Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systems Performance Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform

For future human exploration missions, NASA needs a health monitoring system composed of hardware that is compact, fully interoperable with an integrated data management system, and requires minimal consumables. Such a system will be achieved through the integration of small, easy to use biomedical sensors that will have the ability to measure, store and transmit physiological parameters during operational and ambulatory activity. Since 2012, the Canadian Space Agency (CSA) has been active in funding the development of wearable biomonitoring sensors. The Astroskin is the first prototype and consists of a shirt-based garment and headband with embedded sensors, and associated software and technology that measure vital signs, sleep quality and activity level of the wearer. NASA and CSA have been collaborating since 2014 to test and validate this system in a lab environment at Ames Research Center and more recently in the Human Exploration Research Analog (HERA) located at Johnson Spaceflight Center. Specific objectives of the HERA study were: 1) to assess the performance of the Astroskin biosensor system for long-term health monitoring (24-hours) capabilities and during exercise as a measure of crew fitness; 2) to obtain crew feedback on comfort and usability of the Astroskin system; 3) to demonstrate performance of Bluetooth communication during real-time transmission and for verification of data in this environment; and 4) to obtain baseline data for further development of algorithms and tools that facilitate decision support for diagnosing and monitoring of a sick or injured crewmember. HERA Campaign 3 included four missions (each 30-days in duration) with four crewmembers assigned to each mission. A total of 9 men and 7 women participated in the Astroskin evaluation that included continuous physiological monitoring (24-hours) on mission days MD-11, MD1 (high workload), MD15 (low workload), MD19, MD29, and MD+7. Mission days 19 and 29 also included 30 minutes of sub-maximal exercise on a cycle ergometer. Following each 24-hour monitoring session crew physiological data were downloaded to laptops and each crewmember completed a 28 question survey on their experiences with the Astroskin hardware and software. This presentation will focus on lessons learned from the HERA missions. Specifically it will address Astroskin system performance in terms of data loss and data quality (no comparison to lab standard devices), wireless communication with the onboard mobile device, crew usability and comfort, and future development of a next generation biomonitoring system.

crew fitness↗

CCD camera system for cometary research

The objective is to upgrade the NASA/GSFC 36 inch telescope instrumentation, primarily with a new charge coupled device (CCD) camera system, to permit an effective monitoring program of cometary activity by means of narrowband imaging and spectroscopic techniques. Researchers have twice taken delivery of the CCD camera system from Princeton Scientific Instruments and twice returned it within six weeks for repair. During the times they had the camera system in the lab, they measured the instrumental performance of the TEK 512 x 512 CCD chip (e.g., readout noise, dark current, etc) and developed the complete operational software for the camera system plus several useful observing and data reduction routines for use at the telescope. The CCD camera system is controlled by an IBM-AT computer. The peripheral equipment and software to permit the efficient transfer of large amounts of data to the LASP's computers (VAXs) and subsequent timely reductions are also in place. The Io torus (S II) emission was monitored with a Fabry-Perot scanning spectrometer, in conjunction with the International Jupiter Watch. The CCD camera system will be coupled to a narrowband interference filter imager and a long-slit spectrograph to provide regular and well-calibrated spatial and spectral observations of comets.

Oliversen, R. J.↗

Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.

Mora, Maria F.↗

Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements

Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.

Whitmore, Stephen A.↗

Design and Modelling of a Microfluidic Electro-Lysis Device with Controlling Plates

Many Lab-on-Chip applications require sample pre-treatment systems. Using electric fields to perform cell-lysis in bio-MEMS systems has provided a powerful tool which can be integrated into Lab-on-a-Chip platforms. The major design considerations for electro-lysis devices include optimal geometry and placement of micro-electrodes, cell concentration, flow rates, optimal electric field (e.g. pulsed DC vs. AC), etc. To avoid electrolysis of the flowing solution at the exposed electrode surfaces, magnitudes and the applied voltages and duration of the DC pulse, or the AC frequency of the AC, have to be optimized for a given configuration. Using simulation tools for calculation of electric fields has proved very useful, for exploring alternative configurations and operating conditions for achieving electro cell-lysis. To alleviate the problem associated with low electric fields within the microfluidics channel and the high voltage demand on the contact electrode strips, two "control plates" are added to the microfluidics configuration. The principle of placing the two controlling plate-electrodes is based on the electric fields generated by a combined insulator/dielectric (gladwater) media. Surface charges are established at the insulator/dielectric interface. This paper discusses the effects of this interface charge on the modification of the electric field of the flowing liquid/cell solution.

Jenkins, A.↗

Studies of microwave scattering and canopy architecture for boreal forests

Our primary objectives during the last year have been to develop a helicopter-borne radar system for measuring microwave backscatter from vegetation and to use this system to study the characteristics of backscatter from the boreal forest. Our research is aimed at refining the current microwave models and using these improvements for more accurate interpretation of SAR data. SAR data are very useful for monitoring the boreal forest region because of the microwave signal's ability to penetrate clouds and to see at night. Meeting these objectives involves several stages of development. The first stage is the design and implementation of a frequency-modulated continuous-wave (FM-CW) radar system with the capability of measuring backscatter at three frequencies and four polarizations at each frequency. These requirements necessitate a twelve-channel radar system. Using three frequencies is advantageous because it allows us to look at different parts of the canopy. For instance, the lower frequency signal penetrates deeper into the canopy and allows us to see the ground while the high frequency signal is scattered more by the leaves and needles and typically does not penetrate to the floor of the forest. We designed the radar starting with the antenna system. We then developed the intermediate frequency (IF) and radio frequency (RF) sections of the radar. Also, the need to collect data from twelve channels during each flight line presented a complex data acquisition problem that we solved by using a high-speed data acquisition board. After construction, the radar was tested at the lab. We performed extensive testing of the IF and RF systems of the radar during this time. Once we were satisfied with the operation of the radar it was shipped to Canada for use in the second intensive field campaign (IFC-2) from July 16 - August 8, 1994. During IFC-2, we collected backscatter data over the experimental sites in the southern study area (SSA). Additionally, we used a ground-based step-frequency radar to measure the reflection coefficient of the forest floor at the old jack pine (OJP) and young jack pine (YJP) sites. The ground-based radar data have been processed and a frew examples are included in this report. we are currently processing the helicopter-borne radar data.

Lockhart, G. Lance↗

Quantitative assessment of human motion using video motion analysis

In the study of the dynamics and kinematics of the human body, a wide variety of technologies was developed. Photogrammetric techniques are well documented and are known to provide reliable positional data from recorded images. Often these techniques are used in conjunction with cinematography and videography for analysis of planar motion, and to a lesser degree three-dimensional motion. Cinematography has been the most widely used medium for movement analysis. Excessive operating costs and the lag time required for film development coupled with recent advances in video technology have allowed video based motion analysis systems to emerge as a cost effective method of collecting and analyzing human movement. The Anthropometric and Biomechanics Lab at Johnson Space Center utilizes the video based Ariel Performance Analysis System to develop data on shirt-sleeved and space-suited human performance in order to plan efficient on orbit intravehicular and extravehicular activities. The system is described.

Probe, John D.↗

Quantitative assessment of human motion using video motion analysis

In the study of the dynamics and kinematics of the human body a wide variety of technologies has been developed. Photogrammetric techniques are well documented and are known to provide reliable positional data from recorded images. Often these techniques are used in conjunction with cinematography and videography for analysis of planar motion, and to a lesser degree three-dimensional motion. Cinematography has been the most widely used medium for movement analysis. Excessive operating costs and the lag time required for film development, coupled with recent advances in video technology, have allowed video based motion analysis systems to emerge as a cost effective method of collecting and analyzing human movement. The Anthropometric and Biomechanics Lab at Johnson Space Center utilizes the video based Ariel Performance Analysis System (APAS) to develop data on shirtsleeved and space-suited human performance in order to plan efficient on-orbit intravehicular and extravehicular activities. APAS is a fully integrated system of hardware and software for biomechanics and the analysis of human performance and generalized motion measurement. Major components of the complete system include the video system, the AT compatible computer, and the proprietary software.

Probe, John D.↗

Facility for the evaluation of space communications and related systems

NASA Lewis Research Center's Communications Projects Branch has developed a facility for the evaluation of space communications systems and related types of systems, called the Advanced Space Communications (ASC) Laboratory. The ASC Lab includes instrumentation, testbed hardware, and experiment control and monitor software for the evaluation of components, subsystems, systems, and networks. The ASC lab has capabilities to perform radiofrequency (RF), microwave, and millimeter-wave characterizations as well as measurements using low, medium, or high data rate digital signals. In addition to laboratory measurements, the ASC Lab also includes integrated satellite ground terminals allowing experimentation and measurements accessing operational satellites through real space links.

Kerczewski, Robert J.↗

Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling

BACKGROUND As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab in NASA Johnson Space Center's (JSC) Software, Robotics, and Simulation Division, aims to address this challenge through innovative approaches. This study presents the development and evaluation of an NGED system, focusing on its adaptability to various mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). Central to this project is the application of biomechanical modeling to optimize exercise efficacy and safety in microgravity and partial gravity environments. The project is a collaborative effort with the Human Health and Performance group at Johnson Space Center, ensuring a comprehensive approach to astronaut well-being that integrates biomechanical principles with practical exercise solutions. The NGED represents the next generation of exercise capabilities for missions in space, on the Moon and Mars, with a specific focus on applications such as the LPR. METHODS AND RESULTS Data collection for NGED development was conducted with two motor-driven Beyond Power Voltra I [1] systems and a custom test structure to allow placement of the cable-based devices on the ground, at shoulder height, and overhead. The collection was performed in JSC’s Prototype Immersive Technology (PIT) Lab, utilizing an OptiTrack motion capture system and AMTI force platform, to enable detailed biomechanical analysis via OpenSim [2,3]. Motion capture data were collected for three subjects representing different body types and statures. The marker set used was an enhanced version of the full-body Plug-in Gait marker set [4], with additional markers strategically placed for the primary objective of informing exercise volume requirements. Subjects performed a series of 17 exercises, carefully selected to engage various muscle groups, including novel spaceflight exercises such as skiing (ergometer style), lateral pulldowns, wood chops, triceps extensions, and flies, with load variations ranging from 10 to 90 pounds to maintain kinematic form. This comprehensive approach allowed for a thorough evaluation of the NGED's performance across a wide range of motions and loads. The biomechanical modeling and analysis were conducted using a modified OpenSim Full Body Rajagopal Model [4,5] and also scaled to the maximum and minimum anthropometry provided in NASA-STD-3001 [6]. Volumetric convex hulls were generated based on model marker trajectories and aggregated into geometric assemblies. These can be placed in models of vehicle designs to assess fit to protect for exercise as well as to adapt NGED exercise to fit available space. Preliminary findings from the collection indicate that the NGED prototype demonstrates significant adaptability across varying user anthropometrics and exercise types. The device showed consistent performance in load-bearing exercises, with subjects able to perform exercises effectively while maintaining proper biomechanical form. CONCLUSION NGED represents a forward-looking advancement in exercise capabilities for future space missions. In the future, this system can be used to capture valuable metrics (e.g., isometric mid-thigh pull for force output measurements, assessments of postural muscle strength, overall isometric strength). Its versatility in accommodating various exercises and user physiques, coupled with the ability to provide targeted biomechanical loading, makes it a promising approach for maintaining astronaut health during long-duration missions to the Moon and Mars. Future work will focus on refining the NGED based on initial biomechanical findings, leveraging the detailed insights provided by motion capture and analysis techniques. Particular emphasis will be placed on optimizing its use within the confined spaces of a LPR and other space habitats. This work contributes significantly to NASA's goals of supporting human health and performance in deep space exploration, paving the way for sustainable long-term presence beyond Low Earth Orbit through advanced, biomechanically-informed exercise solutions.

C Wang↗

Design, Instrumentation, and Data Analysis for the SLS Core Stage Green Run Test Series

The Space Launch System (SLS) Core Stage (CS) Thrust Vector Control (TVC) system is comprised of eight mechanical feedback Shuttle heritage Type III TVC actuators and four RS-25 engines, each attached to a Shuttle heritage gimbal block/bearing. The actuators are powered by a Shuttle-derived hydraulic Core Auxiliary Power Unit (CAPU), and integrated with an all-new Core Stage thrust structure. The actuators are interfaced to the SLS Vehicle Management (VM) software via an all-new TVC Actuator Control (TAC) avionics subsystem. Despite the significant test and flight experience of the Shuttle hardware, the SLS Green Run ambient and hot fire test activities revealed a number of new findings associated with the dynamic response of the TVC integrated system. Test responses suggested that the TVC system did not meet its performance specifications and its step and frequency responses exhibited unexpected departures from prior lab tests and modeled behavior. This paper is the fifth installment in a seven-paper series surveying the design, engineering, test validation, and flight performance of the Core Stage Thrust Vector Control system. In this paper, the design of the TVC analyses conducted during the Core Stage Green Run test series are discussed in detail. Throughout the course of the test activities, the SLS flight control team worked diligently with the Core Stage contractor to revise test command profiles and ensure sufficient instrumentation was available to collect data. Post-test analysis combined the Green Run modal, ambient, and hot fire test data, MSFC 2- axis Core Stage TVC Inertial Load Simulator (ILS) data, Hardware-In-the-Loop (HWIL) Systems Integration Lab (SIL) results, and actuator Acceptance Testing Procedure (ATP) responses. These data were used to characterize the response, validate critical math models of the TVC subsystem, and isolate the probable cause of the unexpected responses. Through comprehensive analysis of the available test data sources, the integrated team identified the dominant contributors to the observed response and developed test-correlated rationale for vehicle flight control system performance, ultimately leading to a confident posture for the Artemis I mission.

John H. Wall↗

Comparison of UNL laser imaging and sizing system and a phase Doppler system for analyzing sprays from a NASA nozzle

Research was conducted on characteristics of aerosol sprays using a P/DPA and a laser imaging/video processing system on a NASA MOD-1 air assist nozzle being evaluated for use in aircraft icing research. Benchmark tests were performed on monodispersed particles and on the NASA MOD-1 nozzle under identical lab operating conditions. The laser imaging/video processing system and the P/DPA showed agreement on a calibration tests in monodispersed aerosol sprays of + or - 2.6 micron with a standard deviation of + or - 2.6 micron. Benchmark tests were performed on the NASA MOD-1 nozzle on the centerline and radially at 0.5 inch increments to the outer edge of the spray plume at a distance 2 ft downstream from the exit nozzle. Comparative results at two operation conditions of the nozzle are presented for the two instruments. For the 1st case studied, the deviation in arithmetic mean diameters determined by the two instruments was in a range of 0.1 to 2.8 micron, and the deviation in Sauter mean diameters varied from 0 to 2.2 micron. Severe operating conditions in the 2nd case resulted in the arithmetic mean diameter deviating from 1.4 to 7.1 micron and the deviation in the Sauter mean diameters ranging from 0.4 to 6.7 micron.

Alexander, Dennis R.↗

Multilayer Piezoelectric Stack Actuator Characterization

Future NASA missions are increasingly seeking to use actuators for precision positioning to accuracies of the order of fractions of a nanometer. For this purpose, multilayer piezoelectric stacks are being considered as actuators for driving these precision mechanisms. In this study, sets of commercial PZT stacks were tested in various AC and DC conditions at both nominal and extreme temperatures and voltages. AC signal testing included impedance, capacitance and dielectric loss factor of each actuator as a function of the small-signal driving sinusoidal frequency, and the ambient temperature. DC signal testing includes leakage current and displacement as a function of the applied DC voltage. The applied DC voltage was increased to over eight times the manufacturers' specifications to investigate the correlation between leakage current and breakdown voltage. Resonance characterization as a function of temperature was done over a temperature range of -180C to +200C which generally exceeded the manufacturers' specifications. In order to study the lifetime performance of these stacks, five actuators from one manufacturer were driven by a 60volt, 2 kHz sine-wave for ten billion cycles. The tests were performed using a Lab-View controlled automated data acquisition system that monitored the waveform of the stack electrical current and voltage. The measurements included the displacement, impedance, capacitance and leakage current and the analysis of the experimental results will be presented.

active mirrors↗

In-circuit fault injector user's guide

A fault injector system, called an in-circuit injector, was designed and developed to facilitate fault injection experiments performed at NASA-Langley's Avionics Integration Research Lab (AIRLAB). The in-circuit fault injector (ICFI) allows fault injections to be performed on electronic systems without special test features, e.g., sockets. The system supports stuck-at-zero, stuck-at-one, and transient fault models. The ICFI system is interfaced to a VAX-11/750 minicomputer. An interface program has been developed in the VAX. The computer code required to access the interface program is presented. Also presented is the connection procedure to be followed to connect the ICFI system to a circuit under test and the ICFI front panel controls which allow manual control of fault injections.

Padilla, Peter A.↗

Simulation of MC-1 Engine on Real-Time Station

The MC-1 rocket engine is a new, 60,000-pound-thrust engine designed to boost small spacecraft carrying payloads weighing up to 500 pounds. The engine was designed in-house at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, and built by SUMMA Technology, Inc. A vital part of the success of the engine development was the verification of the Propulsion System Controller (PSC) used to control the MC-1 engine during development testing at test facilities in Mississippi and California. The MC-1 engine simulation software was developed on the Applied Dynamics, Inc.'s Real-Time Station (RTS) computer system (ESL) to verify the PSC's hardware and software performance in the Marshall Avionics System Testbed's (MAST) Engine Simulation Lab at the MSFC. The engine model includes the simulation of pressure transducers, thermocouple sensors and valve-positions.

Ly, William↗

Noninvasive Sensor for Measuring Muscle Metabolism During Exercise

The measurement of oxygen uptake (VO2) and lactate threshold (LT) are utilized to assess changes in aerobic capacity and the efficacy of exercise countermeasures in astronauts. During extravehicular activity (EVA), real-time knowledge of VO2 and relative work intensity can be used to monitor crew activity levels and organize tasks to reduce the cumulative effects of fatigue. Currently VO2 and LT are determined with complicated measurement techniques that require sampling of expired ventilatory gases, which may not be accurate in enclosed, oxygen-rich environments such as the EVA suit. The UMMS team has developed a novel near infrared spectroscopic (NIRS) system which noninvasively, simultaneously and continuously measures muscle oxygen tension, oxygen saturation, pH (pHm), and hematocrit from a small sensor placed on the leg. This system is unique in that it allows accurate, absolute measurement of these parameters in the thigh muscle by correcting spectra for the interference from skin pigment and fat. These parameters can be used to estimate VO2 and LT. A preliminary evaluation of the system s capabilities was performed in the NASA JSC Exercise Physiology Lab.

Soller, B. R.↗

Advanced Modeling of Control-Structure Interaction in Thrust Vector Control Systems

The Space Launch System (SLS) Core Stage (CS) Thrust Vector Control (TVC) system is comprised of 8 mechanical feedback Shuttle heritage Type III TVC actuators and four RS-25 engines, each attached to a Shuttle heritage gimbal block/bearing. Two actuators are used to move each engine in two planes perpendicular to one another (i.e., pitch and yaw). The TVC system design leverages hardware from the Space Shuttle program as well as new hardware designed specifically for the Core Stage. During the development of the SLS TVC system, a family of advanced dynamics models were developed to extend and compliment the simplified quasi-linear “simplex” model historically used for flight control design and stability analysis. The importance of these advanced models became increasingly evident after ambient and hot fire testing of the Core Stage, which revealed a number of findings associated with the dynamic response of the TVC integrated system. Test responses suggested that the TVC did not meet its performance specifications and its step and frequency responses exhibited unexpected departures from prior lab tests and modeled behavior. One driving factor for these results was a higher-than-expected degree of coupling between the TVC system, the engine dynamics, and the Core Stage structure. This paper is the third installment in a seven-paper series surveying the design, engineering, test validation, and flight performance of the Core Stage Thrust Vector Control system. In this paper, a new method of modeling rocket vehicle thrust vectoring servoelastic dynamics is presented. In this approach, the load dynamics are replaced by a detailed finite element model containing both the rigid body and elastic modes. A partitioning technique is used to compute the effective compliance from the modal data and obtain accurate simulation results using a reduced number of generalized coordinates. Coupled backup structure and nozzle attach compliance effects on multiple engines are captured in higher fidelity than with a spring approximation, eliciting novel effects due to the complex load paths involved in the Core Stage structure. Validation of the model is demonstrated using a variety of structural/modal, laboratory, and full-scale hot fire test data.

Launch Vehicles↗

Advanced Modeling of Control-Structure Interaction in Thrust Vector Control Systems

The Space Launch System (SLS) Core Stage (CS) Thrust Vector Control (TVC) system is comprised of 8 mechanical feedback Shuttle heritage Type III TVC actuators and four RS-25 engines, each attached to a Shuttle heritage gimbal block/bearing. Two actuators are used to move each engine in two planes perpendicular to one another (i.e., pitch and yaw). The TVC system design leverages hardware from the Space Shuttle program as well as new hardware designed specifically for the Core Stage. During the development of the SLS TVC system, a family of advanced dynamics models were developed to extend and compliment the simplified quasi-linear “simplex” model historically used for flight control design and stability analysis. The importance of these advanced models became increasingly evident after ambient and hot fire testing of the Core Stage, which revealed a number of findings associated with the dynamic response of the TVC integrated system. Test responses suggested that the TVC did not meet its performance specifications and its step and frequency responses exhibited unexpected departures from prior lab tests and modeled behavior. One driving factor for these results was a higher-than-expected degree of coupling between the TVC system, the engine dynamics, and the Core Stage structure. This paper is the third installment in a seven-paper series surveying the design, engineering, test validation, and flight performance of the Core Stage Thrust Vector Control system. In this paper, a new method of modeling rocket vehicle thrust vectoring servoelastic dynamics is presented. In this approach, the load dynamics are replaced by a detailed finite element model containing both the rigid body and elastic modes. A partitioning technique is used to compute the effective compliance from the modal data and obtain accurate simulation results using a reduced number of generalized coordinates. Coupled backup structure and nozzle attach compliance effects on multiple engines are captured in higher fidelity than with a spring approximation, eliciting novel effects due to the complex load paths involved in the Core Stage structure. Validation of the model is demonstrated using a variety of structural/modal, laboratory, and full-scale hot fire test data.

Launch Vehicles↗