Search NASA⌕ Search

SEARCH · Search NASA

Results for “TUBING, RECTANGULAR - STRENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Numerical and Experimental Dynamic Characteristics of Thin-Film Membranes

Presented is a total-Lagrangian displacement-based non-linear finite-element model of thin-film membranes for static and dynamic large-displacement analyses. The membrane theory fully accounts for geometric non-linearities. Fully non-linear static analysis followed by linear modal analysis is performed for an inflated circular cylindrical Kapton membrane tube under different pressures, and for a rectangular membrane under different tension loads at four comers. Finite element results show that shell modes dominate the dynamics of the inflated tube when the inflation pressure is low, and that vibration modes localized along four edges dominate the dynamics of the rectangular membrane. Numerical dynamic characteristics of the two membrane structures were experimentally verified using a Polytec PI PSV-200 scanning laser vibrometer and an EAGLE-500 8-camera motion analysis system.

Young, Leyland G.↗

Radiator Design and Installation

The fundamental principles of fluid flow, pressure losses, and heat transfer have been presented and analyzed for the case of a smooth tube with fully developed turbulent flow. These equations apply to tubes with large length-diameter ratios where the f1ow is at a high Reynolds Number. The error introduced by using these equations increases as the magnitude of the tube length and the air-flow Reynolds Number approaches the values encountered in modern radiator designs. Accordingly, heat-transfer tests on radiator sections were made and the results are presented in nondimensional form to facilitate their use and for comparison with other heat-transfer data. In addition, pressure losses were measured along smooth tubes of circular, square, and rectangular cross section and the results were also correlated and are presented in nondimensional form. The problem of a radiator design for a particular installation is solved, the experimental heat-transfer and pressure-loss data being used, on a basis of power chargeable to the radiator for form drag, for propelling the weight, and for forcing the air through the radiator. The case of an installation within a wing or an engine nacelle is considered. An illustration of radiator design is carried through for an arbitrary set of conditions. Sufficient detail is given to enable the reader to reproduce the analysis for any given case.

Brevoort, M.J.↗

RUScal : Software for the analysis of resonant ultrasound spectroscopy measurements

Resonant ultrasound spectroscopy is used to nondestructively measure the elastic resonances of small solids to elucidate the material's elastic properties or other qualities like size, shape, or composition. In this work, we introduce the software RUScal for the purpose of determining elastic properties by analyzing the eigenfrequencies of solid specimens with common shapes, such as rectangular parallelepipeds, cylinders (solid and hollow tube), ellipsoids, and octahedrons, as well as irregularly shaped ellipsoids that can be described analytically. All symmetry classes are supported, from isotropic to triclinic, along with the option to add or remove up to three orthogonal mirror planes as well as the ability to reorient the crystal axes with respect the sample edges via Euler angles. Additional features include tools to help find initial sets of elastic constants, including grid exploration and Monte Carlo methods, a tool to analyze frequencies as a function of sample length or crystal orientation, an error analysis tool to assess fit quality, and formatting of the input and output files for batch fitting, e.g., as a function of temperature. This software was validated with published resonant ultrasound spectroscopy data for various materials, shapes, and symmetries with noted improvements in calculation time compared to finite element methods.

47 OTHER INSTRUMENTATION↗

Application of Variational Methods to the Thermal Entrance Region of Ducts

A variational method is presented for solving eigenvalue problems which arise in connection with the analysis of convective heat transfer in the thermal entrance region of ducts. Consideration is given, to both situations where the temperature profile depends upon one cross-sectional coordinate (e.g. circular tube) or upon two cross-sectional coordinates (e.g. rectangular duct). The variational method is illustrated and verified by application to laminar heat transfer in a circular tube and a parallel-plate channel, and good agreement with existing numerical solutions is attained. Then, application is made to laminar heat transfer in a square duct as a check, an alternate computation for the square duct is made using a method indicated by Misaps and Pohihausen. The variational method can, in principle, also be applied to problems in turbulent heat transfer.

Sparrow, E. M.↗

Velocity Vector Field Visualization of Flow in Liquid Acquisition Device Channel

A capillary flow liquid acquisition device (LAD) for cryogenic propellants has been developed and tested in NASA Glenn Research Center to meet the requirements of transferring cryogenic liquid propellants from storage tanks to an engine in reduced gravity environments. The prototypical mesh screen channel LAD was fabricated with a mesh screen, covering a rectangular flow channel with a cylindrical outlet tube, and was tested with liquid oxygen (LOX). In order to better understand the performance in various gravity environments and orientations at different liquid submersion depths of the screen channel LAD, a series of computational fluid dynamics (CFD) simulations of LOX flow through the LAD screen channel was undertaken. The resulting velocity vector field visualization for the flow in the channel has been used to reveal the gravity effects on the flow in the screen channel.

McQuillen, John B.↗

Heat Pipe Heat Exchanger for Nuclear Electric Propulsion Power Conversion System

Heat pipe reactors have been considered by the Space Nuclear Propulsion program for Nuclear Electric Propulsion (NEP) power conversion systems and will require the use of heat exchangers to transfer heat via heat pipes to the Brayton working fluid from the reactor. Sodium (Na) and lithium (Li) were considered as viable working fluids inside the heat pipes which were assumed to have the same geometry based on studies and information from the Los Alamos National Laboratory. The heat exchanger was assumed to be a rectangular duct with heat pipes serving as tubes from previous NEP work and recommendations. Based on this geometry, Zukauskas correlations were used to model the convective heat transfer and pressure losses. Parametric sizing of the reactor component involved operational limits-based heat pipe thermal hydraulic modeling in cohesion with required user input geometry for the in-core lattice and various subcomponents. This work considered various power conversion inlet temperatures (PCIT) of 1100 K, 1150 K, and 1200 K for Na heat pipes and 1100 K, 1150 K, 1200 K, and 1400 K for Li heat pipes based on recommendations from prior work. Using these different PCITs, the subsystem masses and pressure losses were determined and analyzed. Na showed a lower overall operating temperature and about a fifth of the maximum heat throughput capability than that of Li for the same geometry. Due to this, the entire Na-based subsystem ended up being three times more massive than the Li-based subsystem given five times the required number of heat pipes. At the low PCIT of 1100 K, the Na-based subsystem exhibited the lowest pressure losses given the large overall cross sectional flow area and relatively low frictional pressure losses. However, as the PCIT increased, the frictional pressure losses increased resulting in higher pressure losses at the 1200 K PCIT than Li-based subsystem. However, the Li-based subsystem exhibited the largest pressure losses of all analyzed cases at the 1400 K PCIT due to the low density of the Brayton working fluid at this temperature.

electric↗

Surface Roughness Effects on Heat Transfer in Additively Manufactured sCO 2 Cycle Heat Exchangers

An experimental study was performed to consider the impact of surface roughness on heat transfer and pressure drop to supercritical carbon dioxide (sCO 2 ) in additively manufactured channels. All tests were performed in the Heat Exchange and Experimental Testing (HEET) rig at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia. Four test articles were considered. The first was a hydrodynamically smooth, drawn tube. The other three were additively manufactured channels with square and rectangular cross sections, which were characterized by sand-grain roughness to hydraulic diameter ratios spanning 0.0029 to 0.0073. Friction factors were determined by measuring the tube mass flow rate and pressure drop. The tube side heat transfer coefficient was measured using the Wilson plot technique. It was found that the friction factor results were 8% greater than the Colebrook correlation. Greater deviation was observed between the heat transfer results and the correlations. The Gnielinski correlation overpredicted the experimental points by nominally 30% and the Norris correlation overpredicting the experimental points by nominally 25%. A thermal performance factor was formed from the friction factor augmentation and Nusselt number augmentation results. These results indicated a 10% improvement in heat duty for a heat exchanger constructed utilizing a tube with ϵ/D_h =0.0073 relative to a heat exchanger utilizing a smooth, conventional tube.

36 MATERIALS SCIENCE↗

The Effect of Cooling Passage Aspect Ratio on Curvature Heat Transfer Enhancement

A series of electrically heated tube experiments was performed to investigate the effect of high aspect ratio on curvature heat transfer enhancement in uniformly heated rectangular cooling passages. Three hardware geometries were tested: a baseline straight aspect ratio 10 tube, an aspect ratio 1 (square) tube with a 45 deg. curve, and an aspect ratio 10 tube with a 45 deg. curve. Gaseous nitrogen with the following properties was used as the coolant: ambient inlet temperature, pressures to 8.3 MPa, wall-to-bulk temperature ratios less than two, and Reynolds numbers based on hydraulic diameter ranging from 250,000 to 1,600,000. The measured curvature enhancement factors were compared to values predicted by three previously published models which had been developed for low aspect ratio tubes. The models were shown to be valid for the high aspect ratio tube as well the low aspect ratio tube, indicating that aspect ratio had little impact on the curvature heat transfer enhancement in these tests.

Meyer, Michael L.↗

A multi-channel coronal spectrophotometer.

We describe a new multi-channel coronal spectrophotometer system, presently being installed at Mees Solar Observatory, Mount Haleakala, Maui. The apparatus is designed to record and interpret intensities from many sections of the visible and near-visible spectral regions simultaneously, with relatively high spatial and temporal resolution. The detector, a thermoelectrically cooled silicon vidicon camera tube, has its central target area divided into a rectangular array of about 100,000 pixels and is read out in a slow-scan (about 2 sec/frame) mode. Instrument functioning is entirely under PDP 11/45 computer control, and interfacing is via the CAMAC system.

Landman, D. A.↗

Hot-Gas Nozzle for Desoldering Leadless IC's

Simple hand-held tool removes leadless, surface-mounted integrated circuits (IC's) from printed-circuit boards. Nozzle used with hot-air gun of type used to apply heat-shrink tubing or with some other source of hot gas. Rectangular end of nozzle and deflector shape airflow pattern to concentrate heat directly on soldering pads located around edge of IC's to heat them quickly and uniformly.

Hanlon, Mark T.↗

Two-Dimensional Vernier Scale

Modified vernier scale gives accurate two-dimensional coordinates from maps, drawings, or cathode-ray-tube displays. Movable circular overlay rests on fixed rectangular-grid overlay. Pitch of circles nine-tenths that of grid and, for greatest accuracy, radii of circles large compared with pitch of grid. Scale enables user to interpolate between finest divisions of regularly spaced rule simply by observing which mark on auxiliary vernier rule aligns with mark on primary rule.

Juday, Richard D.↗

An experimental study of the Richtmyer-Meshkov instability in microgravity

Richtmyer-Meshkov (RM) instability occurs when a planar interface separating two fluids of different density is impulsively accelerated in the direction of its normal. It is one of the most fundamental fluid instabilities and is of importance to the fields of astrophysics and inertial confinement fusion. Because RM instability experiments are normally carried out in shock tubes, where the generation of a sharp, well-controlled interface between gases is difficult, there is a scarcity of good experimental results. The experiments presented here use a novel technique that circumvents many of the experimental difficulties that have previously limited the study of RM instability in shock tubes. In these experiments, the instability is generated incompressibly, by bouncing a rectangular tank containing two liquids off of a fixed spring. These experiments, which utilize PLIF flow visualization, yield time-motion image sequences of the nonlinear development and transition to turbulence of the instability that are of a quality unattainable in shock tube experiments. Measurements obtained from these images, therefore, provide benchmark data for the evaluation of nonlinear models for the late-time growth of the instability. Because the run time in these experiments is limited, new experiments in the NASA Glenn 2.2 second drop tower, capable of achieving longer run times, are currently under way.

Rheology/methods↗

Scale Model Icing Research Tunnel

NASA Lewis Research Center's Icing Research Tunnel (IRT) is the world's largest refrigerated wind tunnel and one of only three icing wind tunnel facilities in the United States. The IRT was constructed in the 1940's and has been operated continually since it was built. In this facility, natural icing conditions are duplicated to test the effects of inflight icing on actual aircraft components as well as on models of airplanes and helicopters. IRT tests have been used successfully to reduce flight test hours for the certification of ice-detection instrumentation and ice protection systems. To ensure that the IRT will remain the world's premier icing facility well into the next century, Lewis is making some renovations and is planning others. These improvements include modernizing the control room, replacing the fan blades with new ones to increase the test section maximum velocity to 430 mph, installing new spray bars to increase the size and uniformity of the artificial icing cloud, and replacing the facility heat exchanger. Most of the improvements will have a first-order effect on the IRT's airflow quality. To help us understand these effects and evaluate potential improvements to the flow characteristics of the IRT, we built a modular 1/10th-scale aerodynamic model of the facility. This closed-loop scale-model pilot tunnel was fabricated onsite in the various shops of Lewis' Fabrication Support Division. The tunnel's rectangular sections are composed of acrylic walls supported by an aluminum angle framework. Its turning vanes are made of tubing machined to the contour of the IRT turning vanes. The fan leg of the tunnel, which transitions from rectangular to circular and back to rectangular cross sections, is fabricated of fiberglass sections. The contraction section of the tunnel is constructed from sheet aluminum. A 12-bladed aluminum fan is coupled to a turbine powered by high-pressure air capable of driving the maximum test section velocity to 550 ft/sec (Mach 0.45). The air turbine and instrumentation are housed inside a fiberglass nacelle. Total and static pressure measurements can be taken around the loop, and velocity and flow angularity measurements can be taken with hot-wire and five-hole probes at specific locations. The Scale Model Icing Research Tunnel (SMIRT) is undergoing checkout tests to determine how its airflow characteristics compare with the IRT. Near-term uses for this scale-model tunnel include determining the aerodynamic effects of replacing the 52-yearold W-shaped heat exchanger with a flat-faced heat exchanger. SMIRT is an integral part of the improvements planned for the IRT because testing the proposed IRT improvements in a scale-model tunnel will lower costs and improve productivity.

Canacci, Victor A.↗

Clean Electrical-Discharge Machining Of Delicate Honeycomb

Precise recesses in fragile metal honeycomb blocks formed in special electrical-discharge machining process. Special tooling used, and recesses bored with workpiece in nonstandard alignment. Cutting electrode advances into workpiece along x axis to form pocket of rectangular cross section. Deionized water flows from fitting, along honeycomb tubes of workpiece, to electrode/workpiece interface.

Johnson, Clarence S.↗

Method of generation of planar plasma jets

Applications of dielectric barrier discharge (DBD) based atmospheric pressure plasma jets are often limited by the relatively small area of treatment due to their 1D configuration. This system generates 2D plasma jets permitting fast treatment of larger targets. DBD evolution starts with formation of transient anode glow, and continues with development of cathode-directed streamers. The anode glow can propagate as an ionization wave along the dielectric surface through and outside of the discharge gap. Plasma propagation is not limited to 1D geometry such as tubes, and can be organized in a form of a rectangular plasma jet, or other 2D or 3D shapes. Also described are a method for generating 2D plasma jets and use of the 2D plasma jets for cancer therapy.

Dobrynin, Danil V.↗

A computer program for plotting stress-strain data from compression, tension, and torsion tests of materials

A computer program for plotting stress-strain curves obtained from compression and tension tests on rectangular (flat) specimens and circular-cross-section specimens (rods and tubes) and both stress-strain and torque-twist curves obtained from torsion tests on tubes is presented in detail. The program is written in FORTRAN 4 language for the Control Data 6000 series digital computer with the SCOPE 3.0 operating system and requires approximately 110000 octal locations of core storage. The program has the capability of plotting individual strain-gage outputs and/or the average output of several strain gages and the capability of computing the slope of a straight line which provides a least-squares fit to a specified section of the plotted curve. In addition, the program can compute the slope of the stress-strain curve at any point along the curve. The computer program input and output for three sample problems are presented.

Greenbaum, A.↗

Torsion and bending of prismatic rods of hollow rectangular section

The torsion and bending of hollow rectangular beams was investigated without the requirement that wall thickness be small compared with the transverse dimensions. The limits of applicability of the usual Bredt formula are indicated for the case of a square hollow tube in torsion. Formulas are given for bending stresses at different parts of the cross section of a hollow rectangular beam.

BOXES, STRUCTURAL↗

The nonlinear transient response of thin, rectangular elastic plates

The results of experiments and theoretical analysis of the nonlinear, transient response of thin, rectangular, elastic, simply supported plates are presented. In the experiments, a plane wave tube with a special pulse generator at one end and a thin glass plate mounted at the other end was used to subject the glass plate to pressure pulses of different magnitudes. Whole-field measurements of the response of the plate were obtained by the reflected moire grid technique. The largest ratio of center deflection to thickness of the plate during the experiments was 5.6. The theoretical response of the glass plate to the pressure pulses was computed by solving the von Karman equations governing large deflections in elastic plates by two methods - (1) the finite-difference method, and (2) Galerkin's method. Good agreement was found between theoretically predicted and experimentally measured response.

Rajagopal, G.↗