Mathematical model of the film-mounted rocketsonde thermistor
Meteorological rocketsonde film mounted thermistor bead temperature sensor, developing mathematical model for thermometric correction formulas in automatic data processing
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Meteorological rocketsonde film mounted thermistor bead temperature sensor, developing mathematical model for thermometric correction formulas in automatic data processing
Sensing head of thermistor probe is supported in center area of plastic ring which has tabs so that it can be anchored in place by rubber bands or adhesive tapes. Device attaches probes to human subjects practically, reliably, and without affecting characteristics of skin segment being measured.
The selenium immersed, thermistor bolometer, IR detector failed due to spurious and escalating electrical noise outburst as a function of time at elevated temperatures during routine ground based testing in a space simulated environment. Spectrographic analysis of failed bolometers revealed selenium pure zones in the insulating selenium arsenic (Se-As) glass film which surrounds the active sintered Mn, Ni, Co oxide flake. The selenium pure film was identified as a potentially serious failure mechanism. Significant changes were instituted in the manufacturing techniques along with more stringent process controls which eliminated the selenium pure film and successfully produced 22study bolometers.
Scanning radiometers aboard both high-altitude sun-synchronous polar orbit and low altitude equatorial orbit spacecraft have conducted measurements of the earth's long-wave radiation. Attention is presently given to the Earth Radiation Budget Satellite Experiment instruments, which are designed to measure earth radiance with an absolute radiometric error of less than 1 percent. The scanner instruments consists of three broadband radiometer channels employing thermistor bolometers as sensing elements; these radiometers repeatedly scan the earth from limb to limb every 4 sec, generating contiguous pixels on the earth's surface.
The Clouds and the Earth's Radiant Energy System (CERES) spacecraft scanning thermistor bolometer sensors measure earth radiances in the broadband shortwave solar (O.3 - 5.0 micron and total (0.3 to 100 microns) spectral bands as well as in the 8-12 microns water vapor window spectral band. On November 27, 1997, the launch of the Tropical Rainfall Measuring Mission (TRMM) spacecraft placed the first set of CERES sensors into orbit, and 30 days later, the sensors initiated operational measurements of the earth radiance fields. In 1998, the Earth Observing System morning (EOS-AM1) spacecraft will place the second and third sensor sets into orbit. The prelaunch CERES sensors' count conversion coefficients (gains and zero-radiance offsets) were determined in vacuum ground facilities. The gains were tied radiometrically to the International Temperature Scale of 1990 (ITS-90). The gain determinations included the spectral properties (reflectance, transmittance, emittance, etc.) of both the sources and sensors as well as the in-field-of-view (FOV) and out-of-FOV sensor responses. The resulting prelaunch coefficients for the TRMM and EOS-AM1 sensors are presented. Inflight calibration systems and on-orbit calibration approaches are described, which are being used to determine the temporal stabilities of the sensors' gains and offsets from prelaunch calibrations through on-orbit measurements. Analyses of the TRMM prelaunch and on-orbit calibration results indicate that the sensors have retained their ties to ITS-90 at accuracy levels better than /- 0.3% between the 1995 prelaunch and 1997 on-orbit calibrations.
The Clouds and the Earth's Radiant Energy System (CERES) spacecraft scanning thermistor bolometers will measure earth-reflected solar and earth-emmitted,longwave radiances, at the top-of-the-atmosphere. The measurements are performed in the broadband shortwave (0.3-5.0 micron) and longwave (5.0 - >100 micron) spectral regions as well as in the 8 -12 micron water vapor window over geographical footprints as small as 10 kilometers at the nadir. The CERES measurements are designed to improve our knowledge of the earth's natural climate processes, in particular those related to clouds, and man's impact upon climate as indicated by atmospheric temperature. November 1997, the first set of CERES bolometers is scheduled for launch on the Tropical Rainfall Measuring Mission (TRMM) Spacecraft. The CERES bolometers were calibrated radiometrically in a vacuum ground facility using absolute reference sources, tied to the International Temperature Scale of 1990. Accurate bolometer calibrations are dependent upon the derivations of the radiances from the spectral properties [reflectance, transmittance, emittance, etc.] of both the sources and bolometers. In this paper, the overall calibration approaches are discussed for the longwave and shortwave calibrations. The spectral responses for the TRMM bolometer units are presented and applied to the bolometer ground calibrations in order to determine pre-launch calibration gains.
Fourier Transform Spectrometer (FTS) techniques are being used to characterize the relative spectral response, or sensitivity, of scanning thermistor bolometers in the infrared (IR) region (2 - >= 100-micrometers). The bolometers are being used in the Clouds and the Earth's Radiant Energy System (CERES) program. The CERES measurements are designed to provide precise, long term monitoring of the Earth's atmospheric radiation energy budget. The CERES instrument houses three bolometric radiometers, a total wavelength (0.3- >= 150-micrometers) sensor, a shortwave (0.3-5-micrometers) sensor, and an atmospheric window (8-12-micrometers) sensor. Accurate spectral characterization is necessary for determining filtered radiances for longwave radiometric calibrations. The CERES bolometers spectral response's are measured in the TRW FTS Vacuum Chamber Facility (FTS - VCF), which uses a FTS as the source and a cavity pyroelectric trap detector as the reference. The CERES bolometers and the cavity detector are contained in a vacuum chamber, while the FTS source is housed in a GN2 purged chamber. Due to the thermal time constant of the CERES bolometers, the FTS must be operated in a step mode. Data are acquired in 6 IR spectral bands covering the entire longwave IR region. In this paper, the TRW spectral calibration facility design and data measurement techniques are described. Two approaches are presented which convert the total channel FTS data into the final CERES spectral characterizations, producing the same calibration coefficients (within 0.1 percent). The resulting spectral response curves are shown, along with error sources in the two procedures. Finally, the impact of each spectral response curve on CERES data validation will be examined through analysis of filtered radiance values from various typical scene types.
The Clouds and Earth's Radiant Energy System (CERES) missions were designed to measure broadband earth-reflected shortwave solar (0.3 micrometers to less than 5.0 micrometers) and earth-emitted longwave (5.0 micrometers to greater than 100 micrometers) radiances as well as earth-emitted narrow-band radiances in the water vapor window region between 8 micrometers and 12 micrometers. However, the CERES scanning thermistor bolometer sensor zero-radiance offsets were found to vary as much as 1.0 Wm (exp -2) sr (exp -1) with the scan angle measurement geometry due to gravitational forces and systematic electronic noise. To minimize the gravitational effects, the Tropical Rainfall Measuring Mission (TRMM) Spacecraft CERES sensors' offsets were derived on-orbit as functions of scan elevation and azimuth angles from the January 7-8, 1998 radiometric observations of deep cold space, representative of a 3 K blackbody. In this paper, the TRMM/CERES six orbit data base of on-orbit derived offsets is presented and analyzed to define the sampling requirements for the CERES sensors located on the Earth Science Enterprise (ESE) Terra Spacecraft and on the Earth Observing System (EOS) Afternoon (PM-1) Spacecraft, scheduled for launches in 1999 and 2000, respectively. Analyses of the TRMM/CERES shortwave sensor earth radiance measurements indicate that offsets can be determined on-orbit at the plus or minus 0.02 Wm (exp -2) sr (exp -1) precision level. Offset measuring techniques and sampling requirements are discussed for the TRMM and ESE missions. Ground, pre-launch Terra CERES cross-track scan offsets are presented and described which were measured as a function of scan angle.
This is a progress report for the second year of a three year SR&T grant to continue the advancement of NTD-based microcalorimeters. We reported last year that we re-prioritized certain aspects of the statement of work and chose to emphasize issues of array development in the first year rather than wait until year two. Consequently, some of the projects scheduled for the first year were delayed to the second year and we report on those topics here. These include: a) Measurements that map out JFET , thermistor, l/f and feedback resistor noise; b) Investigations that evaluate the limits of the JFET preamplifier circuitry as it pertains to stability at the 2 eV level; The results of a) and b) have led to preliminary measurements that demonstrate 3.08 eV resolution at 6 keV. c) Calculations that can predict the current performance.
Thermistor pressure gauges are characterized by large pressure range, good accuracy and stability, fast measurement, insensitivity to over-pressure, negligible out-gassing, ease in cleaning, and physical and electrical simplicity and ruggedness. A number of excellent papers have been published describing these gauges. However, a detailed account of design procedure and characteristics for a specific gauge would eliminate much of the trial and error encountered in designing a gauge having prescribed range, sensitivity, and stability.
Dynamic plane shear of incompressible viscoelastic material with temperature dependent viscosity determined, using electric transmission line analog
Instrumentation was developed for the high altitude inflatable sphere to measure its skin temperature, acceleration and internal pressure. The sphere without instrumentation has routinely been used over the past 10 years to provide measurements of winds, density, temperature and pressure between 100 Km and 30 Km altitude. With the miniaturized instrumentation package onboard, the system offers the potential for providing meteorological information as well as a better understanding of sphere performance and dynamics during its descent. Of the six launches of instrumented spheres only one provided telemetry data. However, many of the objectives of the program were achieved.
This is a progress report for the first year of a three year Space Research and Technology (SR&T) grant to continue the advancement of neutron transmutation doped (NTD-based) microcalorimeters. We have re-prioritized certain aspects of the statement of work and chose to emphasize issues of array development in the first year rather than wait until year two. Consequently, some of the projects scheduled for the first year were delayed to the second year. Here we report on our progress to: a) Build and test a 1 x 4 element array and to investigate electrical and thermal cross-talk; b) Build a multiplexed 4 channel analog pulse processor; c) Build a digital pulse processor that can accommodate 4 channels with independent triggers; d) Develop a proportional thermal baseline restoration system compatible with the constant voltage mode of microcalorimeter operation.
This is a progress report for the third year of a three year SR&T grant to continue the advancement of NTD-based microcalorimeters. We highlight our progress to date that allowed us to garner an additional three years of funding for this work.
This is a progress report for the third year of a three year SR&T grant to continue the advancement of NTD-based microcalorimeters. We highlight our progress to date that allowed us to garner an additional three years of funding for this work.
Radiosonde measurement errors occur for various reasons: calibration, mishandling of sensors, poor software, radiation, etc. It is important that these errors be found and corrected, or at the least, corrections determined that might be sensibly applied. Radiation errors apparently are the most serious since the lack of radiative equilibrium between the thermistor and its surrounding environment can not be corrected for just a single thermistor without serious intervention. However, errors may be determined using the Accurate Temperature Measuring (ATM) radiosonde. The ATM radiosonde development was initiated in the mid-1980's using three thermistors; five thermistors are presently incorporated in the ATM radiosonde. Test flights at different locations indicated that the radiative effect on the thermistor varies because of the different environment of each location and, can be corrected. When comparisons between different thermistors (radiosondes) are required the ATM is a valuable tool. Investigation of relative humidity measurements is an ongoing issue because of large discrepancies in observed data. The first chilled mirror (SNOW WHITE) radiosonde was flown from Wallops Flight Facility in 1997. Tests and analyses show the chilled mirror radiosonde present very acceptable data up to the altitude of the tropopause and in some measurements, to 100 hPA. Improvement and better interpretation of the measurements are important. Discussion concentrates on new aspects of the ATM radiosonde application and the utility of the chilled mirror radiosonde.
Diamond film temperature and heat-flux sensors are developed using a technology compatible with silicon integrated circuit processing. The technology involves diamond nucleation, patterning, doping, and metallization. Multi-sensor test chips were designed and fabricated to study the thermistor behavior. The minimum feature size (device width) for 1st and 2nd generation chips are 160 and 5 micron, respectively. The p-type diamond thermistors on the 1st generation test chip show temperature and response time ranges of 80-1270 K and 0.29-25 microseconds, respectively. An array of diamond thermistors, acting as heat flux sensors, was successfully fabricated on an oxidized Si rod with a diameter of 1 cm. Some problems were encountered in the patterning of the Pt/Ti ohmic contacts on the rod, due mainly to the surface roughness of the diamond film. The use of thermistors with a minimum width of 5 micron (to improve the spatial resolution of measurement) resulted in lithographic problems related to surface roughness of diamond films. We improved the mean surface roughness from 124 nm to 30 nm by using an ultra high nucleation density of 10(exp 11)/sq cm. To deposit thermistors with such small dimensions on a curved surface, a new 3-D diamond patterning technique is currently under development. This involves writing a diamond seed pattern directly on the curved surface by a computer-controlled nozzle.
A remote temperature sensing system (10) for a scanning mirror (7). The system (10) includes a sensor which detects heat radiated by the mirror and provides a signal in response thereto. In the illustrative implementation, the system (10) includes a thermistor mounted within a housing. The housing is contoured to maximize the receipt of thermal energy thereby. A mounting assembly maintains the thermistor a predetermined nonzero distance from the scanning mirror (7). The invention includes a shroud (12) mounted on the mirror (7) for shielding the thermistor and a support tube connected to the thermistor housing on a first end and to a base on the second end thereof. The support tube is adapted to remain stationary within the shroud as the scanning mirror and the shroud rotate due to the scanning of the mirror. Wires are connected to the thermistor on a first end thereof and are wrapped around the support tube. The wires include a length of electrically conductive material having a resistivity which has a low sensitivity to temperature variations. The sensor output is processed in a conventional manner to provide an output indicative of the temperature of the mirror.