Search NASA⌕ Search

SEARCH · Search NASA

Results for “THALLIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effect of hydrophobic ionic liquids aqueous solubility on metal extraction from hydrochloric acid media: Mathematical modelling and trivalent thallium behavior

A mathematical model to explain cations’ solubility of both protic and aprotic ionic liquids in a wide range of hydrochloric acid solutions has been developed. The concept of this model is based on an assumption of the mineral acid extraction into the organic phase, formation of a salt there between an ionic liquid cation and chloride-anion due to ions recombination and partial salt back-extraction. The proposed approach allows estimating corresponding extraction constants. Comparison of calculated and experimentally measured solubility product constants shows that they are in good agreement. It has been determined also that the more the hydrophilicity of the ionic liquids’ cation the more hydrochloric acid is extracted. Furthermore, this model has been utilized to facilitate analysis of thallium transfer into hydrophobic ionic liquids providing insights into the mechanism of metal extraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inelastic dark matter scattering off Thallium cannot save DAMA

We study the compatibility of the observed DAMA modulation signal with inelastic scattering of dark matter (DM) off of the 0.1% Thallium (Tl) dopant in DAMA. In this work we test whether there exist regions of parameter space where the Tl interpretation gives a good fit to the most recent data from DAMA, and whether these regions are compatible with the latest constraints from other direct detection experiments. Previously, Chang et al. in 2010, had proposed the Tl interpretation of the DAMA data, and more recently (in 2019) the DAMA/LIBRA collaboration found regions in parameter space of Tl inelastic scattering that differ by more than 10σ from a no modulation hypothesis. We have expanded upon their work by testing whether the regions of parameter space where inelastic DM-Tl scattering gives a good fit to the most recent DAMA data survive the constraints placed by the lack of a DM signal in XENON1T and CRESST-II. In addition, we have tested how these regions change with the main sources of uncertainty: the Tl quenching factor, which has never been measured directly, and the astrophysical uncertainties in the DM distribution. We conclude that inelastic DM scattering off Tl cannot explain the DAMA data in light of null results from other experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Thallium-208: A Beacon of In Situ Neutron Capture Nucleosynthesis

Here, we demonstrate that the well-known 2.6 MeV gamma-ray emission line from thallium-208 could serve as a real-time indicator of astrophysical heavy element production, with both rapid (r) and intermediate (i) neutron capture processes capable of its synthesis. We consider the r process in a Galactic neutron star merger and show Tl-208 to be detectable from ~12 hours to ~ten days, and again ~1–20 years postevent. Detection of Tl-208 represents the only identified prospect for a direct signal of lead production (implying gold synthesis), arguing for the importance of future MeV telescope missions which aim to detect Galactic events but may also be able to reach some nearby galaxies in the Local Group.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutron Induced Nuclear Reaction Cross Sections for Radiochemistry in the Region of Thallium, Lead, and Bismuth

We have developed a set of modeled nuclear reaction cross sections for use in radiochemical detector diagnostics. Systematics for the input parameters required by the Hauser-Feshbach statistical model developed in the TALYS code system are used to calculate neutron induced nuclear reaction cross sections for targets ranging from Thallium (Z = 81) to Bismuth (Z = 83).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation of thallium-201 scanning for detection of latent coronary artery disease

The use of thallium imaging as a noninvasive method to accurately screen shuttle passengers for latent coronary artery disease was investigated. All radionuclide procedures were performed using an Anger type camera with a high resolution collimator. A minimum of 200,000 counts were collected for each image using a 20% window centered on the 69-83 keV X-rays. For the images obtained following injection with the patient at rest, the testing was begun 10 minutes after injection. Injections of TT during exercise were made at a point near the termination of the treadmill procedure as determined by either the appearance of ST segment changes on the electrocardiogram consistant with subendocardial ischemia, the appearance of angina-like chest pain in the patient or fatigue in the patient which required cessation of the test. The severity of heart disease was based on the medical history, physical exam, exercise electrocardiograms, chest X-rays and the coronary arteriogram.

Johnson, P. C.↗

Engineering and design properties of thallium-doped sodium iodide and selected properties of sodium-doped cesium iodide

Mechanical and thermal properties, not available in the literature but necessary to structural design, using thallium doped sodium iodide and sodium doped cesium iodide were determined to be coefficient of linear thermal expansion, thermal conductivity, thermal shock resistance, heat capacity, elastic constants, ultimate strengths, creep, hardness, susceptibility to subcritical crack growth, and ingot variation of strength. These properties were measured for single and polycrystalline materials at room temperature.

Forrest, K.↗

Mechanical testing of large thallium doped sodium iodide single crystals

The findings of mechanical tests performed on five thallium-doped sodium iodide NaI(Tl) crystals are presented. These crystals are all in the shape of circular flat plates, 20.0 in. in diameter an d0.5 in. thick. The test setup, testing procedure, and the test data are presented. Large crystals exhibit a high degree of material plasticity, as well as a much higher strength than previously anticipated, on the order of 500 psi. Also revealed from the testing is the fact that crystal with a large number of grain boundaries developed less plasticity, and therefore less permanent deformation, than those with fewer grain boundaries.

Lee, H. M.↗

Infrared Attenuation Of Thallium Bromoiodide Fibers

Report presents measurements of attenuation of infrared signals in unclad 381-micrometer-diameter optical fibers of thallium bromoiodide. Measurements of attentuation in TI(Br,I) fibers in wavelength ranges of 1.2 to 3.4 micrometer and 3 to 11 micrometer compare with those of two other groups of researchers.

Goebel, John↗

Thallium Bromide Semiconductor Radiation Materials and Detectors Characterization Studies

Two overarching requirements of crucial importance for the commercial and scientific establishment of semiconductor radiation detectors are: (1) exceptionally high-purity crystals with impurity concentrations less than 1 part-per-billion and (2) single crystals that are relatively free from subgrain boundaries, secondary phases, dislocations, and other electrically-active defects. We investigated the properties of thallium bromide (TlBr) material that affect its performance with the goal of increasing the material's commercial viability for radiation detection applications. For this purpose, we used beamlines at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL), performing Micron-scale X-ray Detector Mapping, White Beam X-ray Diffraction Topography, and Micron-scale X-ray Fluorescence. These characterization methods improve the industry's understanding of TlBr and lead to the production of improved instrumentation. In this particular study we report electro-migration measurements of positive-ion Cu, Ag, and Au impurities in TlBr detectors under electric field strengths typically used for device operation. BNL improved TlBr detectors with an electrode design that corrects the response non-uniformities caused by crystal defects. This design can achieve improved energy resolution while using typical-grade, commercial crystals with relaxed quality requirements, thus reducing the overall cost of detectors. Additional characterization will be necessary to fully understand the structure and performance of TlBr with the ultimate goal to achieve the highest energy resolution. Our findings from past work will be presented along with our recommendations for additional investigation.

36 MATERIALS SCIENCE↗