Space station trace contaminant control
Different systems for the control of space station trace contaminants are outlined. The issues discussed include: spacecabin contaminant sources, technology base, contaminant control system elements and configuration, approach to contaminant control, contaminant load model definition, spacecraft maximum allowable concentrations, charcoal bed sizing and performance characteristics, catalytic oxidizer sizing and performance characteristics, special sorbent bed sizing, animal and plant research payload problems, and emergency upset contaminant removal. It is concluded that the trace contaminant control technology base is firm, the necessary hardware tools are available, and the previous design philosophy is still applicable. Some concerns are the need as opposed to danger of the catalytic oxidizer, contaminants with very low allowable concentrations, and the impact of relaxing materials requirements.