Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEXAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mercury Control for Plants Firing Texas Lignite and Equipped with ESP-wet FGD

This report presents the results of a multi-year test program conducted as part of Cooperative Agreement DE-FC26-06NT42779, 'Mercury Control for Plants Firing Texas Lignite and Equipped with ESP-wet FGD.' The objective of this program was to determine the level of mercury removal achievable using sorbent injection for a plant firing Texas lignite fuel and equipped with an ESP and wet FGD. The project was primarily funded by the U.S. DOE National Energy Technology Laboratory. EPRI, NRG Texas, Luminant (formerly TXU), and AEP were project co-funders. URS Group was the prime contractor, and Apogee Scientific and ADA-ES were subcontractors. The host site for this program was NRG Texas Limestone Electric Generating Station (LMS) Units 1 and 2, located in Jewett, Texas. The plant fires a blend of Texas lignite and Powder River Basin (PRB) coal. Full-scale tests were conducted to evaluate the mercury removal performance of powdered sorbents injected into the flue gas upstream of the ESP (traditional configuration), upstream of the air preheater, and/or between electric fields within the ESP (Toxecon{trademark} II configuration). Phases I through III of the test program, conducted on Unit 1 in 2006-2007, consisted of three short-term parametric test phases followed by a 60-day continuous operation test. Selected mercury sorbents were injected to treat one quarter of the flue gas (e.g., approximately 225 MW equivalence) produced by Limestone Unit 1. Six sorbents and three injection configurations were evaluated and results were used to select the best combination of sorbent (Norit Americas DARCO Hg-LH at 2 lb/Macf) and injection location (upstream of the ESP) for a two-month performance evaluation. A mercury removal rate of 50-70% was targeted for the long-term test. During this continuous-injection test, mercury removal performance and variability were evaluated as the plant operated under normal conditions. Additional evaluations were made to determine any balance-of-plant impacts of the mercury control process, including those associated with ESP performance and fly ash reuse properties. Upon analysis of the project results, the project team identified several areas of interest for further study. Follow-on testing was conducted on Unit 2 in 2009 with the entire unit treated with injected sorbent so that mercury removal across the FGD could be measured and so that other low-ash impact technologies could be evaluated. Three approaches to minimizing ash impacts were tested: (1) injection of 'low ash impact' sorbents, (2) alterations to the injection configuration, and (3) injection of calcium bromide in conjunction with sorbent. These conditions were tested with the goal of identifying the conditions that result in the highest mercury removal while maintaining the sorbent injection at a rate that preserves the beneficial use of ash.

01 COAL, LIGNITE, AND PEAT↗

Disposal of Greater Than Class C Low-Level Radioactive Waste in Andrews County, Texas - 16408

The U.S. Nuclear Regulatory Commission (NRC) staff has recommended approval of an initiative to permit the Texas Commission on Environmental Quality (TCEQ) to license the disposal of commercial and co-mingled Greater Than Class C Low-Level Radioactive Waste (GTCC LLW) in Andrews County, Texas. Such a framework is clearly articulated in the Section 274 of the Atomic Energy Act of 1954, as amended. The NRC staff also recommended approval to proceed with a rulemaking to align the Waste Classification Tables in Title 10 of the Code of Federal Regulations (CFR), Part 61.55 with the paragraph 61.2 definition of 'waste' to provide a disposal pathway for waste containing certain alpha-emitting transuranic elements with concentrations exceeding 100 nanocuries per gram (nCi/g). A pathway for the disposal of commercial and co-mingled GTCC LLW, including waste with certain alpha emitting transuranic elements exceeding 100 nCi/g (TRU waste), might emerge if the initiative described in the Commissions' July 22, 2015 document, SECY-15-0094, Historical and Current Issues Related to Disposal of GTCC LLW, is approved. The NRC staff recommendations envisioned the NRC and TCEQ working together to review a site-specific performance assessment that would be submitted by Waste Control Specialists LLC (WCS) as part of an amendment to its existing Radioactive Materials License No. R04100. The TCEQ's recommendations were prompted by a petition for rulemaking filed by WCS to allow the disposal of GTCC waste in Texas. On September 10, 2014, the TCEQ Commissioners directed their staff to engage stakeholders and request input from the NRC and the U.S. Department of Energy (DOE) regarding actions needed to proceed with any future rulemaking. On January 30, 2015, the TCEQ requested clarification from the NRC regarding their legal authority and jurisdiction to regulate GTCC, GTCC-like, and TRU waste. The deliberations that have transpired over the past year have raised important legal, policy, and technical matters. This initiative could provide a safe disposal pathway for certain waste streams that have been orphaned over the past 30 years. One important realization that has emerged is the conservative assumptions used to establish the upper limits for Class C LLW when Part 61 was promulgated in 1981 would be much too restrictive when applied to a modern, highly engineered disposal facility located in arid west Texas. Waste that was not suitable for near surface disposal in 1981 could certainly be demonstrated to be safely disposed at the WCS Federal Waste Disposal Facility in Andrews County, Texas. This paper will address the legal, policy, and technical matters supporting this important topic currently under consideration both nationally and within the State of Texas. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Geothermal Resources in Three Texas Counties

This project updates the geothermal resources beneath our oil and gas fields, as part of the research for the Texas GEO project. This report "Analysis of Geothermal Resources in Three Texas Counties" (October 2020) improves on previous mapping of the Texas resources for the counties of Crockett (West Texas), Jackson (central Gulf Coast) and Webb (South Texas). Through additional bottom-hole temperatures (BHT), the number of well sites increased from 532 to 5,410 in total for these counties. The improved methodology to calculate formation temperatures from 3.5 km (11,500 ft) to 10 km (32,800 ft) includes thermal conductivity values more closely related to the actual county geological formations, incorporated radiogenic heat production of formations, and the related mapped depth to basement. The results show deep temperatures as hotter than previously calculated, with temperatures of 150 degrees Celcius possible for Webb County between depths of 2.6 - 5.1 km, Jackson County between depths 3.0 - 5.4 km, and Crockett County between depths of 2.7 - 8.0 km.

10 km↗

Assessing the complex influences of water management on hydrological drought characteristics in Texas

The state of Texas in the United States is highly susceptible to drought. Its major rivers are subject to extensive water management (WM) activities in order to sustain multisectoral water demands, particularly during drought conditions. However, the impact of WM on the propagation dynamics and characteristics of hydrological drought (HD) in Texas remains unclear. To fill this gap, this study quantifies the influence of WM across 32 streamflow gauges along the mainstems of seven major rivers in Texas by comparing a variety of drought metrics under natural and managed conditions. Notably, we leveraged an extensive, naturalized streamflow dataset constructed by the Texas Commission on Environmental Quality, paired with gauge observations of managed conditions. Results indicate that at the multi-decadal scale, WM significantly reduced HD frequency across all seven rivers and at 81% of the gauges analyzed. Additionally, it increased the response timescale of HD across Texas’ major rivers by a median of 2.5 months. Conversely, the average-event duration and severity increased in most locations. Temporal analysis reveals that the WM impact on HD varied seasonally, with attenuation effects during mid-summer and early fall and intensification effects during late winter and spring. Additionally, WM was found to greatly increase the spatial variability of HD characteristics across the region. These findings emphasize the complexity of WM effects on HD and the necessity for nuanced strategies in managing HD under WM influences.

54 ENVIRONMENTAL SCIENCES↗

An Update On Waste Control Specialists' 2004 License Application For Safe Disposal Of Class A, B, and C Low-Level Radioactive Waste In Texas

On December 10, 2007, Waste Control Specialists LLC (WCS) received notification that the Executive Director of the Texas Commission on Environmental Quality (TCEQ) had prepared an interim draft license and made a preliminary decision that it met all statutory and regulatory requirements for safe disposal of low-level radioactive waste (LLW) at the WCS' site in Texas. Pursuant to this interim draft license, WCS will be authorized to dispose Class A, B, and C LLW in two enhanced near-surface landfills at WCS' 5.4-square-kilometer (1,338-acre) treatment, storage, and disposal (TSD) site in Andrews County, Texas (Fig. 1). One landfill will be dedicated to LLW generated within the member/party states of the Texas Compact (Texas and Vermont), while the other will be dedicated to LLW generated by the federal government. The calculated annual peak dose to the maximally exposed member of the general public, i.e., an adjacent resident, from any of the proposed LLW-disposal landfills occurs approximately 36,400 years after closure and is 0.034 milli-sievert (mSv) (3.4 milli-rem (mrem)), which is less than 14 percent of the applicable regulatory limit of 25 mSv (25 mrem). The draft license will be published in February 2008, which will be followed by 12 months of public hearings, and three months for preparation of the final license. Based on this schedule, the final license is due in May 2009. When opened, the WCS site will achieve a national milestone; it will be the first new Compact LLW-disposal site in the USA to open under the Low-Level Radioactive Waste Policy Act of 1980, as amended in 1985. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser Network US Experiments at the University of Texas at Austin

Under Subcontract B638654, The University of Texas at Austin (UT Austin) Center for High Energy Density Science supported three Laser Network US experiments and conducted upgrade planning for the Texas Petawatt Laser Facility. For the experiment “Investigation of the physics of MeV X-ray and particle generation using Compound Parabolic Concentrators” led by Dr. Andrew Mackinnon of Lawrence Livermore National Laboratory, UT Austin provided postdoctoral associate support in the person of Dr. Ganesh Tiwari. For the experiments “Megatesla magnetic fields and enhanced gamma-ray beam generation” led by Hans Rinderknecht of LLE, University of Rochester (experiment) and Alexey Arefiev of UC San Diego (theory) and “High resolution imaging of resonately accelerated electrons under tight focusing” led by Deepak Kumar of ELI-Beamlines, Czech Republic, UT Austin provided the Texas Petawatt Laser staff and a prorated share of the materials and supplies approximately equal to the average of those required for one 5-week experimental campaign. Summaries of these three experiments are provided in this report. Two staff members were hired—Dr. Sandra Bruce at 40% and Dr. Erhard Gaul at 50% time—to support Texas Petawatt Laser maintenance and operations and to plan for the Texas Relativistic Intensity Ultrafast Multi-beam Plasma Facility (TRIUMPF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ice-nucleating particles in precipitation samples from the Texas Panhandle

Ice-nucleating particles (INPs) influence the formation of ice crystals in clouds and many types of precipitation. This study reports unique properties of INPs collected from 42 precipitation samples in the Texas Panhandle region from June 2018 to July 2019. We used a cold stage instrument called the West Texas Cryogenic Refrigerator Applied to Freezing Test system to estimate INP concentrations per unit volume of air (nINP) through immersion freezing in our precipitation samples with our detection capability of >0.006 INP L -1 . A disdrometer was used for two purposes: (1) to characterize the ground-level precipitation type and (2) to measure the precipitation intensity as well as size of precipitating particles at the ground level during each precipitation event. While no clear seasonal variations of n INP values were apparent, the analysis of yearlong ground-level precipitation observation as well as INPs in the precipitation samples showed some INP variations, e.g., the highest and lowest n INP values at -25°C both in the summer for hail-involved severe thunderstorm samples (3.0 to 1130 INP L -1 ), followed by the second lowest at the same temperature from one of our snow samples collected during the winter (3.2 INP L -1 ). Furthermore, we conducted bacteria community analyses using a subset of our precipitation samples to examine the presence of known biological INPs. In parallel, we also performed metagenomics characterization of the bacterial microbiome in suspended ambient dust samples collected at commercial open-lot livestock facilities (cattle feedyards hereafter) in the Texas Panhandle (i.e., the northernmost counties of Texas, also known as “West Texas”) to ascertain whether local cattle feedyards can act as a source of bioaerosol particles and/or INPs found in the precipitation samples. Some key bacterial phyla present in cattle feedyard samples appeared in precipitation samples. However, no known ice nucleation active species were detected in our samples. Overall, our results showed that cumulative n INP in our precipitation samples below -20°C could be high in the samples collected while observing > 10 mm h -1 precipitation with notably large hydrometeor sizes and an implication of cattle feedyard bacteria inclusion.

54 ENVIRONMENTAL SCIENCES↗

Energy and water in the Western and Texas interconnects.

The Department of Energy's Office of Electricity has initiated a $60M program to assist the electric industry in interconnection-level analysis and planning. The objective of this effort is to facilitate the development or strengthening of capabilities in each of the three interconnections serving the lower 48 states of the United States, to prepare analyses of transmission requirements under a broad range of alternative futures and develop long-term interconnection-wide transmission expansion plans. The interconnections are the Western Interconnection, the Eastern Interconnection, and the Texas Interconnection. One element of this program address the support and development of an integrated energy-water Decision Support System (DSS) that will enable planners in the Western and Texas Interconnections to analyze the potential implications of water stress for transmission and resource planning (the Eastern Interconnection is not participating in this element). Specific objectives include: (1) Develop an integrated Energy-Water Decision Support System (DSS) that will enable planners in the Western and Texas Interconnections to analyze the potential implications of water stress for transmission and resource planning. (2) Pursue the formulation and development of the Energy-Water DSS through a strongly collaborative process between members of this proposal team and the Western Electricity Coordinating Council (WECC), Western Governors Association (WGA), the Electric Reliability Council of Texas (ERCOT) and their associated stakeholder teams. (3) Exercise the Energy-Water DSS to investigate water stress implications of the transmission planning scenarios put forward by WECC, WGA, and ERCOT. The goals of this project are: (1) Develop an integrated Energy-Water Decision Support System (DSS) that will enable planners to analyze the potential implications of water stress for transmission and resource planning. (2) Pursue the formulation and development of the Energy-Water DSS through a strongly collaborative process between Western Electricity Coordinating Council, Electric Reliability Council of Texas, Western Governors Association, and Western States Water Council. (3) Exercise the Energy-Water DSS to investigate water transmission planning scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field surveying data of low-cost networked flood sensors in southeast Texas

Floods are common natural disasters worldwide and pose substantial risks to life, property, food production, and natural resources. Effective measures for flood mitigation and warning are essential. Southeast Texas is still at significant risk of flooding, and Lamar University is assisting the region with asset management of a flood sensor network for flooding events. This network provides real-time water stage information. Lamar University developed a survey program to measure elevation and coordinates at each sensor site location to make this data more useful for flood monitoring and mapping. This paper overviews the measurement of the elevation and coordinates of 74 networked flood sensors and various flood stage thresholds at critical points that flood decision-makers can use for reference at each site. In the first phase of this program, these sensors were deployed throughout a 7-county region spanning nearly 6,000 square miles in Southeast Texas. The latitude and longitude of the sensors and their elevations were determined using survey-grade Global Navigation Satellite System (GNSS) technology. Various Continually Operating Reference Stations (CORS) were utilized for post-processing to achieve sub-inch resolution. The flood stage thresholds, water level sensors elevation, and the elevations and positions of other critical surrounding points are viewable to the public through two online repositories and a web-based sensor management dashboard. The data is used to aid with decisions related to road closures or modeling efforts by mitigation decision-makers, emergency managers, and the public, including the Texas Department of Transportation, Houston Transtar, the National Weather Service, and the Sabine River Authority of Texas (SRA).

54 ENVIRONMENTAL SCIENCES↗

Conscientious vaccination exemptions in kindergarten to eighth-grade children across Texas schools from 2012 to 2018: A regression analysis

Background: As conscientious vaccination exemption (CVE) percentages rise across the United States, so does the risk and occurrence of outbreaks of vaccine-preventable diseases such as measles. In the state of Texas, the median CVE percentage across school systems more than doubled between 2012 and 2018. During this period, the proportion of schools surpassing a CVE percentage of 3% rose from 2% to 6% for public schools, 20% to 26% for private schools, and 17% to 22% for charter schools. The aim of this study was to investigate this phenomenon at a fine scale. Methods and findings: Here, we use beta regression models to study the socioeconomic and geographic drivers of CVE trends in Texas. Using annual counts of CVEs at the school system level from the 2012–2013 to the 2017–2018 school year, we identified county-level predictors of median CVE percentage among public, private, and charter schools, the proportion of schools below a high-risk threshold for vaccination coverage, and five-year trends in CVEs. Since the 2012–2013 school year, CVE percentages have increased in 41 out of 46 counties in the top 10 metropolitan areas of Texas. We find that 77.6% of the variation in CVE percentages across metropolitan counties is explained by median income, the proportion of the population that holds a bachelor's degree, the proportion of the population that self-reports as ethnically white, the proportion of the population that is English speaking, and the proportion of the population that is under the age of five years old. Across the 10 top metropolitan areas in Texas, counties vary considerably in the proportion of school systems reporting CVE percentages above 3%. Sixty-six percent of that variation is explained by the proportion of the population that holds a bachelor’s degree and the proportion of the population affiliated with a religious congregation. Three of the largest metropolitan areas—Austin, Dallas–Fort Worth, and Houston—are potential vaccination exemption "hotspots," with over 13% of local school systems above this risk threshold. The major limitations of this study are inconsistent school-system-level CVE reporting during the study period and a lack of geographic and socioeconomic data for individual private schools. Conclusions: In this study, we have identified high-risk communities that are typically obscured in county-level risk assessments and found that public schools, like private schools, are exhibiting predictable increases in vaccination exemption percentages. As public health agencies confront the reemerging threat of measles and other vaccine-preventable diseases, findings such as ours can guide targeted interventions and surveillance within schools, cities, counties, and sociodemographic subgroups.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of Wind/Solar Co-located Generation in Texas

This paper evaluates the opportunity to load co-located wind and solar generation capacity onto a constrained transmission system while engendering only minimal losses. It quantifies the economic and energy opportunities and costs associated with pursuing this strategy in two Texas locations one in west Texas and the other in south Texas. The study builds upon previous work published by the American Solar Energy Society (ASES) which illuminated the potential benefits of negative correlation of wind and solar generation in some locations by quantifying the economic and energy losses which would arise from deployment of solar generation in areas with existing wind generation and constrained transmission capacity. Clean Energy Associates (CEA) obtained and incorporated wind and solar resource data and the Electric Reliability Council of Texas (ERCOT)) load and price data into a model which evaluates varying levels of solar thermal, solar photovoltaic (PV) and wind capacity against an assumed transmission capacity limit at each of the two locations.

14 SOLAR ENERGY↗

The Texas A&M Radioisotope Production and Radiochemistry Program

The main motivation of the project at Texas A&M University was to carry out the production of critically needed radioisotopes used in medicine for diagnostic and therapy, and to establish an academic program in radionuclide production and separation methods. After a lengthy battle with the Texas A&M University Radiation Safety Office, the Texas Department of State Health Services granted us a license for the production of radionuclides in July 2015, allowing us to work in earnest in our project objectives. Experiments began immediately after licensing, and we started the assembly and testing of our target systems. There were four analytical/theoretical projects and two experimental target systems. These were for At-211 production and for Zn- 62/Cu-62 production. The theoretical projects were related to the production of Mo-99/Tc-99m using (a) a subcritical aqueous target system and (b) production of Tc-99m from accelerator-generated Mo-99 utilizing a photon-neutron interaction with enriched Mo-100 targets. The two experimental projects were the development of targetry systems and production of At-211 and Zn-62/Cu-62 generator. The targetry system for At-211 has been tested and production of At-211 is chronic depending of availability of beam time at the cyclotron. The installation and testing of the targetry system for the production of Zn-62/Cu-62 has not been finalized. A description of the systems is described. The academic program in radionuclide production and separation methods was initiated in the fall of 2011; due to the lack of a radiochemistry laboratory, it was suspended. We expect to re-start the academic program at the Texas A&M Institute for Preclinical Studies under the Molecular Imaging Program.

43 PARTICLE ACCELERATORS↗

The Texas A&M Radioisotope Production and Radiochemistry Program

The main motivation of the project at Texas A&M University was to carry out the production of critically needed radioisotopes used in medicine for diagnostics and therapy, and to establish an academic program in radionuclide production and separation methods. After a lengthy battle with the Texas A&M University Radiation Safety Office, the Texas Department of State Health Services granted us a license for the production of radionuclides in July 2015, allowing us to work in earnest in our project objectives. Experiments began immediately after licensing, and we started the assembly and testing of our target systems. There were four analytical/theoretical projects and two experimental target systems. These were for At-211 production and for Zn-62/Cu-62 production. The theoretical projects were related to the production of Mo-99/Tc-99m using a) a subcritical aqueous target system and b) production of Tc-99m from accelerator-generated Mo-99 utilizing a photon-neutron interaction with enriched Mo-100 targets. The two experimental projects were the development of targetry systems and production of At-211 and Zn-62/Cu-62 generator. The targetry system for At-211 has been tested and production of At-211 is chronic depending of availability of beam time at the cyclotron. The installation and testing of the targetry system for the production of Zn-62/Cu-62 has not been finalized. A description of the systems is described. The academic program in radionuclide production and separation methods was initiated in the fall of 2011 and, due to the lack of a radiochemistry laboratory, it was suspended. We expect to re-start the academic program at the Texas A&M Institute for Preclinical Studies under the Molecular Imaging Program.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparison of Measured Direct Normal Irradiance Data to Calculated Using the Disc Model for the Texas Panhandle

It is important that we convert from fossil energy to wind and solar energy. Wind energy is currently the cheapest form of renewable energy, but it is usually a poor match to utility electrical generation in the Great Plains of the United States. Concentrating solar power (CSP) plants are a better match to utility electrical loading, but so far none of these plants have been constructed in the Great Plains. Part of the reason no CSP plants have been constructed is lack of confidence in the solar resource data required (direct normal irradiance or DNI for short). There are several models for converting global solar radiation to DNI, and one of them is the DISC model. Both DNI data and global radiation data were collected at the USDA-Agricultural Research Laboratory at Bushland, Texas, for the years 2009 and 2010. Using the DISC model and measured global radiation data, DNI was calculated and compared to measured DNI data. The total annual solar energy estimated with the model was 5% greater than what was actually measured which was fairly close. However, on a monthly or hourly basis, the percentage difference could be as high as 25%. Analysis of individual months and days resulted in some recommendations for improving the DISC model. Some of the poor correlations between measured solar energy and calculated solar energy using the DISC model implied that another model (DIRINDEX) might be better. Therefore, additional work is planned to investigate the DIRINDEX model with the same data set to see if the correlation improves. This work may potentially lead to the increased use of solar energy for electrical generation, which will decrease the use of fossil fuels and the environmental pollution from fossil fuel power plants. Direct normal irradiance (DNI) is required in the performance estimation of concentrating solar energy systems. The objective of this paper is to compare measured and modeled DNI data for a site in the Texas Panhandle (Bushland, Texas) to determine the accuracy of the model and where improvements might be required. The DNI model used was the Direct Insolation Simulation Code (DISC) which was developed at the National Renewable Energy Lab (NREL) in Boulder, Colorado. We have determined that a portion of the DISC standard deviation error is due to inaccurate modeling of the first and last hour of the day, but other inaccuracies of the DISC model are also discussed. The accuracy of the DISC model improves as the time scale increases (e.g. hour to month to year) due to errors cancelling, and for Bushland, Texas, the DISC model during 2009 predicted 5% more solar energy than the measured DNI.

14 SOLAR ENERGY↗

Simulation of nonlinear propagation of biomedical ultrasound using PZFlex and the KZK Texas code

In biomedical ultrasound nonlinear acoustics can be important in both diagnostic and therapeutic applications and robust simulations tools are needed in the design process but also for day-to-day use such as treatment planning. For most biomedical application the ultrasound sources generate focused sound beams of finite amplitude. The KZK equation is a common model as it accounts for nonlinearity, absorption and paraxial diffraction and there are a number of solvers available, primarily developed by research groups. We compare the predictions of the KZK Texas code (a finite-difference time-domain algorithm) to an FEM-based commercial software, PZFlex. PZFlex solves the continuity equation and momentum conservation equation with a correction for nonlinearity in the equation of state incorporated using an incrementally linear, 2nd order accurate, explicit algorithm in time domain. Nonlinear ultrasound beams from two transducers driven at 1 MHz and 3.3 MHz respectively were simulated by both the KZK Texas code and PZFlex, and the pressure field was also measured by a fibre-optic hydrophone to validate the models. Further simulations were carried out a wide range of frequencies. The comparisons showed good agreement for the fundamental frequency for PZFlex, the KZK Texas code and the experiments. For the harmonic components, the KZK Texas code was in good agreement with measurements but PZFlex underestimated the amplitude: 32% for the 2nd harmonic and 66% for the 3rd harmonic. The underestimation of harmonics by PZFlex was more significant when the fundamental frequency increased. Furthermore non-physical oscillations in the axial profile of harmonics occurred in the PZFlex results when the amplitudes were relatively low. These results suggest that careful benchmarking of nonlinear simulations is important.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Height Above Nearest Drainage (HAND) at Three-Meter Resolution for the State of Texas

URL: https://web.corral.tacc.utexas.edu/nfiedata/pin2flood/texas/ The current National Water Model and its Flood Inundation Mapping (FIM) service use 10-meter Height Above Nearest Drainage (HAND) hydrological terrain. In the Pin2Flood project (https://gis.tdem.texas.gov/portal/apps/storymaps/stories/72f0ec81a7654da688518f486122abed), funded by the Texas Division of Emergency Management (TDEM), ORNL computed the 3-meter HAND and associated synthetic rating curves for the State of Texas, covering 287,535 river streams (1.5km/stream) in 209 HUC8s. This archived dataset includes the HAND raster and the synthetic rating curve table for each of the 209 HUC8s in Texas. It is hosted at the Texas Advanced Computing Center (TACC). This 3-meter HAND is derived from the Fathom 3-meter DEM and NHDPlus V21 using an accelerated version of NOAA's Flood Inundation Mapping version 3 (FIM3, https://github.com/NOAA-OWP/inundation-mapping/tree/dev-fim3)

58 GEOSCIENCES↗

Analysis of Drought Impacts on Electricity Production in the Western and Texas Interconnections of the United States

Electricity generation relies heavily on water resources and their availability. To examine the interdependence of energy and water in the electricity context, the impacts of a severe drought to assess the risk posed by drought to electricity generation within the western and Texas interconnections has been examined. The historical drought patterns in the western United States were analyzed, and the risk posed by drought to electricity generation within the region was evaluated. The results of this effort will be used to develop scenarios for medium- and long-term transmission modeling and planning efforts by the Western Electricity Coordination Council (WECC) and the Electric Reliability Council of Texas (ERCOT). The study was performed in response to a request developed by the Western Governors Association in conjunction with the transmission modeling teams at the participating interconnections. It is part of a U.S. Department of Energy-sponsored, national laboratory-led research effort to develop tools related to the interdependency of energy and water as part of a larger interconnection-wide transmission planning project funded under the American Recovery and Reinvestment Act. This study accomplished three main objectives. It provided a thorough literature review of recent studies of drought and the potential implications for electricity generation. It analyzed historical drought patterns in the western United States and used the results to develop three design drought scenarios. Finally, it quantified the risk to electricity generation for each of eight basins for each of the three drought scenarios and considered the implications for transmission planning. Literature on drought impacts on electricity generation describes a number of examples where hydroelectric generation capacity has been limited because of drought but only a few examples of impact on thermoelectric generation. In all documented cases, shortfalls of generation were met by purchasing power from the market, albeit at higher prices. However, sufficient excess generation and transmission must be available for this strategy to work. Although power purchase was the most commonly discussed drought mitigation strategy, a total of 12 response strategies were identified in the literature, falling into four main categories: electricity supply, electricity demand response, alternative water supplies, and water demand response. Three hydrological drought scenarios were developed based on a literature review and historical data analysis. The literature review helped to identify key drought parameters and data on drought frequency and severity. Historical hydrological drought data were analyzed for the western United States to identify potential drought correlations and estimate drought parameters. The first scenario was a West-wide drought occurring in 1977; it represented a severe drought in five of the eight basins in the study area. A second drought scenario was artificially defined by selecting the conditions from the 10th-percentile drought year for each individual basin; this drought was defined in this way to allow more consistent analysis of risk to electricity generation in each basin. The final scenario was based upon the current low-flow hydro modeling scenario defined by WECC, which uses conditions from the year 2001. These scenarios were then used to quantify the risk to electricity generation in each basin. The risk calculations represent a first-order estimate of the maximum amount of electricity generation that might be lost from both hydroelectric and thermoelectric sources under a worst-case scenario. Even with the conservative methodology used, the majority of basins showed a limited amount of risk under most scenarios. The level of risk in these basins is likely to be amenable to mitigation by known strategies, combined with existing reserve generation and transmission capacity. However, the risks to the Pacific Northwest and Texas Basins require further study. The Pacific Northwest is vulnerable because of its heavy reliance on hydroelectric generation. Texas, conversely, is vulnerable because of its heavy dependence on thermoelectric generation, which relies on surface water for cooling, along with the fact that this basin seems to experience more severe drought events on average. Further modeling analysis will be performed in conjunction with the modeling teams at the participating interconnections (WECC and ERCOT) to explore the transmission implications of the drought scenarios in more detail. Given the first-order nature of this analysis, more detailed study of the potential impacts of drought on electricity generation is recommended. Future analyses should attempt to model the potential impacts of drought at the power-plant level, including potential mitigation strategies; include the effects of drought duration; understand the impacts of climate change; and consider economic impacts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessment of Lesser Prairie-Chicken Lek Density Relative to Landscape Characteristics in Texas

My 2.5-yr Master's project accomplished the objectives of estimating lesser prairie-chicken (LPC) lek density and abundance in the Texas occupied range and modeling anthropogenic and landscape features associated with lek density by flying helicopter lek surveys for 2 field seasons and employing a line-transect distance sampling method. This project was important for several reasons. Firstly, wildlife managers and biologists have traditionally monitored LPC populations with road-based surveys that may result in biased estimates and do not provide access to privately-owned or remote property. From my aerial surveys and distance sampling, I was able to provide accurate density and abundance estimates, as well as new leks and I detected LPCs outside the occupied range. Secondly, recent research has indicated that energy development has the potential to impact LPCs through avoidance of tall structures, increased mortality from raptors perching on transmission lines, disturbance to nesting hens, and habitat loss/fragmentation. Given the potential wind energy development in the Texas Panhandle, spatial models of current anthropogenic and vegetative features (such as transmission lines, roads, and percent native grassland) influencing lek density were needed. This information provided wildlife managers and wind energy developers in Texas with guidelines for how change in landscape features could impact LPCs. Lastly, LPC populations have faced range-wide declines over the last century and they are currently listed as a candidate species under the Endangered Species Act. I was able to provide timely information on LPC populations in Texas that will be used during the listing process.

03 NATURAL GAS↗