Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Problems encountered in fluctuating flame temperature measurements by thermocouple.

Some thermocouple experiments were carried out in order to obtain sensitivity of thermocouple readings to fluctuations in flames and to determine if the average thermocouple reading was representative of the local volume temperature for fluctuating flames. The thermocouples considered were an exposed junction thermocouple and a fully sheathed thermocouple with comparable time constants. Either the voltage signal or indicated temperature for each test was recorded at sampling rates between 300-4,096 Hz. The trace was then plotted with respect to time or sample number so that time variation in voltage or temperature could be visualized and the average indicated temperature could be determined. For experiments where high sampling rates were used, the signal was analyzed using Fast Fourier Transforms (FFT) to determine the frequencies present in the thermocouple signal. This provided a basic observable as to whether or not the probe was able to follow flame oscillations. To enhance oscillations, for some experiments, the flame was forced. An analysis based on thermocouple time constant, coupled with the transfer function for a sinusoidal input was tested against the experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-intrusive temperature measurements in the vicinity of a thermocouple using synchrotron x-ray fluorescence

A highly spatially resolved synchrotron x-ray fluorescence (XRF) thermometry technique has been used to map temperature fields around a 125 mu m type R thermocouple immersed in a stoichiometric premixed methane flame. The high spatial resolution of the XRF technique allowed temperatures to be measured close to the thermocouple and the impact of the thermocouple on the flame to be assessed. This paper discusses some of the nontrivial challenges of these measurements including the recovery of spectral features from the krypton fluorescent agent that are overlapped by those from the thermocouple metals at locations near the bead surface. The calculated temperatures from 1D premixed flame simulations are in excellent agreement with measurements along the centerline. The results show that the 125 mu m thermocouple induces minimal disturbances to the gas flow and any catalytic effects originating from the bare wires are also inconsequential. Here, the methodology has advanced to a stage where it enables comparisons between the gas temperature in the vicinity of the thermocouple and the actual thermocouple reading.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25

The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.

42 ENGINEERING↗

Assessment of tungsten/rhenium thermocouples with metal-carbon eutectic fixed points up to 1500°C

Four Type A thermocouples and two Type C thermocouples were calibrated at the Au fixed point and Co-C and Pd-C eutectic fixed points. The thermocouples were exposed to 1330 °C for a total of 100 hours. The maximum drift due to the exposure was found to be 4.8 °C. The fixed-point calibration EMF of these thermocouples deviated by less than 0.86% from the temperature specified by the standards ASTM E230-2003 for Type C and GOSTR 8.585-2001 for Type A. The length of one of Type A thermocouples A52 is longer than the others by 150mm. Making use of this provision it was possible to place annealed part of A52 to the temperature gradient part of calibration arrangement every time. Therefore observed aging effect was as low as 0.5 °C compared to the other thermocouples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Multiphysics Code Coupling for Cladding Surface Thermocouples During Two-Phase Heat Transfer from Nuclear Fuel

Transient testing of nuclear fuel involves the evaluation of fuel performance under off-normal and accident conditions and is essential for proving design performance. Instrumentation included in such experiments commonly includes thermocouples attached to the outer surface of the cladding to provide temperature measurements throughout the transient. However, the presence of thermocouples on the cladding surface can alter the local heat transfer characteristics with the surrounding coolant. These localized effects can influence the temperature of the nearby cladding surface and introduce uncertainties in interpreting the thermocouple data. Understanding the impact of thermocouples attached to the outer surface of the cladding is crucial for accurate data interpretation as well as its effect on the thermomechanical behavior of the cladding. This paper presents a novel methodology for simulating the impact of outer cladding thermocouples during transient testing of nuclear fuels. The simulation framework leverages the thermal-hydraulic capabilities of RELAP5-3D coupled to the BISON fuel performance code through the RELAPCouplingApp interface. The methodology is compared against Accident Tolerant Fuel Reactivity Initiated Accident-1-E experiment performed at Idaho National Laboratory. The results reveal approximately 100°C difference between thermocouple-altered temperature and virgin cladding surface. The model overpredicts surface rewet time due to conservative correlations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Boride-based Ceramic Super-high Temperature Thermocouples in Harsh Environments (Final Scientific/Technical Report)

An electromotive force (emf) can be generated along a temperature gradient between the cold end and hot end of a thermoelectric material, termed the Seebeck effect. Based on the Seebeck effect, metallic alloys have been extensively employed to detect temperatures for centuries, named thermocouples. However, commercially available thermocouple alloys suffer from limitations, such as oxidation, chemical degradation, and poor long-term stability under high-temperature harsh environments. This DOE-funded project aimed to develop high-temperature, chemically tolerant thermocouples suitable for operation in extreme environments relevant to semiconducting thermoelectric materials. The research focused on boride-based semiconducting thermoelectric compounds as candidates for next-generation thermocouples with enhanced oxidation resistance, chemical stability, and thermal robustness under conditions representative of charcoal-fired electricity facilities. During the funded years, boride materials were synthesized using an arc-plasma technique under ambient air and argon atmospheres, enabling scalable and cost-effective production compared with conventional boride fabrication methods. The synthesized borides were processed into nanostructured powders, followed by consolidation into dense bulk materials using a spark plasma sintering (SPS) bottom-up approach. Comprehensive characterization was performed, including microstructural analysis, electrical transport measurements, and optical and thermal property evaluation. Both p-type and n-type boride electric legs were fabricated and integrated into boride-based thermocouples. The thermal and irradiation stabilities of the boride nanomaterials and bulk thermoelectric materials were systematically evaluated to assess suitability for long-term operation in harsh environments. Additionally, 12 students were broadly hands-on trained spanning the full research workflow, including word processing and technical editing (e.g., LATEX for manuscript and poster preparation), data collection and analysis (using Python and related libraries and hardware interfaces), sample preparation (including arc-plasma synthesis and spark plasma sintering), and advanced characterization techniques (such as X-ray diffraction, UV–vis spectroscopy, electron microscopy, differential thermal analysis (DTA), and Seebeck coefficient measurements, etc). Overall, this project demonstrated the feasibility of boride-based thermoelectric materials as durable high-temperature thermocouples, providing a promising pathway toward robust temperature sensing technologies aligned with DOE energy infrastructure and extreme-environment monitoring needs.

20 FOSSIL-FUELED POWER PLANTS↗

Enhancements to High Temperature In-Pile Thermocouple Performance

A joint University of Idaho (UI) and Idaho National Laboratory (INL) University Nuclear Research Initiative (UNERI) was to initiated to extend initial INL efforts to develop doped lybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs). The overall objective of this UNERI was to develop recommendations for an optimized thermocouple design for high temperature, long duration, in-pile testing by expanding upon results from initial INL efforts. Tasks to quantify the impact of candidate enhancements, such as alternate alloys, alternate geometries, and alternate thermocouple fabrication techniques, on thermocouple performance were completed at INL's High Temperature Test Laboratory (HTTL), a state of the art facility equipped with specialized equipment and trained staff in the area of high temperature instrumentation development and evaluation. Key results of these evaluations, which are documented in this report, are as follows. The doped molybdenum and Nb-1%Zr, which were proposed in the initial INL HTIR-TC design, were found to retain ductility better than the developmental molybdenum-low niobium alloys and the niobium-low molybdenum alloys evaluated. Hence, the performance and lower cost of the commercially available KW-Mo makes a thermocouple containing KW-Mo and Nb-1%Zr the best option at this time. HTIR-TCs containing larger diameter wires offer the potential to increase HTIR-TC stability and reliability at higher temperatures. HTIR-TC heat treatment temperatures and times should be limited to not more than 100 °C above the proposed operating temperatures and to durations of at least 4 to 5 hours. Preliminary investigations suggest that the performance of swaged and loose assembly HTIR-TC designs is similar. However, the swaged designs are less expensive and easier to construct. In addition to optimizing HTIR-TC performance, This UNERI project provided unique opportunities to several University of Idaho students, allowing them to become familiar with the techniques and equipment used for specialized high temperature instrumentation fabrication and evaluation and to author/coauthor several key conference papers and journal articles.

99 GENERAL AND MISCELLANEOUS↗

Blackbody comparator for thermocouple calibration

MIKES is developing a measurement set-up for calibrating thermocouples in the temperature range 960 °C - 1500 °C. The calibration method is based on direct comparison of thermocouples and radiation thermometers. We have designed a graphite blackbody comparator cell, which is operated in a horizontal single-zone tube furnace. The cell includes two blackbody cavities for radiation temperature measurements. The cavities have openings on opposite sides of the cell, allowing simultaneous measurement with two radiation thermometers. The design of the comparator allows three thermocouples to be calibrated simultaneously. The thermocouples to be calibrated are inserted in thermometer wells around one of the measurement cavities. We characterize the blackbody comparator in terms of repeatability, temperature distribution and emissivity. Finally, we validate the uncertainty analysis by comparing calibration results obtained for type B and S thermocouples to the calibration results reported by Technical Research Institute of Sweden (SP), and MIKES. The agreement in the temperature range 1000 °C - 1500 °C is within 0.90 °C, the average deviation being 0.17 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancements to High Temperature In-Pile Thermocouple Performance

A joint University of Idaho (UI) and Idaho National Laboratory (INL) University Nuclear Research Initiative (UNERI) was to initiated to extend initial INL efforts to develop doped molybdenum/niobium alloy High Temperature Irradiation Resistant Thermocouples (HTIR-TCs). The overall objective of this UNERI was to develop recommendations for an optimized thermocouple design for high temperature, long duration, in-pile testing by expanding upon results from initial INL efforts. Tasks to quantify the impact of candidate enhancements, such as alternate alloys, alternate geometries, and alternate thermocouple fabrication techniques, on thermocouple performance were completed at INL's High Temperature Test Laboratory (HTTL), a state of the art facility equipped with specialized equipment and trained staff in the area of high temperature instrumentation development and evaluation. Key results of these evaluations, which are documented in this report, are as follows. The doped molybdenum and Nb-1%Zr, which were proposed in the initial INL HTIR-TC design, were found to retain ductility better than the developmental molybdenum-low niobium alloys and the niobium-low molybdenum alloys evaluated. Hence, the performance and lower cost of the commercially available KW-Mo makes a thermocouple containing KW-Mo and Nb-1%Zr the best option at this time. HTIR-TCs containing larger diameter wires offer the potential to increase HTIR-TC stability and reliability at higher temperatures. HTIR-TC heat treatment temperatures and times should be limited to not more than 100 C above the proposed operating temperatures and to durations of at least 4 to 5 hours. Preliminary investigations suggest that the performance of swaged and loose assembly HTIR-TC designs is similar. However, the swaged designs are less expensive and easier to construct. In addition to optimizing HTIR-TC performance, This UNERI project provided unique opportunities to several University of Idaho students, allowing them to become familiar with the techniques and equipment used for specialized high temperature instrumentation fabrication and evaluation and to author/coauthor several key conference papers and journal articles.

36 MATERIALS SCIENCE↗

Thermocouple Errors when Mounted on Cylindrical Surfaces in Abnormal Thermal Environments.

Mineral-insulated, metal-sheathed, Type-K thermocouples are used to measure the temperature of various items in high-temperature environments, often exceeding 1000degC (1273 K). The thermocouple wires (chromel and alumel) are protected from the harsh environments by an Inconel sheath and magnesium oxide (MgO) insulation. The sheath and insulation are required for reliable measurements. Due to the sheath and MgO insulation, the temperature registered by the thermocouple is not the temperature of the surface of interest. In some cases, the error incurred is large enough to be of concern because these data are used for model validation, and thus the uncertainties of the data need to be well documented. This report documents the error using 0.062" and 0.040" diameter Inconel sheathed, Type-K thermocouples mounted on cylindrical surfaces (inside of a shroud, outside and inside of a mock test unit). After an initial transient, the thermocouple bias errors typically range only about +-1-2% of the reading in K. After all of the uncertainty sources have been included, the total uncertainty to 95% confidence, for shroud or test unit TCs in abnormal thermal environments, is about +-2% of the reading in K, lower than the +-3% typically used for flat shrouds. Recommendations are provided in Section 6 to facilitate interpretation and use of the results. .

47 OTHER INSTRUMENTATION↗

Sensitivity study on the fin effect of thermocouple mounted on the heated surface under film boiling condition

In the reactivity-initiated accident (RIA) scenario, right after the power burst with the occurrence of departure from nucleate boiling (DNB), the cladding temperature quickly reaches its maximum and is maintained in a steady film boiling regime. Then, under limited heat transfer performance of film boiling, the local cooling effect by the thermocouple wire may not be neglected. A computational model is developed to estimate the local cooling effect of the thermocouple wire mounted on the cladding surface under film boiling condition. The model predicts the temperature profile along the cladding surface as physically expected and is verified against the benchmark problem. Sensitivity studies reveal the significant effects of the thickness of vapor film layer and the diameter of thermocouple on the temperature drop near the thermocouple, for they increase the heat transfer area to the liquid water region. The impact of film boiling heat transfer coefficient, however, is not significant, as the primary heat transfer mechanism near the thermocouple is the heat conduction to the wire. Future study will include the contribution of radiative heat transfer between the cladding surface and the vapor film layer, as well as a transient power history which represents an actual RIA scenario.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Type C Thermocouple Performance at 1500 ºC

Experience with Type C thermocouples operating for long periods in the 1400 to 1600 °C temperature range indicate that significant decalibration occurs, often leading to expensive downtime and material waste. As part of an effort to understand the mechanisms causing drift in these thermocouples, the Idaho National Laboratory conducted a long duration test at 1500 °C containing eight Type C thermocouples. As reported in this paper, results from this long duration test were adversely affected due to oxygen ingress. Nevertheless, results provide important insights about the impact of precipitate formation on thermoelectric response. Post-test examinations indicate that the thermocouple signal was not adversely impacted by the precipitates detected after 1000 hours of heating at 1500 °C and suggest that the signal would not have been adversely impacted by these precipitates for longer durations (if oxygen ingress had not occurred in this test).

47 OTHER INSTRUMENTATION↗

Options Extending the Applicability of High-Temperature Irradiation-Resistant Thermocouples

Several options have been identified that could further enhance the reliability and extend the applicability of High Temperature Irradiation Resistant ThermoCouples (HTIR-TCs) developed by the Idaho National Laboratory (INL) for in-pile testing, allowing their use in temperature applications as high as 1800 °C. The INL and the University of Idaho (UI) investigated these options with the ultimate objective of providing recommendations for alternate thermocouple designs that are optimized for various applications. This paper reports results from INL/UI investigations. Results are reported from tests completed to evaluate the ductility, resolution, transient response, and stability of thermocouples made from specially formulated alloys of molybdenum and niobium. In addition, this paper reports insights gained by comparing the performance of thermocouples fabricated with various heat treatments and alternate geometries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Embedding thermocouples in SS316 with laser powder bed fusion

Recent advances in manufacturing technologies have enabled the fabrication of complex geometries for a wide range of applications, including the energy, aerospace, and civil sectors. The ability to integrate sensors at critical locations within these complex components during the manufacturing process could benefit process monitoring and control by reducing reliance on models to relate surface measurements to internal phenomena. This study investigated embedding thermocouples in a SS316 matrix using laser powder bed fusion. Under optimal processing conditions, embedded thermocouples were characterized post-building, finding good bonding to the matrix with no melt pool penetration to the sensing elements. Futher, the embedded thermocouple performed similarly to an identical non-embedded thermocouple during thermal testing to 500 °C with only a slight difference in response time, which was attributed to the differences in mass and the associated thermal time constants.

image analysis↗

Performance of Custom-Made Very High Temperature Thermocouples in the Advanced Gas Reactor Experiment AGR-5/6/7 During Irradiation [Slides]

Three thermocouple types were incorporated into the AGR-5/6/7 experiment: HTIR-TC, Cambridge Type N, and standard Type N. Prior to selecting these thermocouples, a development and testing program was conducted, and improvements made to the HTIR-TC design. Partly because of the extreme temperatures, the experiment has experienced a relatively high thermocouple failure rate. However, all capsules had at least three surviving thermocouples at the end of four cycles. In the high temperature regions, the HTIR-TCs suffered a lower failure rate compared to Cambridge Type N. One HTIR-TC operated at 1450–1500°C for 85 days without observable drift, which we believe to be the highest sustained temperature ever recorded in a reactor experiment. Three other HTIR-TCs operated at 1250–1400°C, also without observable drift.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long Duration Testing of Type C Thermocouples at 1500 °C

Experience with Type C thermocouples operating for long periods in the 1400 to 1600 °C temperature range indicate that significant decalibration occurs, often leading to expensive downtime and material waste. As part of an effort to understand the mechanisms causing drift in these thermocouples, the Idaho National Laboratory conducted a long duration test at 1500 °C containing eight Type C thermocouples. As report in this document, results from this long duration test were adversely affected due to oxygen ingress. Nevertheless, results provide key insights about the impact of precipitate formation on thermoelectric response. Post-test examinations indicate that thermocouple signal was not adversely impacted by the precipitates detected after 1,000 hours of heating at 1,500 °C and suggest that the signal would not have been adversely impacted by these precipitates for longer durations (if oxygen ingress had not occurred in this test).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermocouple assembly

Disclosed is a thermocouple assembly having a resilient mount; a buffer having a first side and a second side, with the buffer first side connecting with the resilient mount; an insulator having a first side and a second side, with the insulator first side connecting with the buffer second side; and a thermocouple having a first side and a second side, the thermocouple first side connecting with the insulator second side, and the thermocouple second side being configured to be in thermal contact with an object to be measured.

Schwarting, Nelson↗

In situ embedment of type K sheathed thermocouples with directed energy deposition

Advanced nuclear reactor systems require new technologies for heat transfer and system monitoring. Additive manufacturing (AM) offers the design flexibility to allow in-situ sensor embedment through smart manufacturing for real-time monitoring, and performance of these systems. Here, this study focuses on experiments investigating the feasibility of in-situ sensor embedment using directed energy deposition (DED). Type K thermocouples are embedded into 316L stainless steel (SS) samples using two different configurations (e.g., exposed and embedded tips) and two designs (e.g., flush to substrate) within an AM base. Embedded sensor samples are analyzed via in-situ measurements and high-temperature performance validation tests at 350ºC and 900ºC. Temperature performance results at both temperature tests show good agreement with manufacturer specifications proving that these sensors could still capture accurate temperature readings after in-situ embedment during DED processing. An additional optimization experiment was conducted on the exposed tip configuration using a surrogate thermocouple to improve tolerances and the embedment process. Results improved tolerances, lower porosity, smaller gaps between the sensor and base, and better junction contact for the sensor. Although further optimization of this embedment strategy is necessary to improve the structural stability and tolerances within the component, this research strategy provides a proof-of-feasibility for DED embedment with commercial sheathed thermocouples. This research provides early impact on embedment of sensor for multiple materials and complex geometric components..

29 ENERGY PLANNING, POLICY, AND ECONOMY↗