Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST FIRING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development of Self-Assembly Supports Enabling Transformational Membrane Performance for Cost-Effective Carbon Capture

This final technical report describes work conducted by Membrane Technology and Research, Inc. (MTR) for the U.S. Department of Energy (DOE), National Energy Technology Lab (NETL) on the development of membranes with transformational performance for carbon capture under award number DE-FE0031596. The work was performed from June 1, 2018 through May 31, 2024. For more than a decade, MTR has worked in partnership with DOE to develop an innovative membrane-based CO 2 capture process. This effort has included the first test of membrane modules with coal-fired flue gas at the Arizona Public Services (APS) Cholla plant in 2010; the accumulation of >11,000 hours of flue gas operation for Polaris modules on a bench-scale 1 tonne/day (TPD) system at the National Carbon Capture Center (NCCC); scale-up of first-generation (Gen-1) Polaris to a 20 TPD small pilot system, and successful operation of this system on a flue gas slipstream at NCCC and in integrated boiler testing at Babcock & Wilcox (B&W). Through continued development efforts, a second-generation (Gen-2) version of the Polaris membrane has been scaled-up to pilot production. This membrane offers 70% higher CO 2 permeance with similar selectivity to the base case Polaris. MTR also developed planar modules designed specifically for the low-pressure, high-volumetric flow rate process conditions of flue gas operation. These new modules have significantly lower pressure-drop values compared to the type originally used (spiral-wound modules), which results in significant energy savings. The goal of the work described in this report was to improve on the Polaris Gen-2 membrane with the ultimate aim to reduce the cost of carbon capture. The majority of the effort was to develop improved support membranes for the multi-layer composite structure of MTR’s Polaris membrane. Earlier work at MTR had identified the support structure as limiting membrane permeances, not because the support itself represents a permeation resistance, but because the distribution of pores at the surface of the support imposes a geometric restriction to diffusion in the layers above it. Support membranes were prepared from a range of polymers, including commercially available block copolymers and a custom synthesized block copolymer alternative. The best support membranes developed in this project reduced the geometric restriction by a factor of two to three. These supports then were used to produce Polaris composite membranes with improved permeances. The second topic was to create a high-selectivity version of the Polaris membrane. The high-selectivity version uses a novel selective polymeric material and high selectivities were confirmed in experiments at MTR. The material is not easily made into very thin films. Consequently, the permeances are significantly lower than the Polaris Gen-2 membrane. The utility of this membrane is therefore limited to the carbon dioxide purification step that produces liquid CO 2 . A Technical and Economic Analysis (TEA) was performed for a carbon capture system that uses both advanced membrane types. The TEA shows the novel advanced membranes reduce the cost of capture by 10%, from $63.32/tonne CO 2 to $56.90/tonne CO 2 (2022 USD). Most of the development work was carried out with laboratory-scale casting and coating equipment. A number, but not all, of the improvements identified have been implemented on commercial-scale manufacturing equipment. The focus of future work at MTR is to incorporate the advancements made into the Polaris membrane manufacturing process.

01 COAL, LIGNITE, AND PEAT↗

When Do Riverine Systems “Feel the Burn”? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export

Wildfires impact terrestrial landscapes and downstream river corridors through shifts in vegetation and soil properties leading to downstream hydrologic and water quality impacts. The magnitude of these impacts depend on a complex and interconnected set of wildfire, landscape, and aquatic processes. Here, we isolate the impact of post-fire hydrologic changes on streamflow, nitrate, and dissolved organic carbon using the Soil and Water Assessment Tool (SWAT) model. We explore how responses differ across burn severity and area burned in two test basins: a humid forested basin and a semi-arid mixed land use basin. We ran 1830 wildfire simulations testing impacts of area burned, burn severity, and post-fire precipitation on streamflow, nitrate, and dissolved organic carbon. Our work suggests that area burned thresholds differ with burn severity and analyte. Additionally, post-fire transport of dissolved organic carbon was sensitive to both area burned and severity, while nitrate was primarily sensitive to area burned. Despite a muted (−9.5 to 5.7 mm yr −1 change) hydrologic response in the semi-arid basin, the model predicted large (7%–288% increase) shifts in dissolved organic carbon, suggesting that post-fire shifts in flow pathways and soil properties are key in its response. The limited shifts in nitrate responses in the simulations highlight that terrestrial post-fire transformations, rather than hydrologic changes, may control the increases in stream nitrate often observed post-fire. As wildfire regimes are shifting, improving understanding of post-fire nutrient export responses is critical to protect freshwater resources and aquatic ecosystems.

Wampler, Katherine A. [Pacific Northwest National ↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

Tritium Containment Vessel Response to Thermal and Mechanical Abuse Environments for Fire Safety Assessments

This report evaluates leakage behavior from tritium containment vessels under thermal abuse and combined thermal-mechanical abuse conditions to better understand safety implications for releases occurring in a fire scenario. Surrogate gases were used for all tests in this report. Leakage through the valves from thermal pressurization was observed when heating rates >0.8°C/s were sustained to >300°C. Gas plumes were visualized from vessels that were heated above 260°C and then dropped.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wireless Patch Antenna Characterization for Live Health Monitoring Using Machine Learning

Temperature monitoring in extreme environments, such as coal-fired power plants, was addressed by designing and testing wireless patch antennas for use in machine learning-aided temperature estimation. The sensors were designed to monitor the temperature and health of boiler systems. Wireless interrogation of the sensor was performed using a Vector Network Analyzer (VNA) and a pair of interrogation antennas to capture resonance behavior under varying thermal and spatial conditions with sensitivities ranging from 0.052 to 0.20 $\frac{𝑀𝐻𝑧}{°C}$. Sensor calibration was conducted using a Long Short-Term Memory (LSTM) model, which leveraged temporal patterns to account for hysteresis effects. The calibration method demonstrated improved performance when combined with an LSTM model, achieving up to a 76% improvement in temperature estimation error when compared with Linear Regression (LR). The experiments highlighted an innovative solution for patch antenna-based non-contact temperature measurement, which addresses limitations with conventional methods such as RFID-based systems, infrared, and thermocouples.

20 FOSSIL-FUELED POWER PLANTS↗

Benchmarking MELCOR's NAC Package to ABCOVE Test AB7

This report presents analyses of the AB7 ABCOVE sodium spray fire experiment with the MELCOR code. This code simulates the progression of accident events for analysis and auditing purposes of nuclear facilities during accident conditions. Historically, the ABCOVE experiments have contributed to the validation of aerosol physics and related phenomena. Given advancements in sodium-cooled reactor designs, characterization of the sodium spray combustion may further the review and validation of newly incorporated sodium properties and physics packages, namely, the sodium equations of state (EOS) and the sodium combustion (NAC) package within MELCOR. Previously, the AB5 and AB6 experiments were analyzed with and without the NAC package. This work builds on the previous analyses with a demonstration of the current code capabilities of MELCOR with a more mild Na spray and pool fire scenario.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CalTestBed - Delphire - Testing and Evaluation of Delphire Sentinel System (CRADA Final Report)

The Delphire Sentinel is a modular fire detection and communications system operating as a mobile field unit, with low voltage DC power supplied by onboard photovoltaics (PV) and batteries. The Sentinel addresses several aspects of fire detection, communications and data analysis. The Sentinel's mobility enables it to be rapidly deployed and operate independently of existing power and communications networks. The duration of independent operation depends critically on the energy consumption of the systems and performance of the onboard PV and battery. The purpose of this testing is to ascertain the power draw and energy consumption of the Delphire Sentinel prototype system under several operational states, including various data transfer packet sizes, transmission time and frequencies, and communication pathways (Wi-Fi, cellular, satellite) expected to be encountered in field deployments. It will also include procedures to test the ability of the Sentinel to operate for extended periods without loss of functionality. Based on results from energy and power measurements, and anticipated duty cycles in field deployments, we will model annual system autonomy (e.g. loss of load probability) for off-grid operation in representative locations.

47 OTHER INSTRUMENTATION↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of Deuterium Oxidation in a Room with a Fire

A series of experiments where deuterium was released in trace amounts into a room with a fire were performed at Sandia National Laboratories. This report describes the corresponding effort to model the test series using SIERRA/FUEGO. The objective of this modeling effort was to produce a simulation test matrix that can be utilized to help interpret the corresponding experiments and be used to assess the credibility of using the SIERRA/FUEGO simulations as a surrogate for real tritium reaction data for mock fire and release studies. The simulations assessed multiple configurations of fire size and location and overall found that there was low conversion of deuterium to oxidized deuterium. There are some notable differences between the simulation predictions and the experimental results, such as the simulations generally predicting higher amounts of deuterium conversion compared to the experiment. A strategy to address modeling uncertainties and unknowns is also given in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Degradation and Accelerated Recovery of Surface Passivation in n+, p+, and Intrinsic Poly-Si/SiOx Passivating Contacts for Silicon Solar Cells

We report on the degradation and recovery of surface passivation of fired poly-Si/SiOx passivating contacts with hydrogen containing Al2O3 during annealing in the dark and under illumination. Upon firing to a peak temperature of 670 degrees C, the iVoc for symmetric test structures with n+, p+, and intrinsic poly-Si/SiOx contacts decreases due to a loss of surface passivation. Upon further annealing over the temperature range of 200-350 degrees C in the dark, depending on the type of doping, the surface passivation either shows further degradation followed by recovery, or direct recovery to the initial iVoc. Annealing at higher temperatures and/or higher illumination intensities accelerates the kinetics for both degradation and recovery processes. We show that the degradation and recovery processes are thermally activated and proceed identically in subsequent firing and annealing steps showing their cyclic nature. We present a series reaction model to explain the kinetics of degradation and recovery processes for n+ and intrinsic poly-Si/SiOx contacts. By fitting the model's rate expressions to the data, the determined effective activation energy barriers for degradation and recovery for n+ poly-Si/SiOx contacts in the dark are 1.24 and 1.51 eV, which are lowered under 7.5 Suns illumination to 0.76 and 1.15 eV, respectively.

14 SOLAR ENERGY↗

A High-Voltage High-Current Benchtop Test Stand for Solid-State Switch Testing at the SNS

Solid-state switches already replaced thyratrons in the SNS extraction kicker power supplies, offering improved efficiency and reliability. However, recent supply chain disruptions, combined with a self-firing issue, led us to explore alternative solutions. A vendor-developed MOS-Gated Thyristor switch was introduced but ultimately failed during testing. To investigate the failure and assess possible improvements, a benchtop test stand was constructed to evaluate the performance of a single stage board. This test stand features a Pulse Forming Network (PFN) that operates at 6 kV and 6 kA, with a repetition rate exceeding 60 Hz, simulating real operational conditions. By utilizing this setup, we seek to gain a better understanding of the failure mechanisms, refine the switch designs, and ultimately develop a more reliable alternative for the extraction kicker power supplies.

Bullman, Austin [ORNL]↗

Development and Reliability of Screen-Printable Fire-Through Cu Paste for Passivated Contact Solar Cells

We present the development of copper (Cu) paste which has been screen printed on Selective Emitter-Passivated Emitter Rear Contact (SE-PERC) solar cells. This paste can also be applied to Tunnel Oxide Passivated Contact (TOPCON) solar cells due to its fire-through nature. Champion PERC cells have achieved ....efficiency with ...parameters . Accelerated testing to investigate reliability performance of the SE- PERC mini-modules were carried out in damp heat chamber with 85oC and 85% humidity. The devices were found to be operational even after 1,500 hours. Devices with screen printed Ag contacts on the front side have been studied in parallel to the Cu contacts for comparison.

copper paste↗

lllinois Storage Corridor CarbonSAFE Phase III: Pre-drilling Site Assessment: Prairie State Generating Company

The Illinois Storage Corridor project will drill a stratigraphic test well as part of the Illinois Storage Corridor CarbonSAFE Phase 3 project near the Prairie State Generating Company coal-fired power plant near Marissa, Illinois. The pre-drilling site evaluation has considered the primary target reservoirs, the Potosi Dolomite and St. Peter Sandstone, and primary seal, the Maquoketa Group. Data to be collected from the well include core, fluid samples, in situ well tests, geophysical logs intended to provide information on lithologic, geomechanical, and geophysical characteristics to determine the feasibility for the geologic sequestration of 50 million metric tons or more of injected carbon dioxide. The planned drilling site has been evaluated using available subsurface geologic data and analyses from the Illinois Basin. These data provide lithologic and structural information, shallow groundwater resource distribution, location of known nearby wellbores, and regional drilling characteristics. The data were used to generate geologic structure and isopach maps for the target reservoir and caprock strata and for prognosing the tops of major lithologic units to aid drilling and coring procedures. The regional analyses indicate that no known structural features are expected to negatively impact the target storage reservoir or caprock. No protected and sensitive areas, groundwater resources, or existing resource development are expected to be impacted by the proposed well drilling activities. The well is planned to be drilled to a total depth of approximately 5,600 feet (1,707 m) and terminate in the Precambrian. Cores (up to 5 intervals) will be collected from the Maquoketa Group, confining units above the St. Peter Sandstone, St. Peter Sandstone, confining units of the Potosi Dolomite and the Potosi Dolomite. Water samples will be attempted to be collected from the St. Peter Sandstone and Potosi Dolomite. Potential impact on drilling progress is a lost circulation zone in the Potosi Dolomite, which has been demonstrated to have intermittent cavernous porosity from karstification elsewhere in the Illinois Basin. This document also presents a preliminary coring and sampling program, proposed logging suite, and well testing program, all of which will be reviewed during drilling.

01 COAL, LIGNITE, AND PEAT↗

Airborne LiDAR to Improve Canopy Fuels Mapping for Wildfire Modeling

Increasing conflict between wildfire and the built environment has increased the need for more up-to-date and finer resolution canopy fuels data to improve wildfire modeling and associated risk forecasts. The US Forest Service and US Department of the Interior’s LANDFIRE product, which provides 30-m resolution canopy fuels data for the entire US, is one of the most widely used sources of fuels data. However, the last complete mapping effort for LANDFIRE is based on 2016 conditions, and subsequent updates reflect disturbances 1-2 years behind the release year. Airborne systems equipped with Light Detection and Ranging (LiDAR) sensors can be deployed to actively sense canopy structure and estimate canopy fuels data (cover, height, base height, bulk density) at finer resolutions. Canopy base height (CBH) and canopy bulk density (CBD) are difficult to measure both in the field and in LiDAR point clouds. Still, they are important for accurately modeling crown fires, which are often intense and difficult to contain. Additionally, point cloud datasets are large, and calculations require efficient utilization of computational resources. To address these challenges, we are working on an approach that uses openly available National Ecological Observatory Network (NEON) airborne LiDAR data, with calculations processed in the R programming language and parallelized through the lidR package. CBH and CBD are often derived from tree height, diameter at breast height, and species-specific allometries using the Fire and Fuels Extension of the Forest Vegetation Simulator (FFE-FVS). We aim to test if airborne LiDAR can estimate CBH and CBD without the use of empirical equations. Reliable estimates of canopy fuels data directly from airborne LiDAR could streamline quick, fine-resolution updates for use in wildfire behavior models.

54 ENVIRONMENTAL SCIENCES↗

A Simulator for Neyer Tests of Explosives

Explosives and explosive devices such as detonators are typically tested by applying a range of stimuli such as voltage or mechanical shock, and recording binary “detonated/did not detonate” responses. These are analyzed using maximum likelihood or generalized linear models to provide estimates of quantities such as the all-fire and no-fire points. Given that the true threshold for detonation is unknown a priori , sequential design methods are typically used to optimize the set of test points. One popular method, implemented in commercial software, is Neyer’s algorithm. To support simulation and experimental design, we have developed code in the R programming language to duplicate the functions of the Neyer software. We provide code for the simulator along with a description and examples of usage.

42 ENGINEERING↗

Quantifying and Optimizing the Energy Benefits of Mass Timber Construction

The International Mass Timber Alliance (IMTA) is a global organization of industry leaders, engineers, scientists, and associations dedicated to advancing mass timber construction. Its mission is to generate and disseminate scientific data supporting the development of standardized construction and energy efficient practices that promote the adoption of mass timber worldwide. IMTA collaborated with Oak Ridge National Laboratory (ORNL) to leverage ORNL’s expertise in building envelope modeling and testing to evaluate how mass timber construction can reduce peak heating and cooling demand, lower overall energy use, and improve resilience during power outages. A previous study of 80 mass timber buildings in Finland found measured energy use up to 50% lower than predicted by simulation. This project aimed to validate and extend those findings for U.S. buildings through analytical modeling, laboratory testing, and full-scale building evaluations. The research focused on the thermal performance of low-embodied-energy wall assemblies, such as cross-laminated timber (CLT) panels and log walls, with particular attention to the effects of thermal inertia on indoor comfort and energy performance. While mass timber’s structural and fire-resistance properties are well documented, its whole-building thermal behavior has received limited attention. Field data, simulation results, and resilience testing from this study will inform future modeling practices, design guidelines, and construction practices by quantifying the unique thermal and demand-flexibility benefits of mass timber construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fire and Thermal Experiments in Support of the Model Evaluation Protocol for LNG Facility Fires

The motivation for the experiments reported here pertains to the siting of Liquefied Natural Gas (LNG) facilities which requires assessing the potential adverse radiant thermal impacts of accidental fires on the public. The objective is to obtain data on jet fires, pool fires, fireballs, and concrete walls that could serve as thermal barriers for model validation. The fuels tested include ethane, ethylene, propane, and isopentane.

42 ENGINEERING↗