Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOSYPHONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermal Interface Evaluation of Heat Transfer from a Pumped Loop to Titanium-Water Thermosyphons

Titanium-water thermosyphons are being considered for use in the heat rejection system for lunar outpost fission surface power. Key to their use is heat transfer between a closed loop heat source and the heat pipe evaporators. This work describes laboratory testing of several interfaces that were evaluated for their thermal performance characteristics, in the temperature range of 350 to 400 K, utilizing a water closed loop heat source and multiple thermosyphon evaporator geometries. A gas gap calorimeter was used to measure heat flow at steady state. Thermocouples in the closed loop heat source and on the evaporator were used to measure thermal conductance. The interfaces were in two generic categories, those immersed in the water closed loop heat source and those clamped to the water closed loop heat source with differing thermal conductive agents. In general, immersed evaporators showed better overall performance than their clamped counterparts. Selected clamped evaporator geometries offered promise.

Jaworske, Donald A.↗

Thermosyphon Flooding in Reduced Gravity Environments Test Results

The condenser flooding phenomenon associated with gravity aided two-phase thermosyphons was studied using parabolic flights to obtain the desired reduced gravity environment (RGE). The experiment was designed and built to test a total of twelve titanium water thermosyphons in multiple gravity environments with the goal of developing a model that would accurately explain the correlation between gravitational forces and the maximum axial heat transfer limit associated with condenser flooding. Results from laboratory testing and parabolic flights are included in this report as part I of a two part series. The data analysis and correlations are included in a follow on paper.

Gibson, Marc A.↗

Design of a thermosyphon-based thermal valve for controlled high-temperature heat extraction

Conventional concentrated solar power (CSP) is a reliable alternative energy source that uses the sun’s heat to drive a heat engine to produce electrical power. An advantage of CSP is its ability to store thermal energy for use during off-sun hours which is typically done by storing sensible heat in molten salts. Alternatively, thermal energy may be stored as latent heat in a phase-change material (PCM), which stores large quantities of thermal energy in an isothermal process. On-sun, the PCM melts, storing energy. Off-sun, the latent heat is extracted to produce dispatchable electrical power. Here, this paper presents the design of a thermosyphon-based device with sodium working fluid that is able to extract heat from a source as demand requires. A prototype has been designed to transfer 37 kW of thermal energy from a 600°C molten PCM tank to an array of 9% efficient thermoelectric generators (TEGs) to produce 3 kW of usable electrical energy for 5 h. This “thermal valve” design incorporates a funnel to collect condensate and a central shut-off valve to control condensate gravity return to the evaporator. Three circumferential tubes allow vapour transport up to the condenser. Pressure and a thermal resistance models were developed to predict the performance of the thermal valve. The pressure model predicts that the thermal valve will function as designed. The thermal resistance model predicts a 5500× difference in total thermal resistance between “on” and “off” states. The evaporator and condenser walls comprise 96% of the “on” thermal resistance, while the small parasitic heat transfer in the “off” state is primarily (77%) due to radiation losses. Lastly, this simple and effective technology can have a strong impact on the feasibility, scalability, and dispatchability of CSP latent storage. In addition, other industrial and commercial applications can benefit from this thermal valve concept.

14 SOLAR ENERGY↗

Fuzzy model representation of thermosyphon solar water heating system

The aim of this paper is to focus on improvement in prediction accuracy of model for thermosyphon solar water heating (SWH) system. The work employs grey-box modeling approach based on fuzzy system to predict the outlet water temperature of the said system. The prediction performance results are compared with neural network technique, which has been suggested by various researchers in the last one decade. The outlet water temperature prediction by fuzzy modeling technique is analyzed by using 3 models, one with three inputs (inlet water temperature, ambient temperature, solar irradiance), next with two inputs (inlet water temperature, solar irradiance) and last one with single input (solar irradiance/inlet water temperature). An improved prediction performance is observed with three inputs fuzzy model. (author)

14 SOLAR ENERGY↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

The Effect of Nanofluids on the Heat-Transfer Capacity of Miniature Thermosyphons for Electronics Cooling

Stable nanofluids based on DG-100 grade carbon black and carbon nanotubes have been prepared, and their influence on the maximum heat-transfer capacity and thermal resistance of closed-loop two-phase thermosyphons (TPTs) intended for electronics cooling have been studied. A more than twofold increase in the critical heat flux of these TPTs as compared to those filled with water has been obtained along with a sharp decrease in their thermal resistance. It is suggested that this effect is not only due to the high thermal conductivity of the proposed nanofluids, but is also related to the formation of a specific porous structure hindering the appearance of a vapor film and enhancing the boiling process.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Using Thermosyphon Hybrid Cooling System to Optimize Data Center Water Efficiency

Driven by a mission to push the leading edge for data center sustainability, NREL recognized the need to make its data center not just energy efficient, but water efficient, too. So, in 2016, NREL, with partners Johnson Controls and Sandia National Laboratories, deployed an innovative thermosyphon cooler (TSC) as a test bed on the roof of the NREL's Energy Systems Integration Facility (ESIF). In combination with existing evaporative towers, the TSC forms an extremely water-and cost-efficient hybrid cooling system.

97 MATHEMATICS AND COMPUTING↗

Using Thermosyphon Hybrid Cooling System to Optimize Data Center Water Efficiency

Fact sheet describes a Federal Energy Management Program Federal Energy and Water Management Award-winning project that deployed an innovative thermosyphon cooler (TSC) as a test bed on the roof of the National Renewable Energy Laboratory's Energy Systems Integration Facility (ESIF). In combination with existing evaporative towers, the TSC forms an extremely water-and cost-efficient hybrid cooling system.

Data Center↗

NREL Data Center Cuts Water Use in Half With Hybrid Thermosyphon System

In 2016, NREL installed a thermosyphon hybrid cooling system to reduce water use in the already extremely energy efficient data center at the Energy Systems Integration Facility. In this video, NREL Computational Science Center Director Steve Hammond describes how the system has successfully cut onsite water use in half without negative impacts to the data center’s energy efficient operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Thermosyphon Titanium-Water Heat Pipe Design for a Lunar Surface Power System

A long titanium-water thermosyphon heat pipe was designed and tested in support of NASA's lunar surface power system. With a {delta}T of 11.6 C, a prototype has been shown to meet the temperature drop specification of 15 C at 400 W and 400 K. The heat pipe is designed to be embedded in a composite radiator panel to spread waste heat delivered by a circulating pumped loop. The major challenge was managing the fluid inventory to balance the conflicting requirements of power capacity and freeze-thaw tolerance. A unique hybrid wick was designed to achieve the required thermal performance and yet store all the working fluid during idle periods in a freeze-thaw tolerant fashion. A non-condensable gas charge was used to boost power capacity at lower operating temperatures. Eighteen prototypes will be built and tested.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Demonstration of a Thermosyphon Thermal Valve for Controlled Extraction of Stored Solar Thermal Energy

For concentrated solar power (CSP) to be an effective replacement for power generation by fossil fuels, the thermal energy must be stored and then released for when demand exceeds production, such as during off-sun hours. Until now, there has been limited methods to reliably and efficiently release and control the extraction of thermal energy from a material containing stored sensible or latent heat. Due to their isothermal property, phase change materials (PCMs) storing latent heat are an ideal choice for storage, though it has proven challenging to reliably extract and utilize that heat. To solve this problem, the geometry of a thermosyphon was rearranged to create a thermal valve that is able to turn the flow of thermal energy from a PCM 'on' and 'off'. A stainless steel thermal valve using sodium as the working fluid was designed, fabricated, assessed, and found to effectively and selectively extract heat from a 577 degrees C molten aluminum PCM. It is expected that thermal valves will significantly contribute to more widespread implementation of CSP as a stored energy source from distributed generation to utility-scale power production.

14 SOLAR ENERGY↗

Design and Testing for a New Thermosyphon Irradiation Vehicle

The High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL) requires most materials and all fuel experiments to be placed in a pressure containment vessel to ensure that internal contaminants such as fission products cannot be released into the primary coolant. It also requires that all experiments be capable of withstanding various accident conditions (e.g., loss of coolant) without generating vapor bubbles on the surface of the experiment in the primary coolant. These requirements are intended to artificially increase experiment temperatures by introducing a barrier between the experimental materials and the HFIR coolant, and by reducing heat loads to the HFIR primary coolant, thus ensuring that no boiling can occur. A proposed design for materials irradiation would remove these limitations by providing the required primary containment with an internal cooling flow. This would allow for experiments to be irradiated without concern for coolant contamination (e.g., from cladding failure of advanced fuel pins) or for specimen heat load. This report describes a new materials irradiation experiment design that uses a thermosyphon cooling system to allow experimental materials direct access to a liquid coolant. The new design also increases the range of conditions that can be tested in HFIR. This design will provide a unique capability to validate the performance of current and advanced fuels and materials. Because of limited supporting data for this kind of irradiation vehicle, a test program was initiated to obtain operating data that can be used to (1) qualify the vehicle for operation in HFIR and (2) validate computer models used to perform design- and safety-basis calculations. This report also describes the test facility and experimental data, and it provides a comparison of the experimental data to computer simulations. A total of 51 tests have been completed: four tests with pure steam, 12 tests with argon, and 35 tests with helium. A total of 10 tests were performed at subatmospheric pressure, and four of these were performed with pure steam. One test was conducted at a high power of 92.7 kW, six tests were HFIR startups, and two tests were HFIR loss of offsite power (LOOP). Pressures up to 10 MPa, vapor temperatures up to 583 K (310°C), and heater temperatures above 600 K (327°C) have been reached in these tests. Two computer programs, RELAP5-3D and TRACE, have been used to simulate the tests. The TRACE code has shown good agreement with the test data and has been used to model a variety of tests. This experimental facility has been very useful in demonstrating the viability of this new type of irradiation facility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A model of flow in a closed-loop thermosyphon including the Soret effect

This theoretical study addresses the nature of convective motions in a toroidal loop of binary fluid oriented in the vertical plane and heated from below. The boundaries of the loop are impermeable, but gradients of the solute can be set up by Soret diffusion in the direction around the loop. The existence and stability of steady solutions are discussed over the Rayleigh number-Soret coefficient parameter plane. When the Soret coefficient is negative, periodic and chaotic oscillations analogous to those of thermohaline convection are predicted. When the Soret coefficient is positive, relaxation oscillations and low Rayleigh number chaotic motions are found. Both sets of phenomena are predicted to occur for realistic thermosyphon parameters.

Hart, J. E.↗

Thermosyphon Suspension For Growth Of Crystals

Thermosyphon provides gentle convective flow of supersaturated solution that both suspends and contributes material to growing crystal. Apparatus includes heating section, cooling section, and expansion-and-growth chamber in closed flow loop. Intended for growth of protein crystals, so fragile they are easily damaged by high-shear flows produced by pumps.

Nyce, Thomas A.↗

Determination of the dispersion constant in a constrained vapor bubble thermosyphon

The isothermal profiles of the extended meniscus in a quartz cuvette were measured in a gravitational field using an image analyzing interferometer which is based on computer enhanced video microscopy of the naturally occurring interference fringes. The experimental results for heptane and pentane menisci were analyzed using the extended Young Laplace Equation. These isothermal results characterized the interfacial force field in-siru at the start of the heat transfer experiments by quantifying the dispersion constant, which is a function of the liquid-solid system and cleaning procedures. The experimentally obtained values of the disjoining pressure and the dispersion constants were compared to that predicted from the DLP theory and good agreements were obtained. The measurements are critical to the subsequent non-isothermal experiments because one of the major variables in the heat sink capability of the Constrained Vapor Bubble Thermosyphon, CVBT, is the dispersion constant. In all previous studies of micro heat pipes the value of the dispersion constant has been 'estimated'. One of the major advantages of the current glass cell is the ability to view the extended meniscus at all times. Experimentally, we find that the extended Young-Laplace Equation is an excellent model for the force field at the solid-liquid-vapor interfaces.

Dasgupta, Sunando↗

Non-Isothermal Experimental Study of the Constrained Vapor Bubble Thermosyphon

Experimental and theoretical techniques to study non-isothermal transport processes in the constrained vapor bubble thermosyphon (CVBT) were developed using a pentane/quartz system. The transport processes can be evaluated by measuring the liquid film profile, which gives the pressure field, and the temperature field. The axial variation in the capillary pressure was measured using an image-analyzing interferometer that is based on computer-enhanced video microscopy of the naturally occurring interference fringes. Thermoelectric coolers were used to control the temperature level in the condensation region and, therefore, the length of the approximately 'adiabatic' surface region which is a function of the temperature difference between the CVBT surface and the surroundings. High values for the axial thermal conductance in the 'adiabatic' surface region were demonstrated under certain conditions.

Karthikeyan, Muthu↗

Cocurrent loop thermosyphon heat transfer system for sub-ambient evaporative cooling and cool storage

Provided is a cocurrent loop thermosyphon system and method for operation thereof. The system includes a first rising tube having first and second ends; a condenser having first and second ends, with the first end connected to the second end of the first rising tube; a return tube having a first end connected to the second end of the condenser; a second rising tube having a first end connected to a second end of the return tube; a pump that pumps liquid within the second rising tube; and an evaporator having a first end connected to the second end of the second rising tube. The second end of the evaporator outputs vapor created by a change in state of the liquid to the first end of the first rising tube.

Longtin, Jon P.↗