Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEFLON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Teflon, Kapton surface and bulk effects

Two samples of 2 mil aluminized/Kapton thermal blanket and two samples of Teflon were received for evaluation. Their location on the solar maximum is given. The Kapton top layer of the thermal blanket had been exposed to the LEO atomic oxygen environment and shows the surface degradation due to atomic oxygen attack resulting in a diffuse character over most of the surface. The backside Kapton layer which was unexposed appeared to the eye to be in virgin condition. Another sample exhibited similar properties, but was, in large part, covered with Kapton adhesive tape and it was not possible to obtain usable specimens for analysis. One of the Teflon samples which was exposed shows signs of heavy degradation including attack on the Ag/Inconel backside by ultraviolet and atomic oxygen. The other Teflon sample which was unexposed was only slightly fogged on the Teflon side and the Ag/Inconel appeared untouched. These samples were subjected to several chemical and physical analyses, the results of which are discussed.

J C Robinson↗

Degradation studies of SMRM teflon

Teflon samples returned from the Solar Max Satellite (SMS) suffered noticeable damage such as cracking and yellowing. This is in contrast to teflon exposed aboard STS-5 and STS-8 which showed no detectable changes. Selected teflon tape samples from SMS were studied to evaluate the extent and mechanism of degradation. ESCA studies revealed that these teflon samples contain hydrocarbon segments which were susceptible to oxygen atom degradation. Mechanical measurements also showed bulk property changes as a result of LEO exposure. A molecular model of material and energetic oxygen atom interaction was proposed. SMS data and the importance of developing correlation between accelerated exposure data from STS and ground-based testing and real time data will be presented.

Liang, Ranty H.↗

Ground Laboratory Soft X-Ray Durability Evaluation of Aluminized Teflon FEP Thermal Control Insulation

Metallized Teflon fluorinated ethylene propylene (FEP) thermal control insulation is mechanically degraded if exposed to a sufficient fluence of soft x-ray radiation. Soft x-ray photons (4-8 A in wavelength or 1.55 - 3.2 keV) emitted during solar flares have been proposed as a cause of mechanical properties degradation of aluminized Teflon FEP thermal control insulation on the Hubble Space Telescope (HST). Such degradation can be characterized by a reduction in elongation-to-failure of the Teflon FER Ground laboratory soft x-ray exposure tests of aluminized Teflon FEP were conducted to assess the degree of elongation degradation which would occur as a result of exposure to soft x-rays in the range of 3-10 keV. Tests results indicate that soft x-ray exposure in the 3-10 keV range, at mission fluence levels, does not alone cause the observed reduction in elongation of flight retrieved samples. The soft x-ray exposure facility design, mechanical properties degradation results and implications will be presented.

Banks, Bruce A.↗

Ground Laboratory Soft X-Ray Durability Evaluation of Aluminized Teflon FEP Thermal Control Insulation

Metallized Teflon fluorinated ethylene propylene (FEP) thermal control insulation is mechanically degraded if exposed to a sufficient fluence of soft x-ray radiation. Soft x-ray photons (4-8 A in wavelength or 1.55 - 3.2 keV) emitted during solar flares have been proposed as a cause of mechanical properties degradation of aluminized Teflon FEP thermal control insulation on the Hubble Space Telescope (HST). Such degradation can be characterized by a reduction in elongation-to-failure of the Teflon FEP. Ground laboratory soft x-ray exposure tests of aluminized Teflon FEP were conducted to assess the degree of elongation degradation which would occur as a result of exposure to soft x-rays in the range of 3-10 keV. Tests results indicate that soft x-ray exposure in the 3-10 keV range, at mission fluence levels, does not alone cause the observed reduction in elongation of flight retrieved samples. The soft x-ray exposure facility design, mechanical properties degradation results and implications will be presented.

Banks, Bruce A.↗

On-Orbit Teflon(trademark) FEP Degradation

During the Hubble Space Telescope (HST) Second Servicing Mission (SM2), degradation of unsupported Teflon(trademark) FEP (fluorinated ethylene propylene), used as the outer layer of the multi-layer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer was retrieved during the mission and returned to Earth for ground testing and evaluation. The results of the Teflon(trademark) FEP sample evaluation and additional testing of pristine Teflon(trademark) FEP led the investigative team to theorize that the HST damage was caused by thermal cycling with deep-layer damage from electron and proton radiation which allowed the propagation of cracks along stress concentrations, and that the damage increased with the combined total dose of electrons, protons, UV and x-rays along with thermal cycling. This paper discusses the testing and evaluation of the Teflon(trademark) FEP.

Townsend, Jacqueline A.↗

Synchrontron VUV and Soft X-Ray Radiation Effects on Aluminized Teflon FEP

Surfaces of the aluminized Teflon FEP multi-layer thermal insulation on the Hubble Space Telescope (HST) were found to be cracked and curled in some areas at the time of the second servicing, mission in February 1997, 6.8 years after HST was deployed in low Earth orbit (LEO). As part of a test program to assess environmental conditions which would produce embrittlement sufficient to cause cracking of Teflon on HST, samples of Teflon FEP with a backside layer of vapor deposited aluminum were exposed to vacuum ultraviolet (VUV) and soft x-ray radiation of various energies using facilities at the National Synchrotron Light Source. Brookhaven National Laboratory. Samples were exposed to synchrotron radiation of narrow energy bands centered on energies between 69 eV and 1900 eV. Samples were analyzed for ultimate tensile strength and elongation. Results will be compared to those of aluminized Teflon FEP retrieved from HST after 3.6 years and 6.8 years on orbit and will he referenced to estimated HST mission doses of VUV and soft x-ray radiation.

Dever, Joyce A.↗

On-Orbit Teflon FEP Degradation

During the Hubble Space Telescope (HST) Second Servicing Mission (SM2), degradation of unsupported Teflon' FEP (fluorinated ethylene propylene), used as the outer layer of the multi-layer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer was retrieved during the mission and returned to Earth for ground testing and evaluation. The results of the Teflon FEP sample evaluation and additional testing of pristine Teflon FEP led the investigative team to theorize that the HST damage was caused by thermal cycling with deep-layer damage from electron and proton radiation which allowed the propagation of cracks along stress concentrations, and that the damage increased with the combined total dose of electrons, protons, LTV and x-rays along with thermal cycling. This paper discusses the testing and evaluation of the Teflon FEP.

Townsend, Jacqueline A.↗

On-Orbit Teflon(R) FEP Degradation

During the Hubble Space Telescope (HST) Second Servicing Mission (SM2), degradation of unsupported Teflon(R) FEP (fluorinated ethylene propylene), used as the outer layer of the multi-layer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer was retrieved during the mission and returned to Earth for ground testing and evaluation. The results of the Teflon(R) FEP sample evaluation and additional testing of pristine Teflon(R) FEP led the investigative team to theorize that the HST damage was caused by thermal cycling with deep-layer damage from electron and proton radiation which allowed the propagation of cracks along stress concentrations, and that the damage increased with the combined total dose of electrons, protons, UV and x-rays along with thermal cycling. This paper discusses the testing and evaluation of the Teflon(R) FEP.

Townsend, Jacqueline A.↗

Hubble Space Telescope Metallized Teflon(registered trademark) FEP Thermal Control Materials: On-Orbit Degradation and Post-Retrieval Analysis

During the Hubble Space Telescope (HST) Second Servicing Mission (SM2), degradation of unsupported Teflon(Registered Trademark) FEP (fluorinated ethylene propylene), used as the outer layer of the multilayer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer was retrieved during the mission and returned to Earth for ground testing and evaluation. The results of the Teflon(Registered Trademark) FEP sample evaluation and additional testing of pristine Teflon(Registered Trademark) FEP led the investigative team to theorize that the HST damage was caused by thermal cycling with deep-layer damage from electron and proton radiation which allowed the propagation of cracks along stress concentrations , and that the damage increased with the combined total dose of electrons, protons, UV and x-rays along with thermal cycling. This paper discusses the testing and evaluation of the retrieved Teflon(Registered Trademark) FEP.

Townsend, Jacqueline A.↗

On-Orbit Teflon(trademark) FEP Degradation

During the Hubble Space Telescope (HST) Second Servicing Mission (SM2), degradation of unsupported Teflon(trademark) FEP (fluorinated ethylene propylene), used as the outer layer of the multi-layer insulation (MLI) blankets, was evident as large cracks on the telescope light shield. A sample of the degraded outer layer was retrieved during the mission and returned to Earth for ground testing and evaluation. The results of the Teflon(trademark) FEP sample evaluation and additional testing of pristine Teflon FEP led the investigative team to theorize that the HST damage was caused by thermal cycling with deep-layer damage from electron and proton radiation which allowed the propagation of cracks along stress concentrations, and that the damage increased with the combined total dose of electrons, protons, UV and x-rays along with thermal cycling. This paper discusses the testing and evaluation of the Teflon(trademark) FEP.

Townsend, Jacqueline↗

ANALYSIS OF QUARTZ AND TEFLON SHIELDS FOR A PARTICULAR RE-ENTRY MISSION

The transient performance of ablation type heat protection shields is treated herein for the surface of a vehicle returning from outer space to the earth. The vehicle weighs 8640 kg, has a ballistic factor of 500 lb/ft2, re-enters with a speed of 11 km/sec at 120 km altitude, has a lift over drag ratio of -0.5, and is subjected to a maximum deceleration of 7.7 times the gravity constant. By use of well-known equations for the heat transfer and the mass transfer at a heated surface, a numerical calculation method is derived which, for the investigated ablation processes, yields exact transient solutions of the fundamental system of partial differential equations. The method is applied to various quartz shields and to one Teflon shield, which all evaporate so readily under the conditions of the problem at hand that practically no flow of molten shield material exists. The solutions also show comparatively small temperature changes parallel to the surface. The results show that the nose of the vehicle is cooled predominantly by the evaporation of the quartz or the Teflon; the rest of the vehicle's surface is cooled by radiation of the quartz or evaporation of the Teflon. The large mass transfer effects on the nose of the vehicle are detrimental since the resulting low surface temperatures prevent the radiative heat transfer out of the shield, which does not involve any mass loss, from being the desirable governing cooling factor.

ABLATING MATERIAL↗

Evaluation program for secondary spacecraft cells. Initial evaluation tests of General Electric Company standard and teflonated negative electrode 20.0 ampere-hour, nickel-cadmium spacecraft cells with auxiliary electrodes

The standard plate cells exhibited higher average end-of-charge (EOC) voltages than the cells with teflonated negative plates; they also delivered a higher capacity output in ampere hours following these charges. All the cells reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test. The average ampere hours in and voltages at this pressure were 33.6 and 1.505 volts respectively for the teflonated negative plate cells and 35.5 and 1.523 volts for the standard plate cells. All cells exhibited pressure decay in the range of 1 to 7 psia during the last 30 minutes of the 1-hour open circuit stand. Average capacity out for the teflonated and standard negative plate cells was 29.4 and 29.9 ampere hours respectively.

Source record↗

SSM atomic oxygen reactions on Kapton and silverized Teflon

Surface morphology studies using scanning electron microscopy on Kapton and Inconel silver coated Teflon material samples retrieved from the Solar Maximum Mission spacecraft revealed significant changes attributed to orbital atomic oxygen induced reactions. The Kapton recession observed on the aluminized Kapton material samples appeared equivalent in nature with that observed on previous Space Shuttle LEO missions. SSM Teflon taped material samples, coated on the back side with films of Inconel protected silver were observed degraded on both sides. Visibly severe reactions on the back side produced total blackening, generally restricted to areas of tape with a narrow direct view-factor of the external orbital environment. High magnification scanning electron microscope views provided evidence of near total silver reaction, flaking, and subsequent erosion of the underlying Teflon itself. Only three of the extensive S.E.M. photographs illustrating the basic reactions observed are included pending further detailed investigations.

Roger Linton↗

Atomic oxygen interactions with FEP Teflon and silicones on LDEF

The Long Duration Exposure Facility (LDEF) spacecraft represents the first controlled unidirectional exposure of high-fluence atomic oxygen on fluorinated ethylene propylene (FEP Teflon) and silicones. The atomic oxygen erosion yield for FEP Teflon was found to be significantly in excess of previous low fluence orbital data and is an order of magnitude below that of polyimide Kapton. LDEF FEP Teflon erosion yield data as a function of angle of attack is presented. Atomic oxygen interaction with silicon polymers results in crazing of the silicones as well as deposition of dark contaminant oxidation products on adjoining surfaces. Documentation of results and possible mechanistic explanations are presented.

Banks, Bruce A.↗

Fatigue testing of corrugated and Teflon hoses

Single and two-phase heat transport systems for the thermal control of large space facilities require fluid lines that traverse joints and either rotate or move in some other manner. Flexible hoses are being considered as one means of traversing these joints. To test the resilience of flexible hoses to bending stress, a test assembly was constructed to determine the number of flexing cycles the hoses could withstand before losing their ability to maintain a constant pressure. Corrugated metal hoses and Teflon hoses were tested at different pressures with nitrogen gas. The metal hoses had lives ranging from 30,000 to 100,000 flexing cycles. But, even after 400,000 cycles, the Teflon hoses remained essentially intact, though some leakage in the convoluted Teflon is noted.

Benner, Steve M.↗

Atomic oxygen interactions with FEP Teflon and silicones on LDEF

The Long Duration Exposure Facility (LDEF) spacecraft has enabled the measurement of the effects of fixed orientation exposure of high fluence atomic oxygen on fluorinated ethylene propylene (FEP Teflon) and silicones. The atomic oxygen erosion yield for the FEP Teflon was found to be 3.64 x 10(exp -25) cm(exp 3)/atom. This erosion yield is significantly higher than that measured from previous low fluence orbital data. The FEP Teflon erosion yield was found to have the same dependence on oxygen arrival angle as Kapton and Mylar. Atomic oxygen interaction with silicon polymers results in the crazing of silicon. Released silicone contaminants were found to darken upon further atomic oxygen exposure.

Bruce A. Banks↗

Impact penetration experiments in teflon targets of variable thickness

Approximately 20.4 sq m of Teflon thermal blankets on the nonspinning Long Duration Exposure Facility (LDEF) were exposed to the orbital debris and micrometeoroid environment in low-Earth orbit (LEO) for approximately 5.7 years. Each blanket consisted of an outer layer (approximately 125 micron thick) of FEP Teflon that was backed by a vapor-deposited metal mirror (Inconel; less than 1 micron thick). The inner surface consisted of organic binders and Chemglaze thermal protective paint (approximately 50 micron thick) resulting in a somewhat variable, total blanket thickness of approximately 180 to 200 microns. There was at least one of these blankets, each exposing approximately 1.2 sq m of surface area, on nine of LDEF's 12 principal pointing directions, the exceptions being Rows 3, 9, and 12. As a consequence, these blankets represent a significant opportunity for micrometeoroid and debris studies, in general, and specifically they provide an opportunity to address those issues that require information about pointing direction (i.e., spatial density of impact events as a function of instrument orientation). During deintegration of the LDEF spacecraft at KSC, all penetration holes greater than or equal to 300 micron in diameter were documented and were recently synthesized in terms of spatial density as a function of LDEF viewing direction by. The present report describes ongoing cratering and penetration experiments in pure Teflon targets, which are intended to establish the relationships between crater or penetration-hole diameters and the associated projectile dimensions at laboratory velocities (i.e., 6 km/s). The ultimate objective of these efforts is to extract reliable mass-frequencies and associated fluxes of hypervelocity particles in LEO.

Hoerz, F.↗

Penetration experiments in aluminum and Teflon targets of widely variable thickness

The morphologies and detailed dimensions of hypervelocity craters and penetration holes on space-exposed surfaces faithfully reflect the initial impact conditions. However, current understanding of this postmortem evidence and its relation to such first-order parameters as impact velocity or projectile size and mass is incomplete. While considerable progress is being made in the numerical simulation of impact events, continued impact simulations in the laboratory are needed to obtain empirical constraints and insights. This contribution summarizes such experiments with Al and Teflon targets that were carried out in order to provide a better understanding of the crater and penetration holes reported from the Solar Maximum Mission (SMM) and the Long Duration Exposure Facility (LDEF) satellites. A 5-mm light gas gun was used to fire spherical soda-lime glass projectiles from 50 to 3175 microns in diameter (D(sub P)), at a nominal 6 km/s, into Al (1100 series; annealed) and Teflon (Teflon(sup TFE)) targets. Targets ranged in thickness (T) from infinite halfspace targets (T approx. equals cm) to ultrathin foils (T approx. equals micron), yielding up to 3 degrees of magnitude variation in absolute and relative (D(sub P)/T) target thickness. This experimental matrix simulates the wide range in D(sub P)/T experienced by a space-exposed membrane of constant T that is being impacted by projectiles of widely varying sizes.

Hoerz, F.↗