Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL DEGRADATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermal degradation events as health hazards - Particle vs gas phase effects, mechanistic studies with particles

Experiments on animal subjects are performed to demonstrate that significant lung injury can result from the inhalation of ultrafine TiO2 or Al2O3 particles. The methods include intratracheal instillation of particles, long-term inhalation of particles, and in vitro studies of alveolar macrophages (AMs) to study the production of fibroplast growth factors. The ultrafine TiO2 particles are shown to induce more acute inflammatory reactions than larger particles and lead to persistent chronic effects in the AM-mediated clearance function of particles. The ultrafine particles also induce cytokines more readily, and the data generally suggests that the occurrence of such particles in thermal degradation events makes the fumes highly toxic. The exposure to thermal degradation products is therefore a critical concern for manned space missions with potentially degradable plastic products.

Oberdoerster, G.↗

Heat and Mass Transport from Thermally Degrading Thin Cellulosic Materials in a Microgravity Environment

Attention is given to a theoretical model describing the behavior of a thermally thin cellulosic sheet heated by external thermal radiation in a quiescent microgravity environment. This model describes thermal and oxidative degradation of the sheet and the heat and mass transfer of evolved degradation products from the heated cellulosic surface into the gas phase. Two calculations are carried out: heating without thermal degradation, and heating with thermal degradation of the sheet with endothermic pyrolysis, exothermic thermal oxidative degradation, and highly exothermic char oxidation. It is shown that pyrolysis is the main degradation reaction. Self-sustained smoldering is controlled and severely limited by the reduced oxygen supply.

Kushida, G.↗

Thermal degradation of polytetrafluoroethylene in tube reactors

We have studied the thermal degradation of polytetrafluoroethylene (PTFE) in wet air, dry air and nitrogen gas at temperatures ranging from 310 to 520 C. The principal gas product was tetrafluoroethylene (TFE). The nitrogen experiments yielded only TFE, but experiments in dry and wet air also produced several other minor gas products. The dry air experiments produced the most smoke and the least gas products, with the nitrogen experiments giving no smoke and the highest amounts of gas products. Wet air experiments gave intermediate results for smoke and gas formation. The rate of degradation in wet air showed an apparent activation energy of 103 kca/mol. We also performed FTIR analyses of the smoke particulate, determining that the particulate formed in dry air is different than that formed in wet air.

Mckinnon, J. Thomas↗

Ultrasonic Evaluation of Thermal Degradation in Adhesive Bonds

The critical role played by adhesive bonds in lap joints is well known. A good knowledge of the mechanical properties of adhesive bonds in lap joints is a prerequisite to the design and reliable prediction of the performance of these bonded structures. Furthermore, the lap joint may be subject to high-temperature environments in service. Early detection of the degree of thermal degradation in adhesive bonds is required under these circumstances. A variety of ultrasonic nondestructive evaluation (NDE) techniques can be used to determine the thickness and the elastic moduli of adhesively bonded joints. In this paper we apply a previously developed technique based on the leaky Lamb wave (LLW) experiment to investigate the possibility of characterizing the thermal degradation of adhesive bonds in lap joints. The degradation of the adhesive bonds is determined through comparison between experimental data and theoretical calculations.

degradation lap joints mechanical properties bonde↗

Product specific thermal degradation kinetics of bisphenol F epoxy in inert and oxidative atmospheres using evolved gas analysis–mass spectrometry

Knowledge of the degradation kinetics for polymer materials is important for understanding thermal stability. In this study, evolved gas analysis–mass spectrometry and pyrolysis gas-chromatography-mass spectrometry were evaluated for the potential to deliver additional insight into thermal degradation kinetics of diglycidal ether of bisphenol F (DGEBF) epoxy thermoset under inert and oxidative atmospheres. Degradation products of selected precursor ions were evaluated for their uniqueness to the specific precursor using extracted ion thermographs. Unique mass peaks, solely attributed to a single reaction pathway of a specific product, were determined from extracted ion thermographs and used to determine both activation energy (E a ) and pre-exponential factors for the specific primary reaction pathways. These primary reaction pathways for DGEBF epoxy degradation were then evaluated in the context of transition state theory (TST) and related transition state enthalpies (ΔH ‡ ) and entropies (ΔS ‡ ) of activation to further elucidate the degradation process. It was determined under pyrolysis conditions, as suggested by the E a , the formation of bisphenol F monomer was the rate-limiting step toward the formation of xanthene and phenol. In contrast, under thermo-oxidative conditions, reactions involving oxygen containing species were identified as the rate-limiting step for all observed products based on the large negative ΔS ‡ calculated from TST. This work demonstrates a powerful combination of technique and theory that can provide new insight into the degradation of polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subsurface Spectroscopy of Thermal Degradation Inside an Inert Plastic Bonded Explosive (PBX) Simulant Using Feedback-Assisted Wavefront Shaping

We characterize the subsurface thermal degradation of an inert analog of high-explosive molecular crystals (Eu:Y(acac) 3 (DPEPO)) (EYAD) embedded inside of a plastic bonded explosive simulant using feedback-assisted wavefront shaping-based fluorescence and Raman spectroscopies. This technique utilizes wavefront shaping to focus pump light inside a heterogeneous material onto a target particle, which significantly improves its spectroscopic signature. We find that embedding the EYAD crystals in the heterogeneous polymer results in improved thermal stability, relative to bare crystal measurements, with the crystal remaining fluorescent to >612 K inside of the heterogeneous material, while the bare crystal’s fluorescence is fully quenched by 500 K. We hypothesize that this improvement is due to the polymer restricting the effects of EYAD melting, which occurs at 400 K and is the primary mechanism for spectroscopic changes in the temperature range explored.

Anderson, Benjamin R.↗

A Semi-Detailed Pyrolytic Gas-Phase Kinetic Model for the Volatiles of Polyethylene Thermal Degradation

This work presents a semi-detailed kinetic model to address the pyrolytic gas-phase reactivity of volatiles formed during thermal degradation of polyethylene (PE). The model builds on a validated multi-step condensed-phase model and employs validated lumping approaches. Short-chain compounds are modelled with high detail, while long-chain ones are described by surrogate species representative of diesel-cuts (NC16H32) and waxes (NC30H60). The reactivity of short chains is described through the comprehensive CRECK kinetic model, updated to align C5-C7 olefins based on recent literature experimental data. Due to the lack of experimental data for longer olefins, their reactivity is modeled by analogy to the shorter ones, ensuring an asymptotic behavior with increasing carbon numbers. The semi-detailed model is validated through experimental data on PE pyrolysis, assuming an instantaneous mixing of the inert inlet flow with released volatiles, followed by a segregated plug-flow behavior. Validation across different reactor setups confirms the model’s capability to predict detailed product distributions. Despite minor discrepancies, the proposed model effectively captures experimental trends. Further work will address modelling the reactivity in oxygen-containing environments.

kinetics↗

A Semi-Detailed Pyrolytic Gas-Phase Kinetic Model for the Volatiles of Polyethylene Thermal Degradation

This work presents a semi-detailed kinetic model to address the pyrolytic gas-phase reactivity of volatiles formed during thermal degradation of polyethylene (PE). The model builds on a validated multi-step condensed-phase model and employs validated lumping approaches. Short-chain compounds are modelled with high detail, while long-chain ones are described by surrogate species representative of diesel-cuts (NC16H32) and waxes (NC30H60). The reactivity of short chains is described through the comprehensive CRECK kinetic model, updated to align C5-C7 olefins based on recent literature experimental data. Due to the lack of experimental data for longer olefins, their reactivity is modeled by analogy to the shorter ones, ensuring an asymptotic behavior with increasing carbon numbers. The semi-detailed model is validated through experimental data on PE pyrolysis, assuming an instantaneous mixing of the inert inlet flow with released volatiles, followed by a segregated plug-flow behavior. Validation across different reactor setups confirms the model’s capability to predict detailed product distributions. Despite minor discrepancies, the proposed model effectively captures experimental trends. Further work will address modelling the reactivity in oxygen-containing environments.

kinetics↗

Analytical methods for toxic gases from thermal degradation of polymers

Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

Hsu, M.-T. S.↗

The Potential Interactions of Novec 1230 and Its Thermal Degradation Products with Actinide Metals and Oxides

The environmentally friendly and mainly chemically inert fire suppressant, Novec 1230, is being increasingly used worldwide. However, no published study has considered using Novec 1230 with fires involving radioactive material including actinides; here, therefore, this research note focuses on the possible interactions between Novec 1230 and its thermal degradation products (TDPs) with some actinide compounds (e.g., actinide metal and oxides) commonly present in a radiological facility in the event of a fire. Previous studies of halogenated fire suppressants used in actinide metal fires indicate a possibility for Novec 1230 or its TDPs to chemically interact with actinide compounds at elevated temperatures; however, these reactions are highly unlikely to cause either runaway exothermic reactions or gaseous actinide release.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The behavior of antioxidant irganox 1010 during the thermal degradation of a plastic bonded explosive

The effect of water concentration on the aging behavior of blend components in plastic bonded explosive (PBX) 9501 is investigated when samples were aged up to 24 months under various conditions. Additionally, the blend components studied here are: poly(urethane ester) (Estane®5703) (Estane), nitroplasticizer (NP), and antioxidant Irganox 1010 (Irg1010). The experimental results reveal that NP is prone to thermally degrading and producing H 2 O, NO x , and HNO x species, which are the predominant species to consume Irg1010 during PBX 9501 aging under inert environment. As Irg1010 is completely consumed, Estane degrades through oxidation and NP addition, in addition to well anticipated hydrolysis. The competition among hydrolysis, oxidation, and NP addition results in non-monotonical changes in the molecular weight of Estane over the aging process.

36 MATERIALS SCIENCE↗

Thermal degradation study of silicon carbide threads developed for advanced flexible thermal protection systems

Silicon carbide (SiC) fiber is a material that may be used in advanced thermal protection systems (TPS) for future aerospace vehicles. SiC fiber's mechanical properties depend greatly on the presence or absence of sizing and its microstructure. In this research, silicon dioxide is found to be present on the surface of the fiber. Electron Spectroscopy for Chemical Analysis (ESCA) and Scanning Electron Microscopy (SEM) show that a thin oxide layer (SiO2) exists on the as-received fibers, and the oxide thickness increases when the fibers are exposed to high temperature. ESCA also reveals no evidence of Si-C bonding on the fiber surface on both as-received and heat treated fibers. The silicon oxide layer is thought to signal the decomposition of SiC bonds and may be partially responsible for the degradation in the breaking strength observed at temperatures above 400 C. The variation in electrical resistivity of the fibers with increasing temperature indicates a transition to a higher band gap material at 350 to 600 C. This is consistent with a decomposition of SiC involving silicon oxide formation.

Tran, Huy Kim↗

Reducing Thermal Degradation of Perovskite Solar Cells during Vacuum Lamination by Internal Diffusion Barriers

Current photovoltaic (PV) panels typically contain interconnected solar cells that are vacuum laminated with a polymer encapsulant between two pieces of glass or glass with a polymer backsheet. This packaging approach is ubiquitous in conventional photovoltaic technologies such as silicon and thinfilm solar modules, contributing to thermal management, mechanical reinforcement, and environmental protection to enable the long lifetimes necessary to become financially acceptable. Commercial vacuum lamination processes typically occur at 150 °C to ensure cross-linking and/or glass bonding of the encapsulant to the glass and PV cells. Perovskite solar cells (PSCs) have emerged as a promising next-generation PV technology that is known to degrade under thermal stresses, especially at temperatures above 100 °C. In this study, we determine degradation modes during lamination and engineer internal diffusion barriers within the PSC to withstand the harsh thermal conditions of vacuum lamination. PSCs with self-assembled monolayers at the ITO interface and SnO X layers deposited by atomic layer deposition at the electron extraction side of the device endured vacuum lamination at conditions typical of commercial PV processes (150 °C) without degradation. This work demonstrates that perovskite PV can be integrated into the existing module lamination process, enabling future single- and multijunction modules utilizing perovskite absorbers.

14 SOLAR ENERGY↗