Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Transient Voltage Recorder

A voltage transient recorder can detect lightning induced transient voltages. The recorder detects a lightning induced transient voltage and adjusts input amplifiers to accurately record transient voltage magnitudes. The recorder stores voltage data from numerous monitored channels, or devices. The data is time stamped and can be output in real time, or stored for later retrieval. The transient recorder, in one embodiment, includes an analog-to-digital converter and a voltage threshold detector. When an input voltage exceeds a pre-determined voltage threshold, the recorder stores the incoming voltage magnitude and time of arrival. The recorder also determines if its input amplifier circuits clip the incoming signal or if the incoming signal is too low. If the input data is clipped or too low, the recorder adjusts the gain of the amplifier circuits to accurately acquire subsequent components of the lightning induced transients.

Pedro J Medelius↗

Precise optical pulse timing

This paper evaluates the performance of the maximum likelihood and several sub-optimum arrival time estimators for optical pulses. The performance analysis of a 'sliding window' counter followed by that of a threshold detector is achieved by deriving an expression for the first crossing density of the output of the counter. A sub-optimum arrival time estimator using a threshold rather than a maximum detector is suggested and evaluated by simulation. It appears to provide near optimum performance.

Lee, G.↗

Optimum detection of an optical image on a photoelectric surface

The detection of an optical image in the presence of uniform background light is based on a likelihood ratio formed of the numbers of photoelectrons emitted from small elements of a photoelectric surface onto which the image is focused. When diffraction is negligible and the surface has unit quantum efficiency, this detector is equipollent with the optimum detector of the image forming light. Its performance is compared with that of the threshold detector and that of a detector basing its decisions on the total number of photoelectrons from a finite area of the image. The illuminance of the image is postulated to have a Gaussian spatial distribution. All three detectors exhibit nearly the same reliability.

Helstrom, C. W.↗

Detection and Estimation of an Optical Image by Photon-Counting Techniques

Statistical description of a photoelectric detector is given. The photosensitive surface of the detector is divided into many small areas, and the moment generating function of the photo-counting statistic is derived for large time-bandwidth product. The detection of a specified optical image in the presence of the background light by using the hypothesis test is discussed. The ideal detector based on the likelihood ratio from a set of numbers of photoelectrons ejected from many small areas of the photosensitive surface is studied and compared with the threshold detector and a simple detector which is based on the likelihood ratio by counting the total number of photoelectrons from a finite area of the surface. The intensity of the image is assumed to be Gaussian distributed spatially against the uniformly distributed background light. The numerical approximation by the method of steepest descent is used, and the calculations of the reliabilities for the detectors are carried out by a digital computer.

Wang, Lily Lee↗

Digitally controlled pulse-level discriminator operates over wide voltage range

Low power drain discriminator circuit generates an output pulse when an input pulse exceeds a discrete digitally controlled threshold voltage. The discriminator operates over a wide linear or nonlinear range of threshold levels. It uses several amplifier stages ahead of a fixed-reference threshold detector.

Cancro, C. A.↗

Progress in the measurement of high-energy galactic cosmic ray electrons

Cosmic ray electron measurements by individual threshold detector elements show that about 30 percent of observed electron-like galactic cosmic showers are really proton initiated events. The cosmic electron spectrum at about 10 GeV exhibits a consistent dropoff in intensity leading to a best fit at a power law of spectral index -3.2; a break in the spectrum should occur above 10 GeV.

Silverberg, R. F.↗

Versatile logic system for use in nuclear experiments on scientific satellites.

An improved fast low-power-drain logic system has been developed for use in nuclear experiments on scientific satellites. The basic unit of the system is an AND-NAND gate which has a response in the 10-nsec range, a power drain of 2.0 mw and operates over the temperature range of -40 to +80 C. In addition to providing the AND-NAND logic functions, one or more of the basic units may be connected to yield a monostable pulse generator, a pulse generator proceeding an output pulse at the leading edge of the input pulse, a delay, a threshold detector, and a bistable circuit. The system requires relatively simple circuitry for interfacing at its outputs and inputs.

Cancro, C. A.↗

Optical pulse timing resolution

This correspondence evaluates the performance of the maximum likelihood (ML) and several suboptimal arrival time estimators for optical pulses. The performance analysis of a 'sliding window' counter followed by a threshold detector is achieved by deriving an expression for the first-crossing density of the output of the counter.

Lee, G.↗

The detection and analysis of point processes in biological signals

A pragmatic approach to the detection and analysis of discrete events in biomedical signals is taken. Examples from both clinical and basic research are provided. Introductory sections discuss not only discrete events which are easily extracted from recordings by conventional threshold detectors but also events embedded in other information carrying signals. The primary considerations are factors governing event-time resolution and the effects limits to this resolution have on the subsequent analysis of the underlying process. The analysis portion describes tests for qualifying the records as stationary point processes and procedures for providing meaningful information about the biological signals under investigation. All of these procedures are designed to be implemented on laboratory computers of modest computational capacity.

Anderson, D. J.↗

Absorption of CO2-laser radiation in a hypocycloidal-pinch plasma

Absorption of a 50-J pulsed CO2 laser beam in the plasma produced in a hypocycloidal-pinch apparatus was studied. The apparatus consists of three disk electrodes with a 5-cm hole on the axis. The current sheets are snow-plowed toward the center of the hole to produce a plasma with a density greater than 10 to the 18th/cu cm and a temperature near 1 keV which emits soft X rays for 5 microsec. IR detectors measured the laser radiation incident onto, transmitted through, and scattered from the plasma as functions of time. For a period up to 70 microsec from the onset of X-ray emission, neither transmitted nor scattered laser radiation was observed above the detector threshold of 0.3% of the incident flux. This indicates effective absorption of the laser beam (greater than 99%) and that the particle confinement time extends far beyond the energy confinement time of 5 microsec. Thus, the plasma in this apparatus appears much more amenable to laser heating than that in a theta pinch.

Lee, J. H.↗

High-Frequency Gated Oscillator

New gated oscillator generates bursts of high-frequency sine waves, square waves, and triangular waves in response to control signals. Each burst starts at zero phase, with tight tolerances on signal amplitude and frequency. Frequencies in megahertz range are made possible by using high-speed comparators and high-speed flip-flop as fast-response threshold detector.

Berard, C. A.↗

An improved pulse-height analyzer for energetic particle measurements in the upper atmosphere

An energetic particle spectrometer for measurements in the upper atmosphere by rocket is described. The system has two methods of processing data. One is a staircase generator using threshold detectors; the other is a peak detector. The system incorporates a logarithmic converter for better resolution at low amplitudes and better use of telemetry channels. The circuits are described and calibration procedures are given. Modifications are recommended for high flux environments. Appendices cover sampling error in the peak detector and modifications made to the receiver of the propagation experiment.

Dean, L.↗

Quicker Selection of CCD Images

Microprocessor limits analog-to-digital conversion to image areas of interest. Image region of interest selected in order of brightness by use of threshold detectors and their coordinates stored by microprocessor for tracking.

Salomon, P. M.↗

A preliminary evaluation of a failure detection filter for detecting and identifying control element failures in a transport aircraft

The application of the failure detection filter to the detection and identification of aircraft control element failures was evaluated in a linear digital simulation of the longitudinal dynamics of a B-737 Aircraft. Simulation results show that with a simple correlator and threshold detector used to process the filter residuals, the failure detection performance is seriously degraded by the effects of turbulence.

Bundick, W. T.↗

A Secondary Ion Mass Analyzer for Remote Surface Composition Analysis of the Galilean Moons

Galileo in-situ dust measurements have shown that the Galilean moons are surrounded by tenuous dust clouds formed by collisional ejecta from their icy surfaces, kicked up by impacts of interplanetary micrometeoroids. The majority of the ejecta dust particles have been sensed at altitudes below five between 0.5 and 1 micron, just above the detector threshold, indicating a size distribution decreasing towards bigger particles. their parent bodies. They carry information about the properties of the surface from which they have been kicked up. In particular, these grains may carry organic compounds and other chemicals of biological relevance if they exist on the icy Galilean moons. In-situ analysis of the grain composition with a sophisticated dust analyzer instrument flying on a Jupiter Icy Moons Orbiter can provide important information about geochemical and geophysical processes during the evolutionary histories of these moons which are not accessible with other techniques from an orbiter spacecraft. Thus, spacecraft-based in-situ dust measurements can be used as a diagnostic tool for the analysis of the surface composition of the moons. This way, the in-situ measurements turn into a remote sensing technique by using the dust instrument like a telescope for surface investigation. An instrument capable of very high resolution composition analysis of dust particles is the Cometary Secondary Ion Mass Analyzer (COSIMA). The instrument was originally developed for the Comet Rendezvous and Asteroid Flyby (CRAF) mission and has now been built for ESA'S comet orbiter Rosetta. Dust particles are collected on a target and are later located by an optical microscope camera. A pulsed primary indium ion gun partially ionizes the dust grains. The generated secondary ions are accelerated in an electric field and travel through a reflectron-type time-of-flight ion mass spectrometer.

Krueger, H.↗

Germanium blocked-impurity-band detector arrays - Unpassivated devices with bulk substrates

We have fabricated and characterized six-element monolithic arrays of Ge:Ga blocked-impurity-band detectors, with threshold wavelength 220 microns, peak quantum efficiency 14 percent, detective quantum efficiency 9 percent, dark current 300 e(-)/s, and response uniformity better than 4 percent. The devices are described very well by the standard model of blocked-impurity-band detectors and appear to satisfy many of the requirements of low-background astronomical instruments.

Watson, Dan M.↗

Experiments with the Skylab fire detectors in zero gravity

The Skylab fire detector was evaluated in a zero gravity environment. To conduct the test, small samples of spacecraft materials were ignited in a 5 psi oxygen-rich atmosphere inside a combustion chamber. The chamber free-floated in the cabin of a C-135 aircraft, as the aircraft executed a Keplerian parabola. Up to 10 seconds of zero-gravity combustion were achieved. The Skylab fire-detector tubes viewed the flames from a simulated distance of 3m, and color movies were taken to record the nature of the fire. The experiments established the unique form of zero-gravity fires for a wide range of materials. From the tube-output data, the alarm threshold and detector time constant were verified for the Skylab Fire Detection System.

Linford, R. M. F.↗

Neutron measurements in near-Earth orbit with COMPTEL

The fast neutron flux in near-Earth orbit has been measured with the COMPTEL instrument on the Compton Gamma Ray Observatory (CGRO). For this measurement one of COMPTEL's seven liquid scintillator modules was used as an uncollimated neutron detector with threshold of 12.8 MeV. The measurements cover a range of 4.8 to 15.5 GV in vertical cutoff rigidity and 3 deg to 177 deg in spacecraft geocenter zenith angle. One of the measurements occurred near the minimum of the deepest Forbush decrease ever observed by ground-level neutron monitors. After correction for solar modulation, the total flux is well fitted by separable functions in rigidity and zenith angle. With the spacecraft pointed near the nadir the flux is consistent with balloon measurements of the atmospheric neutron albedo. The flux varies by about a factor of 4 between the extremes of rigidity and a factor of 2 between the extremes of zenith angle. The effect of the spacecraft mass in shielding the detector from the atmospheric neutron albedo is much more important than its role as a source of additional secondary neutrons. The neutron spectral hardness varies little with rigidity or zenith angle and lies in the range spanned by earlier atmospheric neutron albedo measurements.

Morris, D. J.↗