31 records · Page 2

Internal Insulation and Corrosion Control of Molten Chloride Storage Tanks

The National Renewable Energy Laboratory (NREL) is leading a multi-national team to validate the potential of a chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl to provide higher temperature thermal energy storage capability, thereby allowing for higher efficiency in the power block of next-generation concentrating solar power systems. While higher thermal stability, greater operating temperature, and a more efficient power cycle are possible, the molten chlorides present several unique challenges, including the design of internal liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the design of the molten salt storage tanks.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Internal insulation and corrosion control of molten chloride thermal energy storage tanks

A chloride-based molten-salt system that uses a ternary blend of MgCl 2 /KCl/NaCl is investigated to provide higher-temperature thermal energy storage capability than conventional nitrate salt-based systems. Despite their high thermal stability and operating temperature, molten chlorides present several challenges, including the design of internal liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the optimization of the hot face refractory materials for use as internal liners. Furthermore, three down-selected refractory materials were analyzed with respect to permeation of salt through the material as well as chemical stability during high temperature operation. Through the application of X-ray imaging and electron spectroscopy techniques, highly stable secondary surface phases in equilibrium with the molten salt were identified, as well as time-dependent changes in the salt composition itself.

25 ENERGY STORAGE↗

System Design of a 2.0 MWth Sodium/Molten Salt Pilot System

Nitrate molten salt concentrating solar power (CSP) systems are currently deployed globally and are considered state-of the art heat transfer fluids (HTFs) for present day high-temperature operation. Although slightly higher limits may be possible with molten salt, to fully realize SunShot efficiency goals of $15/kWhth HTFs and an LCOE of 6¢/kWh, HTF technologies working at higher temperatures (e.g., 650 °C to 750 °C) will require an alternative to molten salts, such as with alkali metal systems. This investigation explores the development of a 2.0 MWth sodium receiver system that employs a sodium receiver as the HTF, as well as with a ternary chloride (20%NaCl/40%MgCl/40%KCl by mol wt.%) salt as a thermal energy storage (TES) medium to facilitate a 6-hr. storage duration. A sodium-to-salt heat exchanger model as well as a salt-to-sCO2 primary heat exchanger model are employed and evaluated in this investigation. A thermodynamic system design model was developed using Engineering Equation Solver (EES) where state properties were calculated at inlets and outlets along both hot and cold legs of the pilot-scale plant. This investigation assesses receiver performance as well as system efficiency studies for the pump and system operational ranges. Results found that high efficiency sodium receivers were found to have higher heat transfer coefficients and required far less spreading of incident flux. The system performance model results suggest that for a pump speed of 2400 RPM, respective hot and cold pump TDH values were determined to be 260.1–307 ft. and 260.1–307 ft for pump flow rates of 90–120 GPM.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60°C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant: Preprint

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99 ®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60 °C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Internal Insulation and Corrosion Control of Molten Chloride Storage Tanks

The U.S. Department of Energy Gen3 CSP program aims to develop integrated systems capable of delivering high temperature thermal energy to advanced power cycles [1]. The National Renewable Energy Laboratory (NREL) is leading a multi-national team to validate the potential of a chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl to provide higher temperature thermal energy storage capability (Fig. 1a). The economic viability of this concept is dependent on internally insulating the hot and cold storage tanks to enable the use of low-cost steel shells (Fig. 1b).

14 SOLAR ENERGY↗

Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve

To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.

Armijo, Kenneth (ORCID:0000000346832147)↗

Autogenous formation and smart behaviors of nitrite- and nitrate-intercalated layered double hydroxides (LDHs) in Portland cement-metakaolin-dolomite blends

In this work, the influence of sodium nitrite (NaNO{sub 2}) and sodium nitrate (NaNO{sub 3}) corrosion inhibitors on the composition, structure, and chloride binding behaviors of layered double hydroxides (LDHs) formed in ternary ordinary Portland cement-metakaolin-dolomite (OPC-MK-DM) systems is studied. The results show that the nitrite and nitrate anions are preferably intercalated in the CaAl LDHs (AFm phases), but not in the MgAl LDHs (hydrotalcite-type phases) due to its limited formation in these ternary cementitious systems cured at ambient temperature. The autogenously formed nitrate- and nitrite-AFm phases are decomposed upon chloride exposure accompanied by Friedel's salts formation, potentially releasing corrosion inhibitive ions to the pore solution in a progressive manner. The NaNO{sub 2} and NaNO{sub 3} incorporation in ternary OPC-MK-DM binders marginally lowers chloride binding capacity but reduces its penetration resistance mainly due to pore coarsening. Nevertheless, a strong linear correlation can be established between the water-soluble and total chloride contents in ternary OPC-MK-DM systems, regardless of OPC replacement level and corrosion inhibitor incorporation.

36 MATERIALS SCIENCE↗

Engineering-Scale Batch Purification of Ternary MgCl 2 -KCl-NaCl Salt Using Thermal and Magnesium Contact Treatment

High-temperature molten chloride salts are a desirable heat transfer and energy storage media. The NaCl-KCl-MgCl 2 is of particular interest because of its low melting point and relatively inexpensive constituents. Moisture and hydroxides must be removed from the salt to control corrosion at high temperatures. Previous studies have developed and demonstrated various techniques for bench-scale salt purifications. This paper details the system, process, and insight gained in the purification of a 200 kg scale batch of NaCl-KCl-MgCl 2 salt at Oak Ridge National Laboratory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Density Measurements of Various Molten Sodium, Magnesium, Potassium, and Uranium Chloride Salt Compositions Using Neutron Imaging

With an increased interest in the use of molten salts for energy generation, obtaining thermophysical properties of salt mixtures becomes critical for the understanding of salt performance and behavior. Density is one of the significant thermophysical properties of salt systems. This work presents the density measurement of molten chloride salt mixtures using neutron imaging. This work was performed at the Oak Ridge National Laboratory High-Flux Isotope Reactor. Here, resulting densities as a function of temperature for different molten chloride salts from this work were compared with calculated values using Redlich–Kister modeling. Agreement between the calculated and measured values was within 1–10%, with the exception of the ternary UCl 3 –NaCl–KCl salt that showed a 32% discrepancy between several literature reports; however, the results did align well with another neutron radiography article. Analysis of the radiographs suggests that microbubbles in the ternary mixture might have biased the density measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chloride Salt Purification by Reaction With Thionyl Chloride Vapors to Remove Oxygen, Oxygenated Compounds, and Hydroxides

Molten chloride salts (including MgCl 2 , KCl, NaCl, and ZnCl 2 ) are being considered for heat transfer media for renewable (solar) and nuclear power generators, as fuel carrier for nuclear reactors, and as thermal energy storage media. Impurities such as oxygen, hydroxides, moisture, and sulfur are known to negatively influence the corrosion of materials in contact with the salt (e.g., structural metals). Commercially available chloride salts come with a range of impurities. Before using the chloride salts at high temperature, it is desirable to remove the impurities to increase the performance of the salt and reduce corrosion. In this study, we tested the use of thionyl chloride vaporized into a stream of argon to react with oxygenated impurities in a mixture of MgCl 2 -KCl-NaCl, removing them as HCl and SO 2 . The reagent was bubbled through the salt when both above and below the melting point. The reaction was followed using thermocouple data from the salt and by Fourier transform infrared (FTIR) spectroscopy on the exhaust of the reactor. The reaction kinetics were followed by comparing the peaks from SO 2 product to SOCl 2 reagent in the FTIR spectra. The purity of the salt was assessed at the end of the purification process by x-ray diffraction and inductively coupled plasma analysis. Although the process was effective in removing the oxygen content of the mixture, ternary compounds were formed in the process, including KNiCl 3 and KMgCl 3 . The nickel in KNiCl 3 came from the reaction between the salt and the nickel vessel. Thus, these experiments suggest that improvements to the process must be made before using SOCl 2 vapors for the purification of chloride salts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stability of brines on Mars

The detection of high chlorine and sulfate abundances and duricrusts on Mars strongly suggests the occasional presence of brines on the Martian surface. Ternary phase diagrams for the likely chloride and sulfate brines indicate that the minimum temperature at which a brine can be stable is near 210 K with a water concentration of approximately 70 wt % and a high concentration of calcium chloride. The dominance of sulfate over chlorine in the Martian regolith suggests precipitation of salts at temperatures higher than the minimum.

Brass, G. W.↗

Thermodynamic properties of ZrCl 4 with LiCl, NaCl, KCl, CsCl, MgCl 2 , and UCl 3 for molten salt reactor applications

Here, a set of self-consistent Gibbs energy functions has been developed to describe the thermochemical behavior of the major reactive fission product ZrCl 4 with key components in chloride molten salt reactors (MSRs): LiCl–ZrCl 4 , NaCl–ZrCl 4 , KCl–ZrCl 4 , CsCl–ZrCl 4 , MgCl 2 –ZrCl 4 and UCl 3 –ZrCl 4 . Low ZrCl 4 concentration phase equilibria most relevant to MSR applications have been confirmed via differential scanning calorimetry for NaCl–ZrCl 4 , and X-ray diffraction analysis performed on equilibrated samples of NaCl–ZrCl 4 , KCl–ZrCl 4 , MgCl 2 –ZrCl 4 , and UCl 3 –ZrCl 4 . Within the framework of the modified quasi-chemical model in the quadruplet approximation, extrapolations of pseudo-binary models were generated to represent KCl–MgCl 2 –ZrCl 4 , KCl–NaCl–ZrCl 4 , and MgCl 2 –NaCl–ZrCl 4 , which show agreement with phase equilibria data where available without the use of ternary interaction parameters. The optimized thermodynamic descriptions for these systems and others are available in the open-source compendium Molten Salt Thermal Properties Database – Thermochemical (MSTDB–TC).

CALPHAD↗