Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Teeing Off With an Entirely New Material

Liquidmetal(R) alloy is part of an entirely new class of vitrified metals, and is also known as metallic glass, or Vitreloy(R). A vitrified metal is a frozen liquid that fails to crystallize during solidification, unlike common metals such as titanium, steel, and aluminum. The technology takes the non-crystalline structure of glass and combines it with the properties of metal, a combination not found in nature, allowing for a product that offers the strength of a metal with the elasticity of a polymer. This unique technology is more than twice as strong as titanium and has a higher elastic limit. Liquidmetal(R) Golf presents this space-age development in a complete line golf clubs. Clubs made with this technology have a lower vibration response along with a softer, more solid feel. Because less energy is absorbed by the club's head upon impact, more energy is transferred directly to the ball. Vitreloy has potential commercial uses in sporting equipment: tennis rackets, bicycle frames, and baseball bats. The material may find applications in the medical industry for the manufacturing of surgical instruments and prosthetics. The Liquidmetal alloy is projected to replace many high performance materials, such as titanium, in the industries of aerospace, defense, military, automotives, medical instrumentation, and sporting goods

Source record↗

CROWBAR: Natively Fuzzing Trusted Applications Using ARM CoreSight

Abstract Trusted execution environments (TEE) are deployed on many platforms to provide both confidentiality and integrity, and their extensive use offers a secure environment for privacy-sensitive operations. Despite TEE prevalence in the smartphone and tablet market, vulnerability research into TEE security is relatively rare. This is, in part, due to the strong isolation guarantees provided by its implementation. In this paper, we propose a hardware assisted fuzzing framework, CROWBAR, that bypasses TEE isolation to natively evaluate trusted applications (TAs) on mobile devices by leveraging ARM CoreSight components. CROWBAR performs feedback-driven fuzzing on commercial, closed source TAs while running in a TEE protected environment. We implement CROWBAR on 2 prototype commercial-off-the-shelf (COTS) smartphones and one development board, finding 3 unique crashes in 5 closed source TAs that are previously unreported in the TrustZone fuzzing literature.

Shan, Haoqi↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.

Barile, R. G.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.

Barile, R. G.↗

Comparison of ground-based and space flight energy expenditure and water turnover in middle-aged healthy male US astronauts

Energy requirements during space flight are poorly defined because they depend on metabolic-balance studies, food disappearance, and dietary records. Water turnover has been estimated by balance methods only. The purpose of this study was to determine energy requirements and water turnover for short-term space flights (8-14 d). Subjects were 13 male astronauts aged 36-51 y with normal body mass indexes (BMIs). Total energy expenditure (TEE) was determined during both a ground-based period and space flight and compared with the World Health Organization (WHO) calculations of energy requirements and dietary intake. TEE was not different for the ground-based and the space-flight periods (12.40 +/- 2.83 and 11.70 +/- 1.89 MJ/d, respectively), and the WHO calculation using the moderate activity correction was a good predictor of TEE during space flight. During the ground-based period, energy intake and TEE did not differ, but during space flight energy intake was significantly lower than TEE; body weight was also less at landing than before flight. Water turnover was lower during space flight than during the ground-based period (2.7 +/- 0.6 compared with 3.8 +/- 0.5 L/d), probably because of lower fluid intakes and perspiration loss during flight. This study confirmed that the WHO calculation can be used for male crew members' energy requirements during short space flights.

STS Shuttle Project↗

The Incidence of Patent Foramen Ovale in 1,000 Consecutive Patients: A Contrast Transesophageal Echocardiography Study

Study objective: Patent foramen ovale (PFO) is present in 10 to 35% of people and has been reported to be an important risk factor for cardioembolic cerebrovascular accidents (CVAs) and transient ischemic attacks (TIAS), especially in younger patients. While contrast transthoracic echocardiography has been used to detect PFO, contrast transesophageal echocardiography (TEE) has a greater sensitivity. Prior studies reported the incidence of PFO in patients presenting with a CVA or TIA. Design: To determine the incidence of PFO in a more general population, we reviewed 1,000 consecutive TEES performed with contrast and color Doppler for the presence of PFO and other cardioembolic risk factors, including atrial septal aneurysm (ASA), aortic plaque, atrial fibrillation (AFib), and atrial thrombi. While imaging with monoplane or biplane TEE, multiple injections of agitated saline solution were injected during cough or Valsalva maneuver to detect flow through a PFO. Patients: There were 482 male and 518 female patients with mean age of 60 + 17 years (range 11 to 93 years). Results: Patent foramen ovale was found in 9.2% of all patients and, though seen in all age groups divided by decade, the incidence in patients aged 40 to 49 years was greater than those aged 70 to 79 years (12.96% vs 6.15%',, p=0.03). Contrast TEE had a much higher detection rate than color Doppler alone. Importantly, there was no greater incidence of PFO in patients with CVA vs thos~ without CVA, or in male vs female patients. Also, there was a very strong correlation between the presence of ASA and PFO (p<.001). Conclusion: Thus, PFO detected by TEE, frequently seen with ASA, is seen in all age groups and does not in itself present a risk factor for CVA. The association of PFO with peripheral thrombosis and CVA needs further study.

Fisher, Daniel C.↗

Efficacy of anticoagulation in resolving left atrial and left atrial appendage thrombi: A transesophageal echocardiographic study

BACKGROUND: Transesophageal echocardiography (TEE) is the gold standard for evaluation of the left atrium and the left atrial appendage (LAA) for the presence of thrombi. Anticoagulation is conventionally used for patients with atrial fibrillation to prevent embolization of atrial thrombi. The mechanism of benefit and effectiveness of thrombi resolution with anticoagulation is not well defined. METHODS AND RESULTS: We used a TEE database of 9058 consecutive studies performed between January 1996 and November 1998 to identify all patients with thrombi reported in the left atrium and/or LAA. One hundred seventy-four patients with thrombi in the left atrial cavity (LAC) and LAA were identified (1.9% of transesophageal studies performed). The incidence of LAA thrombi was 6.6 times higher than LAC thrombi (151 vs 23, respectively). Almost all LAC thrombi were visualized on transthoracic echocardiography (90.5%). Mitral valve pathology was associated with LAC location of thrombi (P <.0001), whereas atrial fibrillation or flutter was present in most patients with LAA location of thrombi. Anticoagulation of 47 +/- 18 days was associated with thrombus resolution in 80.1% of the patients on follow-up TEE. Further anticoagulation resulted in limited additional benefit. CONCLUSIONS: LAC thrombi are rare and are usually associated with mitral valve pathology. Transthoracic echocardiography is effective in identifying these thrombi. LAA thrombi occur predominantly in patients with atrial fibrillation or flutter. Short-term anticoagulation achieves a high rate of resolution of LAA and LAC thrombi but does not obviate the need for follow-up TEE.

NASA Discipline Cardiopulmonary↗

Transesophageal Echocardiography and Contrast-TCD in the Detection of a Patent Foramen Ovale: Experience with 111 Patients

Patent foramen ovale (PFO) is increasingly recognized in association with cryptogenic stroke. Using transesophageal echocardiography (TEE) and transcranial Doppler sonography with ultrasonic contrast medium contrast-(TCD), we evaluated the frequency of a PFO as the fundamental condition of paradoxical embolism in 111 patients after cerebral ischemia. There was a right-left shunt in 50 patients (45%) with TEE. In 31 of 40 patients with stroke of unknown etiology, a PFO was the only detectable finding associated with cerebral ischemia. Using TEE as he "gold standard," the sensitivity of contrast-TCD was 91.3%, specificity 93.8%, and the overall accuracy 92.8%. contrast-TCD failed to detect a right-left shunt in four patients, but there were four other patients with negative TEE and positive contrast-TCD. We conclude that contrast-TCD is a highly sensitive method for detecting a right-left shunt. Its advantages are low cost, its ability to detect single contrast-medium embolism, and control of the Valsalva maneuver by observing the decrease of cerebral blood flow. Evidence of PFO in cryptogenic stroke should prompt a search for a subclinical venous thrombosis as the embolic source.

Klotzsch, Christof↗

Enabling Design Space Exploration for RISC-V Secure Compute Environments

Cycle-level architectural simulation of Trusted Execution Environments (TEEs) can enable extensive design space exploration of these secure architectures. Existing architectural simulators which support TEEs are either based on hardware-level implementations or abstract analytic models. In this paper, we describe the implementation of the gem5 models necessary to run and evaluate the RISC- V-based open source TEE, Keystone, and we discuss how this simulation environment opens new avenues for designing and studying these trusted environments. We show that the Keystone simulations on gem5 exhibit similar performance as the previous hardware evaluations of Keystone. We also describe three simple example use cases (understanding the reason of trusted execution slowdown, performance of memory encryption, and micro-architecture impact on trusted execution performance) to demonstrate how the ability to simulate TEEs can provide useful information about their behavior in the existing form and also with enhanced designs.

97 MATHEMATICS AND COMPUTING↗

Fractional chiral hinge insulator

We propose and study a wave function describing an interacting three-dimensional fractional chiral hinge insulator (FCHI) constructed by Gutzwiller projection of two noninteracting second-order topological insulators with chiral hinge modes at half filling. We use large-scale variational Monte Carlo computations to characterize the model states via the entanglement entropy and charge-spin fluctuations. We show that the FCHI possesses fractional chiral hinge modes characterized by a central charge c = 1 and Luttinger parameter K = 1/2, like the edge modes of a Laughlin 1/2 state. The bulk and surface topology is characterized by the topological entanglement entropy (TEE) correction to the area law. While our computations indicate a vanishing bulk TEE, we show that the gapped surfaces host an unconventional two-dimensional topological phase. In a clear departure from the physics of a Laughlin 1/2 state, we find a TEE per surface compatible with (ln √2 )/2, half that of a Laughlin 1/2 state. This value cannot be obtained from topological quantum field theory for purely two-dimensional systems. For the sake of completeness, we also investigate the topological degeneracy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of coated columbium alloy heat shields for space shuttle thermal protection system application. Volume 2, phase 2: Subsize heat shield and small size TPS evaluation

Initially a trade study was conducted of seven heat shield configurations. These were evaluated for structural reliability, fabricability, weight, inspectability, and refurbishability. Two concepts, a tee-stiffened and an open corrugation, were selected as offering the most potential for system success. Fourteen subsize heat shields of a full scale section were fabricated from C-129Y and Cb-752 and silicide coated with R-512E. These subsize panels were subjected to a simulated flight profile representing temperature, local surface pressures, and applied pressure differential loads. All corrugated panels of both alloys sustained 100 cycles without structural or coating failure. All Cb-752/R-512E panels performed well with one panel being successfully repaired after 66 cycles and completing 100 cycles. As a result of this evaluating the Cb-752/R-512E system was selected for hardware application during the subsequent phases. In addition, the tee-stiffened configuration was selected for further development and application in Phase III. This selection was based on an overall assessment of relative weight, cost, and structural performance of the tee-stiffened and open corrugation TPS.

Black, W. E.↗

Custom Unit Pump Design and Testing for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the pre-flight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion , and restart capability under both ambient and vacuum conditions. The pump operated between 40 and 240 lbm/hr flowrate, 35 to 100 F pump temperature range, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test. The test results contained a number of anomalies, specifically power increases and a few flow stoppages, that prompted TEES and Honeywell to disassemble and inspect the pump. Inspection indicated contamination in the pump and fit issues may have played roles in the observed anomalies. Testing following reassembly indicated that the performance of the pump 1) matched both the predicted performance values, 2) the performance values measured prior to disassembly, and 3) was free of the anomalies noted in the pre-disassembly testing.

Schuller, Michael↗

Combining Information on Multiple Detection Techniques to Estimate the Effect of Patent Foramen Ovale on Susceptibility to Decompression Illness

The assembly and the maintenance of the International Space Station is expected to require hundreds of extravehicular excursions (EVA's) in the next 10 years. During an EVA, in order to allow movement and bending of limbs, spacesuit pressures are reduced to about 4.3 psi. as compared with about 14.7 psi. for normal atmospheric pressure at sea level. However, the exposure of astronauts to reduced pressures in spacesuits, is conducive to fonnation and growth of gas bubbles within venous blood or tissues, which could cause decompression illness (DCI), a pathology best known to occur among deep-sea divers when they return to the surface. To reduce the risk of DCI, astronauts adjust to the reduced pressure in stages for a prolonged time known as a "pre-breathe" period prior to their extravehicular activity. Despite the use of pre-breathe protocols, an increased risk of DCI can arise for about 25% of humans who have a small hole, known as a patent foramen ovale (PFO), between two chambers of the heart. The atrial septum's fossa oval is, an embryological remnant of a flap between the septae primum and secundum allows fetal right atrial blood to pass into the left atrium, and usually closes after birth (Hagen, et al,. 1984). If fusion does not occur, a valve-like opening, the foramen ovale persists between the two atria. It has been suggested that astronauts with PFO's might be at greater risk of stroke or other serious neurological DCI because bubbles from a venous site may traverse a PFO, travel to the aorta and then enter the cerebral circulatory system causing a stroke (Figure 1). Astronauts are not now screened for PFO's, however consideration is being given to doing so. Here, we study three main methods abbreviated here as "ITE", "TCD" and "TEE", for detecting PFO's in living subjects. All involve the introduction of bubbles into a vein, immediately after which a sensory probe attempts to detect the bubbles in systemic circulation. Presence of the injected bubbles in the systemic circulation is indicative of a PFO. More detailed descriptions are given after the explanation of PFO's under Figure I. Even if a true PFO affects the risk of DCI, there remains a question of how effective screening would be if the detection method has errors of omission and/or commission. Of the three methods studied here, TEE is the "gold standard", matching autopsy results with near-perfect sensitivity and specificity (Schneider, et al. , 1996). However TEE is also the most difficult method to implement, requiring an internal esophagal probe, and is therefore not widely used. Currently, the easiest to use and most common PFO detection method is TTE, which uses an external chest probe. This method has a specificity of near 100%, but suffers from a low sensitivity rate (about 30%). More recently, TCD has been developed, which uses ultrasound probes to detect the presence of bubbles in cerebral arteries. Studies indicate that TCD is quite effective, having a sensitivity of about 91% and a specificity of about 93% (Droste, et al., 1999) when applied correctly, however implementation is difficult and requires considerable training.

Feiveson, Alan H.↗

PROGRESS ON MAGNETRON R&DS FOR INDUSTRIAL PARTICLE ACCELERATORS

The magnetron as an efficient RF source for a compact industrial SRF accelerator has been developed. The per-formance of injection phase lock on two independent magnetron transmitters operated at 915MHz, in CW mode with maximum power of 75kW each has been demon-strated to satisfy this application. This industrial type magnetron has AC transformer and the SCR rectifier on the DC anode power supply. Output power spectrum with phase locking can achieve noise reduction of -21.2 dBc at the 1st 60 Hz, -28.0 dBc at 1st 180 Hz with only -22.6 dBc injection power. Further control studies for 2×75 kW, 915 MHz power combing by WR975 magic-tee at Jefferson Lab (JLab) and for 4×1.2 kW, 2.45 GHz power combing by WR340 magic-tee at General Atomics (GA).

Rimmer, R.↗

Performance Analysis of Scientific Computing Workloads on Trusted Execution Environments

Scientific computing sometimes involves computation on sensitive data. Depending on the data and the execution environment, the HPC (high-performance computing) user or data provider may require confidentiality and/or integrity guarantees. To study the applicability of hardware-based trusted execution environments (TEEs) to enable secure scientific computing, we deeply analyze the performance impact of AMD SEV and Intel SGX for diverse HPC benchmarks including traditional scientific computing, machine learning, graph analytics, and emerging scientific computing workloads. We observe three main findings: 1) SEV requires careful memory placement on large scale NUMA machines (1x -3.4x slowdown without and 1x -1.15x slowdown with NUMA aware placement), 2) virtualization - a prerequisite for SEV - results in performance degradation for workloads with irregular memory accesses and large working sets (1x -4x slowdown compared to native execution for graph applications) and 3) SGX is inappropriate for HPC given its limited secure memory size and inflexible programming model (1.2x -126x slowdown over unsecure execution). Finally, we discuss forthcoming new TEE designs and their potential impact on scientific computing.

97 MATHEMATICS AND COMPUTING↗

Resonance-tube ignition of aluminum

An experimental program was carried out to determine whether spontaneous fluid-dynamic oscillations could create a hazard in gaseous oxygen flow systems by igniting metal contaminants. The particular fluid-dynamic oscillation studied was the resonance-tube phenomenon as it was excited in a tee-shaped configuration representative of configurations found in many industrial flow systems. Pure aluminum was chosen as the candidate material for ignition. The oscillations in the tee-shaped configuration were compared with oscillations driven by choked convergent nozzles and were found to differ markedly. The temperatures generated at the base of the resonance tube were well in excess of 1000 F for both gaseous oxygen and nitrogen. The effect of inert particulate matter introduced into the resonance tube was to increase significantly the measured temperatures. Aluminum in both powder and fiber form was readily ignited within the resonance tube at pressures less than 1200 psia. At higher pressures, the aluminum-oxygen mixture exploded. This investigation confirms the hazardous nature of resonance-tube oscillations as generated in typical piping configurations that use high-pressure oxygen.

Phillips, B. R.↗

Resonance tube hazards in oxygen systems

An experimental and analytical program was carried out to determine whether fluid dynamic oscillations could create a hazard in gaseous oxygen flow systems. The particular fluid dynamic oscillation studied was the resonance tube phenomena as it was excited in a tee-shaped configuration characteristic of configurations found in many industrial high pressure gas flow systems. The types of hazards that could be caused by the oscillations were direct heating and ignition of the piping system by the gas, the greatly augmented heating that could occur if inert contaminants were present, and the ignition of metallic contaminants. Asbestos was used as the inert contaminant; titanium, aluminum, magnesium and steel were chosen as ignitable metallic contaminants. The oscillations in the tee-shaped configuration were compared to oscillations driven by choked convergent nozzles and were found to differ markedly. Temperature generated at the end or base of the resonance tube exceeded 1089 K for both gaseous oxygen and nitrogen and reached 1645 K when asbestos was added. Aluminum in both powder and fiber form was readily ignited within the resonance tube when the supply pressures were less than 8270 kPa whereas at higher supply pressures the mixture exploded with enough violence to destory the apparatus in less than 10 sec. In addition to aluminum, magnesium, and titanium, samples of 400 series stainless steels were also ignited within the resonance tube. The ignition occurred within a few seconds after the oxygen flow began.

Phillips, B. R.↗