Coupled radiation-thermal Degradation of Polymeric Systems in Nuclear Plants: Data-driven Tools to Predict Damage Accumulation & Early Failures
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Color change of electric cable insulations used in nuclear power plants (NPPs) is a non-destructive, quick and inexpensive technique to measure degradation. Quantification of color change is facilitated by a light booth of CIE D65 illuminant, a commercial camera and open-source software ImageJ with micaToolbox plugin. Yellowness index (YI) and total color difference (?E) are calculated from calibrated photos of a white cross-linked polyethylene (XLPE) and a black ethylene-propylene rubber (EPR) based specimens aged at 110°C, 121°C, 136°C and 150°C after 1~640 days. Using the same setup and software, pixelwise ?E profile is determined for the cross-sectional photo of a white EPR specimen, where heterogeneous aging is detected.
Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages.
Explore the source record for details and available documents.
Dynamic loads applied to metals may lead to brittle or ductile fracture depending on the imposed strain rates, material properties, and specimen geometry. With an increase in the applied velocity, brittle to ductile failure mode transition may also be observed. Furthermore, at high strain rates, ductile fracture may be preceded by shear bands, which are narrow bands of intense plastic deformation, typically accompanied by a significant rise in temperature. Reliable models are needed to predict the response of metals subject to dynamic loads. In particular, capturing the interplay between heat conduction and crack propagation using the phase-field fracture method is still an open research field. To accurately capture the heat transfer physics across crack surfaces, damage models degrading thermal-conductivity are necessary. While isotropic thermal-conductivity degradation models were proposed, they may lead to errors as they are indifferent to crack directionality. In our current work, a new anisotropic approach is proposed in which thermal-conductivity, which depends on the phase-field gradient, is degraded solely across the crack. Here, it is shown that this approach improves the near-field approximation of temperature and heat flux compared with isotropic degradation, when taking the discontinuous crack solutions as reference. Additionally, the anisotropic degradation approach is implemented in a unified dynamic fracture model and a couple of examples demonstrate the viability of this approach.
Upon thermal aging, nitroplasticizer (NP) can thermally degrade and release numerous degradation products depending on aging conditions. In this report, we summarize our recent findings, a library of key degradation products in the NP thermal aging is provided. The library contains 25 identified species with their corresponding MS/MS spectrum and intensity profiles, which are derived from our 44-month thermal aging experiment of NP conducted in air, nitrogen, and water at room temperature (RT), 38, 45, 55, and 64°C. To provide a comprehensive yet simplified overview of NP degradation, we summarized the proposed mechanisms of HONO elimination and decomposition, acid generation, PBNA nitrosation and nitration, acid-catalyzed hydrolyses of NP and polynitrated PBNAs, as well as the formation of NP degradants. As the last part of a series of publications and reports on the investigation of NP degradation mechanisms, this work further unfolds complex chemistry that occurs in the entire aging process of NP.
Abstract Graphite, a robust host for reversible lithium storage, enabled the first commercially viable lithium-ion batteries. However, the thermal degradation pathway and the safety hazards of lithiated graphite remain elusive. Here, solid-electrolyte interphase (SEI) decomposition, lithium leaching, and gas release of the lithiated graphite anode during heating were examined by in situ synchrotron X-ray techniques and in situ mass spectroscopy. The source of flammable gas such as H 2 was identified and quantitively analyzed. Also, the existence of highly reactive residual lithium on the graphite surface was identified at high temperatures. Our results emphasized the critical role of the SEI in anode thermal stability and uncovered the potential safety hazards of the flammable gases and leached lithium. The anode thermal degradation mechanism revealed in the present work will stimulate more efforts in the rational design of anodes to enable safe energy storage.
As nuclear fuel burn-up increases, its thermal conductivity degrades due to the accumulation of defects that lead to increased phonon scattering rates. This results in a rise in the centerline temperature of the fuel rod, whereby heat generation must be decreased to avoid undesired behavior such as fuel melting and extensive fission gas release. Fuel performance codes are utilized to optimize the fuel's operational conditions; while they are based on established physical principles, their empirical nature limits their predictive capabilities. Recently, an effort has been made to develop predictive fuel performance codes for commonly used nuclear fuels, as well as accelerated qualification of advanced nuclear fuels. In this report, we elaborate on the importance of careful analysis of point defects’ impact on thermal conductivity in fuel performance analysis. Further, a model is presented where point defect concentration is estimated based on Rate Theory modeling and used as input to the Klemens-Callaway model to calculate their contribution to the degradation of thermal conductivity in UO 2 under prototypical irradiation conditions. This analysis suggests that point defect concentration is significant at the rim of the fuel pellet and neglecting this leads to underestimation of the centerline temperature, which may have consequences on fission gas behavior.
Outgassing of 3D printed and casted silica-filled silicones was studied using a standard ASTM E-595 procedure and a modified Soreq’s method that allows very sensitive measurements of the outgassing kinetics even at low temperatures, 20 – 50 °C. We studied three different silica-filled silicones, non-porous cased M9787, and 3D printed LL50 and 40P materials. The present report shows that vacuum outgassing products of polysiloxane-based materials include multiple species. In addition to chemisorbed and physisorbed water outgassing, previously studied by TPD, polymer fragments of varying sizes evaporate as well. The chemical composition of the condensable volatile species collected on a Germanium substrate, was analyzed by FTIR. It was shown that all studied materials produce mostly PDMS-based outgassing products that form stable droplet-like structure on the Ge substrate. The highest amount of the condensable volatile species was measured for LL50. Isothermal TGA in nitrogen atmosphere of the LL50 material was compared to the standard vacuum outgassing. The results of TGA showed lower mass loss and higher water regain. The kinetics of the outgassing at relatively low temperatures of 20, 30 and 50 °C was studied using Thermoelectric Quartz Crystal Microbalance (TQCM). The TQCM surface was held at -10 °C to enhance condensation of the outgassed moisture. The analysis presented here, when combined with the extensive previous work on moisture outgassing, provides a better understanding of the aging mechanism of polysiloxane-based materials. In this work we show that outgassing techniques, usually applied for qualification of polymers for space-related applications, may be used as a complementary method to study thermal degradation and aging of silica-based silicones. Our results indicate that the long-term degradation mechanics and thermal degradation products depend primarily on the chemical composition of silicone-based material and only slightly affected by the manufacturing process. Surprisingly, the surface-to-volume ratio of the 3D printed vs. casted/molded materials showed only minor effect on the outgassing kinetic parameters.
Major sources of anthropogenic CO 2 are power generation and transportation industries where researcher continue to explore CO 2 emission mitigation strategies as applied to these CO 2 sources through carbon capture, utilization, and sequestration (CCUS). The most mature CO 2 capture technology is post-combustion carbon capture (PCCC) using aqueous amine solutions/solvents, however solvent degradation and regeneration costs are slowing the widespread adoption of PCCC. Solvent degradation of the aqueous amine solutions is mainly caused from the temperature gradient between the absorber and stripper columns and common flue gas components such as SOx, NOx, and oxygen (O 2 ). The two main classifications of solvent degradation are thermal degradation, occurring when the amine reacts with itself at elevated temperatures and anaerobic conditions and oxidative degradation. Oxidative degradation reactions can occur from oxygen mass transfer and free radical oxidation. Metals, such as iron from the corrosion of steel structures used in industrial applications such as PCCC, can help to catalyze these reactions. Various oxidative degradation studies have shown how O 2 concentrations in flue gas and, to a lesser extent, temperature influence the extent of oxidative degradation. Accurately measuring the O 2 solubility, commonly referred to as dissolved oxygen (DO), in a quick, continuous, and efficient manner in aqueous amine solvents should contribute to determine the effectiveness of mitigation strategies for oxidative degradation. Knowing that commercial PCCC amine solvents contain components beyond water, amine, carbonate species and CO 2 , this investigation was conducted to determine the oxygen solubility changes of common aqueous amines solutions with commonly used and published solvent additives. The impact of carbon loadings with and without the additives was also examined. A commercial dissolved oxygen probe was used to measure the DO concentrations and compared them against standard Winkler Method titration values. The results show that antifoam shows minimal change in [DO]. MBT yielded lower DO values, and NaVO 3 showed a higher DO concentration due to interferences. These results indicate that most common amine solvent additives should be expected to minimally impact oxygen solubility and amine oxidative degradation.
This work studies the evolution of elastic and thermal properties of cementitious composites containing micro-size lightweight fillers after exposure to elevated temperatures (up to 800 °C). A multiscale investigation is carried out to study the thermal degradation of cementitious composite materials at multiple scale levels: at cement past level, the dehydration kinetics of cement hydrates (i.e., C–S–H, CH and aluminate hydrates) and development of microcracks are studied as functions of exposure temperatures. The damage mechanism of the inclusion phases and damages within the interfacial transition zone (ITZ) under elevated temperature are also investigated. In addition, the change of mechanical (i.e., elastic moduli, compressive strengths) and thermal (thermal conductivities) properties are measured as functions of the exposure temperature. Based on the experimental studies, a multiscale thermal degradation model is developed where the thermal degradations of cement paste (including water composition, porosity, and solid phase changes), inclusion phases, and the interfaces are captured through a multiscale sub-stepping homogenization scheme. The thermal degradation model is validated through multiple sets of experimental data. Finally, the influence of key parameters including the particle size distribution of the inclusions, the chemical composition, as well as the effects of ITZ damage are studied.
Quantifying material damage and degradation under reactor conditions enables researchers to make important predictions regarding reactor safety and efficiency. More specifically, thermal property instruments serve as a powerful tool in quantifying the evolution of thermal properties under irradiation, and hence, are necessary in qualifying fuels and materials for reactor use. In addition to providing insight into thermal properties, some instruments may provide a new means of quantifying radiation damage, a challenge in modern nuclear materials research.
A partially degradable polymeric fiber includes a thermally degradable polymeric core and a coating surrounding at least a portion of the core. The thermally degradable polymeric core includes a polymeric matrix including a poly(hydroxy-alkanoate), and a metal selected from the group consisting of an alkali earth metal and a transition metal, in the core polymeric matrix. The concentration of the metal in the polymeric matrix is at least 0.1 wt %. The partially degradable polymeric fiber may be used to form a microvascular system containing one or more microfluidic channels.
Radiolytically and thermally produced long-lived polyenyl C-centered radicals in the nuclear power plants’ insulation cables are detected and measured after more than 45 months of aging since the irradiation and the thermal treatment. Electron Paramagnetic Resonance (EPR) results of the irradiated Cross-linked Polyethylene (XLPE) and Ethylene Propylene Rubber (EthProRu), used as primary insulation materials at Nuclear Power Plants (NPP), clearly demonstrate the presence of polyenyl radicals along with allyl and peroxyl radicals. The yields of these free radicals are dose-rate dependent. EPR results also show the presence of the long-lived polyenyl along with allyl and peroxyl free radicals in the thermally treated XLPE, and EthProRu. These free radicals can cause a major failure in the performance of these cables in NPPs. Besides, the results showed the enhancement in the oxidation reactions due to the migration of copper ions from the conductor to the bulk of the insulation. Further, this study also shows that the oxidation index (OI) and Elongation at Break (EAB) increases and decreases respectively at higher doses and temperatures.
Fentanyl is a synthetic opioid used for managing chronic pain. Due to its higher potency (50–100×) than morphine, fentanyl is also an abused drug. A sensor that could detect illicit fentanyl by identifying its thermally degraded fragments would be helpful to law enforcement. While experimental studies have probed the thermal degradation of fentanyl, little theoretical work has been done to understand the mechanism. Here, we studied the thermal degradation pathways of fentanyl using extensive ab initio molecular dynamics simulations combined with enhanced sampling via multiple-walker metadynamics. We calculated the free energy profile for each bond suggested earlier as a potential degradation point to map the thermodynamic driving forces. In conclusion, we also estimated the forward attempt rate of each bond degradation reaction to gain information about degradation kinetics.
Due to the growing need for Direct Air Capture (DAC) and integrated carbon capture and conversion technologies, CO 2 capture materials that can withstand a wide range of environmental conditions, including fluctuating ambient temperatures and high concentrations of oxidizing agents (i.e., oxygen and moisture), are critically needed. Liquid-like Nanoparticle Organic Hybrid Materials (NOHMs) have been proposed as candidates for DAC and electrolyte additives enabling sustainable energy storage (i.e., integrated CO 2 capture and conversion and flow batteries). Liquid-like NOHMs functionalized with an ionic bond have been shown to display greatly enhanced oxidative thermal stability compared to the untethered polymer. However, these studies were limited in terms of reaction conditions and the detailed mechanisms of the oxidative thermal degradation were not reported. In this work, a kinetic thermal degradation analysis was performed on NOHM-I-HPE and the neat polymer, Jeffamine M2070 (HPE), in both non-oxidative and oxidative conditions. NOHM-I-HPE displayed similar thermal stability to the untethered polymer in a nitrogen environment, but interestingly, the thermal stability of the ionically tethered polymer was significantly enhanced in the presence of air. This observed enhancement of oxidative thermal stability is attributed to the orders of magnitude larger viscosity of the liquid-like NOHMs compared to untethered polymer and the bond stabilization of the ionically tethered polymer in the NOHMs canopy. Further, spectroscopic analyses of the liquid residue revealed that in the presence of oxygen, the degradation of HPE and NOHM-I-HPE occurs through the formation of trace amounts of carbonyls. This study illustrated that NOHMs can serve as functional materials for sustainable energy storage applications because of their excellent oxidative thermal stability.