Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRAUMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multimodality imaging of the male urethra: trauma, infection, neoplasm, and common surgical repairs

Objective: The aim of this article is to describe the indications and proper technique for RUG and MRI, their respective image findings in various disease states, and the common surgical techniques and imaging strategies employed for stricture correction. Results: Because of its length and passage through numerous anatomic structures, the adult male urethra can undergo a wide array of acquired maladies, including traumatic injury, infection, and neoplasm. For the urologist, imaging plays a crucial role in the diagnosis of these conditions, as well as complications such as stricture and fistula formation. While retrograde urethrography (RUG) and voiding cystourethrography (VCUG) have traditionally been the cornerstone of urethral imaging, MRI has become a useful adjunct particularly for the staging of suspected urethral neoplasm, visualization of complex posterior urethral fistulas, and problem solving for indeterminate findings at RUG. Conclusions: Familiarity with common urethral pathology, as well as its appearance on conventional urethrography and MRI, is crucial for the radiologist in order to guide the treating urologist in patient management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Creation of a prototype biomimetic fish to better understand impact trauma caused by hydropower turbine blade strikes

Biomimetic model organisms could be useful surrogates for live animals in many applications if the models have sufficient biofidelity. One such application is for use in field and laboratory tests of fish mortality associated with passage through hydropower turbines. Laboratory trials suggest that blade strikes are especially injurious and often causes mortality when fish are struck by thinner blades moving at higher velocities. Dose-response relationships have been created from these data, but the exact relationship between fish mortality and the actual forces enacted on fish during simulated blade strike testing remains unknown. Here, we describe the methods used to create a prototype biomimetic model fish composed of ballistic gelatin and covered with a surrogate skin to better approximate the biomechanical properties of a fish body. Frozen fish were scanned with high-fidelity laser scanners, and a 3D-printed, reusable mold was created from which to cast our gelatin model. Computed tomography scan data, imaged directly or taken from online data repositories, were also successfully used to create CAD models for use in additive manufacturing of molds. One 3-axis accelerometer was embedded into the gelatin to compare accelerometer data to dose-response data from previous laboratory research on live fish. The resulting model ( i.e. , Gelfish) had a statistically indistinguishable tissue durometer to that of real fish tissue and preliminary blade strike impact testing suggested its overall flexibility was similar to that of live fish. Gelfish was designed with biofidelity as its guiding principle and our results suggest initial experimentation was successful. Future research will include replication of initial Gelfish test results, quantitative measurement of model flexibility relative to real fish, and inclusion of surrogate skeletal structures to enhance biofidelity. Use of more sophisticated sensors would also better quantify the physical forces of blade strike impact and help determine how said forces correlate with rates of mortality observed during tests on live fish.

36 MATERIALS SCIENCE↗

Bolide impacts, acid rain, and biospheric traumas at the Cretaceous-Tertiary boundary

Two plausible projectiles are considered: an ice-rich long-period comet and a much smaller rock-metal asteroid. In the framework of a proposal addressed by Lewis et al. (1982), it is shown that, while the impact projectiles themselves do not shock-heat the atmosphere very extensively, the supersonic plume of water vapor and rock produced on impact does shock the atmosphere up to global scales and the shock is of sufficient intensity to produce abundant nitric oxide. For example, an ice-rich long-period comet with a mass of 1.25 x 10 to the 16th kg and a velocity of 65 km/s striking the earth would produce about 7 x 10 to the 40th molecules NO through shock-heating of the atmosphere by the high-velocity ejecta plume fragments. Specific attention is given to the fraction of the atmosphere shock-heated, the global circulation of the nitrogen oxides, the effects of the ejecta plume water on acid rain (AR) predictions, the effects of AR on continental soils, the relationship between AR production rates and the total amount of acid needed to acidify the surface oceans, and the longevity of the oceanic acidity event and the exhaled CO2 event and their implications for the environment in the first millenia or so after the impact.

Prinn, Ronald G.↗

Spacesuit Glove-Induced Hand Trauma and Analysis of Potentially Related Risk Variables

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. Glove injuries, both anecdotal and recorded, have been reported during EVA training and flight persistently through NASA's history regardless of mission or glove model. Theories as to causation such as glove-hand fit are common but often lacking in supporting evidence. Previous statistical analysis has evaluated onycholysis in the context of crew anthropometry only (Opperman et al 2010). The purpose of this study was to analyze all injuries (as documented in the medical records) and available risk factor variables with the goal to determine engineering and operational controls that may reduce hand injuries due to the EVA glove in the future. A literature review and data mining study were conducted between 2012 and 2014. This study included 179 US NASA crew who trained or completed an EVA between 1981 and 2010 (crossing both Shuttle and ISS eras) and wore either the 4000 Series or Phase VI glove during Extravehicular Mobility Unit (EMU) spacesuit EVA training and flight. All injuries recorded in medical records were analyzed in their association to candidate risk factor variables. Those risk factor variables included demographic characteristics, hand anthropometry, glove fit characteristics, and training/EVA characteristics. Utilizing literature, medical records and anecdotal causation comments recorded in crewmember injury data, investigators were able to identify several risk factors associated with increased risk of glove related injuries. Prime among them were smaller hand anthropometry, duration of individual suited exposures, and improper glove-hand fit as calculated by the difference in the anthropometry middle finger length compared to the baseline EVA glove middle finger length.

McFarland, Shane M.↗

Spacesuit Glove-Induced Hand Trauma and Analysis of Potentially Related Risk Variables

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. Glove injuries, both anecdotal and recorded, have been reported during EVA training and flight persistently through NASA's history regardless of mission or glove model. Theories as to causation such as glove-hand fit are common but often lacking in supporting evidence. Previous statistical analysis has evaluated onycholysis in the context of crew anthropometry only. The purpose of this study was to analyze all injuries (as documented in the medical records) and available risk factor variables with the goal to determine engineering and operational controls that may reduce hand injuries due to the EVA glove in the future. A literature review and data mining study were conducted between 2012 and 2014. This study included 179 US NASA crew who trained or completed an EVA between 1981 and 2010 (crossing both Shuttle and ISS eras) and wore either the 4000 Series or Phase VI glove during Extravehicular Mobility Unit (EMU) spacesuit EVA training and flight. All injuries recorded in medical records were analyzed in their association to candidate risk factor variables. Those risk factor variables included demographic characteristics, hand anthropometry, glove fit characteristics, and training/EVA characteristics. Utilizing literature, medical records and anecdotal causation comments recorded in crewmember injury data, investigators were able to identify several risk factors associated with increased risk of glove related injuries. Prime among them were smaller hand anthropometry, duration of individual suited exposures, and improper glove-hand fit as calculated by the difference in the anthropometry middle finger length compared to the baseline EVA glove middle finger length.

Charvat, Chacqueline M.↗

Strategies for Small Volume Resuscitation: Hyperosmotic-Hyperoncotic Solutions, Hemoglobin Based Oxygen Carriers and Closed-Loop Resuscitation

Introduction: Logistic constraints on combat casualty care preclude traditional resuscitation strategies which can require volumes and weights 3 fold or greater than hemorrhaged volume. We present a review of quantitative analyses of clinical and animal data on small volume strategies using 1) hypertonic-hyperosmotic solutions (HHS); 2) hemoglobin based oxygen carriers (HBOCs) and 3) closed-loop infusion regimens.Methods and Results: Literature searches and recent queries to industry and academic researchers have allowed us to evaluate the record of 81 human HHS studies (12 trauma trials), 19 human HBOCs studies (3trauma trials) and two clinical studies of closed-loop resuscitation.There are several hundreds animal studies and at least 82 clinical trials and reports evaluating small volume7.2%-7.5% hypertonic saline (HS) most often combined with colloids, e.g., dextran (HSD) or hetastarch(HSS). HSD and HSS data has been published for 1,108 and 392 patients, respectively. Human studies have documented volume sparing and hemodynamic improvements. Meta-analyses suggest improved survival for hypotensive trauma patients treated with HSD with significant reductions in mortality found for patients with blood pressure < 70 mmHg, head trauma, and penetrating injury requiring surgery. HSD and HSS have received regulatory approval in 14 and 3 countries, respectively, with 81,000+ units sold. The primary reported use was head injury and trauma resuscitation. Complications and reported adverse events are surprisingly rare and not significantly different from other solutions.HBOCs are potent volume expanders in addition to oxygen carriers with volume expansion greater than standard colloids. Several investigators have evaluated small volume hyperoncotic HBOCs or HS-HBOC formulations for hypotensive and normotensive resuscitation in animals. A consistent finding in resuscitation with HBOCs is depressed cardiac output. There is some evidence that HBOCs more efficiently unload oxygen from plasma hemoglobin as well as facilitate RBC unloading. We analyzed one volunteer study, 15 intraoperative trials, and 3 trauma studies using HBOCs. Perioperative studies generally suggest ability to deliver oxygen, but one trauma trial using HBOCs (HemAssist) for treatment of trauma resulted in a dramatic increase in mortality, while an intraoperative trauma study using Polyheme demonstrated reductions in blood use and lower mortality compared to historic controls of patients refusing blood. Transfusion reductions with HBOC use have been modest. Two HBOCs (Hemopure and Polyheme) are now in new or planned large-scale multicenter prehospital trials of trauma treatment. A new implementation of small volume resuscitation is closed-loop resuscitation (CLR), which employs microprocessors to titrate just enough fluid to reach a physiologic target . Animal studies suggest less risk of rebleeding in uncontrolled hemorrhage and a reduction in fluid needs with CLR. The first clinical application of CLR was treatment of burn shock and the US Army. Conclusions: Independently sponsored civilian trauma trials and clinical evaluations in operational combat conditions of different small volume strategies are warranted.

Kramer, George C.↗

Optimization of a Lethal, Combat-Relevant Model of Sterile Inflammation in Mice for Drug Candidate Screening

ABSTRACT Introduction Extensive trauma, commonly seen in wounded military Service Members, often leads to a severe sterile inflammation termed systemic inflammatory response syndrome (SIRS), which can progress to multiple organ dysfunction syndrome (MODS) and death. MODS is a serious threat to wounded Service Members, historically causing 10% of all deaths in trauma admissions at a forward deployed combat hospital. The importance of this problem will be exacerbated in large-scale combat operations, in which evacuation will be delayed and care of complex injuries at lower echelons of care may be prolonged. The main goal of this study was to optimize an existing mouse model of lethal SIRS/MODS as a therapeutic screening platform for the evaluation of immunomodulatory drugs. Materials and Methods Male C57BL/6 mice were euthanized, and the bones and muscles were collected and blended into a paste termed tissue–bone matrix (TBX). The TBX at 12.5%–20% relative to body weight of each recipient mouse was implanted into subcutaneous pouches created on the dorsum of anesthetized animals. Mice were observed for clinical scores for up to 48 hours postimplantation and euthanized at the preset point of moribundity. To test effects of anesthetics on TBX-induced mortality, animals received isoflurane or ketamine/xylazine (K/X). In a separate set of studies, mice received TBX followed by intraperitoneal injection with 20 mg/kg or 40 mg/kg Eritoran or a placebo carrier. All Eritoran studies were performed in a blinded fashion. Results We observed that K/X anesthesia significantly increased the lethality of the implanted TBX in comparison to inhaled anesthetics. Although all the mice anesthetized with isoflurane and implanted with 12.5% TBX survived for 24 hours, 60% of mice anesthetized with K/X were moribund by 24 hours postimplantation. To mimic more closely the timing of lethal SIRS/MODS following polytrauma in human patients, we extended observation to 48 hours. We performed TBX dose–response studies and found that as low as 15%, 17.5%, and 20% TBX caused moribundity/mortality in 50%, 80%, and 100% mice, respectively, over a 48-hour time period. With 17.5% TBX, we tested if moribundity/mortality could be rescued by anti-inflammatory drug Eritoran, a toll-like receptor 4 antagonist. Neither 20 mg/kg nor 40 mg/kg doses of Eritoran were found to be effective in this model. Conclusions We optimized a TBX mouse model of SIRS/MODS for the purpose of evaluating novel therapeutic interventions to prevent trauma-related pathophysiologies in wounded Service Members. Negative effects of K/X on lethality of TBX should be further evaluated, particularly in the light of widespread use of ketamine in treatment of pain. By mimicking muscle crush, bone fracture, and necrosis, the TBX model has pleiotropic effects on physiology and immunology that make it uniquely valuable as a screening tool for the evaluation of novel therapeutics against trauma-induced SIRS/MODS.

General & Internal Medicine↗

Supervisory Algorithm for Autonomous Hemodynamic Management Systems

Future military conflicts will require new solutions to manage combat casualties. The use of automated medical systems can potentially address this need by streamlining and augmenting the delivery of medical care in both emergency and combat trauma environments. However, in many situations, these systems may need to operate in conjunction with other autonomous and semi-autonomous devices. Management of complex patients may require multiple automated systems operating simultaneously and potentially competing with each other. Supervisory controllers capable of harmonizing multiple closed-loop systems are thus essential before multiple automated medical systems can be deployed in managing complex medical situations. The objective for this study was to develop a Supervisory Algorithm for Casualty Management (SACM) that manages decisions and interplay between two automated systems designed for management of hemorrhage control and resuscitation: an automatic extremity tourniquet system and an adaptive resuscitation controller. SACM monitors the required physiological inputs for both systems and synchronizes each respective system as needed. We present a series of trauma experiments carried out in a physiologically relevant benchtop circulatory system in which SACM must recognize extremity or internal hemorrhage, activate the corresponding algorithm to apply a tourniquet, and then resuscitate back to the target pressure setpoint. SACM continues monitoring after the initial stabilization so that additional medical changes can be quickly identified and addressed, essential to extending automation algorithms past initial trauma resuscitation into extended monitoring. Overall, SACM is an important step in transitioning automated medical systems into emergency and combat trauma situations. Future work will address further interplay between these systems and integrate additional medical systems.

42 ENGINEERING↗

Evaluation of Critical Care Monitor Technology During the US Navy Strong Angel Exercise

The NASA critical path road map identifies "trauma and acute medical problems" as a clinical capability risk category (http://criticalDath.isc.nasa.gov). Specific risks include major trauma, organ laceration or contusion, hemoperitoneum, pulmonary failure, pneumo- and hemothorax, burn, open bone fracture, blunt head trauma, and penetrating injury. Mitigation of these risks includes the capability for critical care monitoring. Currently, the International Space Station (ISS) Crew Health Care System (CHeCS) does not provide such a capability. The Clinical Space Medicine Strategic Planning Forum (4/8/97), sponsored by NASA Medical Operations, identified the development of trauma care capabilities as one of the top priorities for space medicine. The Clinical Care Capability Development Project (CCCDP) subsequently undertook the task to address this need.

Johannesen, John↗

Lifetime risk of suicide among survivors of the atomic bombings of Japan

Abstract Aims The long-term physical health effects of the atomic bombings of Hiroshima and Nagasaki are well characterised, but the psychological effects remain unclear. Therefore, we sought to determine whether measures of exposure severity, as indirect measures of psychological trauma arising from exposure to the atomic bombings, are associated with suicide mortality among atomic bomb survivors. Methods The Life Span Study is a prospective cohort study of 93 741 Japanese atomic bomb survivors who were located within 10 km of the hypocentre in Hiroshima or Nagasaki at the time of the bombings in 1945, and 26 579 residents of Hiroshima and Nagasaki who were not in either city at the time of the bombings, matched to survivors on city, sex and age. Measures of exposure severity included: proximity to the hypocentre, type of shielding between the survivor and the blast and self-reported occurrence of acute radiation and thermal injuries. Date of death was obtained from the Japanese National Family Registry system. Cause of death was obtained from death certificates. Adjusted hazard ratios (HRs) were estimated from Cox regression models overall and stratified by sex and age. Results During the 60-year follow-up period (1950–2009), 1150 suicide deaths were recorded among 120 231 participants (23.6 per 100 000 person-years): 510 among 70 092 women (17.2 per 100 000 person-years) and 640 among 50 139 men (33.6 per 100 000 person-years). Overall, there was no association of proximity, type of shielding or the occurrence of acute injuries with suicide mortality. Among those <25 years of age at the time of the bombings, increased suicide risk was observed for survivors outside v . shielded inside any structure (HR: 1.24; 95% confidence interval (CI): 1.03, 1.48; interaction p = 0.054) and for those who reported flash burns (HR: 1.32; 95% CI: 1.00, 1.73; interaction p = 0.025). Sex-stratified analyses indicated that these associations were limited to men. Among women, closer proximity to the hypocentre was associated with a non-significant increase in suicide risk, with a positive association between proximity and suicide risk observed among women <15 years of age (HR: 1.09 per km; 95% CI: 1.00, 1.18; interaction p = 0.067). Conclusions Proximity to the hypocentre, shielding and acute injury presence do not generally appear to influence suicide mortality among atomic bomb survivors. However, heterogeneity may exist by age and sex, with younger survivors potentially more sensitive to psychological trauma. Coupled with other studies, our results suggest the importance of long-term monitoring of mental health among young populations exposed to catastrophic events or mass trauma.

Psychiatry↗

Development of a Modular Tissue Phantom for Evaluating Vascular Access Devices

Central vascular access (CVA) may be critical for trauma care and stabilizing the casualty. However, it requires skilled personnel, often unavailable during remote medical situations and combat casualty care scenarios. Automated CVA medical devices have the potential to make life-saving therapeutics available in these resource-limited scenarios, but they must be properly designed. Unfortunately, currently available tissue phantoms are inadequate for this use, resulting in delayed product development. Here, we present a tissue phantom that is modular in design, allowing for adjustable flow rate, circulating fluid pressure, vessel diameter, and vessel positions. The phantom consists of a gelatin cast using a 3D-printed mold with inserts representing vessels and bone locations. These removable inserts allow for tubing insertion which can mimic normal and hypovolemic flow, as well as pressure and vessel diameters. Trauma to the vessel wall is assessed using quantification of leak rates from the tubing after removal from the model. Lastly, the phantom can be adjusted to swine or human anatomy, including modeling the entire neurovascular bundle. Overall, this model can better recreate severe hypovolemic trauma cases and subject variability than commercial CVA trainers and may potentially accelerate automated CVA device development.

59 BASIC BIOLOGICAL SCIENCES↗

Biomedical program at Space Biospheres Ventures

There are many similarities and some important differences between potential health problems of Biosphere 2 and those of which might be anticipated for a space station or a major outpost on Mars. The demands of time, expense, and equipment would not readily allow medical evacuation from deep space for a serious illness or major trauma, whereas personnel can easily be evacuated from Biosphere 2 if necessary. Treatment facilities can be somewhat less inclusive, since distance would not compel the undertaking of heroic measures or highly complicated surgical procedures on site, and with personnel not fully trained for these procedures. The similarities are given between medical requirements of Biosphere 2 and the complex closed ecological systems of biospheres in space or on Mars. The major problems common to all these would seem to be trauma, infection, and toxicity. It is planned that minor and moderate degrees of trauma, including debridement and suturing of wounds, x ray study of fractures, will be done within Biosphere 2. Bacteriologic and fungal infections, and possibly allergies to pollen or spores are expected to be the commonest medical problem within Biosphere 2.

Walford, Roy↗

Neuroendocrine abnormalities in patients with traumatic brain injury

This article provides an overview of hypothalamic and pituitary alterations in brain trauma, including the incidence of hypothalamic-pituitary damage, injury mechanisms, features of the hypothalamic-pituitary defects, and major hypothalamic-pituitary disturbances in brain trauma. While hypothalamic-pituitary lesions have been commonly described at postmortem examination, only a limited number of clinical cases of traumatic hypothalamic-pituitary dysfunction have been reported, probably because head injury of sufficient severity to cause hypothalamic and pituitary damage usually leads to early death. With the improvement in rescue measures, an increasing number of severely head-injured patients with hypothalamic-pituitary dysfunction will survive to be seen by clinicians. Patterns of endocrine abnormalities following brain trauma vary depending on whether the injury site is in the hypothalamus, the anterior or posterior pituitary, or the upper or lower portion of the pituitary stalk. Injury predominantly to the hypothalamus can produce dissociated ACTH-cortisol levels with no response to insulin-induced hypoglycemia and a limited or failed metopirone test, hypothyroxinemia with a preserved thyroid-stimulating hormone response to thyrotropin-releasing hormone, low gonadotropin levels with a normal response to gonadotropin-releasing hormone, a variable growth hormone (GH) level with a paradoxical rise in GH after glucose loading, hyperprolactinemia, the syndrome of inappropriate ADH secretion (SIADH), temporary or permanent diabetes insipidus (DI), disturbed glucose metabolism, and loss of body temperature control. Severe damage to the lower pituitary stalk or anterior lobe can cause low basal levels of all anterior pituitary hormones and eliminate responses to their releasing factors. Only a few cases showed typical features of hypothalamic or pituitary dysfunction. Most severe injuries are sufficient to damage both structures and produce a mixed endocrine picture. Increased intracranial pressure, which releases vasopressin by altering normal hypothalamic anatomy, may represent a unique type of stress to neuroendocrine systems and may contribute to adrenal secretion by a mechanism that requires intact brainstem function. Endocrine function should be monitored in brain-injured patients with basilar skull fractures and protracted posttraumatic amnesia, and patients with SIADH or DI should be closely monitored for other endocrine abnormalities.

NASA Program Space Physiology and Countermeasures↗

Inactivity amplifies the catabolic response of skeletal muscle to cortisol

Severe injury or trauma is accompanied by both hypercortisolemia and prolonged inactivity or bed rest (BR). Trauma and BR alone each result in a loss of muscle nitrogen, albeit through different metabolic alterations. Although BR alone can result in a 2-3% loss of lean body mass, the effects of severe trauma can be 2- to 3-fold greater. We investigated the combined effects of hypercortisolemia and prolonged inactivity on muscle protein metabolism in healthy volunteers. Six males were studied before and after 14 days of strict BR using a model based on arteriovenous sampling and muscle biopsy. Fractional synthesis and breakdown rates of skeletal muscle protein were also directly calculated. Each assessment of protein metabolism was conducted during a 12-h infusion of hydrocortisone sodium succinate (120 microg/kg x h), resulting in blood cortisol concentrations that mimic severe injury (approximately 31 microg/dL). After 14 days of strict BR, hypercortisolemia increased phenylalanine efflux from muscle by 3-fold (P < 0.05). The augmented negative amino acid balance was the result of an increased muscle protein breakdown (P < 0.05) without a concomitant change in muscle protein synthesis. Muscle efflux of glutamine and alanine increased significantly after bed rest due to a significant increase in de novo synthesis (P < 0.05). Thus, inactivity sensitizes skeletal muscle to the catabolic effects of hypercortisolemia. Furthermore, these effects on healthy volunteers are analogous to those seen after severe injury.

Non-NASA Center↗

Prospective Evaluation of Thoracic Ultrasound in the Detection of Pneumothorax

Introduction: Pneumothorax (PTX) occurs commonly in trauma patients and is confirmed by examination and radiography. Thoracic ultrasound (VIS) has been suggested as an alternative method for rapidly diagnosing PTX when X-ray is unavailable as in rural, military, or space flight settings; however, its accuracy and specificity are not known. Methods: We evaluated the accuracy of thoracic U/S detection of PTX compared to radiography in stable, emergency patients with a high suspicion of PTX at a Level-l trauma center over a 6-month period. Following University and NASA Institutional Review Board approval, informed consent was obtained from patients with penetrating or blunt chest trauma, or with a history consistent with PTX. Whenever possible, the presence or absence of the " lung sliding" sign or the "comet tail" artifact were determined by U/S in both hemithoraces by residents instructed in thoracic U/S before standard radiologic verification of PTX. Results were recorded on data sheets for comparison to standard radiography. Results: Thoracic VIS had a 94% sensitivity; two PTX could not be reliably diagnosed due to subcutaneous air; the true negative rate was 100%. In one patient, the VIS exam was positive while X ray did not confirm PTX; a follow-up film 1 hour later demonstrated a small PTX. The average time for bilateral thoracic VIS examination was 2 to 3 minutes. Conclusions: Thoracic ultrasound reliably diagnoses pneumothorax. Presence of the "lung sliding" sign conclusively excludes pneumothorax. Expansion of the FAST examination to include the thorax should be investigated.

Schwarz, K. W.↗

An image classification deep-learning algorithm for shrapnel detection from ultrasound images

Ultrasound imaging is essential for non-invasively diagnosing injuries where advanced diagnostics may not be possible. However, image interpretation remains a challenge as proper expertise may not be available. In response, artificial intelligence algorithms are being investigated to automate image analysis and diagnosis. Here, we highlight an image classification convolutional neural network for detecting shrapnel in ultrasound images. As an initial application, different shrapnel types and sizes were embedded first in a tissue mimicking phantom and then in swine thigh tissue. The algorithm architecture was optimized stepwise by minimizing validation loss and maximizing F1 score. The final algorithm design trained on tissue phantom image sets had an F1 score of 0.95 and an area under the ROC curve of 0.95. It maintained higher than a 90% accuracy for each of 8 shrapnel types. When trained only on swine image sets, the optimized algorithm format had even higher metrics: F1 and area under the ROC curve of 0.99. Overall, the algorithm developed resulted in strong classification accuracy for both the tissue phantom and animal tissue. This framework can be applied to other trauma relevant imaging applications such as internal bleeding to further simplify trauma medicine when resources and image interpretation are scarce.

59 BASIC BIOLOGICAL SCIENCES↗