At least 37 records · Page 2

A 90GHz Bolometer Camera Detector System for the Green

We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3 mm) for the 100m Green Bank Telescope (GBT). This system will provide high sensitivity (less than 1mJy in 1s) rapid imaging (15'x15' to 150 micron Jy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close-packed, Nyquist-sampled array of superconducting transition edge sensor (TES) bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approximately 2 x 10(exp -17) W/square root of Hz, the TES bolometers will provide fast, linear, sensitive response for high performance imaging. The detectors are read out by an 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.

Benford, Dominic J.↗

Scalable Background-Limited Polarization-Sensitive Detectors for mm-wave Applications

We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and on-chip filters are employed to define the detection bandwidth. A hybridized integrated enclosure reduces the high-frequency THz mode set that can couple to the TES bolometers. An implementation of the detector architecture at Q-band achieves 90% efficiency in each polarization. The design is scalable in both frequency coverage, 30-300 GHz, and in number of detectors with uniform characteristics. Hence, the detectors are desirable for ground-based or space-borne instruments that require large arrays of efficient background-limited cryogenic detectors.

Millimeter-Wave Detectors↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background(CMB)science depend on increasing the number of sensitive detectorsobserving the sky. New instruments deploy large arrays of superconducting transition-edge sensor(TES)bolometers tileddensely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers andsimplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexingfactor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, whichemploys microwave SQUID multiplexing(μmux). Simons Observatory will use 49 modules containing 70,000bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design,presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor.The median white noise of each readout channel is 65pA Hz. This impacts the projected SO mapping speed by<8%,which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. Wediscuss the measured performance in the context of SO science requirements, which are exceeded.

Heather McCarrick↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A microwave SQUID multiplexer optimized for bolometric applications

A microwave SQUID (superconducting quantum interference device) has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/ $\sqrt{Hz}$, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mirror Illumination and Spillover Measurements of the Atacama Cosmology Telescope

The Atacama Cosmology Telescope (ACT) is a 6 m telescope designed to map the Cosmic Microwave Background (CMB) simultaneously at 145 GHz, 220GHz and 280GHz, The receiver in ACT, the Millimeter Bolometer Array Camera, features 1000 TES bolometers in each band, The detector performance depends critically on the total optical loading, requiring the spmover contributions from the optics to be minimal. This inspired the use of a cold Lyot stop to limit the illumination of the primary and the use of guard rings surrounding the primary and secondary reflectors. Here, we present a direct measurement of the illumination aperture for both reflectors and of the attenuation level outside the main optical path. We used a 145 GHz, 1 m W source and a chopper wheel to produce a time-varying signal with a broad heam proflle, We sampled the response of the camera for different locations of the source, placed in front and beside the primary and secondary mirrors. The aperture of the primary was measured to be 5,72 plus or minus 0,17m in diameter (95 plus or minus 3% of its geometrical size), while the aperture of the secondary yielded 2 plus or minus 0.12m in diameter. Both apertures are consistent with the optical design. Comparing to previous measurements of the beam solid angle from planet observations, we estimate an optical efficiency of 72.3 plus or minus 4,8%. We found that the attenuation outside the primary aperture was -16 plus or minus 2dB, which is below the theoretical expectations, and -22 plus or minus 1 dB outside the secondary aperture, which is consistent with simulations. These results motivated the extension of the baffles surrounding the secondary mirror, with the following reduction in detector optical loading from 2,24 pW to 188pW.

Gallardo, Patricio↗

Advanced ACTPol Multichroic Polarimeter Array Fabrication Process for 150 mm Wafers

Advanced ACTPol (AdvACT) is a third-generation cosmic microwave background receiver to be deployed in 2016 on the Atacama Cosmology Telescope (ACT). Spanning five frequency bands from 25 to 280 GHz and having just over 5600 transition-edge sensor (TES) bolometers, this receiver will exhibit increased sensitivity and mapping speed compared to previously fielded ACT instruments. This paper presents the fabrication processes developed by NIST to scale to large arrays of feedhorn-coupled multichroic AlMn-based TES polarimeters on 150-mm diameter wafers. In addition to describing the streamlined fabrication process which enables high yields of densely packed detectors across larger wafers, we report the details of process improvements for sensor (AlMn) and insulator (SiN(sub x)) materials and microwave structures, and the resulting performance improvements.

Atacama Cosmology Telescope(ACT)↗

Assembly and Integration Process of the High-Density Detector Array Readout Modules for the Simons Observatory

The Simons Observatory will measure the cosmic microwave background tempera-ture and polarization using a suite of new telescopes in the Atacama Desert in Chile. The Simons Observatory will use dichroic transition edge sensor (TES) bolometer arrays spanning six frequency bands from 27 to 280 GHz. The Simons Observa-tory will pioneer the use of a densely packed multiplexing architecture based on the microwave SQUID multiplexer ( 𝜇mux), housing ∼2000 microwave resonators, each coupled to a TES. The Simons Observatory aims to multiplex each array of ∼2000 detectors with a single pair of coaxial cables and requires a multiplexing factor of ∼1000 . The Simons Observatory cryogenic readout system is called the universal microwave multiplexing module (UMM). The UMM couples to both horn and lenslet-coupled detector arrays and is integrated into the universal focal-plane module (UFM) after being independently characterized. We present processes we have developed for highly repeatable and automated integration methods of UMMs, which will be needed for the production of the 49 UFMs required for the first stage of the Simons Observatory.

CMB↗

Deployment of POLARBEAR-2b

POLARBEAR-2b (PB-2b) is the second receiver in the Simons Array, a cosmic microwave background (CMB) polarization experiment. The Simons Array uses dichroic polarization sensitive lenslet-coupled sinuous antennas and transition-edge sensor (TES) bolometers made of superconducting films. These bolometers are read out with frequency multiplexing electronics. PB-2b contains ~7500 detectors in two bands at 90 and 150 GHz with arcminute resolution. The polarization of these detectors is modulated by a cryogenic continuously rotating half-wave plate. PB-2b was installed on its telescope in 2022 in the Atacama Desert at an altitude of 5.2 km. This paper will detail initial readout commissioning, test of a new loopgain monitoring method, and focusing the optics. Work is ongoing to commission the remaining ambient temperature readout electronics, measure detector time constants, and observe with the cryogenic half-wave plate spinning.

47 OTHER INSTRUMENTATION↗

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION↗

The Cosmology Large Angular Scale Surveyor (CLASS): 40 GHz Optical Design

The Cosmology Large Angular Scale Surveyor (CLASS) instrument will measure the polarization of the cosmic microwave background at 40, 90, and 150 GHz from Cerro Toco in the Atacama desert of northern Chile. In this paper, we describe the optical design of the 40 GHz telescope system. The telescope is a diffraction limited catadioptric design consisting of a front-end Variable-delay Polarization Modulator (VPM), two ambient temperature mirrors, two cryogenic dielectric lenses, thermal blocking filters, and an array of 36 smooth-wall scalar feedhorn antennas. The feed horns guide the signal to antenna-coupled transition-edge sensor (TES) bolometers. Polarization diplexing and bandpass definition are handled on the same microchip as the TES. The feed horn beams are truncated with 10 dB edge taper by a 4 K Lyot-stop to limit detector loading from stray light and control the edge illumination of the front-end VPM. The field-of-view is 19 deg x 14 deg with a resolution for each beam on the sky of 1.5 deg. FWHM.

Eimer, Joseph R.↗

On-chip Broadband Load Calibrators for Characterizing Transition-Edge Sensor Bolometers

We describe the design and fabrication of on-chip broadband load calibrators for element-by- element and full circuit characterization of transition-edge sensor (TES) bolometers for cosmic microwave background (CMB) polarimetry. Fabricated in a 4 X 4 grid on a 100 mm silicon wafer, the chips allow systematic testing of individual detector circuit elements without the need for an external blackbody source. This in-situ testing approach provides rapid and efficient characterization of various pixel designs in order to optimize the optical efficiency and control of systematic effects of the detectors. In this work, we demonstrate the on-chip calibrators on the Cosmology Large Angular Scale Surveyor (CLASS) W-band pixels. In particular, we investigate the loss on microstrip transmission lines and measure the performance of various designs of TESs, magic-tees, via-less crossovers, and signal terminations. We also test a filter-bank spectrometer with eight resonators spanning 80 – 105 GHz to characterize the spectral response of circuit elements across the detector bandwidth.

Sumit Dahal↗

Particle Response of Antenna-Coupled TES Arrays: Results from SPIDER and the Laboratory

Future mm-wave and sub-mm space missions will employ large arrays of multiplexed transition-edge-sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce ‘glitches’ in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. Here, we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences and give a preliminary look at pulse shapes in laboratory data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband Direct Detection Submillimeter Spectrometer with Multiplexed Superconducting Transition Edge Thermometer Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers as direct detectors (i.e., with cold electrons) for spectroscopy. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer for the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE has been operated in the 350 Am (850 GHz) band. These bands cover line emission from the important star formation tracers neutral carbon [CI] and carbon monoxide (CO).

Benford, D. J.↗

Design of A Transition-Edge-Sensor-Based Thermal Stabilization Stage

Electrothermal feedback in a transition edge sensor suppresses thermal fluctuations in the TES and regions in close thermal contact. We designed a heavily-metallized, leg-isolated membrane with a TES which serves as a thermal stabilization stage that can be lithographically integrated with other devices. Through modeling, fabrication and test of prototype devices, we examine whether the noise reduction in this stage can reduce thermal fluctuations (e.g. 1/f noise) in the other components by providing a more stable base temperature. In one implementation, a leg-isolated TES bolometer of higher superconducting transition temperature (Tc) is encircled by a second membrane region which is metallized and thermally stabilized by a second, lower-Tc TES. We present fabrication results on the dual-Tc design and testing of the simultaneous biasing of a two-stage, two-TES device. We explore varied heat capacity of the thermally stabilized stage in the single pixel design. We also present other designs to evaluate the use of an outer thermal stabilization stage for multiple pixel arrangements.

Rachel Borrelli↗

A 90GHz Bolometer Camera Detector System for the Green Bank Telescope

We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3mm) for the 100 m Green Bank Telescope (GBT) This system will provide high sensitivity (<1mjy in 1s rapid imaging (15'x15' to 250 microJy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close packed, Nyquist-sampled array of superconducting transition edge sensor bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approx. 2.10(exp 17) W/square root Hz, the TES bolometers will provide fast linear sensitive response for high performance imaging. The detectors are read out by and 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.

Benford, Dominic J.↗