Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRANSMISSION EFFICIENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Peptoid-Based Nanosheets Exhibiting Broad Antiviral Activity Against Enveloped RNA Viruses

Enveloped RNA viruses, such as Influenza A (H1N1) and Sindbis virus, pose persistent global health threats due to their high mutation rates, efficient transmission, and frequent drug resistance. By mimicking host cell membrane receptors, multivalent virus inhibitors can block viral attachment, making them promising broad-spectrum antiviral agents. However, most of existing antivirals are often limited by strain specificity, short-lived efficacy, and toxicity. Here, we introduce a broad-spectrum antiviral platform based on highly tunable and biocompatible two-dimensional nanomembranes (2DNMs) self-assembled from amphiphilic peptoids, operating via a non-genomic, mutation-insensitive mechanism. By varying peptoid sequence, we design and synthesize over twenty different 2DNMs with various surface charge and high density of viral-attachment ligands (VALs). The self-assembled architecture of these stable 2DNMs provides cooperative noncovalent multivalent binding to virus particles that result in effective inhibition of viral infection. Screening of variants identified three leads that potently suppressed Influenza A (H1N1) and Sindbis virus infection across median tissue culture infectious dose (TCID50), plaque, RT–qPCR, and immunofluorescence assays, while maintaining >90% cell viability. These nanosheets significantly reduced infectious titers, viral RNA replication, and intracellular viral protein expression, indicating inhibition at early stages of viral entry and propagation. The sequence programmability, chemical robustness, and mutation-insensitive antiviral activity distinguish 2DNMs from traditional antivirals and positions them as a versatile materials platform for antiviral coatings, protective barriers, and prophylactic biomedical applications.

Influenza A virus↗

Evaluation of Waveform Profiles for Traveling Wave Ion Mobility Separations in Structures for Lossless Ion Manipulations

Structures for lossless ion manipulations (SLIM) have recently enabled a powerful implementation of traveling wave ion mobility spectrometry (TWIMS) for ultra-high resolution separations. However, optimization of experimental parameters remains challenging. Most TWIMS separations have utilized square-shaped waveforms applied by time-dependent voltage stepping across a repeating sets of electrodes; however, alternative waveforms may provide further improvements to resolution. In this work, we characterize five waveforms (including square and sine) in terms of their transmission efficiency, IMS resolution, and resolving power, and explore the effects of TW amplitude and speed on the performance of each. We found, consistent with previous work, separations were generally improved with higher TW amplitudes, moderately improved by lower speeds (limited by ion ‘surfing’ with the waves), and found decreases in signal intensity at the extremes of operating conditions. The triangle and asymmetric ‘ramp forward’ shaped profiles were found to provide modestly greater resolution and resolving power, an observation we tentatively attribute to their relatively uniform fields and minimal low-field regions.

59 BASIC BIOLOGICAL SCIENCES↗

Advances in phosphor two-color ratio method thermography for full-field surface temperature measurements

We report thermographic phosphors can be employed for optical sensing of surface, gas phase, and bulk material temperatures through different strategies including the time-decay method, time-integrated method, and frequency-domain method. We focus on the time-integrated method, also known as the ratio method, as it can be more practical in many situations. This work advances the ratio method using two machine vision cameras with CMOS detectors for full-field temperature measurements of a solid surface. A phosphor calibration coupon is fabricated using aerosol deposition and employed for in situ determination of the temperature-versus-intensity ratio relationship. Algorithms from digital image correlation are employed to determine the stereoscopic imaging system intrinsic and extrinsic parameters, and accurately register material points on the sample to subpixel locations in each image with 0.07 px or better accuracy. Detector nonlinearity is carefully characterized and corrected. Temperature-dependent, spatial non-uniformity of the full-field intensity ratio—posited to be caused by a blue-shift effect of the bandpass filter for non-collimated light and/or a wavelength-dependent transmission efficiency of the lens—is assessed and treated for cases where a standard flat-field correction fails to correct the non-uniformity. In sum, pixel-wise calibration curves relating the computed intensity ratio to temperature in the range of T = 300–430 K are generated, with an embedded error of less than 3 K. This work offers a full calibration methodology and several improvements on two-color phosphor thermography, opening the door for full-field temperature measurements in dynamic tests with deforming test articles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations and seismoacoustic simulations of earthquake-generated infrasound waves in non-epicentral regions

We analysed infrasound waves associated with the Gyeongju earthquake (ML 5.8) that occurred on 2016 September 12, in the southeastern Korean Peninsula. For infrasound wave detection, the Progressive Multichannel Correlation method was applied to the infrasound data set recorded at seven arrays operating in South Korea at epicentral distances ranging from 178 to 472 km. Based on the back-projection method constrained by array-dependent celerity and azimuth deviation models, the source regions were identified in both the epicentral and non-epicentral regions. Remarkably, the non-epicentral secondary sources of this earthquake were located in regions with shallow water depths: (i) the western coastal area in the Yellow Sea and (ii) the shallow ocean basin and bank in the East Sea. The location results obtained from the earthquake could be corroborated through its foreshock (ML 5.1), yielding location results consistent with those of the main shock. The generation of infrasound waves over shallow water depths was fortuitously validated by direct recordings of dominant single-frequency (~0.3 Hz) infrasound waves at close range via temporary sensors near the ocean basin and bank. We interpreted that low-frequency infrasound signals could be generated from interactions among the ocean floor, shallow seawater and atmosphere. We performed numerical simulations of seismoacoustic fields to predict ground motions on the seafloor and acoustic transmission efficiency between the water and air interface. The simulations quantified the energy transfer through different media and clarified our observational results. We found that because this solid Earth‒water‒atmosphere coupled air wave has a relatively low frequency (~0.3 Hz), it can survive propagation over long distances compared with high-frequency infrasound waves generated in inland and mountain regions. In this study, we extend our understanding of water‒atmosphere coupling and the monitoring framework for earthquake-associated non-epicentral infrasound waves, encompassing not only inland ground shaking but also shallow sea regions located far from the epicentre.

Earthquake monitoring and test-ban treaty verifica↗

Operation of normal-conducting rf cavities in multi-Tesla magnetic fields for muon ionization cooling: A feasibility demonstration

Ionization cooling is the preferred method for producing bright muon beams. This cooling technique requires the operation of normal conducting, radio-frequency (rf) accelerating cavities within the multi-tesla fields of dc solenoid magnets. Under these conditions, cavities exhibit increased susceptibility to rf breakdown, which can damage cooling channel components and imposes limits on channel length and transmission efficiency. We report, for the first time, stable high-vacuum, normal-conducting cavity operation at gradients of 50 MV / m in an external magnetic field of three tesla, through the use of beryllium cavity elements. This eliminates a significant technical risk that has previously been inherent in ionization cooling channel designs.

43 PARTICLE ACCELERATORS↗

Membrane Metasurfaces

We introduce Mie-resonant dielectric membrane metasurfaces for THz frequencies. We design silicon membrane metasurfaces with the 2π phase coverage and high transmission efficiencies to provide novel opportunities for an efficient wavefront control and multifunctional operations.

Yang, Quanlong↗

Comparative study of spectral broadening and few-cycle compression of Yb:KGW laser pulses in gas-filled hollow-core fibers

While industrial-grade Yb-based amplifiers have become very prevalent, their limited gain bandwidth has created a large demand for robust spectral broadening techniques that allow for few-cycle pulse compression. In this work, we perform a comparative study between several atomic and molecular gases as media for spectral broadening in a hollow-core fiber geometry. Exploiting nonlinearities such as self-phase modulation, self-steepening, and stimulated Raman scattering, we explore the extent of spectral broadening and its dependence on gas pressure, the critical power for self-focusing, and the optimal regime for few-cycle pulse compression. Using a 3-mJ, 200-fs input laser pulses, we achieve 17 fs, few-cycle pulses with 80% fiber energy transmission efficiency. The optimal parameters can be scaled for higher or lower input pulse energies with appropriate gas parameters and fiber geometry.

Shalaby, Islam (ORCID:0000000332846636)↗

Fermilab Booster loss modelling and rebalancing using Bayesian methods

To meet PIP-II upgrade requirements, Fermilab Booster losses need to be reduced by 50% compared to present levels. So far, simulations are not good enough to predict loss patterns. Thus, an extensive Booster tune up will be necessary to achieve required performance. In this paper we present an effort to build a data-driven loss model using Bayesian techniques, and subsequently to rebalance losses for higher trip margins. We first created several sets of spatially and temporally isolated orbit and optics knobs, and trained Gaussian process models for each beam loss monitor as well as beam current. Novel techniques of uncertainty constraints and approximate GP fitting were introduced to handle safety and timing requirements. We then performed single and multi-objective tuning using scalarized objectives comprised of critical beam loss locations. We achieved significant rebalancing of losses, increasing margins by 25%, as well as an overall improvement in transmission efficiency of 0.4%. Automated data collection is being developed so that more accurate surrogate models can be trained over time.

Kuklev, N. [Fermilab]↗

Ion Beam Propagation Through the FNAL LEBT

The Fermilab 750keV injector sends 25mA H- beam for 30µs at a rep-rate of 15Hz. The beam transmission through the FNAL injector is currently less than 50% from the ion source to the entrance of the drift tube linac. Recently it was uncovered that the primary loss point is within the region prior to the RFQ which houses the solenoid focal elements that match the beam to the RFQ. Recent diagnostic measurements indicate that the cause of the transmission efficiency could be the non-linear effects of the solenoid elements on the beam. An aperture restriction was placed just upstream of the first solenoid element to restrict the beam size and reduce the non-linear effects of the solenoid element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the Fermilab Linac Injector

The Fermilab Linac injection line consists of a 35 keV magnetron-type H- ion source, two-solenoid Low Energy Beam Transport (LEBT), 201 MHz 4-rod 750 keV Radio Frequency Quadrupole (RFQ), and a Medium Energy Transport (MEBT) containing 4 quadrupoles and a bunching cavity. The injector delivers 25 mA, 48 s pulses to drift-tube Linac at a repetition rate of 15Hz. The transmission efficiency has been lower than expected since commissioning. Recent beam current measurements suggest that the beam is primarily lost upstream of the RFQ exit. Numerical simulations indicate that ions passing through the non-linear field region of the solenoids could produce a beam with an increased emittance resulting in up to 50 % of the LEBT beam current failing to meet the RFQ acceptance. An aperture restriction was installed upstream of the first solenoid to remove these ions. This report describes the results of measurements and simulations as well as the LEBT tuning.

Jones, Daniel C.↗

Fermilab Booster loss modelling and rebalancing using Bayesian methods

Fermilab Booster is being upgraded for the PIP-II project to support 20Hz ramp rate at higher intensities. Loss trip limits determine the achievable peak power. To meet PIP-II requirements, losses need to be halved as compared to current levels. Losses primarily occur at injection and transition crossing, with both gradually increasing and threshold-like intensity-dependent behaviors. The existing simulation models are not yet good enough for quantitative loss predictions. In practice, it will be necessary to tune up the Booster using iterative methods and operator intuition. In this paper we present an effort to systematically model Booster losses using active learning (Bayesian exploration) techniques, and subsequently to rebalance them for higher trip limit margins. We first created several sets of spatially and temporally isolated orbit and optics knobs, and trained Gaussian process models for each beam loss monitor as well as beam current. This is a complex task due to safety and timing requirements – we discuss mitigations such as uncertainty constraints and approximate fitting. Once models are stable, we perform large-scale single and multi-objective tuning using scalarized objectives made up of critical beam loss locations. Our results demonstrate significant rebalancing of losses, increasing trip margins, as well as an overall improvement in beam transmission efficiency. We are exploring how to combine existing simulations with experimental data and automate the collection procedure so that more advanced surrogate models can be created over time.

Kuklev, Nikita [Fermilab]↗

Interspecies Transmission from Pigs to Ferrets of Antigenically Distinct Swine H1 Influenza A Viruses with Reduced Reactivity to Candidate Vaccine Virus Antisera as Measures of Relative Zoonotic Risk

During the last decade, endemic swine H1 influenza A viruses (IAV) from six different genetic clades of the hemagglutinin gene caused zoonotic infections in humans. The majority of zoonotic events with swine IAV were restricted to a single case with no subsequent transmission. However, repeated introduction of human-seasonal H1N1, continual reassortment between endemic swine IAV, and subsequent drift in the swine host resulted in highly diverse swine IAV with human-origin genes that may become a risk to the human population. To prepare for the potential of a future swine-origin IAV pandemic in humans, public health laboratories selected candidate vaccine viruses (CVV) for use as vaccine seed strains. To assess the pandemic risk of contemporary US swine H1N1 or H1N2 strains, we quantified the genetic diversity of swine H1 HA genes, and identified representative strains from each circulating clade. We then characterized the representative swine IAV against human seasonal vaccine and CVV strains using ferret antisera in hemagglutination inhibition assays (HI). HI assays revealed that 1A.3.3.2 (pdm09) and 1B.2.1 (delta-2) demonstrated strong cross reactivity to human seasonal vaccines or CVVs. However, swine IAV from three clades that represent more than 50% of the detected swine IAVs in the USA showed significant reduction in cross-reactivity compared to the closest CVV virus: 1A.1.1.3 (alpha-deletion), 1A.3.3.3-clade 3 (gamma), and 1B.2.2.1 (delta-1a). Representative viruses from these three clades were further characterized in a pig-to-ferret transmission model and shown to exhibit variable transmission efficiency. Our data prioritize specific genotypes of swine H1N1 and H1N2 to further investigate in the risk they pose to the human population.

60 APPLIED LIFE SCIENCES↗

High Power Radiofrequency Operation of the Radiofrequency Quadrupoles in the Spallation Neutron Source

The Spallation Neutron Source (SNS) recently took delivery of a third Radiofrequency Quadrupole (RFQ03) that will ultimately be installed on the front-end (FE) of the SNS Linac. The first RFQ (RFQ01) operated in the SNS FE for more than a decade before being replaced with the second RFQ (RFQ02). RFQ01 was relocated to the Beam Test Facility (BTF) where it operated for five more years. The RFQ02 was initially installed in the BTF for high power testing and used with H- beam for BTF operation. It replaced RFQ01 in the SNS FE in 2017 and has been operating for beam production since then. There are some differences between the three RFQs. RFQ01 has a square cross-section with pi-mode stabilizing loops (PISLs) with the structure being fabricated using two layers of materials, GlidCop outside and OFHC inside. RFQ02 and RFQ03 has an octagonal cross-section with end-wall stabilizer rods and was fabricated using OFHC only. RFQ01 suffered some field flatness distortion incidents that resulted in degradation in beam transmission efficiency and required RF tuning. RFQ02 has performed well but had a melted RF seal in the high energy end wall, that was ultimately mitigated by a redesign of the end flange seals. The SNS decided to order RFQ03 that has a design that followed that of RFQ02 closely, but end-wall contacts were modified to prevent RF seal failure. This report presents the testing, installation, high power RF operation, and design improvements of the RFQ03.

Ren, Haitao↗

Modeling the CEBAF Injector at 200 kV: Investigating K-Long Beam Conditions with and without Wien Filter

The upcoming K-Long experiment [1] ain Hall D at Jefferson Lab presents unique beam requirements, featuring a significantly low bunch repetition rate and an unusually high bunch charge. This experiment, which utilizes the CEBAF accelerator in conjunction with the GlueX experimental setup, aims to study strange hadron spectroscopy by measuring the differential cross section and polarizations of produced hyperons such as Λ, Σ, Ξ, and Ω. By directing an intense K-Long beam towards the LD2/LH2 target, new and valuable data can be obtained. To optimize the CEBAF injector specifically for this experiment, we employed Multi-Objective Genetic Optimization (MGO) using General Particle Tracer (GPT) simulations. Through this approach, we determined the optimal magnetic elements and radiofrequency (RF) settings required to achieve a K-Long bunch charge of 0.64 pC at an energy of 200 kV. We conducted simulations with both the Wien Filter turned on and off to examine its impact on the beam. Furthermore, we investigated the transmission efficiency and beam characteristics of electron beams with varying charge per bunch through the injector, considering the simultaneous operation of all four CEBAF Halls. The results of our study offer valuable insights and guidance for optimizing the CEBAF injector not only for the Jefferson Lab K-Long experiment but also for other experiments that entail similar beam conditions.

Pokharel, Sunil↗

Performance of the Fermilab Linac Injector

The Fermilab Linac injection line consists of a 35 keV magnetron-type H- ion source, two-solenoid Low Energy Beam Transport (LEBT), 201 MHz 4-rod 750 keV Radio Frequency Quadrupole (RFQ), and a Medium Energy Transport (MEBT) containing 4 quadrupoles and a bunching cavity. The injector delivers 25 mA, 48 s pulses to drift-tube Linac at a repetition rate of 15Hz. The transmission efficiency has been lower than expected since commissioning. Recent beam current measurements suggest that the beam is primarily lost upstream of the RFQ exit. Numerical simulations indicate that ions passing through the non-linear field region of the solenoids could produce a beam with an increased emittance resulting in up to 50 % of the LEBT beam current failing to meet the RFQ acceptance. An aperture restriction was installed upstream of the first solenoid to remove these ions. This report describes the results of measurements and simulations as well as the LEBT tuning.

Jones, Daniel C.↗

Performance of the Fermilab Linac Injector

The Fermilab Linac injection line consists of a 35 keV magnetron-type H\textsuperscript{-} ion source, two-solenoid Low Energy Beam Transport (LEBT), 201 MHz 4-rod 750 keV Radio Frequency Quadrupole (RFQ), and a Medium Energy Transport (MEBT) containing 4 quadrupoles and a bunching cavity. The injector delivers 25 mA, 48 µs pulses to the drift-tube Linac at a repetition rate of 15Hz. The transmission efficiency of the injector has been lower than expected since commissioning. Recent beam current measurements suggest that the beam is primarily lost upstream of the RFQ exit. Numerical simulations indicate that ions passing through the non-linear field region of the solenoids could produce a beam with an increased emittance resulting in up to 50\% of the LEBT beam current failing to meet the RFQ acceptance. An aperture restriction was installed upstream of the first solenoid to remove these ions. This report describes the results of measurements and simulations as well as the LEBT tuning.

43 PARTICLE ACCELERATORS↗

Enhancing Short-Term Flexibility through Characterization of HVDC Transmission Systems

Efficient power grid operation hinges on maintaining safety and reliability through adaptable system flexibility standards. However, in a future power grid characterized by extensive renewable energy integration, conventional system flexibility and predetermined requirements may falter under extreme conditions. This paper addresses the formidable challenge of sustaining secure and dependable power grid operations under these circumstances, emphasizing the role of controllable high voltage direct current (HVdc) transmission systems in amplifying overall system flexibility and tackling operational complexities. To quantitatively assess short-term flexibility and its associated economic benefits from HVdc within specific regions, we propose a Power Flow Distribution Factors (PTDFs) based approach. This methodology takes into account both dispatchable generators and HVdc systems, pinpointing their contributions. Through an analysis of the Western Electricity Coordinating Council (WECC) system, we demonstrate the practical application of this approach to scrutinize the impacts of existing and future HVdc lines.

Operational Flexibility, Multi-terminal HVdc, tran↗