Search NASA⌕ Search

SEARCH · Search NASA

Results for “TUNGSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Investigation of the photoluminescent properties, scintillation behaviour and toxicological profile of various magnesium tungstate nanoscale motifs

We have synthesized several morphologies and crystal structures of MgWO 4 using a one-pot hydrothermal method, producing not only monoclinic stars and large nanoparticles but also triclinic wool balls and sub-10 nm nanoparticles. Herein we describe the importance of reaction parameters in demonstrating morphology control of as-prepared MgWO 4 . Moreover, we correlate structure and composition with the resulting photoluminescence and radioluminescence properties. Specifically, triclinic-phase samples yielded a photoluminescence emission of 421 nm, whereas monoclinic-phase materials gave rise to an emission maximum of 515 nm. The corresponding radioluminescence data were characterized by a broad emission peak, located at 500 nm for all samples. Annealing the wool balls and sub-10 nm particles to transform the crystal structure from a triclinic to a monoclinic phase yielded a radioluminescence (RL) emission signal that was two orders of magnitude greater than that of their unannealed counterparts. Finally, to confirm the practical utility of these materials for biomedical applications, a series of sub-10 nm particles, including as-prepared and annealed samples, were functionalized with biocompatible PEG molecules, and subsequently were found to be readily taken up by various cell lines as well as primary cultured hippocampal neurons with low levels of toxicity, thereby highlighting for the first time the potential of this particular class of metal oxides as viable and readily generated platforms for a range of biomedical applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Oxidation of Cyclopentene with Manganese Oxides Octahedral Molecular Sieves with Layer and Tunnel Structures

We report manganese oxides type octahedral molecular sieves OL-1, OMS-1, and OMS-2 were synthesized, impregnated with sodium tungstate, and evaluated as catalysts for the selective epoxidation of cyclopentene (CPE) to cyclopentene oxide (CPO) in the sodium bicarbonate/hydrogen peroxide (BAP) system. OL-1 was the best catalyst with a conversion of 78.6 % and a selectivity to CPO of 31.4 %. Impregnation with sodium tungstate affected the structure and activity of OL-1 and OMS-1. Mn 2+ is required for the epoxidation of CPE. FTIR spectra provides evidence that tungstate ions react, during impregnation, with Mg 2+ and/or Mn 2+ present in OMS-1 and OL-1 producing an amorphous compound that is not active in the epoxidation reaction. The crystalline and chemical structure of OMS-2 was not affected by tungstate impregnation, since most of the manganese occurs as Mn 3+ and Mn 4+ , which in presence of hydrogen peroxide, tend to form radicals, active in the total oxidation of organic compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decoupling of catalysis and transition state analog binding from mutations throughout a phosphatase revealed by high-throughput enzymology

Using high-throughput microfluidic enzyme kinetics (HT-MEK), we measured over 9,000 inhibition curves detailing impacts of 1,004 single-site mutations throughout the alkaline phosphatase PafA on binding affinity for two transition state analogs (TSAs), vanadate and tungstate. As predicted by catalytic models invoking transition state complementary, mutations to active site and active-site-contacting residues had highly similar impacts on catalysis and TSA binding. Unexpectedly, most mutations to more distal residues that reduced catalysis had little or no impact on TSA binding and many even increased tungstate affinity. These disparate effects can be accounted for by a model in which distal mutations alter the enzyme’s conformational landscape, increasing the occupancy of microstates that are catalytically less effective but better able to accommodate larger transition state analogs. In support of this ensemble model, glycine substitutions (rather than valine) were more likely to increase tungstate affinity (but not more likely to impact catalysis), presumably due to increased conformational flexibility that allows previously disfavored microstates to increase in occupancy. These results indicate that residues throughout an enzyme provide specificity for the transition state and discriminate against analogs that are larger only by tenths of an Ångström. Thus, engineering enzymes that rival the most powerful natural enzymes will likely require consideration of distal residues that shape the enzyme’s conformational landscape and fine-tune active-site residues. Biologically, the evolution of extensive communication between the active site and remote residues to aid catalysis may have provided the foundation for allostery to make it a highly evolvable trait.

59 BASIC BIOLOGICAL SCIENCES↗

Scintillating glass for precision calorimetry in nuclear physics

High-performance scintillator materials are needed for particle identification and measurements of energy and momentum of electromagnetic particles in modern nuclear physics experiments. As an example, the US Electron-Ion Collider, a unique collider with diverse physics topics, requires electromagnetic calorimetry enabling high-quality electron identification and detection in the momentum range of 0.3 to tens of GeV. The highest resolution in electromagnetic calorimeters can be provided by homogeneous materials, e.g., lead tungstate crystals. Inorganic glass scintillators have been investigated as an attractive and cost-effective alternative to crystals, that is also easier and faster to manufacture in mass production. In this paper, we discuss progress in the fabrication and characterization of recent scintillating glass samples on both test bench and beam tests. Further, the results are well-reproduced by simulation and are discussed in the context of the Electron-Ion Collider experimental requirements and bench-marked against lead tungstate crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Origin of tungsten and geochemical controls on its occurrence and mobilization in shallow sediments from Fallon, Nevada, USA

In this study, tungsten (W) occurrence and speciation was investigated in sediments collected from Fallon, Nevada where previous studies have linked elevated W levels in human body fluids to an unusual cluster of childhood leukemia cases. The speciation of sedimentary W was determined by μ-XRF mapping and μ-XANES. The W content of the analyzed surface sediments ranged between 81 and 25,908 mg/kg, which is significantly higher than the W content in deeper sediments which ranged from 37 to 373 mg/kg at 30 cm depth. The μ-XANES findings reveal that approximately 20–50% of the total W in the shallow sediment occurs in the metallic form (W 0 ); the rest occurs in the oxide form (W VI O 3 ). Because W 0 does not occur naturally, its elevated concentrations in surface sediments point toward a possible local anthropogenic origin. The oxidation of metallic W 0 with meteoric waters likely leads to the formation of W VI O 3 . The chief water-soluble W species was identified as WO 4 2– by chromatographic separation and speciation modeling. These results led us to postulate that W 0 particles from a currently unknown but local source(s) is (are) deposited onto the soils and/or surface sediments. The W 0 in interaction with meteoric water is oxidized to W VI O 3 , and as these sediment-water interactions progress, WO 4 2– is formed in the water at pH ~7. Under pH < 7, and sufficient W concentrations, tungstate tends to polymerize, and polymerized species are less likely to adsorb onto sediments. Polymerized species have lower affinity than monomers, which leads to enhanced mobility of W.

58 GEOSCIENCES↗

Radiation hardness characterization of LKH-5 scintillating glass

Radiation hardness is an important property to examine in scintillators to help determine their expected lifetime in application cases where significant radiation dose is expected. Industrial imaging systems using 9 MV linear accelerators for x-ray radiography are one such application where significant radiation doses are expected to the scintillators used. Cadmium tungstate scintillators (CWO) and Thallium doped Cesium Iodide scintillators (CsI(Tl)) are used in some high energy cargo x-ray radiography systems. However, CWO has a high manufacturing cost for adequately uniform crystals and CsI(Tl) does not have sufficient radiation hardness. LKH-5 glass is being investigated as a potential low cost replacement for CWO and CsI(Tl). In this experiment 36 samples of a terbium doped silicate glass called LKH-5 were irradiated at doses up to 5 MRad using a 9 MV linear accelerator, and the change in their transmission properties was observed. Additionally, the glass was discovered to be a radiation hard glass due to the relatively small change in the transmission of the glass: less than 3% per cm at its emission peak of 550 nm and 5 MRad. This is similar to CWO which has a reported reduction in transmitted light of 2% per cm at 5 MRad and the emission peak of 475 nm and better than CsI(Tl) which is reported to have a reduction in transmitted light of 5% per cm at the emission peak of 550 nm and 4.2 MRad dose. Furthermore, an annealing procedure is described that returned the transmission of the glass to pre-irradiation values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of $\text{BDX-MINI}$ veto systems

Here this paper describes the veto system of the BDX-MINI detector installed at Jefferson Lab (US). The BDX-MINI experiment is the first electron beam-dump experiment specifically designed to search for Light Dark Matter (LDM) particles in the MeV-GeV mass range. The core of the BDX-MINI detector is a lead-tungstate electromagnetic calorimeter, for a total volume of 4 dm 3 . The calorimeter is surrounded by a multi-layer veto aimed at rejecting cosmic background: the innermost layer of the veto is made by a passive tungsten shielding for low energy radiation, while plastic scintillators make the middle and outer layers for charged cosmic particles rejection. Being located about 20 m downstream, the dirt between the beam dump and the detector provides sufficient shielding from the beam-related background. In 2019–2020, BDX-MINI was exposed for about six months to weakly interacting particles (neutrinos and, if existing, DM) produced by a 2.176 GeV electron beam incident on the beam dump of experimental Hall-A at Jefferson Lab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling athermal phonons in novel materials using the G4CMP simulation toolkit

Understanding phonon and charge propagation in superconducting devices plays an important role in both performing low-threshold dark matter searches and limiting correlated errors in superconducting qubits. The Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, models charge and phonon transport within silicon and germanium detectors and has been validated by experimental measurements of phonon caustics, mean charge-carrier drift velocities, and heat pulse propagation times. Here, in this work, we present a concise framework for expanding the capabilities for phonon transport to a number of other novel substrate materials of interest to the dark matter and quantum computing communities, including sapphire (Al 2 O 3 ), gallium arsenide (GaAs), lithium fluoride (LiF), calcium tungstate (CaWO 4 ), and calcium fluoride (CaF 2 ). We demonstrate the use of this framework in generating phonon transport properties of these materials and compare these properties with experimentally-determined values where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hard gallium oxide scintillators for high count rate radiation detection

Despite decades of materials research, the availability of appropriate crystalline radiation-hard scintillators with ultrafast decay times (~10ns) and high light yields (>2000 ph/MeV) are still limited. In this study, we demonstrate the potential of gallium oxide (β-Ga 2 O 3 ) based scintillators for high count rate applications. The low-cost rugged β-Ga 2 O 3 scintillators were grown using the optical float zone (FZ) technique. Several dopants and growth atmospheres were used to demonstrate the balance between ultrafast primary decay time and the light yield of the scintillators. Light yields as high as 6446 ± 716 ph/MeV were obtained with 18.3 ns decay time for 662 keV gamma rays. Decay times as fast as 12ns were obtained with a 3212 ± 357 ph/MeV light yield. An excellent 662 keV gamma energy resolution of 7% was obtained using the β-Ga 2 O 3 :Ce crystals. Even with these excellent scintillation properties, the gamma radiation hardness of β-Ga 2 O 3 crystals was better than the leading radiation-hard lead tungstate (PbWO 4 ) crystals. Twenty-six scintillators fabricated from the grown β-Ga 2 O 3 crystals were tested for radiation hardness with a 60 Co gamma irradiation rate of 14 krad/h with a total radiation dose of 2 Mrad. The scintillation properties of these crystals remained unaffected. To date, no other scintillator has demonstrated such high radiation resistance. Furthermore, these FZ-grown low-cost, non-hygroscopic, and high-density β-Ga 2 O 3 scintillators can replace the existing scintillators in many applications ranging from nuclear and high energy physics experiments to nuclear security.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Antioxidant-induced transformations of a metal-acid hydrocracking catalyst in the deconstruction of polyethylene waste

Plastics are ideal for numerous applications, as driven by the development of complex formulations containing various additives to improve performance and processability. Unfortunately, chemical valorization strategies (e.g., catalytic deconstruction) often can be challenged by the presence of small-molecule additives, and quantification of the impact of these molecular constituents on upcycling processes remains elusive. Here, this dearth of information restricts catalyst design efforts to combine the robustness and performance necessary to improve plastics circularity. In this communication, we describe a systematic study of common plastics additives—phenolic antioxidants, and we quantify the relationship between additive content and deconstruction yields of high-density polyethylene (HDPE) over a platinum on tungstated zirconium (Pt/WO 3 /ZrO 2 ) hydrocracking catalyst. In the simplest case of a base (antioxidant- and slip agent-containing) HDPE resin versus a pure (additive-stripped) HDPE polymer, a two-fold decrease in the yield of gas and liquid products is noted for base HDPE resin. Furthermore, both antioxidant chemistry and concentration strongly impact conversion and individual product selectivities. Using infrared spectroscopy, we determine that antioxidants change the effective ratio of metal to acid sites (i.e., metal-acid balance) through reactions of phenols and/or other functional groups (e.g., acids, esters) with catalyst active sites. Overall, this work demonstrates the impact of one common set of additives on plastics deconstruction, and the analysis herein provides a blueprint for quantitatively assessing the effects of additives on plastics deconstruction processes and for evaluating the development of more robust catalytic strategies or more tolerable additive formulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Heavy Photon Search (HPS) Software Environment

The Heavy Photon Search (HPS) is an experiment at the Thomas Jefferson National Accelerator Facility (JLab) designed to search for a hidden sector photon (A’) in fixed-target electro-production. It uses a silicon microstrip tracking and vertexing detector placed inside a dipole magnet to measure charged particle trajectories and a fast lead-tungstate crystal calorimeter located just downstream of the magnet to provide a trigger and to identify electromagnetic showers. The HPS experiment uses both invariant mass and secondary vertex signatures to search for the A’. The experimental collaboration is small and quite heterogeneous: it is composed of members of the nuclear physics as well as particle physics communities, from universities and national labs from around the US and Europe. Enabling such a disparate group to concentrate on the physics aspects of the experiment required that the software be easy to install and use, and having such limited manpower meant that existing solutions had to be exploited. HPS has successfully completed two engineering runs and completed its first physics run in the summer of 2019. We begin with an overview of the physics goals of the experiment followed by a short description of the detector design. We then describe the software tools used to design the detector layout and simulate the expected detector performance. Event reconstruction involving track, cluster and vertex finding and fitting for both simulated and real data was, to first order, adopted from existing software originally developed for Linear Collider studies. Bringing it all together into a cohesive whole involved the use of multiple software solutions with common interfaces.

Graf, Norman↗

Tungsten enzymes play a role in detoxifying food and antimicrobial aldehydes in the human gut microbiome

Significance The diverse microorganisms contained within the human gut are known to have significant effects on human health. Herein, we show that genes encoding members of the tungsten oxidoreductase (WOR) family of enzymes and a tungstate-specific transporter are prevalent in the human gut microbiome and metagenome. We demonstrate that two model gut microbes assimilate tungsten into multiple WOR enzymes and that some of these enzymes catalyze the conversion of gut aldehydes to the corresponding acid, likely as a detoxification strategy to remove these reactive compounds.

59 BASIC BIOLOGICAL SCIENCES↗

Reconstruction of signal amplitudes in the CMS electromagnetic calorimeter in the presence of overlapping proton-proton interactions

A template fitting technique for reconstructing the amplitude of signals produced by the lead tungstate crystals of the CMS electromagnetic calorimeter is described. This novel approach is designed to suppress the contribution to the signal of the increased number of out-of-time interactions per beam crossing following the reduction of the accelerator bunch spacing from 50 to 25 ns at the start of Run 2 of the LHC. Execution of the algorithm is sufficiently fast for it to be employed in the CMS high-level trigger. It is also used in the offline event reconstruction. Results obtained from simulations and from Run 2 collision data (2015–2018) demonstrate a substantial improvement in the energy resolution of the calorimeter over a range of energies extending from a few GeV to several tens of GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The RAPTR furnace: a rapid heating and cooling sample furnace for in situ X-ray scattering studies of temperature-induced reactions

In situX-ray scattering provides valuable insights into the mechanisms and kinetics of reactions and structural transformations. For reactions and structural transformations primarily driven by temperature, and not coupled to chemical/electrochemical triggers, our ability to initiate and quench processes thermally is a practical limit for probing fast reactive phenomena. Meaningful quantitative analysis requires the dynamic phenomena to be triggered on fast time scales relative to the reaction/transformation kinetics. This article describes a new sample furnace, the Rapid-Actuating Pneumatic Thermal Reactor or RAPTR, for time-resolvedin situX-ray scattering studies initiated by temperature. The RAPTR quickly heats and cools samples by translating them into and out of a pre-heated hot zone. Using diffraction thermometry, it is shown that the samples can be heated/cooled in 10 s or less, with temperatures up to ∼1000°C being accessible. The application of the RAPTR furnace is demonstrated by exploring a fast solid-state reaction: the synthesis of scheelite-type lead tungstate, PbWO 4 , from PbO and WO 3 for which Pb 3 WO 6 is identified as a previously unrecognized reaction intermediate.

Chemistry↗