Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL EMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermal emission of nonspherical particles

The thermal emission of nonspherical particles is studied by applying the fluctuation dissipation theorem to calculate the Stokes' vector source terms in radiative transfer theory. Generally, all the four Stokes' parameters in the source term are nonzero and are proportional to the absorption coefficient in the backward direction. The measurements of active and passive remote sensing are related by showing that within the framework of radiative transfer theory, the emissivity of vertically and horizontally polarized waves can be expressed in terms of the bistatic scattering coefficients in the usual manner. In addition, the emissions of the third and fourth Stokes' parameters are also expressed in terms of bistatic scattering coefficients.

Tsang, L.↗

Broadband and Wide Angle Nonreciprocal Thermal Emission from Weyl Semimetal Structures

Nonreciprocal thermal emission is a cutting-edge technology that enables fundamental control over thermal radiation and has exciting applications in thermal energy harvesting. However, so far one of the foremost challenges is making nonreciprocal emission to operate over a broad wavelength range and for multiple angles. In this work, we solve this outstanding problem by proposing three different types of structures always utilizing only one Weyl semimetal (WSM) thin film combined with one or two additional dielectric or metallic layers and terminated by a metallic substrate. First a tradeoff relationship between the magnitude and bandwidth of the thermal nonreciprocity contrast is established based on the thickness of the WSM film. Then, the bandwidth broadening effect is demonstrated via the insertion of a dielectric spacer layer that can also be fine-tuned by varying its thickness. Finally, further control on the resulting strong nonreciprocal thermal radiation is demonstrated by the addition of a thin metallic layer in the proposed few layer designs. The presented composite structures work for a broad frequency range and multiple emission angles, consisting highly advantageous properties to various nonreciprocal thermal radiation applications. Moreover, the proposed designs do not require any patterning and can be experimentally realized by simple deposition fabrication methods. They are expected to aid in the creation of broadband nonreciprocal thermal emitters that can find applications in new energy harvesting devices.

Andrew Butler↗

Theory for microwave thermal emission from a layer of cloud or rain

Microwave thermal emission from a layer of cloud or rain consisting of spherical particles has been investigated. Scattering effects are studied in great detail with both numerical and analytical approaches. In the absence of ground emission, it is found that scattering induces brightening for optically thin layers and vice versa for optically thick layers. As a function of observation angle, brightening occurs near nadir, while darkening occurs at large angles in the case of small optical thickness. For large optical thickness, darkening occurs at all angles because of backscattering effects. When the layer of cloud or rain is above an air layer and an ocean surface at a higher temperature, it is found that the darkening effect at large optical thickness is much more pronounced. The darkening effect is also larger for vertical polarizations because the ocean emits more vertically polarized components. The effect of thermal emission and molecular absorption by atmospheric gases is also taken into account. Results obtained from analytical formulas under single-scattering assumptions are compared and illustrated.

Tsang, L.↗

Stratospheric constituent distributions from balloon-based limb thermal emission measurements

This research task deals with an analysis of infrared thermal emission observations of the Earth's atmosphere for determination of trace constituent distributions. Infrared limb thermal emission spectra in the 700-2000 cm(exp -1) region were obtained with a liquid nitrogen cooled Michelson interferometer-spectrometer (SIRIS) on a balloon flight launched from Palestine, Texas, at nighttime on September 15-16, 1986. An important objective of this work is to obtain simultaneously measured vertical mixing ratio profiles of O3, H2O, N2O, NO2, N2O5, HNO3 and ClONO2 and compare with measurements made with a variety of techniques by other groups as well as with photochemical model calculations. A portion of the observed spectra obtained by SIRIS from the balloon flight on September 15-16, 1986, has been analyzed with a focus on calculation of the total nighttime odd nitrogen budget from the simultaneously measured profiles of important members of the NO(sub x) family. The measurements permit first direct determination of the nighttime total odd nitrogen concentrations NO(sub y) and the partitioning of the important elements of the NO(sub x) family.

Abbas, Mian M.↗

Sensor Calibration Impacts on Dust Detection Based On MODIS And VIIRS Thermal Emissive Bands

Dust detection using remotely sensed measurements has been one of the challenging problems encountered by atmospheric scientists. MODerate Resolution Imaging Spectroradiometer (MODIS) on the Terra (T)and Aqua (A) platforms have been a versatile sensor for well over 21 and 18 years respectively and have been extremely useful in the retrieval of aerosol information over the entire globe. The MODIS radiances from the Level1B in general are expected to be within 5% accuracy in the reflective wavelengths and within 1% in the thermal emissive wavelengths. In this paper, we evaluate the sensitivity of previously developed dust detection technique based on thermal emissive wavelengths, which correspond to MODIS bands 20, 29, 31, and 32 respectively. The Thermal Emissive Dust Index (TEDI) performed very comparably to the traditional Aerosol Optical Thickness (AOT) retrievals by MODIS reflective channels. Since the MODIS Thermal Emissive Bands (TEB) are well calibrated on-orbit using a BlackBody (BB) source, the calibration of these long wave infrared bands is quite robust. As A-MODIS continues to perform well beyond its designed lifetime of 6 years, the instrument has undergone various levels of degradation during its mission time. As a consequence, it is imperative to check the impacts of calibration on the higher-level retrievals. In this paper, we rigorously analyze the sensitivity of TEDI due to the impact of calibration by the afore-mentioned TEB. The perturbation of the dominant (linear) calibration term demonstrated the following: first, there was a correlation in the sensitivity of the TEDI due to the uncertainty in the linear calibration term. Based on a perturbation in the linear calibration term for all aforementioned bands over a range of ± 5 % yielded the TEDI sensitivity to vary from approximately -3.2 % to about -3.6 %. When considering the uncertainty in each individual band significant changes were observed. The least change was observed for the perturbation in the calibration of band 20 with the TEDI sensitivity and the largest sensitivity in TEDI was observed in the perturbation of band 31 calibration. Thus, in the case of TEDI, noticeable sensitivity due to calibration uncertainty was observed in bands 29, 31, and 32, reiterating the importance of the TEB calibration in these bands. Also, the dust detection scheme based on A-MODIS was successfully transferred to the follow-on sensors such as Suomi (SNPP) and NOAA 20 (N20) VIIRS. The results presented in this paper would be extremely helpful in understanding impacts of calibration on the higher-level products for both current and future missions based on the MODIS heritage. Finally, the work also identifies the importance of radiometric fidelity in maintaining the accuracy of the dust detection. Results presented will show drastic improvement of the Saharan dust detection after the reduction of the electronic crosstalk in the 8.5 μm channel of T-MODIS.

Sriharsha Madhavan↗

Using Lunar Observations to Assess Terra MODIS Thermal Emissive Bands Calibration

MODIS collects data in both the reflected solar and thermal emissive regions using 36 spectral bands. The center wavelengths of these bands cover the3.7 to 14.24 micron region. In addition to using its on-board calibrators (OBC), which include a full aperture solar diffuser (SD) and a blackbody (BB), lunar observations have been scheduled on a regular basis to support both Terra and Aqua MODIS on-orbit calibration and characterization. This paper provides an overview of MODIS lunar observations and their applications for the reflective solar bands (RSB) and thermal emissive bands (TEB) with an emphasis on potential calibration improvements of MODIS band 21 at 3.96 microns. This spectral band has detectors set with low gains to enable fire detection. Methodologies are proposed and examined on the use of lunar observations for the band 21 calibration. Also presented in this paper are preliminary results derived from Terra MODIS lunar observations and remaining challenging issues.

Xiong, Xiaoxiong↗

Thermal Emission Spectroscopy of 1 Ceres: Evidence for Olivine

Thermal emission spectra of the largest asteroid, 1 Ceres, obtained from the Kuiper Airborne Observatory display features that may provide information about its surface mineralogy. The emissivity, obtained by dividing the spectra by a standard thermal model, is compared with emissivity spectra of olivines and phyllosilicates deduced via Kirchoff's law from reflectivity measurements. The spectra provide a fairly good match to fine grained olivines (0 to 5 micrometer size range). The smoothness of the spectrum beyond 18 micrometers is an indication of particles smaller than 50 micrometers. While the abrupt rise in emissivity near 8 micrometers matches many silicates, the distinct emissivity minimum centered near 12.8 micrometers is consistant with iron-poor olivines, but not with phyllosilicates. It suggests the presence of opaques and does not exclude a mixture with organics and fine-grained phyllosilicates.

Witteborn, Fred. C.↗

The linear polarization of lunar thermal emission at 3.1 mm wavelength

Several observations of the distribution of linearly polarized lunar thermal emission were made at a wavelength of 3.1 mm with 4.88 m parabolic reflector from February to March 1971. A shadow corrected rough surface thermal emission model was least squares fitted to the data. Results indicate an effective lunar dielectric constant of 1.34 + or -.08 with surface roughness characterized by a standard deviation of surface slopes of 18 deg + or - 2 deg. A comparison of these results with previously published values at other wavelengths suggests that the effective lunar dielectric constant decreases with decreasing wavelength.

White, T. L.↗

On the relationship between thermal emissivity and the Normalized Difference Vegetation Index for natural surfaces

The spatial variation of both the thermal emissivity (8-14 microns) and Normalized Difference Vegetation Index (NDVI) was measured for a series of natural surfaces within a savanna environment in Botswana. The measurements were performed with an emissivity-box and with a combined red and near-IR radiometer, with spectral bands corresponding to NOAA/AVHRR. It was found that thermal emissivity was highly correlated with NDVI after logarithmic transformation, with a correlation coefficient of R = 0.94. This empirical relationship is of potential use for energy balance studies using thermal IR remote sensing. The relationship was used in combination with AVHRR (GAC), AVHRR (LAC), and Landsat (TM) data to demonstrate and compare the spatial variability of various spatial scales.

Van De Griend, A. A.↗

A Search for Evidence of Non-Thermal Emission from the Supernova Remnants 37A/B

The ADP grant NAG5-9211 entitled 'A Search for Evidence of Non-Thermal Emission from the Supernova Remnants 37 A/B' was not used to support an analysis of the ASCA data for these two remnants because the ASCA mission ended before the remnants were observed. The grant was used to support similar research on two remnants in the Large Magellanic Cloud, N132D and N 103B. An analysis of the Chandra data for these two remnants exhibits some evidence of non-thermal emission from small regions in the remnants. The X-ray spectra for these regions can not be adequately described by a single thermal X-ray emission model. However, if an X-ray synchrotron component is also included, the spectral data can be well described by the model and the values of the fit parameters are consistent with the values expected. These results were presented at the 199th Meeting of the American Astronomical Society. In summary, the grant has enabled us to strengthen the evidence that supernova remnants outside our Galaxy can also accelerate electrons to very-high energies. The results of this analysis will be published soon in the Astrophysical Journal,

Oliversen, R.↗

The Hyperspectral Thermal Emission Spectrometer (HyTES): Preliminary Results

The Hyperspectral Thermal Emission Spectrometer (HyTES) is being developed as part of the risk reduction activities associated with the Hyperspectral Infrared Imager (HyspIRI). HyspIRI is one of the Tier 2 Decadal Survey Missions. HyTES will provide information on how to place the filters on the HyspIRI Thermal Infrared Instrument (TIR) as well as provide antecedent science data. The pushbroom design has 512 spatial pixels over a 50-degree field of view and 256 spectral channels between 7.5 micrometers to 12 micrometers. HyTES includes many key enabling state-of-the-art technologies including a high performance convex diffraction grating, a quantum well infrared photodetector (QWIP) focal plane array, and a compact Dyson-inspired optical design. The Dyson optical design allows for a very compact and optically fast system (F/1.6). It also minimizes cooling requirements due to the fact it has a single monolithic prism-like grating design which allows baffling for stray light suppression. The monolithic configuration eases mechanical tolerancing requirements which are a concern since the complete optical assembly is operated at cryogenic temperatures ((is) approximately 100K). The QWIP allows for optimum spatial and spectral uniformity and provides adequate responsivity or D-star to allow 200mK noise equivalent temperature difference (NEDT) operation across the LWIR passband. Assembly of the system is nearly complete. After completion, alignment results will be presented which show low keystone and smile distortion. This is required to minimize spatial-spectral mixing between adjacent spectral channels and spatial positions. Predictions show the system will have adequate signal to noise for laboratory calibration targets.

Moon Mineralogical Mapper (M3).↗

Hyperspectral Thermal Emission Spectrometer: Engineering Flight Campaign

The Hyperspectral Thermal Emission Spectrometer (HyTES) successfully completed its first set of engineering test flights. HyTES was developed in support of the Hyperspectral Infrared Imager (HyspIRI). HyspIRI is one of the Tier II Decadal Survey missions. HyTES currently provides both high spectral resolution (17 nm) and high spatial resolution (2-5m) data in the thermal infrared (7.5-12 micron) part of the electromagnetic spectrum. HyTES data will be used to help determine the optimum band positions for the HyspIRI Thermal Infrared (TIR) sensor and provide antecedent data for HyspIRI related studies.

HyTES↗