Search NASA⌕ Search

SEARCH · Search NASA

Results for “TMY data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Case for Custom TMYs: Examples Using the NSRDB: Preprint

A typical meteorological year (TMY) essentially represents an hourly compilation of median months constructed using multiyear data sets. Although TMYs are generated from global horizontal irradiance, they are used in photovoltaic (PV) modeling for various plane-of-array (POA) representations. This paper demonstrates that a POA TMY generated with corresponding POA irradiance time-series information produces significantly different results than a POA TMY generated by transposing a TMY data set. In some months, the differences can be more than 3%. These results point to the need for generating TMYs using POA irradiance time series representing the orientation at which PV panels will be deployed.

14 SOLAR ENERGY↗

AutoBEM: A scalable framework for nationwide building energy simulation and retrofit evaluation in the United States

This paper presents AutoBEM, an integrated, automated framework for nationwide building energy modeling and retrofit evaluation in the United States. Unlike prior UBEM platforms that either rely primarily on representative stock sampling or operate at city scale, AutoBEM automates the generation of building-resolved, physics-based EnergyPlus/OpenStudio simulation models at national scale using GIS-derived geometry, prototype-based assumptions, and standardized scalable workflows. Leveraging the Model America dataset and high-performance computing, AutoBEM generates and simulates energy models for 122.9 million buildings, representing 97.8% of the U.S. building stock. These models are being made publicly and freely available as the Model America v1.0 (MAv1) dataset. AutoBEM supports detailed, building-level assessments of energy consumption, CO2 emissions, and post-processed anthropogenic heat emissions (AHE), and evaluates 151 energy conservation measures (ECMs) using localized utility pricing and building characteristics. In addition, AutoBEM incorporates both typical and future climate conditions through integration with Typical Meteorological Year (TMY) and Future TMY (fTMY) weather data derived from IPCC scenarios. In a case study of Phoenix, Arizona, AutoBEM identified several high-efficiency HVAC upgrades and selected envelope measures with short modeled payback periods (1.5 years) for certain building types and standards. Simulations under future climate scenarios (SSP5–RCP8.5) project an 11.3% increase in electricity use and a 32% reduction in natural gas demand by 2100, underscoring the need for climate-adaptive retrofit planning. By enabling reproducible, bottom-up, and location-specific analysis at scale, AutoBEM provides a step toward a national digital twin of the built environment and supports data-driven screening and planning for decarbonization, resilience, and energy equity.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Using Meteorological Data to Evaluate Worldwide PV Degradation Rates

Here we automate the process to enable the creation of world maps for specific PV durability metrics. The end goal is to create a tool for the creation of world maps predicting the sensitivity of modules to degradation to inform the development and utilization of module testing standards and to provide information to module designers. TMY (Typical Meteorological Year) Data was aggregated from sites around the world to render insight into factors contributing to the degradation of solar modules. The focus of aggregating data was to create a single dataset to work with utilizing Solar Irradiance values combined with Ambient Temperature, Relative Humidity, Wind Speed and Dew-Point Temperature.

14 SOLAR ENERGY↗

Stability of Molten Core Materials

The purpose of this report is to document a literature and data search for data and information pertaining to the stability of nuclear reactor molten core materials. This includes data and analysis from TMI-2 fuel and INL’s LOFT (Loss of Fluid Test) reactor project and other sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimation of Tropical Cyclone Intensity in the North Atlantic and Northeastern Pacific Basins Using TRMM Satellite Passive Microwave Observations

Here, a statistical passive microwave intensity estimation (PMW-IE) algorithm for estimating the intensity of tropical cyclones (TCs) in the North Atlantic and northeastern and central Pacific basins is developed and tested. The algorithm is derived from Tropical Rainfall Measuring Mission (TRMM) Microwave Imager (TMI) 85-GHz brightness temperatures and near-surface rain-rate retrievals to provide objective estimates of current maximum sustained surface winds (Vmax) and 6-h future Vmax of TCs. The full record of TRMM data (1998–2013) including 2326 TMI overpasses of 503 TCs is separated into dependent samples (1998–2010) for model development and independent samples (2011–13) for model verification. The best track intensities are used as dependent variables in a stepwise multiple-regression approach. Separately for each basin, three regression models are derived using selected 1) 85-GHz-only variables, 2) rain-rate-only variables, and 3) combined 85-GHz and rain variables. The algorithms are assessed using independent samples and those with contemporaneous aircraft-reconnaissance measurements. Rain-only and combined models perform better than the 85-GHz-only model. Lower errors are found for estimating the 6-h future Vmax than estimating the current Vmax using all three models. This implies that it is optimal to use passive-microwave-retrieved rain variables observed a few hours earlier to estimate TC intensity. The MAE (RMSE) of 6-h future Vmax is 9 (12) kt (1 kt ≈ 0.51 m s -1 ) when testing the combined models with ATL and EPA independent samples. Aircraft-reconnaissance-based independent samples yields a MAE of 9.6 kt and RMSE of 12.6 kt for estimating 6-h future Vmax.

58 GEOSCIENCES↗

Quantifying Interannual Variability for Photovoltaic Systems in PVWatts

The National Renewable Energy Laboratory's (NREL's) PVWatts is a relatively simple tool used by industry and individuals alike to easily estimate the amount of energy a photovoltaic (PV) system will produce throughout the course of a typical year. PVWatts Version 5 has previously been shown to be able to reasonably represent an operating system's output when provided with concurrent weather data, however this type of data is not available when estimating system output during future time frames. For this purpose PVWatts uses weather data from typical meteorological year (TMY) datasets which are available on the NREL website. The TMY files represent a statistically 'typical' year which by definition excludes anomalous weather patterns and as a result may not provide sufficient quantification of project risk to the financial community. It was therefore desired to quantify the interannual variability associated with TMY files in order to improve the understanding of risk associated with these projects. To begin to understand the interannual variability of a PV project, we simulated two archetypal PV system designs, which are common in the PV industry, in PVWatts using the NSRDB's 1961-1990 historical dataset. This dataset contains measured hourly weather data and spans the thirty years from 1961-1990 for 239 locations in the United States. To note, this historical dataset was used to compose the TMY2 dataset. Using the results of these simulations we computed several statistical metrics which may be of interest to the financial community and normalized the results with respect to the TMY energy prediction at each location, so that these results could be easily translated to similar systems. This report briefly describes the simulation process used and the statistical methodology employed for this project, but otherwise focuses mainly on a sample of our results. A short discussion of these results is also provided. It is our hope that this quantification of the interannual variability of PV systems will provide a starting point for variability considerations in future PV system designs and investigations. however this type of data is not available when estimating system output during future time frames.

14 SOLAR ENERGY↗

Revisiting Insights from Three Mile Island Unit 2 Postaccident Examinations and Evaluations in View of the Fukushima Daiichi Accident

The Three Mile Island Unit 2 (TMI-2) accident, which occurred on March 28, 1979, led industry and regulators to enhance strategies to protect against severe accidents in commercial nuclear power plants. Investigations in the years after the accident concluded that at least 45% of the core had melted and that nearly 19 tonnes of the core material had relocated to the lower head. Postaccident examinations indicate that about half of that material formed a solid layer near the lower head and above it was a layer of fragmented rubble. As discussed in this paper, numerous insights related to pressurized water reactor accident progression were gained from postaccident evaluations of debris, reactor pressure vessel (RPV) specimens, and nozzles taken from the RPV. In addition, information gleaned from TMI-2 specimen evaluations and available data from plant instrumentation were used to improve severe accident simulation models that form the technical basis for reactor safety evaluations. Finally, the TMI-2 accident led the nuclear community to dedicate considerable effort toward understanding severe accident phenomenology as well as the potential for containment failure. Because available data suggest that significant amounts of fuel heated to temperatures near melting, the events at Fukushima Daiichi Units 1, 2, and 3 offer an unexpected opportunity to gain similar understanding about boiling water reactor accident progression. To increase the international benefit from such an endeavor, we recommend that an international effort be initiated to (a) prioritize data needs; (b) identify techniques, samples, and sample evaluations needed to address each information need; and (c) help finance acquisition of the required data and conduct of the analyses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States

Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and residential building stock. The End-Use Load Profiles project website includes links to data viewers for this new dataset. For documentation of dataset validation, model calibration, and uncertainty quantification, see Wilson et al. (2022). These data were first created around 2012 as a byproduct of various analyses of solar photovoltaics and solar water heating (see references below for are two examples). This dataset contains several errors and limitations. It is recommended that users of this dataset transition to the updated version of the dataset posted in the resources. This dataset contains weather data, commercial load profile data, and residential load profile data. Weather The Typical Meteorological Year 3 (TMY3) provides one year of hourly data for around 1,000 locations. The TMY weather represents 30-year normals, which are typical weather conditions over a 30-year period. Commercial The commercial load profiles included are the 16 ASHRAE 90.1-2004 DOE Commercial Prototype Models simulated in all TMY3 locations, with building insulation levels changing based on ASHRAE 90.1-2004 requirements in each climate zone. The folder names within each resource represent the weather station location of the profiles, whereas the file names represent the building type and the representative city for the ASHRAE climate zone that was used to determine code compliance insulation levels. As indicated by the file names, all building models represent construction that complied with the ASHRAE 90.1-2004 building energy code requirements. No older or newer vintages of buildings are represented. Residential The BASE residential load profiles are five EnergyPlus models (one per climate region) representing 2009 IECC construction single-family detached homes simulated in all TMY3 locations. No older or newer vintages of buildings are represented. Each of the five climate regions include only one heating fuel type; electric heating is only found in the Hot-Humid climate. Air conditioning is not found in the Marine climate region. One major issue with the residential profiles is that for each of the five climate zones, certain location-specific algorithms from one city were applied to entire climate zones. For example, in the Hot-Humid files, the heating season calculated for Tampa, FL (December 1 - March 31) was unknowingly applied to all other locations in the Hot-Humid zone, which restricts heating operation outside of those days (for example, heating is disabled in Dallas, TX during cold weather in November). This causes the heating energy to be artificially low in colder parts of that climate zone, and conversely the cooling season restriction leads to artificially low cooling energy use in hotter parts of each climate zone. Additionally, the ground temperatures for the representative city were used across the entire climate zone. This affects water heating energy use (because inlet cold water temperature depends on ground temperature) and heating/cooling energy use (because of ground heat transfer through foundation walls and floors). Representative cities were Tampa, FL (Hot-Humid), El Paso, TX (Mixed-Dry/Hot-Dry), Memphis, TN (Mixed-Humid), Arcata, CA (Marine), and Billings, MT (Cold/Very-Cold). The residential dataset includes a HIGH building load profile that was intended to provide a rough approximation of older home vintages, but it combines poor thermal insulation with larger house size, tighter thermostat setpoints, and less efficient HVAC equipment. Conversely, the LOW building combines excellent thermal insulation with smaller house size, wider thermostat setpoints, and more efficient HVAC equipment. However, it is not known how well these ...

Array↗

Evaluation of a Method for Remote Detection of Fuel Relocation Outside the Original Core Volumes of Fukushima Reactor Units 1-3

This paper presents the results of a study to evaluate the feasibility of remotely detecting and quantifying fuel relocation from the core to the lower head, and to regions outside the reactor vessel primary containment of the Fukushima 1-3 reactors. The goals of this study were to determine measurement conditions and requirements, and to perform initial radiation transport sensitivity analyses for several potential measurement locations inside the reactor building. The radiation transport sensitivity analyses were performed based on reactor design information for boiling water reactors (BWRs) similar to the Fukushima reactors, ORIGEN2 analyses of 3-cycle BWR fuel inventories, and data on previously molten fuel characteristics from TMI- 2. A 100 kg mass of previously molten fuel material located on the lower head of the reactor vessel was chosen as a fuel interrogation sensitivity target. Two measurement locations were chosen for the transport analyses, one inside the drywell and one outside the concrete biological shield surrounding the drywell. Results of these initial radiation transport analyses indicate that the 100 kg of previously molten fuel material may be detectable at the measurement location inside the drywell, but that it is highly unlikely that any amount of fuel material inside the RPV will be detectable from a location outside the concrete biological shield surrounding the drywell. Three additional fuel relocation scenarios were also analyzed to assess detection sensitivity for varying amount of relocated material in the lower head of the reactor vessel, in the control rods perpendicular to the detector system, and on the lower head of the drywell. Results of these analyses along with an assessment of background radiation effects and a discussion of measurement issues, such as the detector/collimator design, are included in the paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TU-FG-BRB-03: Basis Vector Model Based Method for Proton Stopping Power Estimation From Experimental Dual Energy CT Data

Purpose: This work aims at reducing the uncertainty in proton stopping power (SP) estimation by a novel combination of a linear, separable basis vector model (BVM) for stopping power calculation (Med Phys 43:600) and a statistical, model-based dual-energy CT (DECT) image reconstruction algorithm (TMI 35:685). The method was applied to experimental data. Methods: BVM assumes the photon attenuation coefficients, electron densities, and mean excitation energies (I-values) of unknown materials can be approximated by a combination of the corresponding quantities of two reference materials. The DECT projection data for a phantom with 5 different known materials was collected on a Philips Brilliance scanner using two scans at 90 kVp and 140 kVp. The line integral alternating minimization (LIAM) algorithm was used to recover the two BVM coefficient images using the measured source spectra. The proton stopping powers are then estimated from the Bethe-Bloch equation using electron densities and I-values derived from the BVM coefficients. The proton stopping powers and proton ranges for the phantom materials estimated via our BVM based DECT method are compared to ICRU reference values and a post-processing DECT analysis (Yang PMB 55:1343) applied to vendorreconstructed images using the Torikoshi parametric fit model (tPFM). Results: For the phantom materials, the average stopping power estimations for 175 MeV protons derived from our method are within 1% of the ICRU reference values (except for Teflon with a 1.48% error), with an average standard deviation of 0.46% over pixels. The resultant proton ranges agree with the reference values within 2 mm. Conclusion: Our principled DECT iterative reconstruction algorithm, incorporating optimal beam hardening and scatter corrections, in conjunction with a simple linear BVM model, achieves more accurate and robust proton stopping power maps than the post-processing, nonlinear tPFM based DECT analysis applied to conventional reconstructions of low and high energy scans. Funding Support: NIH R01CA 75371; NCI grant R01 CA 149305.

60 APPLIED LIFE SCIENCES↗

Re-evaluation of Spent Nuclear Fuel Assay Data for the Three Mile Island Unit 1 Reactor and Application to Code Validation

Destructive radiochemical assay measurements of spent nuclear fuel rod segments from an assembly irradiated in the Three Mile Island unit 1 (TMI-1) pressurized water reactor have been performed at Oak Ridge National Laboratory (ORNL). Assay data are reported for five samples from two fuel rods of the same assembly. The TMI-1 assembly was a 15 X 15 design with an initial enrichment of 4.013 wt% 235 U, and the measured samples achieved burnups between 45.5 and 54.5 gigawatt days per metric ton of initial uranium (GWd/t). Measurements were performed mainly using inductively coupled plasma mass spectrometry after elemental separation via high performance liquid chromatography. High precision measurements were achieved using isotope dilution techniques for many of the lanthanides, uranium, and plutonium isotopes. Measurements are reported for more than 50 different isotopes and 16 elements. One of the two TMI-1 fuel rods measured in this work had been measured previously by Argonne National Laboratory (ANL), and these data have been widely used to support code and nuclear data validation. Recently, ORNL provided an important opportunity to independently cross check results against previous measurements performed at ANL. The measured nuclide concentrations are used to validate burnup calculations using the SCALE nuclear systems modeling and simulation code suite. These results show that the new measurements provide reliable benchmark data for computer code validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scoping Study Investigating PWR Instrumentation during a Severe Accident Scenario

The accidents at the Three Mile Island Unit 2 (TMI-2) and Fukushima Daiichi Units 1, 2, and 3 nuclear power plants demonstrate the critical importance of accurate, relevant, and timely information on the status of reactor systems during a severe accident. These events also highlight the critical importance of understanding and focusing on the key elements of system status information in an environment where operators may be overwhelmed with superfluous and sometimes conflicting data. While progress in these areas has been made since TMI-2, the events at Fukushima suggests that there may still be a potential need to ensure that critical plant information is available to plant operators. Recognizing the significant technical and economic challenges associated with plant modifications, it is important to focus on instrumentation that can address these information critical needs. As part of a program initiated by the Department of Energy, Office of Nuclear Energy (DOE-NE), a scoping effort was initiated to assess critical information needs identified for severe accident management and mitigation in commercial Light Water Reactors (LWRs), to quantify the environment instruments monitoring this data would have to survive, and to identify gaps where predicted environments exceed instrumentation qualification envelop (QE) limits. Results from the Pressurized Water Reactor (PWR) scoping evaluations are documented in this report. The PWR evaluations were limited in this scoping evaluation to quantifying the environmental conditions for an unmitigated Short-Term Station BlackOut (STSBO) sequence in one unit at the Surry nuclear power station. Results were obtained using the MELCOR models developed for the US Nuclear Regulatory Commission (NRC)-sponsored State of the Art Consequence Assessment (SOARCA) program project. Results from this scoping evaluation indicate that some instrumentation identified to provide critical information would be exposed to conditions that significantly exceeded QE limits for extended time periods for the low frequency STSBO sequence evaluated in this study. It is recognized that the core damage frequency (CDF) of the sequence evaluated in this scoping effort would be considerably lower if evaluations considered new FLEX equipment being installed by industry. Nevertheless, because of uncertainties in instrumentation response when exposed to conditions beyond QE limits and alternate challenges associated with different sequences that may impact sensor performance, it is recommended that additional evaluations of instrumentation performance be completed to provide confidence that operators have access to accurate, relevant, and timely information on the status of reactor systems for a broad range of challenges associated with risk important severe accident sequences.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-337: Dosimetric Study of TMI Using Helical Tomotherapy

Purpose: The purpose of this study is to evaluate the dosimtry of TMI using Helical Tomotherapy (HT). Methods: Whole body CT data sets of 4 patients (median age : range:12–37 years) with 5mm slice thickness were used for planning in HT (TPS version 4.2.3). The contouring of the target and organ at risks (OAR) were delineated ( Oncentra Master Plan v 4.1). Two plans were generated using 5cm and 2.5 cm field widths.The modulation factor and pitch was 3 and 0.3 respectively. Dose to PTV, OARs and the dose homogeneity were evaluated. The doses obtained were compared with the existimg literature. Dose delivery verification was carried out by point dose and 2D array measurements with ion chamber and Arc check dosimetry (Sun NuclearTM) system repectively. The prescribed dose was 14.4 Gy in 8 fractions. Results: The mean PTV volume was 7341.28cc (sd=2353) The dose homogeneity index of PTV was 12.03(sd=2.98) for 2.5cm-FW and 14.61 (sd=1.33) for 5cm-FW.The conformation number for 2.5 and 5 cm plans are 0.6328(sd=0.09) and 0.5915 (sd=0.0376) respectively. The mean dose(Gy) to the OARs were as follows for 2.5cm-FW : eyes, lens, lungs, kidneys, heart, liver,thyroid and testes for are 4.12,1.9,6.61,4.04,4.85,6.06,7.17 and 1.27. The mean dose(Gy) to the OARs were as follows for 5cm-FW :eyes, lens, lungs, kidneys, heart, liver,thyroid and testes for are 4.45,3.14,6.79,4.02,5.01,6.01,10.8 and 1.33. The mean variation of the point dose as compared to the expected dose was within 2% and the gamma analysis was at 91%. Conclusion: It was concluded that 5cm field width plans produces optimal dose volume parameters with deliverable treatment time. From this initial dissymmetric study, it was concluded that the treatment planning and the dose delivery verification was feasible considering the complexity of the TMI.

60 APPLIED LIFE SCIENCES↗

Acquisition and Processing of a Detailed Aeromagnetic Survey Glass Buttes, Oregon

Using an ultra-light aircraft, a high-resolution aeromagnetic survey was carried out over Ormat Nevada's Glass Buttes project area in Oregon. Survey operations were completed on May 25, 2010. Average terrain clearance was 223 meters from the sensor. A total of 1,352 line-miles of aeromagnetic data were acquired. Processed survey data includes a total magnetic intensity map, reduced to pole (TMI) map, horizontal gradient (RTP) map, tilt derivative (RTP) map, and a horizontal gradient map of the tilt derivative grid.

15 GEOTHERMAL ENERGY↗

Understanding Inter-Annual Variability of PV Energy Production in the Contiguous United States

Year-to-year variability of photovoltaic (PV) generation is an important factor for project financing as well as for modeling the reliability and resource adequacy of power systems. In this work, we analyze inter-annual variability of PV generation across the contiguous United States using the National Solar Radiation Database (NSRDB) from 1998 to 2014. We compare the estimated PV generation from the typical meteorological year (TMY) against the long-term mean, and find that on average the TMY tends to overpredict estimated PV production. However, we also found significant regional bias and spatial clustering in that comparison, such that there are many regional pockets of underprediction as well. Finally, we show that there is not a single year of data that most closely approximates a representative 'resource year' for all regions of the United States. These results point to the need to understand inter-annual variability at individual sites and to be aware of the shortcomings of using TMY or a single year of data for project or grid modeling.

14 SOLAR ENERGY↗

Efficient prediction of concentrating solar power plant productivity using data clustering

Concentrating solar power (CSP) plants convert solar energy to electricity and can be deployed with a thermal storage capability to shift electricity generation from time periods with available solar resource to those with high electricity demand or electricity price. Rigorous optimization of plant design and operational strategies can improve the market-competitiveness and commercial viability; however, such optimization may require hundreds of annual performance simulations, each of which can be computationally expensive when including considerations such as optimization of dispatch scheduling, sub-hourly time resolution, and stochastic effects due to uncertain weather or electricity price forecasts. This paper proposes a methodology to reduce the computational burden associated with simulation of electricity yield and revenue for CSP plants over a single- or multi-year period. Data-clustering techniques are employed to select a small number of limited-duration time blocks for simulation that, when appropriately weighted, can reproduce generation and revenue over a single year or within each year of a multi-year period. After selection of appropriate data features and weighting factors defining similarity between time-series profiles, the methodology captured annual revenue within 2.3%, 1.7%, or 1.2% using simulation of 10, 30, or 50 three-day exemplar time blocks, respectively, for each of three single-year location/weather/market scenarios and five plant configurations ranging from low to high solar multiple and storage capacity. When applied to multi-year datasets, the proposed methodology can capture inter-year variability that is unavailable from typical meteorological year (TMY) datasets while simultaneously requiring simulation of less than a single year of data.

14 SOLAR ENERGY↗

Understanding the Temporal and Spatial Variability of New Generation Gridded TMYs

Presentation at ASHRAE about the spatial and temporal variability of gridded TMYs, discussing advanced GIS and Web services that allow for direct access to data, surface-based observations for thousands of stations, climate reanalysis data, and products derived from satellite data; new developments in NREL's solar databases based on both observed data and satellite-derived gridded data, status of TMY3 weather files, and NREL's plans for the next-generation TMY weather files; and also covers what is new and different in the Climatic Design Conditions Table in the 2013 ASHRAE Handbook of Fundamentals.

54 ENVIRONMENTAL SCIENCES↗

High-Fidelity Building Emulator

This dataset provides high-fidelity time series data for an emulated commercial office building sited in the Chicago, IL area during a Typical Meteorological Year (TMY). This dataset consists of air-side HVAC measurements and control inputs, and it includes normal operations as well as various implemented faults (with associated ground truth measurements) implemented on selected days. This data could be used to quantify and compare the impacts of different faults, and it could also be used as training or validation data for machine learning algorithms (e.g., reduced-order modelling, fault detection and diagnosis).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗