Search NASA⌕ Search

SEARCH · Search NASA

Results for “TREAT REACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Initial Neutronics Analyses for HEU to LEU Fuel Conversion of the Transient Reactor Test Facility (TREAT) at the Idaho National Laboratory

The purpose of the TREAT reactor is to generate large transient neutron pulses in test samples without over-heating the core to simulate fuel assembly accident conditions. The power transients in the present HEU core are inherently self-limiting such that the core prevents itself from overheating even in the event of a reactivity insertion accident. The objective of this study was to support the assessment of the feasibility of the TREAT core conversion based on the present reactor performance metrics and the technical specifications of the HEU core. The LEU fuel assembly studied had the same overall design, materials (UO 2 particles finely dispersed in graphite) and impurities content as the HEU fuel assembly. The Monte Carlo N–Particle code (MCNP) and the point kinetics code TREKIN were used in the analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Analysis of Damage to MPFDs Caused by Reactor Pulses

The need for next-generation, accident-tolerant fuels has generated significant interest in the restart of domestic fuels testing at the Transient Reactor Test (TREAT) facility. The TREAT reactor is designed to produce large, transient fluxes that replicate the effects of a wide variety of accident conditions on an irradiated fuel sample. Peak powers generated during short pulses approach 20 GW with a neutron flux of approximately 10{sup 17} n cm{sup -2} s{sup -1}. As part of the restart effort, new vehicle designs are being explored for sample irradiation, including the Static Environment Rodlet Transient Test Apparatus (SERTTA) and variants. As part of the SERTTA designs, micro-pocket fission detectors (MPFDs) are being explored for localized flux measurements before, during, and after transient operations. These detectors are also being considered as part of future, core-wide instrumentation for the TREAT reactor. However, the high fluxes associated with the pulses in the TREAT core present certain thermodynamic concerns given their intensity and the amount of energy they will release within the MPFDs within such a short amount of time. Assuming each fission that occurs in a MPFD results in a fission fragment depositing 85 MeV of energy in the substrate on average and each MPFD has 0.5 μg of natural uranium deposited on it, a 100 ms long pulse in the TREAT reactor at 1017 n cm{sup -2} s{sup -1} flux will produce approximately 4.6 x 10{sup 6} fissions in an MPFD. This pulse deposits 6.3 x 10{sup -5} J in the substrate over a 100 ms duration. That amount of energy is sufficient to melt roughly 33% of the Pt under the UO{sub 2} deposition or a circular spot with a diameter of approximately 860 μm. Of course, the above estimate makes a number of simplifying assumptions and ignores heat transfer, but does serve to illustrate the point that this rapid heating effect could be detrimental to the integrity and life of these in-core MPFDs. To study how these layers are affected by large transient neutron fluxes, five samples were prepared, pre-analyzed, and then subjected to a pulse in the central thimble of the Kansas State University TRIGA Mark II reactor to a peak power of 1.58 GW. After being allowed to decay to safer radiation levels, the sample substrates and coatings were inspected using scanning electron microscopy (SEM) to identify any changes to their surface morphology. Indeed, certain changes were found and are discussed in greater detail in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cultural Resource Investigations for the Resumption of Transient Testing of Nuclear Fuels and Material at the Idaho National Laboratory

The U. S. Department of Energy (DOE) has a need to test nuclear fuels under conditions that subject them to short bursts of intense, high-power radiation called ‘transient testing’ in order to gain important information necessary for licensing new nuclear fuels for use in U.S. nuclear power plants, for developing information to help improve current nuclear power plant performance and sustainability, for improving the affordability of new generation reactors, for developing recyclable nuclear fuels, and for developing fuels that inhibit any repurposing into nuclear weapons. To meet this mission need, DOE is considering alternatives for re-use and modification of existing nuclear reactor facilities to support a renewed transient testing program. One alternative under consideration involves restarting the Transient Reactor Test (TREAT) reactor located at the Materials and Fuels Complex (MFC) on the Idaho National Laboratory (INL) site in southeastern Idaho. This report summarizes cultural resource investigations conducted by the INL Cultural Resource Management Office in 2013 to support environmental review of activities associated with restarting the TREAT reactor at the INL. These investigations were completed in order to identify and assess the significance of cultural resources within areas of potential effect associated with the proposed action and determine if the TREAT alternative would affect significant cultural resources or historic properties that are eligible for nomination to the National Register of Historic Places. No archaeological resources were identified in the direct area of potential effects for the project, but four of the buildings proposed for modifications are evaluated as historic properties, potentially eligible for nomination to the National Register of Historic Places. This includes the TREAT reactor (building #), control building (building #), guardhouse (building #), and warehouse (building #). The proposed re-use of these historic properties is consistent with original missions related to nuclear reactor testing and is expected to result in no adverse effects to their historic significance. Cultural resource investigations also involved communication with representatives from the Shoshone-Bannock Tribes to characterize cultural resources of potential tribal concern. This report provides a summary of the cultural resources inventoried and assessed within the defined areas of potential effect for the resumption of transient testing at the INL. Based on these analyses, proposed activities would have no adverse effects on historic properties within the APEs that have been defined. Other archaeological resources and cultural resources of potential concern to the Shoshone-Bannock Tribes and others that are located near the APEs are also discussed with regard to potential indirect impacts. The report concludes with general recommendations for measures to reduce impacts to all identified resources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Baseline Radiological Conditions for the Transient Reactor Test (TREAT) Restart

The Transient Reactor Test (TREAT) facility, located on the Idaho National Laboratory (INL), northwest of the Materials and Fuels Complex (MFC), has been in programmatic shutdown for more than twenty-three years. Construction of TREAT by the Teller Construction Co., Portland, Oregon, was started in February, 1958, and completed in early November, 1958. The reactor first achieved criticality on February 23, 1959. Operations continued until April 28, 1994, when the reactor was shut down due to the lack of a programmatic mission. Recently, the U.S. Department of Energy (DOE) identified a need to resume transient testing of new reactor fuels. The Resumption of Transient Testing Program (RTTP) has readied the TREAT facility to resume transient testing operations. The first reactor criticality since the shut down in 1994 was achieved on November 14, 2017. This report details the radiological measurements taken in the TREAT Reactor Building and the surrounding environment prior to and just after its restart in order to characterize the radiological conditions that existed prior to and during the initial restart operations. The authors would like to acknowledge the support from RTTP Management and the TREAT Operations staff for allowing the extensive radiological surveys, as well as the health physics technicians from the INL Radiological Control organization who performed many of the measurements referenced in this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhancements to the New TREAT Automatic Reactor Control System (ARCS)

The Transient Reactor Test (TREAT) facility recently replaced the automatic reactor control system (ARCS). Here, this paper discusses some of the enhancements that were made during the ARCS replacement such as calculations to take into account the nonadiabatic effects and increasing the dynamic range for power and period indication. This paper also discusses upgrades that had been planned but were unable to implemented and potential upgrades for the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reactivation of the Transient Reactor Test (TREAT) Facility Neutron Radiography Program

Reactivation of the Transient Reactor Test (TREAT) Facility Neutron Radiography Program The Transient Reactor Test (TREAT) Facility is a 19,000 MW reactor located at the Idaho National Laboratory designed to perform transient testing on nuclear fuel experiments and materials. A neutron radiography facility was installed with the first radiograph being produced in 1967 that utilized the indirect (or transfer) method of neutron radiography to examine irradiated nuclear fuels and experiment test loops. The TREAT neutron radiography facility performed approximately 5,000 radiographs by the spring of 1977. The original radiography facility was upgraded in 1974-1975 to correct previous deficiencies and to improve capabilities. In 1986, an upgraded aperture was installed to increase the resolution of images followed by a major reactor upgrade completed in 1988. Overall, the existing neutron radiography system was in good working order. Originally built in 1958, the TREAT Facility was in operation until it was placed in a shutdown status in 1994. Following the Fukishima disaster and seeing a need for enhanced accident tolerant fuels, the United Stated Department of Energy decided to restart the TREAT facility and resume transient operations. In November 2017, the TREAT reactor was successfully restarted and is currently performing operational testing in preparation for initial experiment irradiations and transient testing. This paper reports on efforts to reactivate the TREAT neutron radiography station. A few minor shielding and system improvement upgrades have been completed along with the installation of a dedicated room for computed radiography equipment. Detailed beam characterization work was not performed following the last reactor upgrade. To characterize the neutron beam, gold foil activation measurements were made to determine an average neutron flux and flux profile. Additional multi-foil activation measurements will be made to calculate the energy spectrum. An open beam image will be taken that will provide the information about variations in the beam profile. A series of system qualification shots will also take place to accurately determine the effective image quality and image acquisition parameters. Full operational status of the TREAT neutron radiography system is scheduled for late summer of 2018.

36 MATERIALS SCIENCE↗

TREAT Transient Test Reactor Restart Status

Transient testing involves placing nuclear fuel or material into the core of a nuclear reactor designed to operate at high power for a short time, and subjecting the nuclear fuel or material to short bursts of intense, high power radiation. After the experiment is completed, the fuel or material is analyzed to determine the effects of the radiation. The results are then used in fuel or material design and/or qualification. Transient testing is required for essentially all nuclear fuel design and qualification efforts to learn how nuclear fuel will respond during accidents involving transient overpower and/or under cooling events. For example, nuclear fuel may fragment when exposed to higher than normal power. This fragmentation can cause unacceptable performance. Transient testing is also needed to validate performance models for nuclear fuel and materials. These models, when validated, will dramatically shorten the development and qualification life cycle for nuclear fuels, supporting rapid development of low emissions, reliable power generation. In the past, transient testing was primarily done in facilities that no longer exist. The U.S. Department of Energy evaluated how to provide the required transient testing capability and, following completion of the National Environmental Policy Act process, they selected the Transient Reactor Test (TREAT) facility to resume transient testing. TREAT is located at Idaho National Laboratory (INL). The TREAT reactor was used from 1959 to 1994 to conduct more than 2,500 nuclear fuel transient tests, and was placed in standby in 1994. TREAT is capable of transients in excess of 19 GW. The paper describes the progress towards restart. The restart efforts have revealed that the plant fuel and equipment is acceptable for future operations. The safety basis development, procedures, and training are well under way. Experiment capability preparations are in progress. Reactor startup is anticipated no later than 2018. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

INL transient reactor restart progress

The United States Department of Energy (DOE) has authorized resumption of transient testing and the restart of the Transient Reactor Test (TREAT) facility. The TREAT reactor was used from 1959 to 1994 to conduct more than 2800 nuclear fuel transient tests prior to being placed in standby in 1994. The plant was extensively upgraded shortly before it was placed in standby. Present day assessments revealed that a sound infrastructure remains at the plant. The assessments included extensive walk-downs and subsequent functional testing. The testing was broad in scope, but ensured that any plant operability issues, including age related degradation were discovered and resolved. The primary age related degradation found was capacitors in Reactor Trip System and Automatic Reactor Control System power supplies. The majority of low voltage power supplies required replacement. Although minimal degradation was evident, in some cases elastomers such as hydraulic hoses were preemptively replaced to take advantage of the existing maintenance window and ensure future reliable operation. Configuration management has been extensively reviewed and the plant components re-labeled using modern standards. The re-labeling required extensive work including updates to plant drawings and procedures. The plant organization has been established to restart the reactor and will subsequently seamlessly transition to reactor operations. For the restart effort, the operating organization is being supplemented by subcontractors including some personnel who were involved in TREAT historical operations. During 2015 and the first half of 2016 substantial progress has been made to renew reactor systems and infrastructure, update procedures and configuration management documents, and put in place a qualified operating organization. Reactor startup is anticipated no later than 2018. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of Subdivided Versus Full-Length Fuel Pin Burnup in the ATF-2 Safety Analysis

The Accident Tolerant Fuels (ATF) campaign, under the Fuel Cycle Research and Development (FCRD) Advanced Fuels program, was developed after the Fukushima Daiichi Nuclear Power Plant disaster in 2011. Under ATF, fuel and cladding concepts are to be developed and tested that may more readily withstand an accident similar to the one that occurred at Fukushima Daiichi. ATF is a combination of industry, universities, and national laboratories in an effort to develop advanced accident tolerant cladding and fuel concepts. The end goal of the ATF program is to insert a lead test rod (LTR) or lead test assembly (LTA) into an operating commercial power light water reactor by 2022. In order to meet this 2022 insertion goal, ATF is split into three separate phases: ATF-1, ATF-2, and ATF-3. The first phase of the ATF program, ATF-1, is the concept feasibility study and early irradiation testing. Feasibility, fabrication, and out-of-pile testing are happening at universities and laboratories all over the United States. Irradiation testing of these concepts is happening at the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). Early irradiation testing involves testing clad and/or fuel in drop-in capsules in the ATR. Currently, these capsules are in the relatively low-flux positions in the ATR, but some newer concepts and concepts that require higher burnup will be moved to the higher-flux positions later on during irradiation. Currently, Oak Ridge National Laboratory (ORNL), Westinghouse Electric Company, Areva, and General Electric (GE) have inserted capsules for ATF-1, although more concepts are planned. The second phase of ATF, ATF-2, is the focus of this paper. ATF-2 is the loop testing of fuel pins with new cladding and fuel concepts to simulate pressurized water reactor (PWR) and boiling water reactor (BWR) environments. ATF-2 will concurrently be happening at the ATR and at the Halden Reactor in Norway. The ATF-2 irradiation at the ATR will only simulate a PWR environment. ATF-2 will be inserted into the ATR pressurized water loop, Loop 2A, in the Center Flux Trap (CFT), where chemistry, temperature, and pressure can all be controlled separately from the primary coolant system and other loops in ATR. Loop 2A will be borated, pressurized to 2200 psi nominal, and have an average water temperature of 300 deg. C. A borated loop with fueled rodlets is extremely rare for Nuclear Energy experiments in the ATR, so ATF-2 will demonstrate new and unique capabilities for INL. ATF-3 is the testing of fresh and irradiated ATF concepts at the Transient Reactor Test (TREAT) Facility. The TREAT Reactor is planned for restart, re-establishing U.S. transient testing capabilities after nearly 20 years of non-operations. TREAT will test ATF concepts under transient conditions, such as a reactivity insertion accident. In addition to fresh fuel pins, TREAT will use from ATF2 and do transient testing on those irradiated pins. The information TREAT will provide to the vendors to support fuel licensing will be valuable, showing that these concepts do enhance the accident tolerance of the fuel in commercial reactors. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Safety Analysis Challenges With Restart of the Idaho National Laboratory (INL) Transient Reactor Test (TREAT) Facility

Safety Analysis Challenges With Restart of the Idaho National Laboratory Transient Reactor Test (TREAT) Facility Dr. James Parry David Broussard Anthony LaPorta Douglas Gerstner Battelle Energy Alliance Idaho National Laboratory P.O. Box 1625/MS6194 Idaho Falls, ID 83415 The Transient Reactor Test Facility, commonly referred to as TREAT, is an air-cooled, thermal spectrum test reactor facility designed to: • Induce intense fission heating in the nuclear fuel being tested. • Test nuclear reactor fuels under severe reactor-accident conditions. • Study fuel meltdowns, metal-water reactions, interactions between overheated fuel and coolant, and the transient behavior of fuels for high-temperature systems. • Provide nondestructive test data through neutron radiography of fuel samples. • Allow for the detailed monitoring of the experiments during the test. TREAT was specifically designed to test prototypic-sized reactor fuel pins and bundles under transient power conditions. During its 35 year operating history, it conducted thousands of transient experiments. Today, these capabilities are required for predicting safety margins for next generation fuels and advanced reactor design safety. Even though TREAT has not operated since 1994, return to operable conditions and resumption of testing will occur in FY 2018. This paper discusses the unique challenges with performing and documenting the safety analyses that demonstrate that the TREAT restart may be performed safely. This includes a discussion of 1) the TREAT capability, design, and operations, 2) identification of the format and content of the required safety basis document changes, and 3) demonstration that the consequences of potential accidents during TREAT operations meet the consequence guidelines.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Conceptual Phase Neutronic and Thermal Analyses for the LEU Conversion of the Transient Reactor Test Facility (TREAT)

The Transient Reactor Test Facility (TREAT) is an experimental reactor designed for transient testing of nuclear reactor fuels and other materials. TREAT is located at the Idaho National Laboratory (INL). It was operated from 1959 until 1994, when it was placed on nonoperational standby. Preparations for the restart of TREAT are now underway. Simultaneously, work is being performed to support the conversion of TREAT from its current high enriched uranium (HEU) fuel to low enriched uranium (LEU, defined as uranium with less than 20% {sup 235}U) fuel, under the support of the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Material Management and Minimization (M{sup 3}) reactor conversion program. Following the pre-conceptual phase of the TREAT conversion project (which included assessments of conversion feasibility, including LEU fuel element fabrication feasibility), conceptual phase work was performed to evaluate potential LEU fuel element designs for TREAT. Simultaneously, activities including scale-up development work for fuel fabrication and mock-up element production were performed by the INL Fuel Engineering and Design (FED) team. Utilizing the lessons learned in the analysis and fabrication work, an LEU conceptual design description was collaboratively established and evaluated in detail. A summary of this work and corresponding example results are presented here. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Identification and Evaluation for Fueling of NRIC DOME Reactors Report

The National Reactor Innovation Center (NRIC) has designed a testbed for advanced microreactor experiments that enables and encourages technology developers to bring advanced designs closer to commercial availability. The test bed, Demonstration of Microreactor Experiments (DOME), will be used to facilitate much of the operation experimentation process of the each advanced microreactor including fueling and operational power experiments. This report identifies and evaluates the options for initial fueling the microreactors in DOME. This report also discusses the optional locations that were considered for the initial fueling of microreactor; namely the Transient Reactor Test (TREAT) reactor building, and an unspecified temporary location. But various logistical and construction issues essentially eliminated these other options from further consideration. A brief discussion in this report outlines potential equipment and protocol associated with fueling in DOME.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spark Plasma Sintering (SPS) Update for the Fuel Conversion Effort at the Transient Reactor Test Facility

Over the lifetime of the Transient Reactor Test Facility (TREAT) reactor from 1959 to 1994, a series of historical tests disclosed certain material specific requisites for irradiation testing variables resulted in negligible structural damage after exposure to the reactor and multiple experiments. Comparable fuel design, material testing, and qualifications needs to occur for the high-enriched uranium (HEU) to low enriched uranium (LEU) fuel conversion (<20% U235) of TREAT. This includes, retaining a uniform precipitate dispersion of fueled UO2 micron-size particles throughout a graphite-moderating matrix, where high-density graphite is in direct contact with the fuel and acts as a moderator. On that note, the design of future LEU reactor TREAT fuel core will consider the relative sizing and spacing of fuel as well as the retention of graphite in accordance with the expected thermal, neutron, and energy portfolio for future conversion. In light of the above, LEU conversion fuel blocks currently being manufactured must undergo critical materials testing, irradiation, and examination to determine effects on the manufactured replacement fuel blocks at the millimeter to sub-micron size scale. Herein, we will report and update the community on value-added studies focusing on spark plasma sintering as an alternative technique to fabricate high density graphite dispersion fuel.

36 MATERIALS SCIENCE↗

Development of Electrical Capacitance Sensors for Accident Tolerant Fuel (ATF) Testing at the Transient Reactor Test (TREAT) Facility

A variety of instruments are being developed and qualified to support the Accident Tolerant Fuels (ATF) program and future transient irradiations at the Transient Reactor Test (TREAT) facility at Idaho National Laboratory (INL). The University of New Mexico (UNM) is working with INL to develop capacitance-based void sensors for determining the timing of critical boiling phenomena in static capsule fuel testing and the volume-averaged void fraction in flow-boiling in-pile water loop fuel testing. The static capsule sensor developed at INL is a plate-type configuration, while UNM is utilizing a ring-type capacitance sensor. Each sensor design has been theoretically and experimentally investigated at INL and UNM. Experiments are being performed at INL in an autoclave to investigate the performance of these sensors under representative Pressurized Water Reactor (PWR) conditions in a static capsule. Experiments have been performed at UNM using air-water two-phase flow to determine the sensitivity and time response of the capacitance sensor under a flow boiling configuration. Initial measurements from the capacitance sensor have demonstrated the validity of the concept to enable real-time measurement of void fraction. The next steps include designing the cabling interface with the flow loop at UNM for Reactivity Initiated Accident (RIA) ATF testing at TREAT and further characterization of the measurement response for each sensor under varying conditions by experiments and modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutronics and Transient Calculations for the Conversion of the Transient Reactor Rest Facility (TREAT)

The Transient Reactor Test Facility (TREAT) is a graphite-reflected, graphitemoderated, and air-cooled reactor fueled with 93.1% enriched UO2 particles dispersed in graphite, with a carbon-to-235U ratio of ~10000:1. TREAT was used to simulate accident conditions by subjecting fuel test samples placed at the center of the core to high energy transient pulses. The transient pulse production is based on the core’s selflimiting nature due to the negative reactivity feedback provided by the fuel graphite as the core temperature rises. The analysis of the conversion of TREAT to low enriched uranium (LEU) is currently underway. This paper presents the analytical methods used to calculate the transient performance of TREAT in terms of power pulse production and resulting peak core temperatures. The validation of the HEU neutronics TREAT model, the calculation of the temperature distribution and the temperature reactivity feedback as well as the number of fissions generated inside fuel test samples are discussed.

Kontogeorgakos, Dimitrios C.↗

MCNP6 simulated performance of Micro-Pocket Fission Detectors (MPFDs) in the Transient REActor Test (TREAT) Facility

Micro-Pocket Fission Detectors (MPFDs) are under development for in-core neutron flux measurements at the Transient REActor Test facility (TREAT) and in other experiments at Idaho National Laboratory (INL). The sensitivity of MPFDs to the energy dependent neutron flux at TREAT has been determined for 0.0300-μm thick active material coatings of 242 Pu, 232 Th, natural uranium, and 93% enriched 235 U. Self-shielding effects in the active material of the MPFD was also confirmed to be negligible. Lastly, fission fragment energy deposition was found to be in conformance with previously reported results.

36 MATERIALS SCIENCE↗

Evaluation of Optical Fiber Bragg Gratings in a Nuclear Reactor

Optical fiber-based sensors are capable of distributed temperature and/or strain measurements with high accuracy and sub-cm spatial resolution. Optical fibers have a small diameter ({approx}100 {mu}m), a small mass (and therefore fast response time), and are fabricated from high temperature-tolerant, radiation-hard materials. These qualities make optical fiber-based instrumentation a promising candidate for in-pile sensing applications, monitoring fuel performance during irradiation in test reactors, or embedding fibers in other commercial reactor components or structures. The Department of Energy and Idaho National Laboratory are restarting the TREAT reactor (Transient Reactor Test facility) and are interested in updating the reactor's instrumentation regarding the analysis of the test fuel. The ability of optical fibers to make distributed temperature measurements coupled with its small footprint makes optical fiber a viable candidate to monitor fuel performance in the TREAT reactor. The work presented in this paper focuses on the radiation hardness of various types of optical fiber Bragg gratings. Previous experiments have shown that the inscription of Bragg gratings into optical fiber can extend the radiation survivability of distributed sensing in optical fibers, and so the goal is to determine which types of Bragg gratings survive the best in a reactor environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗