Search NASA⌕ Search

SEARCH · Search NASA

Results for “TaPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NASA/UK TAP

The purpose of the Technology Applications Program (TAP) is to provide problem solving information and assistance to both the public and private sectors in the Commonwealth of Kentucky, with emphasis primarily in the public sector. The TAP accesses over 1200 online computer databases, including files from the U.S., Canada, Europe, and Australia. During the 1985 to 1986 contract period, TAP responded to 645 inquiries which resulted in an increase of 16 percent over the 1984 to 1985 contract period. The activities of TAP for the 1985 to 1986 contract period are summarized.

Source record↗

Two Axis Pointing System (TAPS) attitude acquisition, determination, and control

The Two Axis Pointing System (TAPS) is a 2 axis gimbal system designed to provide fine pointing of Space Transportation System (STS) borne instruments. It features center-of-mass instrument mounting and will accommodate instruments of up to 1134 kg (2500 pounds) which fit within a 1.0 by 1.0 by 4.2 meter (40 by 40 by 166 inch) envelope. The TAPS system is controlled by a microcomputer based Control Electronics Assembly (CEA), a Power Distribution Unit (PDU), and a Servo Control Unit (SCU). A DRIRU-II inertial reference unit is used to provide incremental angles for attitude propagation. A Ball Brothers STRAP star tracker is used for attitude acquisition and update. The theory of the TAPS attitude determination and error computation for the Broad Band X-ray Telescope (BBXRT) are described. The attitude acquisition is based upon a 2 star geometric solution. The acquisition theory and quaternion algebra are presented. The attitude control combines classical position, integral and derivative (PID) control with techniques to compensate for coulomb friction (bias torque) and the cable harness crossing the gimbals (spring torque). Also presented is a technique for an adaptive bias torque compensation which adjusts to an ever changing frictional torque environment. The control stability margins are detailed, with the predicted pointing performance, based upon simulation studies. The TAPS user interface, which provides high level operations commands to facilitate science observations, is outlined.

Azzolini, John D.↗

Transmitter with fully re-assignable segments for reconfigurable FFE taps

Methods and systems of performing feed forward equalization (FFE) on data streams are described. A circuitry may generate staggered data streams from data streams of an input signal. The staggered data streams may include data in staggered unit intervals. The circuitry may include a plurality of segments. A segment may define a specific unit interval to carve the staggered data streams into one unit interval pulses positioned at the specific unit interval. The specific unit interval to carve the staggered data streams may indicate an assignment of the segment as one of a FFE pre tap, a FFE main tap, and a FFE post tap. The plurality of segments may be assigned to different FFE taps based on different clock signal selection defining different unit intervals to perform the carving. The plurality of segments may output respective one unit interval pulses to reproduce the input signal.

Toprak-Deniz, Zeynep↗

Assessing the Optimality of LinDist3Flow for Optimal Tap Selection of Step Voltage Regulators in Unbalanced Distribution Networks: Preprint

The adoption of distributed energy resources such as photovoltaics (PVs) has increased dramatically during the previous decade. The increased penetration of PVs into distribution networks (DNs) can cause voltage fluctuations that have to be mitigated. One of the key utility assets employed to this end are step-voltage regulators (SVRs). It is desirable to include tap selection of SVRs in optimal power flow (OPF) routines, a task that turns out to be challenging because the resultant OPF problem is nonconvex with added complexities stemming from accurate SVR modeling. While several convex relaxations based on semi-definite programming (SDP) have been presented in the literature for optimal tap selection, SDP based schemes do not scale well and are challenging to implement in large-scale planning or operational frameworks. This paper deals with the optimal tap selection (OPTS) problem for wye-connected SVRs using linear approximations of power flow equations. Specifically, the LinDist3Flow model is adopted and the effective SVR ratio is assumed to be continuous–enabling the formulation of a problem called LinDist3Flow-OPTS, which amounts to a linear program. The scalability and optimality gap of LinDist3Flow-OPTS are evaluated with respect to existing SDP-based and nonlinear programming techniques for optimal tap selection in three standard feeders, namely, the IEEE 13-bus, 123-bus, and 8500-node DNs. For all DNs considered, LinDist3Flow-OPTS achieves an optimality gap of approximately 1% or less while significantly lowering the computational burden.

linear approximations↗

Conductive Polymer Binder for High-Tap-Density Nanosilicon Material for Lithium-Ion Battery Negative Electrode Application

High-tap-density silicon nanomaterials are highly desirable as anodes for lithium ion batteries, due to their small surface area and minimum first-cycle loss. However, this material poses formidable challenges to polymeric binder design. Binders adhere on to the small surface area to sustain the drastic volume changes during cycling; also the low porosities and small pore size resulting from this material are detrimental to lithium ion transport. This study introduces a new binder, poly(1-pyrenemethyl methacrylate-co-methacrylic acid) (PPyMAA), for a high-tap-density nanosilicon electrode cycled in a stable manner with a first cycle efficiency of 82%-a value that is further improved to 87% when combined with graphite material. Incorporating the MAA acid functionalities does not change the lowest unoccupied molecular orbital (LUMO) features or lower the adhesion performance of the PPy homopolymer. Our single-molecule force microscopy measurement of PPyMAA reveals similar adhesion strength between polymer binder and anode surface when compared with conventional polymer such as homopolyacrylic acid (PAA), while being electronically conductive. Finally, the combined conductivity and adhesion afforded by the MAA and pyrene copolymer results in good cycling performance for the high-tap-density Si electrode.

25 ENERGY STORAGE↗

Multi-segment Winding Application for Axial Short Circuit Force Reduction Under Tap Changer Operation in HTS Transformers

High-temperature superconducting (HTS) transformers have remarkable appealing advantages over conventional ones. But higher brittleness of HTS windings with respect to copper windings makes HTS transformers more vulnerable in short circuit and inrush current situations. During tap changer operation, appreciable asymmetry and non-uniform distribution of ampere-turn along the windings causes high axial component of short circuit forces and makes the situation more severe. In this paper, multi-segment winding method is employed for reduction of axial short circuit forces. An analytical method is presented for calculation of axial component of short circuit forces under tap changer operation. Analytical method shows that with utilizing HLHLHLH asymmetrical multi-segment windings, during tap changer operation, the axial component of short circuit forces reduces significantly. The results of the analytical method are compared with the results of finite element method (FEM) model simulations, and the consistency is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exposure to arsenic in tap water and gestational diabetes: A French semi-ecological study

Highlights: • Exposure to arsenic in water was associated with a higher risk of gestational diabetes. • Association was significant for obese or overweight women but not for other women. • The potential interaction As exposure / body mass index must be further studied. • This semi-ecological study provides new data for low level of Arsenic in tap water (10–50 µg/L). The increase in the prevalence of gestational diabetes mellitus (GDM) and its consequences for mother and children prompts research on their risk factors including environmental factors. Studies on exposure to arsenic (As) in tap water and the risk of GDM have not provided conclusive evidence, particularly when levels of exposure were low (from 10 to 50 µg As/L). The main objective of this study was to assess the association between exposure to As in tap water and the risk of GDM.

54 ENVIRONMENTAL SCIENCES↗

Emerging Per- and Polyfluoroalkyl Substances in Tap Water from the American Healthy Homes Survey II

Humans experience widespread exposure to anthropogenic per- and polyfluoroalkyl substances (PFAS) through various media, which can lead to a wide range of negative health impacts. Tap water is an important source of exposure in communities with any degree of contamination but routine or large-scale PFAS monitoring often depends on targeted analytical methods limited to measuring specific PFAS. We analyzed 680 tap water samples from the American Healthy Homes Survey II for PFAS using non-targeted analysis (NTA) to expand the range of detectable PFAS. Based on detection frequency and relative abundance, about half of the identified PFAS were found only by NTA. We identified (with varying degrees of confidence) 75 distinct PFAS, including 57 exclusively detected by NTA. The identified PFAS are members of seven structural subclasses differentiated by their head groups and degree of fluorination. Clustering analysis categorized the PFAS into four coabundance groups dominated by specific PFAS subclasses. One group uniquely identified by NTA contains zwitterionic PFAS and other PFAS transformation products which are likely associated with aqueous firefighting foam contaminants in a small number of spatially correlated samples. These results help further characterize the scope of exposure to emerging PFAS experienced by the U.S. population via tap water and augment nationwide targeted-PFAS monitoring programs.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

π Berry phase and Zeeman splitting of Weyl semimetal TaP

Here, the recent breakthrough in the discovery of Weyl fermions in monopnictide semimetals provides opportunities to explore the exotic properties of relativistic fermions in condensed matter. The chiral anomaly-induced negative magnetoresistance and π Berry phase are two fundamental transport properties associated with the topological characteristics of Weyl semimetals. Since monopnictide semimetals are multiple-band systems, resolving clear Berry phase for each Fermi pocket remains a challenge. Here we report the determination of Berry phases of multiple Fermi pockets of Weyl semimetal TaP through high field quantum transport measurements. We show our TaP single crystal has the signatures of a Weyl state, including light effective quasiparticle masses, ultrahigh carrier mobility, as well as negative longitudinal magnetoresistance. Furthermore, we have generalized the Lifshitz-Kosevich formula for multiple-band Shubnikov-de Haas (SdH) oscillations and extracted the Berry phases of π for multiple Fermi pockets in TaP through the direct fits of the modified LK formula to the SdH oscillations. In high fields, we also probed signatures of Zeeman splitting, from which the Landé g-factor is extracted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a probabilistic timing model for the ingestion of tap water.

A contamination event in a water distribution system can result in adverse health impacts to individuals consuming contaminated water from the system. Assessing impacts to such consumers requires accounting for the timing of exposures of individuals to tap-water contaminants that have time-varying concentrations. Here we present a probabilistic model for the timing of ingestion of tap water that we developed for use in the U.S. Environmental Protection Agency's Threat Ensemble Vulnerability Assessment and Sensor Placement Tool, which is designed to perform consequence assessments for contamination events in water distribution systems. We also present a statistical analysis of the timing of ingestion activity using data collected by the American Time Use Survey. The results of the analysis provide the basis for our model, which accounts for individual variability in ingestion timing and provides a series of potential ingestion times for tap water. It can be combined with a model for ingestion volume to perform exposure assessments and applied in cases for which the use of characteristics typical of the United States is appropriate.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tapping mode microwave impedance microscopy

We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately simulated by the finite-element analysis and the result agrees quantitatively to the experimental data on a series of thin-film dielectric samples. The tapping mode microwave imaging is also superior to the contact mode in that the thermal drift in a long time scale is totally eliminated and an absolute measurement on the dielectric properties is possible. We demonstrated tapping images on working nanodevices, and the data are consistent with the transport results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Young's modulus variation with layer pair and interplanar spacing in gold–nickel nanolaminates using nanoindentation and the tapping mode

The features of grain size and interface separation strengthen the mechanical behavior of metallic nanolaminates. In addition, the presence of interlayer lattice strains can lead to a superlattice structure within the nanolaminate. The superlattice affects intrinsic properties of technological interest including electronic, magnetic, and elastic. The complex elastic and plastic behaviors of gold–nickel nanolaminate superlattice coatings as studied using nanoindentation are revisited with the tapping mode of a force microscope. Young's modulus is determined with nanoindentation during the initial elastic unloading after plastic deformation at depths up to one-fifth the coating thickness. The tapping mode provides a measurement during the initial elastic deformation at depths of only a few nanometers. The tapping mode utilizes the shift in the resonant frequency of the probe-cantilever system as contact is made with the sample surface. Both of these nanoprobe test methods produce results for measurements conducted with loading normal to the surface plane. A softening in the Young's modulus of gold–nickel nanolaminate coatings occurs for samples with layer pair spacing between 1 and 9 nm. The magnitude of softening corresponds with a progressive increase in the tensile state as measured with the change of interplanar spacing along the growth direction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Feasible voltage-tap based quench detection in a Ag/Bi-2212 coil enabled by fast 3D normal zone propagation

For this study, small insert solenoids have been built using a commercial Ag/Bi-2212 multifilamentary round wire, insulated with a new thin TiO 2 – polymer coating insulation (thickness in ~20 μm versus ~100 μm for a commonly used mullite braided sleeve insulation), and characterized in background magnetic field up to 14 T at 4.2 K to explore the high-field performance and quench detection of Bi-2212 magnets. The coil has no visible leakage and no electrical shorts after reaction, and it carries 280 A/mm -2 in a background field 14 T and generates an additional 1.7 T. A notable result is that, despite normal zones propagate slowly along the conductor, the hot spot temperature upon detection increases only from 40 K to 60 K when the resistive quench detection voltage threshold increases from 0.1 V to 1 V for all operating current density investigated, showing that quench detection using voltage taps is feasible for this coil. This is in a strong contrast to a coil we previously built to the same specifications but from wires insulated with the mullite braided sleeve insulation, for which the hot spot temperature upon detection increases from ~80 K to ~140 K while increasing from the detection voltage threshold from 0.1 V to 1 V, and thus for which quench detection using voltage taps presents significant risks, consistent with the common belief that the effectiveness of quench detection using voltage taps for superconducting magnets built using high temperature superconductors is seriously compromised by their slow normal zone propagation. This striking difference is ascribed to the fast transverse quench propagation enabled by thin insulation and improved thermal coupling between conductor turns. Finally, this work demonstrates that quench detection for high-temperature superconducting magnets highly depends on the design and construction of the coils such as insulation materials used and this dependence should be factored into the overall magnet design.

36 MATERIALS SCIENCE↗

Experimental discovery of a topological Weyl semimetal state in TaP

Here, Weyl semimetals are expected to open up new horizons in physics and materials science because they provide the first realization of Weyl fermions and exhibit protected Fermi arc surface states. However, they had been found to be extremely rare in nature. Recently, a family of compounds, consisting of tantalum arsenide, tantalum phosphide (TaP), niobium arsenide, and niobium phosphide, was predicted as a Weyl semimetal candidates. We experimentally realize a Weyl semimetal state in TaP. Using photoemission spectroscopy, we directly observe the Weyl fermion cones and nodes in the bulk, and the Fermi arcs on the surface. Moreover, we find that the surface states show an unexpectedly rich structure, including both topological Fermi arcs and several topologically trivial closed contours in the vicinity of the Weyl points, which provides a promising platform to study the interplay between topological and trivial surface states on a Weyl semimetal’s surface. We directly demonstrate the bulk-boundary correspondence and establish the topologically nontrivial nature of the Weyl semimetal state in TaP, by resolving the net number of chiral edge modes on a closed path that encloses the Weyl node. This also provides, for the first time, an experimentally practical approach to demonstrating a bulk Weyl fermion from a surface state dispersion measured in photoemission.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fixture For Drilling And Tapping A Curved Workpiece

Simple fixture guides drilling and tapping of holes in prescribed locations and orientations on workpiece having curved surface. Tool conceived for use in reworking complexly curved helicopter blades made of composite materials. Fixture is block of rigid foam with epoxy filler, custom-fitted to surface contour, containing bushings and sleeves at drilling and tapping sites. Bushings changed, so taps and drills of various sizes accommodated. In use, fixture secured to surface by hold-down bolts extending through sleeves and into threads in substrate.

Espinosa, P. S.↗

Thermal Analyzer for Planetary Soil (TAPS): an in Situ Instrument for Mineral and Volatile-element Measurements

Thermal Analyzer for Planetary Soil (TAPS) offers a specific implementation for the generic thermal analyzer/evolved-gas analyzer (TA/EGA) function included in the Mars Environmental Survey (MESUR) strawman payload; applications to asteroids and comets are also possible. The baseline TAPS is a single-sample differential scanning calorimeter (DSC), backed by a capacitive-polymer humidity sensor, with an integrated sampling mechanism. After placement on a planetary surface, TAPS acquires 10-50 mg of soil or sediment and heats the sample from ambient temperature to 1000-1300 K. During heating, DSC data are taken for the solid and evolved gases are swept past the water sensor. Through ground based data analysis, multicomponent DSC data are deconvolved and correlated with the water release profile to quantitatively determine the types and relative proportions of volatile-bearing minerals such as clays and other hydrates, carbonates, and nitrates. The rapid-response humidity sensors also achieve quantitative analysis of total water. After conclusion of soil-analysis operations, the humidity sensors become available for meteorology. The baseline design fits within a circular-cylindrical volume less than 1000 cm(sup 3), occupies 1.2 kg mass, and consumes about 2 Whr of power per analysis. Enhanced designs would acquire and analyze multiple samples and employ additional microchemical sensors for analysis of CO2, SO2, NO(x), and other gaseous species. Atmospheric pumps are also being considered as alternatives to pressurized purge gas.

Gooding, J. L.↗

Visualization of Simulation and TAP Interaction

The Temporal Analysis of Products (TAP) Reactor applies transient kinetics to analyze sophisticated chemical reaction mechanisms, rapidly changing temperature, flow rate, pressure or concentration and then monitoring the system’s time dependent response. A simulation tool exists for the TAP reactor, but it requires a visualization platform to interface effectively with researchers. This graphical user interface remedies this problem, fixing many of the difficulties caused by users interacting directly with the simulation code by providing an intuitive web application that satisfies the simulation input parameters for fast generation of data. This tool will ensure robust and repeatable simulation results, expedite the data generating process and enhance the overall ability of TAP to produce significant findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tapping mode microwave impedance microscopy

We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately simulated by the finite-element analysis and the result agrees quantitatively to the experimental data on a series of thin-film dielectric samples. The tapping mode microwave imaging is also superior to the contact mode in that the thermal drift in a long time scale is totally eliminated and an absolute measurement on the dielectric properties is possible. We demonstrated tapping images on working nanodevices, and the data are consistent with the transport results.

36 MATERIALS SCIENCE↗