Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF FACILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Silicon detectors for monitoring neutron beams in n-TOF beamlines

During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing {sup 6}Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron-induced fission cross section measurement of 233 U, 241 Am and 243 Am in the energy range 0.5 MeV En 20 MeV at n TOF at CERN

Neutron-induced fission cross section measurements of 233U, 243Am and 241Am relative to 235U have been carried out at the neutron time-of-flight facility n TOF at CERN. A fast ionization chamber has been employed. All samples were located in the same detector; therefore the studied elements and the reference 235U target are subject to the same neutron beam.

Belloni, F.↗

Resonance neutron-capture cross sections of stable magnesium isotopes and their astrophysical implications

We have measured the neutron capture cross sections of the stable magnesium isotopes {sup 24,25,26}Mg in the energy range of interest to the s process using the neutron time-of-flight facility n{_}TOF at CERN. Capture events from a natural metal sample and from samples enriched in {sup 25}Mg and {sup 26}Mg were recorded using the total energy method based on C{sub 6}{sup 2}H{sub 6} detectors. Neutron resonance parameters were extracted by a simultaneous resonance shape analysis of the present capture data and existing transmission data on a natural isotopic sample. Maxwellian-averaged capture cross sections for the three isotopes were calculated up to thermal energies of 100 keV and their impact on s-process analyses was investigated. At 30 keV the new values of the stellar cross section for {sup 24}Mg, {sup 25}Mg, and {sup 26}Mg are 3.8 {+-} 0.2 mb, 4.1 {+-} 0.6 mb, and 0.14 {+-} 0.01 mb, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Facile time-of-flight methods for characterizing pulsed superfluid helium droplet beams

We present two facile time-of-flight (TOF) methods of detecting superfluid helium droplets and droplets with neutral dopants. Without an electron gun and with only a heated filament and pulsed electrodes, the electron impact ionization TOF mass spectrometer can resolve ionized helium clusters such as He{sub 2}{sup +} and He{sub 4}{sup +}, which are signatures of superfluid helium droplets. Without ionizing any helium atoms, multiphoton non-resonant laser ionization of CCl{sub 4} doped in superfluid helium droplets at 266 nm generates complex cluster ions of dopant fragments with helium atoms, including (He){sub n}C{sup +}, (He){sub n}Cl{sup +}, and (He){sub n}CCl{sup +}. Using both methods, we have characterized our cryogenic pulsed valve—the Even-Lavie valve. We have observed a primary pulse with larger helium droplets traveling at a slower speed and a rebound pulse with smaller droplets at a faster speed. In addition, the pickup efficiency of dopant is higher for the primary pulse when the nozzle temperature is higher than 13 K, and the total time duration of the doped droplet pulse is only on the order of 20 μs. These results stress the importance of fast and easy characterization of the droplet beam for sensitive measurements such as electron diffraction of doped droplets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the mass resolving power of FRIB’s proposed high-voltage MR-ToF mass separator and spectrometer: Addressing non-ideal conditions

Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of m/Δm = 10 6 . Achieving m/Δm ≥ 3 ⋅ 10 6 would provide the ability to resolve > 90 % of all known isomeric states with half-lives above 10 ms. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. Here, to this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30 keV beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at < 3 keV beam energy will already enable mass resolving powers approaching 10 6 for FRIB’s high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching 10 7 might become feasible.

Electrostatic ion beam traps↗

197Au(n,gamma) Cross Section in the Unresolved Resonance Region

The cross section of the reaction {sup 197}Au(n,{gamma}) was measured with the time-of-flight technique at the n{_}TOF (neutron time-of-flight) facility in the unresolved resonance region between 5 and 400 keV using a pair of C{sub 6}D{sub 6} (where D denotes {sup 2}H) liquid scintillators for the detection of prompt capture {gamma} rays. The results with a total uncertainty of 3.9%-6.7% for a resolution of 20 bins per energy decade show fair agreement with the Evaluated Nuclear Data File Version B-VII.0 (ENDF/B-VII.0), which contains the standard evaluation. The Maxwellian-averaged cross section (MACS) at 30 keV is in excellent agreement with the one according to the ENDF/B-VII.0 evaluation and 4.7% higher than the MACS measured independently by activation technique. Structures in the cross section, which had also been reported earlier, have been interpreted as being due to clusters of resonances.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Scientific EFNUDAT Workshop

Part 8. The Final Scientific EFNUDAT Workshop - organized by the CERN/EN-STI group on behalf of n_TOF Collaboration - will be held at CERN, Geneva (Switzerland) from 30 August to 2 September 2010 inclusive. EFNUDAT website: http://www.efnudat.eu Topics of interest include: Data evaluation Cross section measurements Experimental techniques Uncertainties and covariances Fission properties Current and future facilities International Advisory Committee: C. Barreau (CENBG, France)T. Belgya (IKI KFKI, Hungary) E. Gonzalez (CIEMAT, Spain)F. Gunsing (CEA, France) F.-J. Hambsch (IRMM, Belgium)A. Junghans (FZD, Germany) R. Nolte (PTB, Germany)S. Pomp (TSL UU, Sweden) Workshop Organizing Committee: Enrico Chiaveri (Chairman)Marco Calviani Samuel Andriamonje Eric Berthoumieux Carlos Guerrero Roberto LositoVasilis Vlachoudis Workshop Assistant: Geraldine Jean

99 GENERAL AND MISCELLANEOUS↗

Radiation Design of Ion Mass Spectrometers

In the harsh radiation environment of Jupiter and with the JUpiter ICy moon Explorer (JUICE) mission including two Europa flybys where local intensities are approx. 150 krad/month behind 100 mils of Al shielding, so background from penetrating radiation can be a serious issue for detectors inside an Ion Mass Spectrometer (IMS). This can especially be important for minor ion detection designs. Detectors of choice for time-of-flight (TOF) designs are microchannel plates (MCP) and some designs may include solid state detectors (SSD). The standard approach is to use shielding designs so background event rates are low enough that the detector max rates and lifetimes are first not exceeded and then the more stringent requirement that the desired measurement can successfully be made (i.e., desired signal is sufficiently greater than background noise after background subtraction is made). GEANT codes are typically used along with various electronic techniques, but such designs need to know how the detectors will respond to the simulated primary and secondary radiations produced within the instrument. We will be presenting some preliminary measurements made on the response of MCPs to energetic electrons (20 ke V to 1400 ke V) using a Miniature TOF (MTOF) device and the High Energy Facility at Goddard Space Flight Center which has a Van de Graaff accelerator.

Sittler, Ed↗

Development of picoseconds Time of Flight systems in Meson Test Beam Facility at Fermilab

The goal of the work is to develop time of flight (TOF) system with about 10 picosecond time resolution in real beam line when start and stop counters separated by some distance. We name the distance as 'base' for the TOF. This 'real' TOF setup is different from another one when start and stop counters located next to each other. The real TOF is sensitive to beam momentum spread, beam divergence, etc. Anyway some preliminary measurements are useful with close placement of start and stop counter. We name it 'close geometry'. The work started about 2 years ago at Fermilab Meson Test Beam Facility (MTBF). The devices tested in 'close geometry' were Microchannel Plate Photomultipliers (MCP PMT) with Cherenkov radiators. TOF counters based on Silicon Photomultipliers (SiPms) with Cherenkov radiators also in 'close geometry' were tested. We report here new results obtained with the counters in the MTBF at Fermilab, including beam line data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-voltage MR-ToF mass spectrometer and separator for the study of exotic isotopes at FRIB

The Facility for Rare Isotope Beams (FRIB) delivers a wide variety of rare isotopes as fast, stopped, or reaccelerated beams to enable forefront research in nuclear structure, astrophysics, and fundamental interactions. To expand the scientific potential of FRIB’s stopped and reaccelerated beam programs, we are designing a Multi-Reflection Time-of-Flight mass spectrometer and separator (MR-ToF MS). It will enable high-precision mass measurements of short-lived isotopes, improve beam diagnostics, and deliver isobarically and isomerically purified beams to downstream experimental stations. It is designed to store ions at a kinetic energy of 30 keV, significantly enhancing ion throughput while maintaining high mass resolving power. In conclusion, we present the scientific motivation, technical design, and simulations demonstrating the expected performance of the system, which has the potential to significantly enhance FRIB’s mass measurement, diagnostic, and mass separation capabilities.

Electrostatic ion beam trap↗

NeuNorm

NeuNorm is a scipp-based Python library for neutron imaging normalization and time-of-flight (TOF) data processing at Oak Ridge National Laboratory imaging facilities (MARS at HFIR and VENUS at SNS). NeuNorm 2.0 is a complete, scipp-based rewrite of the original NeuNorm normalization library, adding HDF5 output, automatic uncertainty propagation, and TOF/event-mode processing.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),↗

The Neutron Macromolecular Crystallography Instruments at Oak Ridge National Laboratory: Advances, Challenges, and Opportunities

The IMAGINE and MaNDi instruments, located at Oak Ridge National Laboratory High Flux Isotope Reactor and Spallation Neutron Source, respectively, are powerful tools for determining the positions of hydrogen atoms in biological macromolecules and their ligands, orienting water molecules, and for differentiating chemical states in macromolecular structures. The possibility to model hydrogen and deuterium atoms in neutron structures arises from the strong interaction of neutrons with the nuclei of these isotopes. Positions can be unambiguously assigned from diffraction studies at the 1.5–2.5 Å resolutions, which are typical for protein crystals. Neutrons have the additional benefit for structural biology of not inducing radiation damage to protein crystals, which can be critical in the study of metalloproteins. Here we review the specifications of the IMAGINE and MaNDi beamlines and illustrate their complementarity. IMAGINE is suitable for crystals with unit cell edges up to 150 Å using a quasi-Laue technique, whereas MaNDi provides neutron crystallography resources for large unit cell samples with unit cell edges up to 300 Å using the time of flight (TOF) Laue technique. The microbial culture and crystal growth facilities which support the IMAGINE and MaNDi user programs are also described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent Results from Experiments at COSY

In hadron physics, experiments using hadronic probes may shed light on open questions on the structure of hadrons, their interactions that are subject to the strong force and on the symmetries of nature. Therefore a major focus of the physics program studied at the COoler SYnchrotron COSY of the Forschungszentrum Juelich is the production of mesons and hyperons in hadron- hadron scattering with the aim to investigate relevant production processes, interactions of the participating particles as well as symmetries and symmetry breaking. The COoler SYnchrotron COSY at Juelich accelerates protons and deuterons with momenta up to 3.7 GeV/c covering hadron physics in the light quark sector. The availability of the beam cooling systems allow precision measurements, using polarized proton and deuteron beams in combination with polarized Hydrogen or Deuterium targets. Due to the excellent experimental conditions at COSY single- and double-polarization measurements can be performed with high reaction rates. With the operation of the recently installed WASA-at-COSY apparatus, high-statistics studies aiming at rare decays of {eta} and {eta}{sup '} are effectively turning COSY into a meson factory. This contribution summarizes the ongoing physics program at the COSY facility, using the detector systems ANKE, WASA and COSY-TOF highlighting a few selective recent results and outlining future developments. The research at COSY also provides a step towards the realization of FAIR with studies on spin manipulation and polarization build-up of protons in polarized targets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of Whole Genome Sequencing and MALDI-TOF to the Identifcation of Bacillus Species Isolated from Cleanrooms at NASA Johnson Space Center

Astromaterial cleanrooms at NASA Johnson Space Center are built environments that hold samples, such as lunar rocks, from different space exploration missions. Bacillus sp. are frequently detected in routine microbial monitoring of these facilities. Since this, and related genera, can form endospores that can withstand harsh conditions, they could contaminate astromaterials. This could confound searches for extraterrestrial life. Whole genome sequencing (WGS) is widely used for identifying bacterial strains and tracking their source; however, WGS is expensive and time consuming. Matrix-assisted laser desorption ionization– time of flight mass spectrometry (MALDI-TOF) shows promise as a low-cost, rapid method of identifying strains of bacteria, but few studies have compared this proteomics method to WGS. To evaluate a high throughput method of tracking the source of contamination of this built environment, WGS and MALDI-TOF was conducted on 18 bacterial strains isolated from surfaces in astromaterials cleanrooms. WGS identified 14 Bacillus, 2 Paenibacillus, 1 Solibacillus and 1 Alcaligenes strains. These isolates showed similarity to strains commonly observed in spacecraft assembly cleanrooms at other facilities. Cluster analysis of mass spectra generated by MALDI-TOF grouped strains together that were greater than 94% similar to each other in terms of amino acid sequences of single copy core genes, as assessed by WGS. This suggests that MALDI-TOF and WGS results are consistent with each other and MALDI-TOF can rapidly identify strains of Bacillus sp. isolated from cleanroom environments with a resolution comparable to WGS. Based on phylogenomic analysis, these results also suggest the presence of a cosmopolitan class of Bacillus sp. that are more likely to be found in cleanrooms and similar built environments than in natural systems.

Farnaz Mazhari↗

Physics at COSY-Juelich

COSY, a storage and cooler synchrotron, which is fed by an injector cyclotron, is operated at Forschungszentrum Juelich (Germany). It provides phase space cooled polarized or unpolarized beams of protons and deuterons with momenta between 0.3 and 3.7 GeV/c for internal experiments and to external target stations. The major experimental facilities, used for the ongoing physics program, are ANKE and WASA (internal) and TOF (external). A new internal target station to investigate polarization build-up by spin-filtering (PAX) has recently been commissioned. COSY is the machine for hadron spin physics on a world-wide scale, which is also used for tests in conjunction with plans to build a dedicated storage ring for electric dipole moment (EDM) measurements of proton, deuteron and {sup 3}He. In this contribution recent results as well as future plans are summarized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mapping the N = 40 island of inversion: Precision mass measurements of neutron-rich Fe isotopes

Nuclear properties across the chart of nuclides are key to improving and validating our understanding of the strong interaction in nuclear physics. Here we present high-precision mass measurements of neutron-rich Fe isotopes performed at the TITAN facility. The multiple-reflection time-of-flight mass spectrometer (MR-ToF-MS), achieving a resolving power greater than 600000 for the first time, enabled the measurement of 63–70 Fe, including first-time high-precision direct measurements (δm/m ≈ 10 -7 ) of 68–70 Fe, as well as the discovery of a long-lived isomeric state in 69 Fe. These measurements are accompanied by both mean-field and ab initio calculations using the most recent realizations which enable theoretical assignment of the spin-parities of the 69 Fe ground and isomeric states. Together with mean-field calculations of quadrupole deformation parameters for the Fe isotope chain, these results benchmark a maximum of deformation in the N = 40 island of inversion in Fe and shed light on trends in level densities indicated in the newly refined mass surface.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TRACER-VOC: Speciated Volatile Organic Compounds at the Tracking Aerosol Convection Interactions Experiment Field Campaign Report

Formation of secondary organic aerosol (SOA) is responsible for the growth of particles into cloud condensation nuclei (CCN)-relevant sizes and accounts for a substantial fraction of aerosol mass in the troposphere. Despite its wide abundance and importance, capturing SOA in regional and climate models is still challenging due to complex chemical transformations involved in production of SOA. Oxidation products of biogenic hydrocarbons, such as isoprene, monoterpenes, and sesquiterpenes account for the largest fraction of SOA mass over the continents. As such, biogenic SOA is an important source of continental CCN, and has been recently shown to nucleate ice in the deposition mode. To better account for the processes involved in SOA formation in global and regional climate models, we need better measurements of sources and transformations of volatile organic compounds (VOCs), the precursors to SOA formation in the atmosphere. Understanding aerosol-deep convection interactions is an important science driver of the Tracking Aerosol Convection Interactions Experiment (TRACER), requiring a characterization of the critical controls on aerosol properties and processes, and how those properties and processes vary spatially and temporally in the Houston area. In that environment, the atmospheric photo-oxidative chemistry that drives the evolution and transformation of aerosol properties and processes is strongly impacted by the emission of VOCs, which have both anthropogenic (e.g., industrial, urban, transportation, biomass burning) and biogenic (e.g., marine) sources in the region. Understanding (and disentangling) the complex role of VOCs in such a heterogenous region requires high-time-resolution, speciated VOC measurements that are spatially resolved. To meet these measurement requirements, the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s time-of-flight proton transfer reaction-mass spectrometer (ToF-PTR-MS) was deployed during the TRACER intensive operational period (IOP) from June to September, 2022 at the ancillary site (ANC), which was sited to provide a characterization of the rural atmospheric environment in contrast to the main site.

54 ENVIRONMENTAL SCIENCES↗