Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME DISCRIMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A new water-based scintillator for efficient Cherenkov and scintillation separation

Neutrinos offer a unique window into the world around us, allowing us to probe otherwise unreachable regions like the interior of stars and the depths of the earth, as well as potentially offering a mechanism for monitoring nuclear activity. Both pure-water and organic liquid scintillators have been used as the detection medium of large-scale neutrino detectors. Organic liquid scintillators offer higher sensitivity at lower energies, which is desirable for many applications, but detection of the Cherenkov radiation required for directional sensitivity is very difficult. A possible solution is to use water-based liquid scintillators (WbLSs), where some fraction of the water is replaced with a micellar solution of the liquid scintillator. This can enhance the detection sensitivity beyond that of pure water, without significantly affecting the ability to leverage the topological Cherenkov signature. Very specific scintillation properties are required to achieve this goal: the scintillation decay time should be significantly slower than that of the Cherenkov emission, so timing-based discrimination of Cherenkov light from scintillation can be applied. At the same time, the light yield should be high enough to enhance the overall sensitivity of the detector, but without losing too much of the Cherenkov light. In this study, we report a new water-based liquid scintillation cocktail based on a 9-methylcarbazole fluorescent dye and a linear alkylbenzene solvent. Here, the proposed composition offers 13.8 ns scintillation decay time and 368 nm emission that matches the desired properties.

Wolszczak, Weronika W. [Lawrence Berkeley National↗

Expanding the Time Dimension of Hyperspectral Infrared Sounding Observations: Designing the NUCAPS-Forecast System

Low Earth orbit (LEO) hyper-spectral infrared (IR) sounders have significant yet untapped potential for characterizing thermodynamic environments of convective initiation and ongoing convection. While LEO soundings are of enormous value to weather forecasters, they cannot provide the temporal resolution needed to resolve the rapidly evolving thermodynamics of the convective environment. A novel methodology was developed to extend snapshots of LEO soundings forward in time up to six hours into the future and has been made available within the NOAA National Weather Service Advanced Weather Interactive Processing System (AWIPS) for testing in a quasi-operational setting. This methodology is based on parcel forward-trajectory calculations from the satellite observing time to recreate future soundings of temperature and moisture at regularly gridded intervals in space and time. The soundings are based on NOAA-Unique Combined Atmospheric Processing System (NUCAPS) retrievals from the Suomi NPP and NOAA-20 satellite platforms to allow for rapid near-real time product processing. Science code was transitioned to operational production in 2019 and the product, NUCAPS-Forecast, was tested at the NOAA Hazardous Weather Testbed Spring Experiment in 2019 and 2021. Forecaster feedback has led to improving the product and processing system to address product limitations and improve its applicability for pre-convective forecasting. This presentation highlights the design of the NUCAPS-Forecast system. Solutions were tested and implemented to remove excess moisture and conjoin forward-trajected parcels into vertical profiles for calculating grids of stability indices. Additionally, use cases that explore the tendencies of derived convective available potential energy (CAPE) and convective inhibition (CIN) were investigated. When evaluated against gridded, hourly accumulated rainfall obtained from the Multi-Radar Multi-Sensor (MRMS) observational data set areas with elevated CAPE (reduced CIN) are shown to be associated with areas of precipitation and increase confidence the LEO soundings advected forward in time physically represent atmospheric processes. These results suggest that adiabatic parcel advection of LEO satellite sounding snapshots forward in time exhibits skill in discriminating locations and times that are more likely to lead to convective initiation. Leveraging trajectory modeling to increase the spatial and temporal resolution of LEO IR sounding observations today demonstrates the value of these observations from the future constellation of JPSS satellites and GeoXO mission.

weather↗

The Role of Time and Frequency in Future Systems

Over the past twenty years, the Global Positioning System (GPS) has revolutionized the performance and the geographical availability of time and frequency discrimination, while at the same time reducing the cost to the individual user. This paper examines the question of what comes next for time and frequency dissemination. The question has two motivations: How can improved performance be achieved in the future, and how can redundant sources of time and frequency be provided to critical systems? A model is developed for time and frequency dissemination based on the time management performed in GPS. Several candidate systems for future time and frequency distribution are identified. One system - SONET telecommunications - is discussed in detail. Performance requirements and hardware implementation are presented.

Stein, Samuel R.↗

Genomic variation across Chinook salmon populations reveals effects of a duplication on migration alleles and supports fine scale structure

Abstract The distribution of ecotypic variation in natural populations is influenced by neutral and adaptive evolutionary forces that are challenging to disentangle. This study provides a high‐resolution portrait of genomic variation in Chinook salmon ( Oncorhynchus tshawytscha ) with emphasis on a region of major effect for ecotypic variation in migration timing. With a filtered data set of ~13 million single nucleotide polymorphisms (SNPs) from low‐coverage whole genome resequencing of 53 populations (3566 barcoded individuals), we contrasted patterns of genomic structure within and among major lineages and examined the extent of a selective sweep at a major effect region underlying migration timing (GREB1L/ROCK1). Neutral variation provided support for fine‐scale structure of populations, while allele frequency variation in GREB1L/ROCK1 was highly correlated with mean return timing for early and late migrating populations within each of the lineages ( r 2 = .58–.95; p < .001). However, the extent of selection within the genomic region controlling migration timing was much narrower in one lineage (interior stream‐type) compared to the other two major lineages, which corresponded to the breadth of phenotypic variation in migration timing observed among lineages. Evidence of a duplicated block within GREB1L/ROCK1 may be responsible for reduced recombination in this portion of the genome and contributes to phenotypic variation within and across lineages. Lastly, SNP positions across GREB1L/ROCK1 were assessed for their utility in discriminating migration timing among lineages, and we recommend multiple markers nearest the duplication to provide highest accuracy in conservation applications such as those that aim to protect early migrating Chinook salmon. These results highlight the need to investigate variation throughout the genome and the effects of structural variants on ecologically relevant phenotypic variation in natural species.

Horn, Rebekah L.↗

Anisotropic neutron response of trans-stilbene and impact on a handheld dual particle imager

Here this manuscript details measurements of the anisotropic light-output response of trans-stilbene, henceforth referred to as stilbene, along the three primary crystal planes and analyzes how this anisotropic response impacts neutron image reconstruction in a handheld dual particle imager (H2DPI). A prototype H2DPI composed of stilbene pillars (6 x 6 x 50 mm 3 ) coupled to silicon photomultipliers was built and is capable of imaging both fast neutrons and gamma rays from kilogram quantities of special nuclear material. Stilbene was chosen as the scintillating medium for the imager because of its pulse shape discrimination capability, time resolution and relatively high light output. A drawback to using stilbene, however, is the anisotropic response. A recoiling proton from a neutron elastic-scattering event in stilbene will yield different amounts of scintillation light depending on the direction of the recoiling proton with respect to the crystal lattice. This manuscript analyzes how this anisotropic response impacts neutron image reconstruction in 4π. The light output in the three primary crystal planes of stilbene were independently measured 6–7 times for proton recoil energies ranging from 0.5–5.0 MeV using a quasi-monoenergetic time-of-flight neutron source. The measured light-output data in the three crystal planes were fit with a semi-empirical function based on Birks’ formula. These fits were used to reconstruct the location of a 252 Cf source in front of the imager (0°, -0.8°), to the left of the imager (-90°, -0.8°) and directly above the imager (0°, 90°) to determine if it is necessary to apply the directionally-dependent response of stilbene to accurately reconstruct source locations. A bootstrapping technique was applied to the measured data sets to produce 1000 images composed of 2000 cone projections for each source location and each measured light-output curve. List-mode maximum likelihood expectation maximization was applied to each image; the highest pixel location and the full width at half maximum (FWHM) were then recorded. The average and standard deviations of these parameters were taken for each set of images. The maximum difference in the average azimuthal pixel location when varying between the appropriate and incorrect light-output curves for the source locations at (0°, -0.8°) and (-90°, -0.8°) were respectively found to be 1.85 ± 1.39° and 2.03 ± 1.78°. All other pixel locations and FWHMs were within a single standard deviation of uncertainty. Taken together, the anisotropic response of stilbene has negligible impact on the neutron image reconstruction capability of the H2DPI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rossi Alpha Measurements – Rapid Organic (n, $\gamma$) Discrimination Detector (RAM-RODD) system capabilities

The Rossi Alpha Measurements–Rapid Organic (n, $\gamma$) Discrimination Detector (RAM-RODD) is an array organic scintillation detectors that has been optimized for use in neutron noise measurements. This report details the capability of the system including the method of energy calibration, pulse shape discrimination, and time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing reconstruction utilising multiple detection subsystems at the Short-Baseline Near Detector experiment

The Short-Baseline Near Detector (SBND) is the near detector of the Short-Baseline Neutrino Program, located only 110 m away from the Booster Neutrino Beam (BNB) target at Fermilab (Illinois, USA). SBND employs key detection technologies: a 112-ton Liquid Argon Time Projection Chamber for ionisation electrons, an advanced Photon Detection System (PDS) made up of photomultiplier tubes and X-ARAPUCAs for scintillation light, and a 4π coverage of Cosmic Ray Taggers (CRTs) for cosmic muons. This setup offers an exceptional energy, spatial and timing reconstruction of neutrino interactions. In this poster, we present ongoing timing reconstruction efforts of the PDS and CRTs, as well as combining complementary information across multiple detection subsystems to improve the timing resolution. This results in nanosecond level timing information that can be leveraged as an analysis tool, including the reconstruction of the BNB substructure to accept or reject signals detected in-between neutrino bunches as well as a timing-based discrimination for cosmic rejection.

Corallo, Annalea [INFN, Ferrara]↗

The elusive tradeoff - Speed vs accuracy in visual discrimination tasks.

Explicit payoffs were used to control pressures for speed and accuracy in experiments seeking tradeoffs for difficult visual discrimination tasks. The experiments involved stimuli on a cathode ray tube display controlled by a PDP-1 computer, with the subjects performing increasingly complex discrimination tasks and their earnings increasing with their performance. Models for discrimination under time pressure are proposed on the basis of the results.

Swensson, R. G.↗

Ultrastable automatic frequency control

Center frequency of wideband AFC circuit drifts only hundredths of percent per day. Since circuit responds only to slow frequency drifts and modulation signal has high-pass characteristics, AFC does not interfere with normal FM operation. Stable oscillator, reset circuit, and pulse generator constitute time-averaging discriminator; digital counter in pulse generator replaces usual monostable multivibrator.

Sabourin, D. J.↗

Satellite laser ranging - Current status and future prospects

The characteristics and capabilities of instruments and operational techniques in the field of satellite laser ranging (SLR) are discussed. Following a brief introduction to the basic concept of SLR, a developmental history of each of the major components of an SLR hardware is given, including the laser transmitter, photomultiplier, discriminator, and time interval unit. The sources of range error in each of the devices are examined, and techniques for reducing error are described. A description of current SLR hardware is summarized using samples of actual satellite data obtained in 1981, which show that orbital fits with a 1.5 single shot rms and normal point rms error of less than 3 mm with 1-6 percent data entering. The development of even more precise measurement techniques in the future with the advent of the Starlette and LAGEOS II SLR system is also discussed.

Degnan, J. J.↗

Spectral imaging applications: Remote sensing, environmental monitoring, medicine, military operations, factory automation and manufacturing

This paper reviews the activities at OKSI related to imaging spectroscopy presenting current and future applications of the technology. The authors discuss the development of several systems including hardware, signal processing, data classification algorithms and benchmarking techniques to determine algorithm performance. Signal processing for each application is tailored by incorporating the phenomenology appropriate to the process, into the algorithms. Pixel signatures are classified using techniques such as principal component analyses, generalized eigenvalue analysis and novel very fast neural network methods. The major hyperspectral imaging systems developed at OKSI include the Intelligent Missile Seeker (IMS) demonstration project for real-time target/decoy discrimination, and the Thermal InfraRed Imaging Spectrometer (TIRIS) for detection and tracking of toxic plumes and gases. In addition, systems for applications in medical photodiagnosis, manufacturing technology, and for crop monitoring are also under development.

National Defense↗

Learning to Identify Airports from Photographs Versus Navigational Maps Presented at Various Orientations

We previously demonstrated: 1) initial learning of navigational maps produced discriminative reaction times (RTs) that were most rapid when the maps were seen in the same orientation as that in which they were initially learned, 2) RTs were significantly reduced with repeated representations, and 3) information learned from the map was not sufficient for all observers to recognize aerial photographs of the same airports. The present study examined the relative effectiveness of initial training on photographs versus maps.

Cohen, Malcolm M.↗