Search NASA⌕ Search

SEARCH · Search NASA

Results for “TES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mars Aerocapture and Validation of Mars-GRAM with TES Data

Mars Global Reference Atmospheric Model (Mars-GRAM) is a widely-used engineering- level Mars atmospheric model. Applications include systems design, performance analysis, and operations planning for aerobraking, entry descent and landing, and aerocapture. Typical Mars aerocapture periapsis altitudes (for systems with rigid-aeroshell heat shields) are about 50 km. This altitude is above the 0-40 km height range covered by Mars Global Surveyor Thermal Emission Spectrometer (TES) nadir observations. Recently, TES limb sounding data have been made available, spanning more than two Mars years (more than 200,000 data profiles) with altitude coverage up to about 60 km, well within the height range of interest for aerocapture. Results are presented comparing Mars-GRAM atmospheric density with densities from TES nadir and limb sounding observations. A new Mars-GRAM feature is described which allows individual TES nadir or limb profiles to be extracted from the large TES databases, and to be used as an optional replacement for standard Mars-GRAM background (climatology) conditions. For Monte-Carlo applications such as aerocapture guidance and control studies, Mars-GRAM perturbations are available using these TES profile background conditions.

Justus, C. G.↗

Processing TES Level-1B Data

TES L1B Subsystem is a computer program that performs several functions for the Tropospheric Emission Spectrometer (TES). The term "L1B" (an abbreviation of "level 1B"), refers to data, specific to the TES, on radiometric calibrated spectral radiances and their corresponding noise equivalent spectral radiances (NESRs), plus ancillary geolocation, quality, and engineering data. The functions performed by TES L1B Subsystem include shear analysis, monitoring of signal levels, detection of ice build-up, and phase correction and radiometric and spectral calibration of TES target data. Also, the program computes NESRs for target spectra, writes scientific TES level-1B data to hierarchical- data-format (HDF) files for public distribution, computes brightness temperatures, and quantifies interpixel signal variability for the purpose of first-order cloud and heterogeneous land screening by the level-2 software summarized in the immediately following article. This program uses an in-house-developed algorithm, called "NUSRT," to correct instrument line-shape factors.

DeBaca, Richard C.↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

On-Orbit Performance of the TES Pulse Tube Cryocooler System and the Instrument - Six Years in Space

The Tropospheric Emission Spectrometer (TES) instrument pulse tube cryocoolers began operation 36 days after launch of the NASA Earth Observing System (EOS) Aura spacecraft on July 15, 2004. TES is designed with four infrared Mercury Cadmium Telluride focal plane arrays in two separate housings cooled by a pair of Northrup Grumman Aerospace Systems (NGAS) single-stage pulse tube cryocoolers. The instrument also makes use of a two-stage passive cooler to cool the optical bench. The instrument is a high-resolution infrared imaging Fourier transform spectrometer with 3.3-15.4 micron spectral coverage. After four weeks of outgassing, the instrument optical bench and focal planes were cooled to their operating temperatures to begin science operations. During the early months of the mission, ice contamination of the cryogenic surfaces including the focal planes led to increased cryocooler loads and the need for periodic decontamination cycles. After a highly successful 5 years of continuous in-space operations, TES was granted a 2 year extension. This paper reports on the TES cryogenic system performance including the two-stage passive cooler. After a brief overview of the cryogenic design, the paper presents detailed data on the highly successful space operation of the pulse tube cryocoolers and instrument thermal design over the past six years since the original turn-on in 2004. The data shows the cryogenic contamination decreased substantially to where decontamination cycles are now performed every six months. The cooler stroke required for constant-temperature operation has not increased indicating near-constant cooler efficiency and the instrument's thermal design has also provided a nearly constant heat rejection sink. At this time TES continues to operate in space providing important Earth science data.

cryocoolercraft↗

The Effects of Normal Metal Stripes on TES Performance

Exploring the effects of size and geometry of normal metal features on the transition shapes and performance of transition-edge sensor microcalorimeters. The spectral resolution of transition-edge sensor (TES) microcalorimeters is very sensitive to the specific dependencies of the resistance R in the superconducting transition on the current I, magnetic field B, and temperature T. In particular, it has been shown that transitions that are very steep in (R,T) space lead to a significant noise term, in excess of conventional expectations. This so-called unexplained noise is known to be reduced by the addition of normal metal stripes across the TES perpendicular to the direction of current flow. These normal metal stripes have been shown to drastically alter the oscillatory patterns seen in measurements of the critical current as a function of magnetic field. However, there are many remaining questions about the exact impact of the stripes on current distributions within the TES, the Fraunhofer pattern and, therefore, the shape of the R(I, B, T) surface. Through measurements of the resistance under DC bias of TES devices of various sizes, with different stripe patterns and dimensions, we will discuss how these stripes can affect the R(I, B, T) surface. In addition, using measurements and analysis of the noise spectra of various devices we will present how these changes to the stripe pattern may affect the performance of the TES. In particular, we will discuss strategies to reduce the presence of localized discontinuities in the derivative of R, associated with increased noise, while maintaining the globally low levels of unexplained noise currently achieved with conventional metal stripe patterns. Implementing these strategies is a path towards producing large arrays with highly uniform transitions and high spectral resolution. These large uniform arrays will be required for future x-ray astronomy applications, such as the X-IFU on ATHENA.

TES↗

(Ag{sub 2}TeS{sub 3}){sub 2} {small_bullet} A{sub 2}S{sub 6} (A = Rb, Cs) : layers of silver thiotellurite intergrown with alkali-metal polysulfides.

The layered compounds RbAg{sub 2}TeS{sub 6} and CsAg{sub 2}TeS{sub 6} crystallize in the noncentrosymmetric space group P6{sub 3}cm, with a = 19.15 {angstrom}, c = 14.64 {angstrom}, and V = 4648 {angstrom}{sup 3} and a = 19.41 {angstrom}, c = 14.84 {angstrom}, and V = 4839 {angstrom}{sup 3}, respectively. The structures are composed of neutral [Ag{sub 2}TeS{sub 3}] layers alternating with charge-balanced salt layers containing polysulfide chains of [S{sub 6}]{sup 2-} and alkali-metal ions. RbAg{sub 2}TeS{sub 6} and CsAg{sub 2}TeS{sub 6} are air- and water-stable, wide-band-gap semiconductors (E{sub g} {approx} 2.0 eV) exhibiting nonlinear-optical second-harmonic generation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mini-TES Observations of Comanche Carbonate and Its Distribution

The discovery by the Spirit rover of outcrops rich in Mg-Fe carbonate [Morris et al., 2010] represents another manifestation of a diverse aqueous history in Gusev crater. In 2005, observations by the Moessbauer spectrometer (MB) on outcrops dubbed Comanche provided initial indication of Fe-Mg carbonate that was subsequently supported by analysis of elemental data from the Alpha Particle X-ray Spectrometer (APXS). The recognition of a carbonate component in thermal infrared spectra measured by the Miniature Thermal Emission Spectrometer (Mini-TES) was significantly delayed due to dust contamination of the instrument's optics. With the implementation of a viable dust correction, the Comanche spectra were revisited and presented clear and compelling evidence for a Mg-Fe carbonate component that could be as much as a third of the total mineral abundance. The data from all three instruments in combination are best matched by Mg-Fe carbonate with an abundance of 16-34 wt%. Mini-TES spectra were acquired for 12 targets at various locations on the Comanche (4-5 m long) and Comanche Spur (1-2 m long) outcrops, the latter being the location of the MB and APXS measurements. The two outcrops are spectrally comparable and share similar morphology and texture based on color images from the Panoramic Camera (Pancam). The highest quality Mini-TES spectrum comes from the larger Comanche outcrop on a target named Saupitty. Linear least squares modeling of the Saupitty spectrum employed a library of laboratory spectra tailored for consistency with the APXS and MB data and included spectra representing Martian dust, a slope spectrum to account for any temperature determination errors, and a blackbody spectrum to account for differences in spectral contrast between the laboratory and Mini-TES spectrum. Successful modeling of the Comanche Saupitty spectrum required one or more carbonate phases to obtain a good fit. Excluding all carbonates from the full starting library more than doubled the root-mean-squared error of the model fit (0.147% vs. 0.299%). Because Mg-Fe carbonate and Ca-Mg carbonate (dolomite) are so spectrally similar over the range used for modeling, both provide a comparable fit. However, Carich carbonates like dolomite are precluded based on APXS data and are inconsistent with MB results. The Comanche carbonate rocks are stratigraphically above a set of olivine-rich volcaniclastic rocks known as Algonquin class that mantle the Haskin Ridge feature of the Columbia Hills. Based on ~50 Mini-TES observations, the Comanche outcrops are the only rocks that host abundant carbonate. However, a target at the base of the larger Comanche outcrop appears spectrally transitional between the carbonate and olivine units. This transitional spectral character applies to additional outcrops a few 10s of meters away from Comanche that also appear stratigraphically transitional. Additional work will attempt to establish whether we are seeing an alteration horizon or depositional unit associated with the emplacement Comanche carbonate.

Ruff, Steven W.↗

Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.

Gottardi, L.↗

The Doppler Wind Temperature Sensor (DWTS) Flight Evaluation and Experiments (TES-16,17)

The Doppler Wind Temperature Sensor instrument (DWTS), developed by Global Atmospheric Technologies and Sciences (GATS), is a powerful yet simple tool with the potential of becoming a new window to upper atmosphere dynamics. Based around a defense-grade infrared camera peering through a static gas cell used as a scanning spectral filter, the DWTS is designed to measure the fingerprints of wind and thermal waves as they propagate to the mesosphere and lower thermosphere. DWTS achieves this scanning by measuring the induced change in the doppler shift of the emission as it passes through the DWTS field of view. DWTS holds promise to aid in more accurate weather determination (Gordley, et al), and the core technology can be easily adapted to study other atmospheres of interest. In partnership with GATS, NOAA, and other collaborators, NASA Ames and the Nano Orbital Workshop group have been working to evaluate the DWTS instrument on orbit and optimize it as a flexible cube satellite payload. The first mission selected for DWTS evaluation is preparing for flight in early 2024, followed by a more capable science mission in 2025, with both missions part of the TES-n/NOW flight series. The first flight, TES-16/DWTS-A, will incorporate a single DWTS instrument in an approximately 2U payload volume with the imaging aperture perpendicular to the flight velocity vector. With an estimated power consumption of 20 watts, supplied via a custom NOW-designed GaN converter, the instrument will maintain the imaging sensor plane at 80K using an integrated pulse-tube cryocooler during instrument evaluation periods. Data from DWTS will be captured via a NOW-designed custom data processor before being transmitted via S-band radio back to select ground stations, with instrument command and control operated via L-band global-coverage radio. After the TES-16/DWTS-A initial demonstration mission, the subsequent TES-17/DWTS-B mission will be a dedicated science mission equipped with three DWTS instruments, each hosting a different gas cell to obtain full altitude coverage from 20 to 200 km both day and night from a single cube satellite. The intention of the flight series, and one of NASA’s interests in the instrument, is to advance a Martian atmospheric instrument (Colaprete, Gordley, et al) which, if successful, would greatly further understanding of Martian atmospheric behavior. The proposed paper will review the flight series in detail, including challenges from the TES-16 flight tests and the projected challenges and application to Mars study. Additional detail regarding the possible applications of a Cognitive Communication technique in current flight development by NOW collaborators at the NASA Glenn Research Center will also be discussed, including the implications of using an automated User Initiated Service (UIS) protocol to maximize the data collected per orbit.

Doppler Wind Temperature Sensor↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID

The superconducting transition-edge sensor (TES) detectors have been the standard in cosmic microwave background (CMB) experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this article, we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. Here, we find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance, and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.

CUPID↗

Global Carbon Monoxide Products from Combined AIRS, TES and MLS Measurements on A-Train Satellites

This study tests a novel methodology to add value to satellite data sets. This methodology, data fusion, is similar to data assimilation, except that the background modelbased field is replaced by a satellite data set, in this case AIRS (Atmospheric Infrared Sounder) carbon monoxide (CO) measurements. The observational information comes from CO measurements with lower spatial coverage than AIRS, namely, from TES (Tropospheric Emission Spectrometer) and MLS (Microwave Limb Sounder). We show that combining these data sets with data fusion uses the higher spectral resolution of TES to extend AIRS CO observational sensitivity to the lower troposphere, a region especially important for air quality studies. We also show that combined CO measurements from AIRS and MLS provide enhanced information in the UTLS (upper troposphere/lower stratosphere) region compared to each product individually. The combined AIRS-TES and AIRS-MLS CO products are validated against DACOM (differential absorption mid-IR diode laser spectrometer) in situ CO measurements from the INTEX-B (Intercontinental Chemical Transport Experiment: MILAGRO and Pacific phases) field campaign and in situ data from HIPPO (HIAPER Pole-to-Pole Observations) flights. The data fusion results show improved sensitivities in the lower and upper troposphere (20-30% and above 20%, respectively) as compared with AIRS-only version 5 CO retrievals, and improved daily coverage compared with TES and MLS CO data.

combined AIRS↗

The Doppler Wind and Temperature Sounder (DWTS) Flight Evaluation and Experiments (TES-16,17)

The Doppler Wind and Temperature Sounder instrument (DWTS) developed by Global Atmospheric Technologies and Sciences (GATS) is a simple yet powerful tool with the potential to become a new window through which the study of upper atmosphere dynamics can occur. Based around a defense-grade infrared camera peering through a static gas cell used as a scanning spectral filter, a DWTS instrument can infer wind velocities and kinetic temperatures throughout the stratosphere and lower thermosphere. The DWTS achieves this scanning by measuring the induced Doppler shift and Doppler broadening of emissions as they pass through the DWTS field of view (Gordley, Marshall, 2011). The DWTS holds promise in improving accuracy in weather determination among other terrestrial benefits, and the core technology can be easily adapted to study the dynamics of other planetary atmospheres. In partnership with GATS, NOAA, and other collaborators, NASA Ames and the Nano-Orbital Workshop (NOW) group have been working to evaluate the DWTS instrument on orbit and optimize it as a flexible payload for nanosatellites. The first mission selected for DWTS technical evaluation is preparing for flight in early 2024, which will be followed by a more capable science mission in 2025, with both missions being part of the TES-n/NOW heritage flight series. The first rapid technology demonstration flight, TES-16/DWTS-A, will demonstrate a single DWTS instrument in an approximately 2U payload volume. With an estimated power consumption of 50 watts, the instrument will maintain the imaging sensor plane at 80K during instrument performance evaluation periods using an integrated Stirling cryocooler. Data from DWTS will be captured and processed via a NOW-designed custom data interface unit before being transmitted via S-band radio back to select ground stations, with instrument command and control maintained via L-band global-coverage radio. The subsequent TES-17/DWTS-B mission will be a dedicated science mission tasked with validating the instrument’s full altitude coverage capabilities, currently estimated from 20 to 200 km during both day and night. This new atmospheric observational capability will come from a single small satellite equipped with three DWTS imagers, each hosting a different gas cell chemistry, to form a complete instrument. The intention of this flight series, and one of NASA’s interests in this instrument, is not only to advance Earth atmospheric dynamics, but to advance a Martian atmospheric study instrument as well (Colaprete, Gordley, et al) which, if successful, would greatly further understanding of Martian atmospheric dynamics. This document describes the flight series in detail, including challenges facing the TES-16 flight tests and the projected challenges and application of Mars study. Additional detail regarding the possible applications of a Cognitive Communication technique in current flight development by NOW collaborators at the NASA Glenn Research Center is also discussed, including the implications of using an automated User Initiated Service (UIS) protocol to maximize the data collected per orbit.

DWTS Nano-satellite TES-n↗

TES X-ray Spectrometer at SLAC LCLS-II

We are building a transition edge sensor (TES) X-ray spectrometer for the Linac Coherent Light Source (LCLS-II) at SLAC National Accelerator Laboratory (SLAC) to coincide with new upgrades for this free electron laser facility. This new X-ray spectrometer will have 1000 TES pixels with 0.5 eV energy resolution for soft X-rays below 1 keV. Multiplexing will be done with microwave SQUID resonators and new specialized electronic hardware developed at SLAC. This spectrometer will use a dilution refrigerator to achieve lower operating temperatures than previous TES spectrometers and will be coupled to the liquid jet endstation at LCLS-II. The spectrometer is designed to operate at much higher count rates than previous TES X-ray spectrometers to take advantage of the high repetition rate of the LCLS-II. Science applications will utilize the high photon collection efficiency and throughput, high energy resolution, as well as its ability to simultaneously measure its full calibrated energy range.

47 OTHER INSTRUMENTATION↗

Site demonstration and performance evaluation of MPC for a large chiller plant with TES for renewable energy integration and grid decarbonization

Thermal energy storage (TES) for a cooling plant is a crucial resource for load flexibility. Traditionally, simple, heuristic control approaches, such as the storage priority control which charges TES during the nighttime and discharges during the daytime, have been widely used in practice, and shown reasonable performance in the past benefiting both the grid and the end-users such as buildings and district energy systems. However, the increasing penetration of renewables changes the situation, exposing the grid to a growing duck curve, which encourages the consumption of more energy in the daytime, and volatile renewable generation which requires dynamic planning. The growing pressure of diminishing greenhouse gas emissions also increases the complexity of cooling TES plant operations as different control strategies may apply to optimize operations for energy cost or carbon emissions. This paper presents a model predictive control (MPC), site demonstration and evaluation results of optimal operation of a chiller plant, TES and behind-meter photovoltaics for a campus-level district cooling system. The MPC was formulated as a mixed-integer linear program for better numerical and control properties. Compared with baseline rule-based controls, the MPC results show reductions of the excess PV power by around 25%, of the greenhouse gas emission by 10%, and of peak electricity demand by 10%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterizing and Modeling the Noise and Complex Impedance of Feedhorn-Coupled TES Polarimeters

We present results from modeling the electrothermal performance of feedhorn-coupled transition edge sensor (TES) polarimeters under development for use in cosmic microwave background (CMB) polarization experiments. Each polarimeter couples radiation from a corrugated feedhorn through a planar orthomode transducer, which transmits power from orthogonal polarization modes to two TES bolometers. We model our TES with two- and three-block thermal architectures. We fit the complex impedance data at multiple points in the TES transition. From the fits, we predict the noise spectra. We present comparisons of these predictions to the data for two TESes on a prototype polarimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplexing Readout of TES Microcalorimeters Based on Analog Baseband Feedback

A TES microcalorimeter array is a promising spectrometer with excellent energy resolution and a moderate imaging capability. To realize a large format array in space, multiplexing the TES signals at the low tempersture stage is mandatory. We are developing frequency division multiplexing (FDM) based on baseband feedback technique. In FDM, each TES is AC-biased with a different carrier frequency. Signals from several pixels are summed and then read out by one SQUID. The maximum number of multiplexed pixels are limited by the frequency band in which the SQUID can be operated in a flux-locked loop, which is {approx}1 MHz with standard flux-locked loop circuit. In the baseband feedback, the signal ({approx}10 kHz band) from the TES is once demodulated. Then a reconstructed copy of the modulated signal with an appropriate phase is fed back to the SQUID input coil to maintain an approximately constant magnetic flux. This can be implemented even for large cable delays and automatically suppresses the carrier. We developed a prototype electronics for the baseband feedback based on an analog phase sensitive detector (PSD) and a multiplier. Combined with Seiko 80-SSA SQUID amp, open-loop gain of 8 has been obtained for 10 kHz baseband signal at 5 MHz carrier frequency, with a moderate noise contribution of 27pA/{radical}(Hz) at input.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TES development for a frequency selective bolometer camera.

We discuss the development, at Argonne National Laboratory (ANL), of a four-pixel camera with four spectral channels centered at 150, 220, 270, and 360 GHz. The scientific motivation involves photometry of distant dusty galaxies located by Spitzer and SCUBA, as well as the study of other millimeter-wave sources such as ultra-luminous infrared galaxies, the Sunyaev-Zeldovich effect in clusters, and galactic dust. The camera incorporates Frequency Selective Bolometer (FSB) and superconducting Transition-Edge Sensor (TES) technology. The current generation of TES devices we examine utilizes proximity effect superconducting bilayers of Mo/Au, Ti, or Ti/Au as TESs, located along with frequency selective absorbing structures on silicon nitride membranes. The detector incorporates lithographically patterned structures designed to address both TES device stability and detector thermal transport concerns. The membrane is not perforated, resulting in a detector which is comparatively robust mechanically. In this paper, we report on the development of the superconducting bilayer TES technology, the design and testing of the detector thermal transport and device stability control structures, optical and thermal test results, and the use of new materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗