable for simultaneously achieving carbon-sequestration and superinsulation performance. Here, we report the synthesis of a water glass-based silica aerogel exhibiting a thermal conductivity of 17.2 mW/m·K and a high porosity of 92%. Here, we used carbon-sequestration wheat straw fiber to create a gradient cellulose-aerogel composite to improve mechanical stability. The as-prepared gradient composite exhibits a thermal conductivity of 27.1 mW/m·K and a flexural modulus of 824 MPa, while exhibiting superhydrophobicity (water contact angle of 135.4°) for the development of green building insulation materials.

36 MATERIALS SCIENCE↗