Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tank 22”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Results from the Second MCU Flush DSSHT Sample

The Modular Caustic-Side Solvent Extraction Unit (MCU) stopped operations on May 22, 2019. As part of a plan to de-inventory the remainder of the liquids in the system, samples are sent to the Savannah River National Laboratory (SRNL) for analysis. A recent set of samples was pulled from the Decontaminated Salt Solution (DSS) Hold Tank (DSSHT) on 6/25/21, and arrived on the same day. The current DSSHT contents includes heel from the first flush of DSSHT (reference SRNL-L3100-2021-00019), deionized water (DIW) backflush of the DSS Coalescer, DIW flushes of the DSS Hydraulic Accumulator (DSSHA), DIW flush of the Contactor Drain Tank (CDT), and DSS Decanter drain material. The DIW flushes from the coalescer, DSSHA, and CDT were pumped through the DSS Decanter to allow for flushing of the DSS Decanter.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Genome reduction improves octanoic acid production in scale down bioreactors

Microorganisms in large-scale bioreactors are exposed to heterogeneous environmental conditions due to physical mixing constraints. Nutritional gradients can lead to transient expression of energetically wasteful stress responses and as a result, can reduce the titres, rates and yields of a bioprocess at larger scales. To what extent these process parameters are impacted is often unknown and therefore bioprocess scale-up comes with major risk. Designing platform strains to account for these intermittent stresses before introducing synthesis pathways is one strategy for de-risking bioprocess development. For example, Escherichia coli strain RM214 is a derivative of wild-type MG1655 that has had several genes and whole operons removed from its genome based on their metabolic cost. In this study, we engineered E. coli strain RM214 (referred to as WG02) to produce octanoic acid from glycerol in batch-flask and fed-batch bioreactor cultivations and compared it to an octanoic acid-producing E. coli MG1655 (WG01). In batch flask cultivations, the two strains performed similarly. However, in carbon limited fed-batch bioreactor cultivations, WG02 provided a greater than 22% boost to biomass compared to WG01 while maintaining similar titres of octanoic acid. Reducing the biomass accumulation of WG02 with nitrogen limited fed-batch cultivation resulted in a 16% improvement in octanoic acid titre over WG01. Finally, in a scale-down system consisting of a stirred tank reactor (representing a well-mixed zone) and plug flow reactor (representing an intermittent carbon starvation zone), WG02 again improved octanoic acid titre by almost 18% while maintaining similar biomass concentrations as WG01.

59 BASIC BIOLOGICAL SCIENCES↗

SCALE Analyses of Scenarios in the Molten Salt Reactor Fuel Cycle

In support of the US Nuclear Regulatory Commission non-light-water reactor fuel cycle demonstration project, the capabilities of SCALE 6.3.1 for radionuclide characterization, criticality, and shielding were demonstrated through several scenarios in a molten salt reactor (MSR) nuclear fuel cycle. Three scenarios were selected for this study, with the molten salt breeder reactor (MSBR) serving as the reference design. The original thorium-based fuel salt used in MSBR was replaced with a 235 U-enriched fuel salt to better reflect anticipated future MSR concepts. The first scenario focused on the fuel salt preparation stage. Criticality analyses, using SCALE/CSAS-Shift and SCALE/SAMPLER, examined potential critical configurations in the fresh fuel salt container based on variables such as 235 U enrichment, UF 4 molar fraction, temperature, and container geometry. The second scenario explored the release of fission products during reactor operation in which the tritium buildup in the primary fuel salt was quantified through depletion calculations using SCALE/TRITON with continuous fuel makeup and fractional fission product removal. This scenario also assessed radioactivity levels in the off-gas system (OGS), quantifying radiotoxic nuclides that could be released into the environment. SCALE/SAMPLER was employed to perform uncertainty quantification to identify key operating parameters influencing the buildup of radiotoxic nuclides in the OGS. Additionally, radiation dose rates were calculated using SCALE/MAVRIC to estimate the maximum exposure levels within the reactor cell complex during operation. The final scenario evaluated the decay heat and radioactivity of the primary fuel salt collected in the drain tank, as well as the radiation dose rate outside the building from the presence of the drain tank. Overall, the application of SCALE’s various capabilities for radionuclide inventory generation, criticality analysis, and shielding in MSR fuel cycles was successfully demonstrated across these scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uncertainty-Guided Prediction Horizon of Phase-Resolved Ocean Wave Forecasting Under Data Sparsity: Experimental and Numerical Evaluation

Accurate short-term wave forecasting is critical for the safe and efficient operation of marine structures that rely on real-time, phase-resolved ocean wave information for control and monitoring purposes (e.g., digital twins). These systems often depend on environmental sensors (e.g., waverider buoys, wave-sensing LIDAR). Challenges arise when upstream sensor data are missing, sparse, or phase-shifted due to drift. This study investigates the performance of two machine learning models, time-series dense encoder (TiDE) and long short-term memory (LSTM), for forecasting phase-resolved ocean surface elevations under varying degrees of data degradation. We introduce the τ-trimming algorithm, which adapts the prediction horizon based on uncertainty thresholds derived from historical forecasts. Numerical wave tank (NWT) and wave basin experiments are used to benchmark model performance under short- and long-term data masking, spatially coarse sensor grids, and upstream phase shifts. Results show under a 50% probability of upstream data loss, the τ-trimmed TiDE model achieves a 46% reduction in error at the most upstream target, compared to 22% for LSTM. Furthermore, phase misalignment in upstream data introduces a near-linear increase in forecast error. Under moderate model settings, a ±3 s misalignment increases the mean absolute error by approximately 0.5 m, while the same error is accumulated at ±4 s using the more conservative approach. These findings inform the design of resilient, uncertainty-aware wave forecasting systems suited for realistic offshore sensing environments.

42 ENGINEERING↗

PWR decay heat removal system in which steam from the pressurizer drives a turbine which drives a pump to inject water into the reactor pressure vessel

In conjunction with a pressurized water reactor (PWR) and a pressurizer configured to control pressure in the reactor pressure vessel, a decay heat removal system comprises a pressurized passive condenser, a turbine-driven pump connected to suction water from at least one water source into the reactor pressure vessel; and steam piping configured to deliver steam from the pressurizer to the turbine to operate the pump and to discharge the delivered steam into the pressurized passive condenser. The pump and turbine may be mounted on a common shaft via which the turbine drives the pump. The at least one water source may include a refueling water storage tank (RWST) and/or the pressurized passive condenser. A pressurizer power operated relief valve may control discharge of a portion of the delivered steam bypassing the turbine into the pressurized passive condenser to control pressure in the pressurizer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of Infrequent Samples from the Concentration, Storage, and Transfer Facility: Leak Detection Box (LDB) Drain Cell Sample: May 15, 2023, Sample

Savannah River Mission Completion Engineering (SRMC-E) requested that the Savannah River National Laboratory (SRNL) analyze the Concentration, Storage, and Transfer Facility (CSTF) samples from the following Tank Farm areas: the sump encasement, catch tank, drain cell, and waste tank annulus. In general, these CSTF samples will be analyzed on an infrequent basis and analyses will include detection for total beta/gamma activities, total alpha activity, free hydroxide, and pH measurement. SRMC-E corresponded with SRNL to obtain the final results through memo SRNL-L3120-2023-00013. This report presents characterization from results for the leak detection box (LDB) May 15, 2023, drain cell sample. The sample was clear and colorless with no visible particulates. The results are measurements for total gamma, total alpha, total beta, free hydroxide, pH, and density. These analyses were performed in triplicate. A summary of the average analytical results for the LDB sample includes the following. The measured pH for the LDB May 15, 2023 "as-received" drain cell sample range was 6.60-6.89, and the free hydroxide concentration as expected, based upon the pH, was <0.02 M. The average measured density of the "as-received" drain cell sample determined at 22 °C was 1.022±0.001 g/mL. the average measured total alpha activity for the LDB May 15, 2023, sample was 3.04E+02±1.13E+01. This value is less than 4.83E+03 dpm/mL, which is the procedural limit for non-waste determination. The total empirical activity of the beta and gamma emitting (represented by by the sum of total beta and B-137 m activities) averaged to 1.83+04±1.07E+03 dpm/mL. This value is less than 8.69E+05 dpm/mL, which is the procedural limit for non-waste determination.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Delivery of Dynamic Thermal Energy Storage Models and Advanced Reactor Concept Models to the HYBRID Repository

This publication details newly created energy storage and reactor models developed within the HYBRID modeling repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), sodium fast reactor (SFR), compressed air energy storage (CAES), liquid air energy storage (LAES) and Modelica standard library based two-tank sensible heat storage (SHS) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed. Also detailed in this report are future development goals for the HYBRID repository including adding suites of steady-state models, economic costing information, and reduced-order models. By adding these models in addition to the physical transient models currently existing within HYBRID, HYBRID will be a fully integrable tool for FORCE users.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Topical Analyses Related to Co-located Industrial Facilities at Nuclear Power Plants

This report investigates topics of interest with regard to Nuclear Power Plants (NPPs) utilizing flexible plant operations and generation (FPOG). Previous reports have identified the risk associated with co-located hydrogen generation facilities. This report evaluates special topics with regard to co-location of both hydrogen and syngas production facilities. A literature review was conducted to evaluate overpressure mitigation techniques that may be available to the NPP to reduce the consequence of an overpressure event. Also, the overpressure consequence of a catastrophic hydrogen storage tank failure event was analyzed. A comparison of the similarities and differences between the methodology utilized in HyRAM+ and Regulatory Guide 1.91 (R.G. 1.91) was performed for overpressure analysis. Also, the trinitrotoluene (TNT) equivalency methodology was utilized to evaluate an overpressure event at a Syngas production facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A process to verify numerical models for seismic fluid-structure interaction in advanced reactor vessels

Seismic design and qualification of a liquid-filled advanced nuclear reactor will have to account for fluid-structure interaction (FSI). Interaction between the tank, internal components, and contained liquid will rely on analysis of numerical models that must be verified and validated. Here this study demonstrates a verification process for models of a base-supported cylindrical tank by comparing numerical predictions and analytical solutions. The numerical models are consistent with the assumptions made to derive analytical solutions, namely, either a rigid or a linear elastic tank, ideal fluid, and small-amplitude, unidirectional, horizontal inputs. One software platform is used to illustrate the process. Seismic FSI analysis is performed using the Arbitrary Lagrangian-Eulerian (ALE) and Incompressible Computational Fluid Dynamics (ICFD) solvers in LS-DYNA. Reported responses are those used for design, including hydrodynamic pressures on the tank wall, shear forces and moments at the tank base, and wave heights of the contained liquid. The accuracy of the numerical results is discussed. The numerical models are verified for calculating the pressures on the tank wall and reactions at its base. Accurate simulation of wave action is challenging for both solvers. Recommendations for modeling, code development, and steps for verification are provided. Although focused on reactor vessels and one software platform, the verification process described herein is broadly applicable to liquid-filled vessels and other finite element codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Harnessing Fermentation May Enhance the Performance of Biological Sulfate-Reducing Bioreactors

Biological sulfate reduction (BSR) represents a promising strategy for bioremediation of sulfate-rich waste streams, yet the impact of metabolic interactions on performance is largely unexplored. Here, genome-resolved metagenomics was used to characterize 17 microbial communities in reactors treating synthetic sulfate-contaminated solutions. Reactors were supplemented with lactate or acetate and a small amount of fermentable substrate. Of the 163 genomes representing all the abundant bacteria, 130 encode 321 NiFe and FeFe hydrogenases and all genomes of the 22 sulfate-reducing microorganisms (SRM) encode genes for H 2 uptake. We observed lactate oxidation solely in the first packed bed reactor zone, with propionate and acetate oxidation in the middle and predominantly acetate oxidation in the effluent zone. The energetics of these reactions are very different, yet sulfate reduction kinetics were unaffected by the type of electron donor available. We hypothesize that the comparable rates, despite the typically slow growth of SRM on acetate, are a result of the consumption of H 2 generated by fermentation. This is supported by the sustained performance of a predominantly acetate-supplemented stirred tank reactor dominated by diverse fermentative bacteria encoding FeFe hydrogenase genes and SRM capable of acetate and hydrogen consumption and CO 2 assimilation. Thus, addition of fermentable substrates to stimulate syntrophic relationships may improve the performance of BSR reactors supplemented with inexpensive acetate.

59 BASIC BIOLOGICAL SCIENCES↗

Oxidation of Glycolate in the Defense Waste Processing Facility (DWPF) Recycle Collection Tank - 20305

The Savannah River Site's Defense Waste Processing Facility (DWPF) operations are being upgraded with the introduction of the Nitric-Glycolic Flowsheet. Glycolic acid has been shown superior to formic acid as the reducing acid used during chemical processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology and 3) adjustment of melter oxidation/reduction potential. Further, the potential for catalytic hydrogen generation in DWPF processing is virtually eliminated. DWPF process condensates are collected and returned to the SRS Concentration, Storage and Transfer Facilities (CSTF). The Recycle Collection Tank (RCT) collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle may contain a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, chemical oxidation within the RCT has been investigated as an option for mitigating the transfer of glycolate. Sodium permanganate has been down-selected as the best option for oxidation of glycolate. Testing was performed using both 2-L and 22-L reactors (16,800:1 and 1,530:1 scale by volume) with non-radioactive waste simulants to approximate the expected RCT compositions. RCT simulants were evaluated at various process pH and temperature conditions. Also, RCT operations, namely the sequence of addition of corrosion inhibitors (NaOH and NaNO{sub 2}) versus a permanganate strike, were evaluated. Glycolate was introduced via a sludge simulant to mimic both expected entrainment and abnormal process foam-over conditions - the range being between 68 and 5100 mg/kg glycolate. Glycolate destruction was monitored by ion chromatography (IC). The corresponding manganese behavior was monitored in real-time using in situ ultraviolet-visible (UV-Vis) spectroscopy. RCT glycolate content can be reduced to below the IC detection limit within 90 minutes for all concentrations investigated. Ion Chromatography analysis revealed that under alkaline conditions, glycolate is primarily oxidized to oxalate with no significant formation of CO{sub 2} or carbonate, and nitrite is not oxidized to nitrate. Initially, complete oxidation of organics species and nitrite was assumed. Determination of the mechanistic chemical reaction has allowed the required amount of permanganate to be more accurately predicted and the total addition to be significantly reduced. UV-Vis measurements reveal that permanganate (Mn{sup 7+}) is reduced to manganate (Mn{sup 6+}) in the RCT. The oxidant stoichiometry is defined by using the initial permanganate to glycolate (P/G) molar ratio. At low initial glycolate concentration (68 and 140 mg/kg), the minimum required initial permanganate to glycolate (P/G) molar ratio was found to be 5-6. With high initial glycolate concentrations (5100 mg/kg) a lower (P/G) molar ratio of ∼2.5 was needed. The final portion of this effort supporting the nitric/glycolic flowsheet will be to test actual (fully radioactive) RCT samples as per the above simulant tests. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surrogate-driven Variance-based Sensitivity Analysis of Thermal Storage Tanks in Integrated Energy Systems

Sensitivity analysis and uncertainty quantification are essential steps for enhancing the accuracy of computational models by identifying and mitigating uncertainties. This study focuses on these steps for the Thermal Energy Delivery System at Idaho National Laboratory, specifically targeting the thermocline tank. Using a Modelica/Dymola simulation model, the study perturbed various design parameters and boundary conditions, including shape factor, porosity, outlet temperature, inlet mass flow rate, and system pressure, to predict and quantify uncertainty in the tank’s ax- ial temperature. A dataset of over 1,000 simulations was generated, and surrogate models were developed using the pyMAISE (Michigan Artificial Intelligence Standard Environment) library, which is an Automatic Machine Learning library for nuclear engineering applications. The optimal model, a feedforward neural network with two hidden layers, achieved an R2 score above 0.99 and a mean absolute error below 1 Kelvin. Sensitivity analyses using Sobol indices and Fourier amplitude sensitivity testing methods on this surrogate model revealed that the inlet mass flow rate at initial timestamps and porosity significantly impacts predicted temperatures across all sensors and time steps.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Off-Gas Streams from Small- and Large-Scale Sparging Salt Vessels using Laser-Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy (LIBS) is being developed as an analytical monitoring tool for molten salt reactor (MSR) systems. A mobile LIBS platform was configured on a small-scale salt vessel (~100 g of salt) and then transported 0.6 km to successfully monitor an engineering-scale pumped salt loop (~100 kg of salt). Several studies on monitoring salt aerosols, hydrogen isotopes, and noble gases were performed on the small-scale system. All these studies were then implemented for monitoring various tests on the engineering-scale loop. Aerosolized salts from both the storage tank and pump bowl were monitored using LIBS to assess bulk salt analyte ratios (Mg, Na, K) and evaluate impurities (H, O, Ca). In addition to monitoring salt aerosols, LIBS was used in tandem with a residual gas analyzer (RGA) and a Raman spectroscopy system to detect hydrogen isotopes as they were sparged through and subsequently depleted from the loop storage tank. Lastly, a similar test with noble gases (100 ppm Kr, 1000 ppm Xe) was performed, in which LIBS demonstrated a faster response than the RGA used in-line. The tests and results are summarized in this report with detailed publications to follow. Key takeaways are listed in the conclusion of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Follow-On Status Report on FY2022 Model Development within the Integrated Energy Systems Hybrid Repository

This publication details newly created energy storage and reactor models developed within the HYBRID modeling repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), compressed air energy storage (CAES), and Modelica standard library based two-tank sensible heat storage (SHS) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recent Cryogenic Carbon Capture™ Field Test Results

Sustainable Energy Solutions (SES) has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time, two processes have been developed, the External Cooling Loop and Compressed Flue Gas CCC processes (CCC-ECL and CCC-CFG, respectively). The CCC-ECL process cools the flue gas with an external refrigerant loop. This process currently captures up to 1 tonne of CO2 per day (TPD). SES has tested CCC-ECL on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cement kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC-CFG process has been scaled up to a 0.25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal, and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2, and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC-CFG was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC generally, the results of CCC-ECL field testing, and future steps surrounding the development of this technology. Test results that will be presented have been collected during 9 months of testing at a commercial power plant under funding from the US Department of Energy (DOE) and the host utility. Testing of one of the systems at a commercial cement plant in the United States will also be discussed. During this testing, the system captured CO2 from the cement plant and stored the CO2 in pressurized tanks. These tanks were provided to a partner company that later used the CO2 in a CO2 utilization demonstration. The CO2 was utilized to cure concrete manufactured using cement from the same plant where the CO2 was captured. This integrated capture and utilization demonstration was the first time that the cement industry has shown in the field that it can sequester its CO2 emissions in its main product stream. This represents a potential game changing solution for industrial CO2 emissions. Operational data and host-site feedback indicate that the CCC process is ideally suited for deployment into a variety of commercial environments. A few areas of de-risking remain to make sure the technology can meet very strict industrial reliability standards. These areas of de-risking are identified and discussed. The product CO2 is shown to meet specification for many uses including industrial and merchant applications. The technology is nearing readiness for deployment at commercial scale and several initial target markets have been identified.

20 FOSSIL-FUELED POWER PLANTS↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗