Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tensile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measurement of grain boundary strength of Inconel X-750 superalloy using in-situ micro-tensile testing techniques in FIB/SEM system

Grain boundaries (GBs), known as two-dimensional defects, are omnipresent in polycrystalline metallic alloys and thus influence a wide range of mechanical properties under different environmental conditions like irradiation and corrosion. Therefore, quantifying the strength of individual GBs is critical for understanding the degradation of mechanical properties of materials under different conditions. In this study we developed an efficient approach for the fabrication of micro-tensile specimens with a GB almost perpendicular to the tensile direction, which is expected to advance the development of individual GB tensile testing at micro or nanoscale in a wide scope of materials. Further, an in-situ cantilever micro-tensile testing method was developed and used to quantify the strength of a Σ3 GB in Inconel X-750 with the combination of finite element modeling. The average ultimate tensile strength (UTS) of a non-irradiated Σ3 GB is estimated at around 1.4 GPa, comparable to that of a neutron-irradiated Σ3 GB with a dose of ~1.5 dpa (1.3 GPa). Moreover, the in-situ push-to-pull micro-tensile testing technique developed in this work provides valuable insights into the high-angle GB deformation and fracture behavior. This method generates qualitatively similar ductility behavior before and after neutron irradiation as the bulk material testing. However, the ductility and UTS values obtained from this method are different from bulk measurements due to vastly different specimen dimensions.

36 MATERIALS SCIENCE↗

Enhanced critical axial tensile strain limit of CORC ® wires: FEM and analytical modeling

Abstract Conductor on Round Core (CORC ® ) cables and wires are composed of spiraled high-temperature superconducting (HTS) rare-earth barium copper oxide (REBCO) tapes, wound in multiple layers, and can carry very high currents in background magnetic fields of more than 20 T. They combine isotropic flexibility and high resilience to electromagnetic and thermal loads. The brittle nature of HTS tapes limits the maximum allowable axial tensile strain in superconducting cables. An intrinsic tensile strain above about 0.45% will introduce cracks in the REBCO layer of straight HTS tapes resulting in irreversible damage. The helical fashion at which the REBCO tapes are wound around the central core allows tapes to experience only a fraction of the total axial tensile strain applied to the CORC ® wire. As a result, the critical strain limit of CORC ® wires can be increased by a factor of more than 10 that of REBCO tapes. Finite element (FE) and analytical models are developed to predict the performance of CORC ® wires under axial tensile strain. A parametric analysis is carried out by varying the winding angle, the Poisson’s ratio of the CORC ® wire core, the core diameter, and the tape width. The results show that a small variation in winding angle can have a significant impact on the cable’s axial tensile strain tolerance. While the radial contraction of the helically wound tapes in a CORC ® wire under axial tensile strain depends on its winding angle, it is mostly driven by the Poisson’s ratio of the central core, affecting the tape strain state and thus its performance. Contact pressure from multiple layers within the CORC ® wire also affects the CORC ® wire performance. The FE model can be used to optimize the cable design for specific application conditions, resulting in an irreversible strain limit of CORC ® cables and wires as high as 7%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tensile properties of 3D-printed wood-filled PLA materials using poplar trees

Fabrication of renewable materials through additive manufacturing using wood-filled polylactic acid (PLA) is an emerging field of study. The variability in the tensile properties of 3D-printed materials due to the variability in woody biomass properties has not been studied. Biomass size reduction, filament extrusion, and 3D-printing methods were investigated to determine the conditions that resulted in consistent printing. Using 20% ball-milled poplar reinforcement in PLA, 210 °C filament extrusion temperature and 230 °C printing temperature were found to be the best conditions. Subsequently, seventy poplar samples from a common garden were used to test the tensile properties of the printed materials. The median tensile strength at yield was 50 MPa, with 5–95 percentiles ranged in 37–54 MPa. Strain% at break had a median value of 2.1%, and 5–95 percentiles were 1.7–2.7%. The median Young's modulus was 3.65 GPa, and 5–95 percentiles ranged in 2.9–4.1 GPa. Biomass density was correlated to composite density. Median particle size of ball-milled poplar was negatively correlated with tensile strength. Composite density affected tensile strength of the composite. β-glycosidic bond of polysaccharides in biomass affected Young's modulus of the composite. Overall, these data show that genotypic variation among Populus trichocarpa have substantial effect on tensile properties of 3D printed PLA-poplar materials.

36 MATERIALS SCIENCE↗

Capillary flow in UHPFRC with synthetic fibers, under high tensile stresses

A novel Ultra High-Performance Fiber Reinforced Concrete (UHPFRC) mix with synthetic fibers and a low clinker matrix, henceforth referred to as PE-UHPFRC, has been developed for structural applications. It exhibits a high tensile elastic limit above 7 MPa, a tensile strength of more than 10 MPa, and a very high tensile hardening domain of above 3.5%. In order to effectively use this material, its protective properties have been investigated on the basis of the effect of tensile deformation and subsequent cracking on water transport properties, for a wide range of tensile strain. A special setup was developed to measure the capillary absorption of liquids while the specimen is under tension. The results show a considerable reduction in capillary absorption in case of PE-UHPFRC compared with Strain Hardening Cement-based Composites (SHCC). Moreover, the results highlight the considerable effect of the onset of cracking on capillary absorption.

36 MATERIALS SCIENCE↗

Extracting single fiber transverse and shear moduli from off-axis misalignment fiber tensile testing

Small diameter (<100 μm) fibers (e.g. carbon fibers, Kevlar, and fiberglass) and wires (e.g. ultrafine copper and aluminum wires) are frequently used in many different engineering applications, such as for light weighting structures, electromagnetic shielding for aircraft/infrastructure/EVs, vibration damping, biological sensors, aerospace electrical devices, and electric windings just to name a few. Due to the manufacturing process, the fibers and wires are pulled and stretched to produce a preferential alignment. Therefore, thin fibers and wires typically display different properties along the length of the fiber as opposed to their cross section and many fibers/wires are considered transversely isotropic. The axial properties of fibers/wires can be ascertained via tensile testing of single-filaments or fiber tows, but the radial properties require much more effort to measure. Knowing these properties is important for the accurate prediction of micromechanical models and manipulation of fibers during micromanufacturing. In this paper, a new technique was developed to determine the transverse/shear moduli and strength of a material by conducting tensile tests of the material at increasing misalignment angles from the tensile axis. Due to the transversely isotropic nature of the material, the transverse/shear moduli and strength influence the experimental results recorded by the test machine to different degrees based on the amount of misalignment in the test setup. An equation was derived to determine the influence of each of the material properties based on the misalignment angle by manipulating the stiffness matrix for transversely isotropic materials using the transformation matrices. Then, curve fitted coefficients were used to identify the material properties. Here, the strengths were similarly determined by curve fitting an off-axis Tsai-Hill failure criteria to determine the influence of transverse, shear, and tensile strengths based on the complex loading condition provided by the off-axis tensile test. Zoltek Panex 35 carbon fibers were used to demonstrate this new technique and the determined properties were then compared to those obtained from nanoindentation and from literature. Fracture surfaces provide insight into the different failure mechanisms at various misalignment angles.

36 MATERIALS SCIENCE↗

Analyzing the effect of misalignment on single-filament carbon fiber tensile testing via stereoscopic computer vision imaging

An understanding of the constitutive properties of carbon fibers (CF) is critical to the accuracy of high-resolution composite simulations and to the development of CF derived from low-cost alternative precursor materials. Single-fiber tensile testing is a capable tool to measure CF properties and is well suited to research efforts where only a small number of fibers may be available. However, single-fiber tensile tests are challenging to conduct due to the difficulty in handling small diameter fibers (5-15 μm), the brittleness of single fibers, and the required nanoscale/microscale resolution of testing equipment. The accuracy of the measured properties depends on several factors, but a critical factor is fiber misalignment, especially at short gauge lengths. Current standards do not address the effect of tensile specimen misalignment on measured properties. Furthermore, this work presents a robust method of fiber alignment using stereoscopic computer vision that enables users to align fibers vertically for tensile testing to improve the accuracy of resulting mechanical properties. Additionally, an analytical relationship between fiber misalignment angle and measured properties is developed and validated against the experimental results. As a result, new best practices for single-fiber tensile testing of CF are recommended.

47 OTHER INSTRUMENTATION↗

A Comparative Study on Representativeness and Stochastic Efficacy of Miniature Tensile Specimen Testing

Here, in this article, a miniature dog bone tensile coupon design was tested against the existing ASTM standard specimen design. Specimens were prepared from commercially sourced austenitic stainless steel 304 alloy, and a defect-ridden additively manufactured 304L alloy was studied. By utilizing a tensile specimen design that is 1/230th volume of the smallest ASTM E8-04(2016), Standard Test Methods for Tension Testing of Metallic Materials, dog bone specimen, coupled to a digital image correlation (DIC) setup, case studies were performed to compare tensile property measurements and strain field evolution. Whereas yield strength measurements were observed to be similar, post-yield, the ultimate strength measurements and ductility measurements from the miniature specimens were observed to be higher than the ASTM specimen design. Although the strength measurements were comparable, the strain evolution was found to differ in the miniature specimens. Studies to assess effects of varying thickness and defect population were also pursued on the miniature tensile specimen. From the DIC strain field estimations, the peak local strain values at ultimate tensile strength were observed to be increasing with reducing specimen thickness. Testing of defect ridden stainless steel revealed the sensitivity to failure through strain localization and the influence of defect size was captured in the strength measurements.

36 MATERIALS SCIENCE↗

Swab Tensile Testing Results and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the “Aged” swabs. For the “Aged” swabs, the tensile tests were performed 7 days after the Autoclave pre -treatment. All swabs were provided by HP.

36 MATERIALS SCIENCE↗

Swab Tensile Testing Results and Procedures

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. A variety of different swabs (different materials and different geometries) were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the Injection Molded samples. For the Injection Molded samples, the tensile tests were performed within 24 hours of the completion of the Autoclave pre-treatment. The FormLabs-USF and FormLabs-Northwell were printed at LLNL using FormLabs Surgical Grade V1 Resin on a Form 3B Printer. All other samples were provided by HP.

36 MATERIALS SCIENCE↗

Swab Tensile Testing Results and Procedures - PA11 Rev. 10 Swabs

This tensile test is to mimic the worst-case scenario of the swab being caught on an obstruction when being pulled out of the nasopharyngeal space. It is to determine how much tensile force the swab can withstand without breaking. All swabs were provided by HP and were the PA11 material and Rev 10 design. All of the swabs were tested using the protocol outlined in Section 2 (Tensile Testing Procedure). Not all of the swabs were pre-treated using the Autoclave. For those swabs that were pre-treated using the Autoclave, the tensile tests were performed within 6 hours of completion of the Autoclave pre-treatment, with the exception of the “Aged” swabs. For the “Aged” swabs, the tensile tests were performed 7 days after the Autoclave pre -treatment. The “Aged” swabs that were not pre-treated using the Autoclave, were tested 7 days after those that were not “Aged.”

36 MATERIALS SCIENCE↗

Tensile Property and Lifetime Prediction for Low-Temperature Aged Uranium-Niobium Alloys

Thermal aging models and lifetime predictions for uranium-niobium (U-Nb) alloys were created using an approach similar to those previously employed. Lifetime estimates for generic U-6Nb components were thus updated; the reported value being 800 years. This update represents a small change in lifetime vs. that of the 2012 assessment (540 years). This lifetime estimate emerged from consideration of several model fits specific to the aging datasets and properties chosen. Aging was quantified using quasi-static tensile properties measured on specimens artificially aged for up to 10 years. The major change relative to the most recent 2012 LANL assessment was that a more comprehensive body of U-Nb literature data was mined, in addition to being augmented by the latest LANL and UK AWE data. The tensile data compilation was published separately (LANL report LA-14493, December 2016). Recognizing the chemical banding of industrially produced U-6Nb, models were developed for the mid-range (6 wt.%) and extrema (4 and 8 wt.%) compositions. Lifetime estimates were calculated for all three alloy classes (4, 6, 8 wt.% nominal) and two measures of total tensile elongation (TE) to failure, namely TE-ext. — extensometer method, and TE-NCD — normalized crosshead displacement method. The conservative assumption was made that whichever composition (4, 6, or 8 wt.% Nb) and property (TE-ext or TE-NCD) was the first to cross the ductility failure threshold would limit the lifetime of the entire component. Tensile strength properties did not figure into the lifetime predictions, but could be useful as age-sensitive diagnostics and were also modeled. Of these, only first yield strength is expected to show a change at 40°C aging vs. time = 0 over the ~100-year timespan of engineering interest. Second yield strength evolves more slowly, and ultimate tensile strength slower still. Among all the models, the apparent activation energies for aging were mostly in the narrow 29– 37 kcal/mol range, which is close to that for diffusion of Nb in gamma-uranium. This agreement may be coincidental. The data from recent long-term aging studies substantially improved the model fit quality and robustness of the lifetimes. Appendices document sensitivity studies of the model fits and lifetimes with respect to using more limited datasets. These results highlight the limitations of relying solely on data from scattered literature studies and smaller datasets more generally.

36 MATERIALS SCIENCE↗

P- and S-Wave velocity and Indirect Tensile Measurements for Alluvium in Support of the Source Physics Experiments

Mechanical properties on alluvium blocks and core samples were determined to support the Source Physics Experiment Dry Alluvium Geology experimental series. Because material was not available directly from the experimental location, the alluvium blocks and core samples are intended to serve as surrogate material . P - and S - wave velocity was measured on cubes cut from the alluvium blocks and core with the intention to study variation from water content and measured direction (material anisotropy). Indirect tensile tests were conducted dry and with moisture ranging from 6 to 9.1%. For the range of water content tested, increasing moisture level resulted in slower P - and S - wave velocities. P - and S - wave variability is less influenced by material heterogeneity than moisture content. P - wave velocity ranges from 629 m/s to 2599 m/s and S - wave velocity ranges from 288 m/s to 1200 m/s. Counter to the velocity measurement findings, material variability on indirect tensile strength has a greater effect than moisture content. Compared to dry strength and at moisture levels from 6 to 9% the block's tensile strength was lowered by at least a factor of 5. Indirect tensile strength for the first block averaged 0.35 MPa and 0.25 MPa for dry and 8.9% moisture respectively. For the second block indirect tensile strength averaged 0.05 MPa for both dry and 6.4% moisture.

36 MATERIALS SCIENCE↗

Effects of Sodium Exposure on the Tensile Properties of Grade 91 steel

Two heats of G91 steel have been investigated in liquid sodium at 550- 650°C to understand their corrosion behaviour, microstructural evolution, and tensile properties. Sodium exposure experiments of subsized, sheet-type tensile specimens of G91 were performed in Argonne’s forced convection sodium materials testing loops, SMT-1 and SMT-2. Maximum exposure times of ~49,000 h at ~38,000 h, and ~20,000 h have been achieved at 550, 600, and 650°C, respectively. Thermal aging experiments of G91 steel were also conducted in parallel, and the results were compared with those of the sodium-exposed specimens to isolate the effect of thermal aging from the effect of sodium exposure. It was found that the yield stress and ultimate tensile strength of G91 were reduced by more than 50% after sodium exposures at 650°C due to decarburization. The reduction in tensile strength was accompanied by the dissolution of M 23 C 6 carbides and excessive grain growth. The effect of sodium at 550 and 600°C was insignificant for exposure times up to ~49,000 h and ~38,000 h, respectively. The effect of sodium on the microstructural stability and tensile properties of G91 is largely dependent on the carbon mass transfer in the alloy-sodium system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Sample Thickness on the Tensile Strength of Small Graphite Discs

This report formally documents the completion of the Advanced Reactor Technologies (ART) Level 3 Milestone (M3TG-24OR0501054), “Continue activities related to Split Disc-DIC - complete analysis of effect of sample thickness on one fine grain graphite,” due May 31, 2024. Details within this report outline the status of activities aimed at elucidating the effect of sample thickness on the tensile strength measurement using the small-disc, split-disc testing standard in support of the US Department of Energy’s ART Graphite R&D Program. The ASTM D8289, Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite, was developed to provide an alternative means for testing tensile strength on smaller specimens, which are compatible with available irradiation capsule volumes, and other compatibility measurements. ASTM D8289 specifies that acceptable specimen diameter can range from 6 to 12.7 mm and that the maximum allowed sample thickness should be half of the diameter. However, information is limited with respect to the effect of thickness on the measured splitting tensile strength. This report documents efforts to understand the effect of sample thickness on splitting tensile strength. The work involved testing Ø12.7 mm samples of fine-grain graphites 2114 and IG-110 of different thicknesses (6.35, 5, 4, and 3 mm). The digital image correlation (DIC) method was applied to the samples, along with the ASTM D8289 Standard, to help interpret the measured results.

36 MATERIALS SCIENCE↗

Splitting tensile strength of shale cores: intact versus fractured and sealed with ureolysis-induced calcium carbonate precipitation (UICP)

Ureolysis-induced calcium carbonate precipitation (UICP) is a biomineral solution where the urease enzyme converts urea and calcium into calcium carbonate. The resulting biomineral can bridge gaps in fractured shale, reduce undesired fluid flow, limit fracture propagation, better store carbon dioxide, and potentially enhance well efficiency. The mechanical properties of shale cores were investigated using a modified Brazilian indirect tensile strength test. An investigation of intact shale using Eagle Ford and Wolfcamp cores was conducted at varying temperatures. Results show no significant difference between shale types (average tensile strength = 6.19 MPa). Eagle Ford displayed higher strength at elevated temperature, but temperature did not influence Wolfcamp. Comparatively, cores with a single, lengthwise heterogeneous fracture were sealed with UICP and further tested for tensile strength. UICP was delivered via a flow-through method which injected 20–30 sequential patterns of ureolytic microorganisms and UICP-promoting fluids into the fracture until permeability reduced by three orders of magnitude or with an immersion method which placed cores treated with guar gum and UICP-promoting fluids into a batch reactor, demonstrating that guar gum is a suitable inclusion and may reduce the number of flow-through injections required. Tensile results for both delivery methods were variable (0.15–8 MPa), and in some cores the biomineralized fracture split apart, possibly due to insufficient sealing and/or heterogeneity in the composite UICP-shale cores. Notably in other cores the biomineralized fracture remained intact, demonstrating more cohesion than the surrounding shale, indicating that UICP may produce a strong seal for subsurface application.

58 GEOSCIENCES↗

Facile Tensile Testing Platform for In Situ Transmission Electron Microscopy of Nanomaterials

In situ tensile testing using transmission electron microscopy (TEM) is a powerful technique to probe structure-property relationships of materials at the atomic scale. In this work, a facile tensile testing platform for in situ characterization of materials inside a transmission electron microscope is demonstrated. The platform consists of: 1) a commercially available, flexible, electron-transparent substrate (e.g., TEM grid) integrated with a conventional tensile testing holder, and 2) a finite element simulation providing quantification of specimen-applied strain. The flexible substrate (carbon support film of the TEM grid) mitigates strain concentrations usually found in free-standing films and enables in situ straining experiments to be performed on materials that cannot undergo localized thinning or focused ion beam lift-out. The finite element simulation enables direct correlation of holder displacement with sample strain, providing upper and lower bounds of expected strain across the substrate. The tensile testing platform is validated for three disparate material systems: sputtered gold-palladium, few-layer transferred tungsten disulfide, and electrodeposited lithium, by measuring lattice strain from experimentally recorded electron diffraction data. The results show good agreement between experiment and simulation, providing confidence in the ability to transfer strain from holder to sample and relate TEM crystal structural observations with material mechanical properties.

2D materials↗

Exploring biofiber properties and their influence on biocomposite tensile properties

Biofibers serve as effective reinforcements for neat polylactic acid (PLA) in biocomposites, offering an attractive opportunity to decarbonize the manufacturing sector of the United States by displacing fossil-based reinforcement fibers such as carbon fibers. Also, biofiber production can stimulate economic growth in rural economies, fueling sustainable development. PLA resins are commonly compounded with biofibers to create biocomposites suitable for additive manufacturing. PLA-biofiber composites often exhibit better overall material properties than neat (pure) PLA, but the associations between biofiber properties and the material properties of their biocomposites remain largely unexplored. Hence, this research delves into a comprehensive exploration of diverse biofibers, scrutinizing their physical and chemical attributes, including size, shape, ash content and biochemical composition. The study meticulously analyzes the flow properties of each biofiber and elucidates the ultimate tensile strengths and Young's modulus of corresponding biocomposite samples. Noteworthy correlations between biofiber and biocomposite tensile properties are uncovered, shedding light on critical interrelationships. The study introduces an approach employing regression models to predict the ultimate tensile strength and Young's modulus of biocomposites. These models, validated with a cross-validation technique, exhibit remarkable predictive accuracy, particularly in estimating ultimate tensile strength. © 2024 Oak Ridge National Laboratory managed by UT-Battelle, LLC and The Author(s). Polymer International published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.

36 MATERIALS SCIENCE↗

Critical Review of Brazil Disk Techniques for Tensile Strength Characterization With an Emphasis on High Explosive Materials

Mechanical properties are a critical performance metric for many high explosive (HE) materials and tensile strength properties are particularly important. Direct tensile measurements using dogbone shaped samples are the gold standard but they have the disadvantage that they are fairly large and require samples machined from billets. Diametral compression, more commonly known as Brazil disk (BD) testing, is an indirect method for measuring tensile strength on smaller and more easily fabricated samples. A review of the BD literature is presented with an emphasis on tensile strength measurements in high explosive materials. BD literature is reviewed in three primary areas: (i) rocks and concrete, (ii) pharmaceutical materials, and (iii) high explosive materials. The literature for rocks/concrete is extensive and dates back over 80 years; despite this there is no consensus on the validity/accuracy of the BD technique or the optimal variant of the BD technique to employ. The pharmaceutical literature is the opposite, being limited in scope and quantity of studies. BD literature on high explosive materials falls in between, not as impressive as in the rocks/concrete community but more substantiative than in the pharmaceutical community. After the review of the literature practical parameters for HE BD testing and recommended future work is discussed.

Brazil disk↗