Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEMPERATURE INDICATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Accurate Fe–He machine learning potential for studying He effects in BCC-Fe

Nanostructured Ferritic Alloys (NFAs) containing oxide nanoparticles are prospective advanced structural materials in future fusion reactors. Lacking fusion neutron sources with an adequate flux, modeling is critical to understand radiation damage in the NFAs, including helium effects. Machine learning interatomic potentials (MLPs) have been demonstrated to be capable of describing atomic interactions in chemically complex systems with comparable accuracy to density functional theory (DFT) but with much less computational costs. Hence, MLPs are chosen to study He bubble accumulation in chemically complex NFAs. As a preliminary step, we develop a Fe–He potential, based on ~10,000 atomic configurations. The developed MLP accurately predicts the bulk properties of BCC-Fe compared to DFT, including the lattice constant (2.832 Å), elastic constants (c 11 = 271 GPa, c 12 = 141, c 44 = 93), and phonon frequencies (maximum error < 3.5%). The MLP predicts He binding energies in He n V bubbles and He n clusters with a mean absolute error (MAE) of only ~70 meV, which is ~3 to ~5 times smaller than the MAE of binding energies estimated using empirical potentials. The MLP also accurately predicts the migration barrier of interstitial He (64 meV). Furthermore, the MLP correctly predicts the maximum number of He atoms (critical size) at which a He n V bubble (He n cluster) can kick-out a self-interstitial atom (SIA), forming a bigger He n V 2 bubble (He n V bubble). Subsequently, we use the MLP to perform molecular dynamics simulations to investigate the effect of temperature on the critical size of He n V bubbles and He n clusters. We find that the critical size decreases with increasing temperature — indicating that smaller bubbles and clusters can kick-out an SIA at higher temperatures, thereby escalating the He bubble growth. We report the current Fe–He MLP can be further developed to include all chemical interactions in NFAs.

36 MATERIALS SCIENCE↗

Effect of Melt-Spinning Parameters on the Structure and Properties of Ni 55.5 Mn 18.8 Ga 24 Si 1.7 Heusler Alloy Ribbons

Ni–Mn-based Heusler alloys are known to demonstrate magnetic shape memory and giant magnetocaloric effect (MCE). These effects depend on the phases, crystallographic and magnetic phase transitions, and the crystallographic texture characteristics. These structural characteristics, in turn, are a function of the processing parameters. In the current work, Ni 55.5 Mn 18.8 Ga 24 Si 1.7 Heusler alloy was processed by melt-spinning under a helium atmosphere. This process results in a fine microstructure. The ribbon that was produced with a narrower nozzle width, faster wheel speed, and higher cast temperature, indicating a faster cooling rate, had double the magnetic entropy change close to room temperature. However, the other ribbon demonstrated a large entropy change over a broader temperature range, extending its usability. The effect of the melt-spinning process parameters on the developing microstructure, crystallographic structure and texture, transformation temperatures, and the magnetic entropy change were studied to explain the difference in magnetocaloric behavior.

36 MATERIALS SCIENCE↗

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Dislocation interactions in olivine control postseismic creep of the upper mantle

Changes in stress applied to mantle rocks, such as those imposed by earthquakes, commonly induce a period of transient creep, which is often modelled based on stress transfer among slip systems due to grain interactions. However, recent experiments have demonstrated that the accumulation of stresses among dislocations is the dominant cause of strain hardening in olivine at temperatures ≤600 °C, raising the question of whether the same process contributes to transient creep at higher temperatures. Here, we demonstrate that olivine samples deformed at 25 °C or 1150–1250 °C both preserve stress heterogeneities of ~1 GPa that are imparted by dislocations and have correlation lengths of ~1 μm. The similar stress distributions formed at these different temperatures indicate that accumulation of stresses among dislocations also provides a contribution to transient creep at high temperatures. The results motivate a new generation of models that capture these intragranular processes and may refine predictions of evolving mantle viscosity over the earthquake cycle.

58 GEOSCIENCES↗

Exploring the impact of Cr-doping on the crystallographic and magnetic structure of Mn 5 Si 3 antiferromagnetic alloy

Here, the role of Cr-doping on the structural and magnetic ground states of Mn 5 Si 3 alloy has been investigated through temperature-dependent neutron powder diffraction (NPD) and X-ray absorption fine structure (XAFS) techniques. All the Cr-doped alloys of nominal composition Mn 5-x Cr x Si 3 (for x = 0.05, 0.1, and 0.2) undergo two first-order magneto-structural phase transitions from hexagonal (space group: P6 3 /mcm) paramagnetic → orthorhombic (space group: Ccmm) collinear antiferromagnetic → orthorhombic (space group: Cc2m) non-collinear antiferromagnetic phase on cooling from room temperature. NPD studies at different constant temperatures indicate that both anti ferromagnetic phases are commensurate in nature and can be represented by q = (0,1,0) magnetic propagation vector for all the Cr-doped alloys. Such doping at the Mn-site results in a significant modification of the non-collinear antiferromagnetic structure (both moment size and orientation) and hence affects the unusual magnetic properties, like inverted hysteresis loop, thermomagnetic irreversibility, etc. The XAFS measurements were performed to interpret the local environment of doped Cr atoms in detail, which is critical for a microscopic understanding of the unusual properties of this class of Cr-doped Mn 5 Si 3 alloys. The analysis confirms the elemental state of Cr in the doped alloys and indicates a high degree of preservation of local crystallographic structure with varying Cr concentration and sample temperature. Doping induces intriguing changes in XAFS patterns, elucidated through different types of scattering mechanisms associated with the central absorbing Cr atom.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal transport properties of IrSbSe

Here we report a thermal transport study of IrSbSe, which crystallizes in a noncentrosymmetric cubic structure with the P2 1 3 space group and shows a narrow-gap semiconducting behavior. The large discrepancy between the activation energy for conductivity [E ρ = 128(2) meV] and for thermopower [E S = 17.7 (9) meV] from 200 to 300 K indicates a polaronic transport mechanism. The electrical resistivity varies as exp (T 0 /T) 1/4 and thermopower varies as T 1/2 at low temperatures, indicating that it evolves into Mott variable-range hopping dominant conduction with decreasing temperature. IrSbSe shows a relatively low value of thermal conductivity (~1.65 W/Km) and thermopower of about 0.24 mV/K around 100 K, yet poor electrical conductivity. On the other hand, a high vacancy defect concentration on both Ir and Sb atomic sites of up to 15% suggests a high defect tolerance and points to the possibility of a future improvement of carrier density by chemical substitution or defect optimization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recrystallization driven softening and heating rate dependencies of FeCrAl nuclear fuel cladding during accident transients

A refined understanding of FeCrAl cladding behavior during rapid transients is critical for its potential deployment in light-water reactors. Current assessments focus on transient burst testing metrics such as balloon geometry, burst temperature, and hoop stress, often used as proxies for simpler conventional tensile properties. However, directly correlating isothermal tensile and creep data with accident transient scenarios remains a challenge, although it is essential for high fidelity model development. Recent modeling based on tensile tests up to 800 °C, conducted with both immediate loading and a 10-minute soak, showed that immediate loading better predicts experimental burst temperatures, indicating a thermal softening effect. Building upon this observation, the current study connects transient performance, microstructural evolution, and high-temperature tensile properties by leveraging results from C26M claddings burst tests performed at heating rates of 1–50 °C/s and hoop stresses from 25 to 100 MPa. At 25 MPa, rupture temperatures varied by only 6 °C, but at 100 MPa, the difference reached 116 °C, with faster heating yielding higher burst temperatures. Microstructural analysis identified recrystallization as the primary cause of heating rate-dependent softening, eliminating prior cold-working. In-situ thermomechanical data linked ballooning onset to localized instabilities, similar to ultimate tensile strength behavior in conventional tensile tests. High heating rates correlated with immediate loading tensile data, while lower rates matched soaked data. Furthermore, by linking burst performance to microstructural evolution and tensile properties, this work provides a foundation for more accurate modeling of FeCrAl claddings and potentially other Fe-based materials under accident conditions.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal transport in phase-stabilized lithium zirconate phosphates

The thermal properties of yttrium-stabilized lithium zirconate phosphate [LZP: Li 1+x+y Y x Zr 2-x (PO 4 ) 3 with x = 0.15, -0.2 ≤ y ≤ 0.4 and with x = 0.0, y = 0.0] are presented over a wide temperature range from 30 to 973 K, elucidating the interplay between structural phase transformations and thermal properties in a solid state superionic conducting material. At room temperature, the thermal conductivity decreases by more than 75% as the stoichiometry is changed from lithium deficient to excess and increases with increasing temperature, indicative of defect-mediated transport in the spark plasma sintered materials. The phase transformations and their stabilities are examined by x-ray diffraction and differential scanning calorimetry and indicate that the Y3 + substitution of Zr 4+ is effective in stabilizing the ionically conductive rhombohedral phase over the entire temperature range measured, the mechanism of which is found through ab initio theoretical calculations. Finally, these insights into thermal transport of LZP superionic conductors are valuable as they may be generally applicable for predicting material stability and thermal management in the ceramic electrolyte of future all-solid-state-battery devices.

36 MATERIALS SCIENCE↗

Effect of Mg doping on carrier recombination in GaN

Time-resolved photoluminescence measurements have been performed on Mg-doped GaN for Mg concentrations in the low- to mid-10 19 cm -3 . As-grown and annealed (600–675 °C) samples were studied. In the as-grown samples, the nonradiative carrier lifetime was found to be about 200 ps and nearly independent of the Mg concentration. Upon annealing, the carrier lifetimes shorten to ~150 ps but, again, show little dependence on the annealing temperature. The analysis of possible Shockley–Read–Hall recombination centers and their behavior during doping and annealing suggests that the main nonradiative recombination center is the Mg–nitrogen vacancy complex. The weak dependence of the PL decay times on temperature indicates that carrier capture into this center has a very low potential barrier, and the nonradiative recombination dominates even at low temperatures.

36 MATERIALS SCIENCE↗

Water vapor oxidation behaviors of nuclear graphite IG-110 for a postulated accident scenario in high temperature gas-cooled reactors

Water leakage in accidental conditions of high temperature gas-cooled reactors is one of the most critical problems that can compromise the integrity of different nuclear components. In this study, oxidation behaviors of nuclear graphite IG-110 in water ingress accidental conditions were investigated. Mass loss and oxidation rates were evaluated after oxidation tests at temperatures up to 1400 °C in an Ar-20 vol% H 2 O mixed atmosphere. The activation energy decreased from 318.6 to 148.9 kJ/mol with temperature, indicating two different oxidation regimes. The cross-sections of the oxidized samples were systematically characterized. The corresponding logarithmic porosity profiles showed a temperature dependency. Pore formation moved toward near-surface regions with increasing temperature and preferential binder oxidation, with filler particle degradation. Furthermore, oxidant concentration profiles and oxidation depths were estimated using a theoretical model and compared with the experimental results. This work provides important benchmark data and safety analysis guidance for the accident scenario in high temperature gas-cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Predicting fatal heat and humidity using the heat index model

A unique wet-bulb temperature of 35°C is often used as the threshold for human survivability, but recent experiments have shown that a person’s core temperature starts to rise at a wide range of critical wet-bulb temperatures. Here, it is shown that the model underlying the heat index correctly predicts those critical wet-bulb temperatures, explaining 95% of the variance in the values observed in laboratory heat-stress experiments. This is the first time the heat-index model has been validated against physiological data from laboratory experiments. For light and moderate exertion in an indoor setting, the heat index model predicts that the critical wet-bulb temperature ranges from 20 to 32°C, depending on the relative humidity, consistent with experimental results. Furthermore, for the same setting and exertion, the heat index model predicts fatal wet-bulb temperatures ranging from 24 to 37°C. Recent experiments have identified the critical combinations of heat and humidity, in an indoor setting, above which an individual is unable to maintain a standard core temperature, indicating severe heat stress. It is shown here why this state of severe heat stress cannot be predicted using the wet-bulb temperature. Instead, it is shown that the recently extended heat index model can explain nearly all of the variance in the observed critical combinations of temperature and humidity, and can be used to calculate fatal combinations.

59 BASIC BIOLOGICAL SCIENCES↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal modifications of mesons and energy-energy correlators from real-time simulations of a 𝑈⁡(1) lattice gauge theory

We investigate thermal properties of a 𝑈⁡(1) lattice gauge theory in 1 + 1 dimensions through real-time simulations. We extract the spectral functions directly coupling to the pseudoscalar and scalar mesons, demonstrating the thermal modifications of these states with increasing temperatures. Introducing the notion of energy-flow operators, we quantify the temporal buildup of correlations in the energy flows across the lattice. We demonstrate that energy-energy correlators fail to factorize to products of energy flows, both in the vacuum and at nonzero temperature, indicating the presence of nontrivial correlations in the quantum states. Our results constitute a first real-time ab initio study of bound-state thermal broadening and finite temperature energy-flow correlations in a gauge theory, providing a benchmark for future studies of hadronic matter under extreme conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Protist Predation Influences the Temperature Response of Bacterial Communities

Temperature strongly influences microbial community structure and function, in turn contributing to global carbon cycling that can fuel further warming. Recent studies suggest that biotic interactions among microbes may play an important role in determining the temperature responses of these communities. However, how predation regulates these microbiomes under future climates is still poorly understood. Here, we assess whether predation by a key global bacterial consumer—protists—influences the temperature response of the community structure and function of a freshwater microbiome. To do so, we exposed microbial communities to two cosmopolitan protist species—Tetrahymena thermophila and Colpidium sp.—at two different temperatures, in a month-long microcosm experiment. While microbial biomass and respiration increased with temperature due to community shifts, these responses changed over time and in the presence of protists. Protists influenced microbial biomass and respiration rate through direct and indirect effects on bacterial community structure, and predator presence actually reduced microbial respiration at elevated temperature. Indicator species analyses showed that these predator effects were mostly determined by phylum-specific bacterial responses to protist density and cell size. Our study supports previous findings that temperature is an important driver of microbial communities but also demonstrates that the presence of a large predator can mediate these responses to warming.

59 BASIC BIOLOGICAL SCIENCES↗

New precious metal containing normal spinels: LiRhRu 1-x Ir x O 4 , LiFeIr 1-x Ru x O 4 , and LiCoIr 1-x Ru x O 4

Large spin-orbit-coupled cations in geometrically frustrated crystal structures have the most suitable setting for exploring novel exotic states of matter. Spinel oxides (AM 2 O 4 ) are well-known examples of geometrically frustrated systems. In this study, we report for the first time the synthesis of compositions LiRhRu 1-x Ir x O 4 (x = 0–0.5), LiFeIr 1-x Ru x O 4 (x = 0–0.5), and LiCoIr 1-x Ru x O 4 (x = 0–0.3) containing precious metal cations on edge-sharing octahedral M-sites, and systematically investigate their magnetic and electrical properties. 57 Fe Mössbauer spectroscopy revealed that iron is trivalent in all LiFeIr 1-x Ru x O 4 solid solutions. Magnetic measurements indicate deviations from theoretical spin-only magnetic moment values, indicating the influence of spin-orbit coupling owing to the presence of 4d and 5d block elements. The LiFeIr 1-x Ru x O 4 series shows spin-glass-like freezing behavior with T g ≈ 20 K, and a small frustration index (f ≈ 1-2), indicating that the frustration originates from site disorder. LiRhRu 1-x Ir x O 4 and LiCoIr 1-x Ru x O 4 exhibit strongly geometrically frustrated magnetism. Electrical resistivity measurements as a function of temperature indicate that all phases are semiconducting. Seebeck coefficient measurements show that LiRhRu 1-x Ir x O 4 and LiFeIr 1-x Ru x O 4 are p-type semiconductors with holes as the major charge carriers. A sign reversal of the Seebeck coefficient indicates both holes and electrons as carriers for LiCoIr 1-x RuxO 4 (x = 0–0.2), but only holes as major carriers for x = 0.3. Here, the Seebeck coefficient and power factor increase drastically in the LiRhRu 1-x Ir x O 4 solid solution with Ir substitution, reaching a maximum of ≈ +125 μV/K and ≈2.3×10 -6 W/mK 2 at ∼650 K for x = 0.5.

Charge carriers↗

Energetics of CO 2 and H 2 O adsorption on alkaline earth metal doped TiO 2

The process of CO 2 and H 2 O adsorption on the surface of nano-oxide semiconductors is important in the overall performance of artificial photosynthesis and other applications. In this study, we explored the thermodynamics of CO 2 and H 2 O adsorption on TiO 2 as a function of surface chemistry. We applied gas adsorption calorimetry to investigate the energetics of adsorption of those molecules on the surface of anatase nanoparticles. In an attempt to increase TiO 2 surface affinity to CO 2 and H 2 O, TiO 2 was doped with alkaline earth metals (MgO, CaO, SrO, and BaO) by manipulating the chemical synthesis. Adsorption studies using diffuse reflectance infrared spectroscopy at different temperatures indicate that due to the segregation of alkaline earth metals on the surface of TiO 2 nanoparticles, both CO 2 and subsequent H2O adsorption amounts could be increased. CO 2 adsorbs in two different manners, forming carbonates which can be removed at temperatures lower than 700 °C, and a more stable linear adsorption that remains even at 700 °C. Additionally to the surface energetic effects, doping also increased specific surface area, resulting in further improvement in net gas adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of Play Fairway Analysis of the geothermal potential of Camas Prairie, south-central Idaho, by an exploration well

Abstract Play Fairway Analysis (PFA) methodology was adapted for geothermal exploration at Camas Prairie, Idaho. Geophysical data, structural and geologic mapping, volcanic rock ages and vent locations, and the distribution of thermal springs and wells all indicated a relatively high geothermal potential along the southern margin of the Prairie. An exploration well (USU Camas-1) was drilled to a depth of 618.3 m to validate the PFA. A permeable zone was encountered at ~ 357.5 m with a maximum measured temperature of ~ 80 °C, which was suppressed following the injection of cold water. A moderate transmissivity of ~ 0.25–1 cm 2 /s estimated from an injection test as well a seasonal artesian flow at ~ 0.7 L/s corroborate the presence of a permeable zone. The existence of a lacustrine clay seal was confirmed near the bottom of the basin-fill sediment occupying the upper 314 m of the well. Geothermometers suggest the USU Camas-1 well water equilibrated at a reservoir temperature of ~ 120 °C. Based on the locations of both thermal and cold wells, geothermal fluids appear to be flowing upward along one or both of two fault systems. The presence of young basalts and elevated helium isotope ratios suggest that the heat source of Camas Prairie is magmatic. However, the faults may be acting as a conduit for geothermal fluids to rise from great depth without a shallow magmatic source being present. Camas Prairie is a promising area for geothermal development, but the relatively low reservoir temperatures indicate this resource may not be suitable for electric generation. Perhaps the best use would be for heating.

Lachmar, Thomas E. (ORCID:0000000249640119)↗

Near-Field Passive Wireless Sensor for High-Temperature Metal Corrosion Monitoring

This work focuses on the fabrication and evaluation of a passive wireless sensor for the monitoring of the temperature and corrosion of a metal material at high temperatures. An inductor–capacitor (LC) resonator sensor was fabricated through the screen printing of Ag-based inks on dense polycrystalline Al 2 O 3 substrates. The LC design was modeled using the ANSYS HFSS modeling package, with the LC passive wireless sensors operating at frequencies from 70 to 100 MHz. The wireless response of the LC was interrogated and received by a radio frequency signal generator and spectrum analyzer at temperatures from 50 to 800 °C in real time. The corrosion kinetics of the Cu 110 was characterized through thermogravimetric (TGA) analysis and microscopy images, and the oxide thickness growth was then correlated to the wireless sensor signal under isothermal conditions at 800 °C. The results showed that the wireless signal was consistent with the corrosion kinetics and temperature, indicating that these two characteristics can be further deconvoluted in the future. In addition, the sensor also showed a magnitude- and frequency-dependent response to crack/spallation events in the oxide corrosion layer, permitting the in situ wireless identification of these catastrophic events on the metal surface at high temperatures.

36 MATERIALS SCIENCE↗