Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test Engineering Fixture Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Validation of Manufacturing Process Designs for Stamped Microchannel Recuperators

Microchannel recuperators can achieve high-efficiency power cycles and chemical reactions by recovering waste heat from hot turbine exhaust and chemical reaction streams. However, the industrial application of microchannel recuperators are restricted by the high cost of patterning and bonding. The objective of this study was thus to investigate new methods for producing microchannel recuperators for emerging markets. Based on greenfield cost estimates, process designs based on stamping, laser welding and vacuum brazing of 316L stainless steel laminae were found to be more economical than conventional photochemical machining and diffusion bonding. Subsequently, validation experiments were conducted to produce stamped microchannel components using cost model parameters. At a mass flow rate of 0.99 g/s, the test article made with laser welding was found to provide higher effectiveness than the test article produced using vacuum brazing. Preliminary investigations showed that residual stresses during laser welding of the laminae led to significant warpage, collapsing channels and making lamina-to-lamina fit up challenging. In contrast, the test article produced by vacuum brazing of stamped laminae showed no clogging and 4.6% and 10.5% channel height standard deviation for the cold and hot channels, respectively. Channel variation in the vacuum brazing sample was determined to be caused by misregistration of laminae during brazing. In future work, efforts are needed to choose cheaper, more ductile brazing foils as well as design a brazing fixture to improve lamina-to-lamina registration.

42 ENGINEERING↗

Improve Replication of In-service Mechanical Environments

Structural dynamic testing is a common method for determining if the design of a component of a system will mechanically fail when deployed into its field environment. To satisfy the test's goal, the mechanical stresses must be replicated. Structural dynamic testing is commonly executed on a shaker table or a shock apparatus such as a drop table or a resonant plate. These apparatus impart a force or load on the component through a test fixture that connects the unit under test to the apparatus. Because the test fixture is directly connected to the unit under test, the fixture modifies the structural dynamics of the system, thus varying the locations and relative levels of stress on the unit under test. This may lead to a false positive or negative indication if the unit under test will fail in its field environment depending on the environment and the test fixture. This body of research utilizes topology optimization using the Plato software to design a test fixture that attaches to the unit under test that matches the dynamic impedance of the next level of assembly. The optimization's objective function is the difference between the field configuration and the laboratory configuration's frequency response functions. It was found that this objective function had many local minima and posed difficulties in converging to an acceptable solution. A case study is presented that uses this objective function and although the results are not perfect, they are quantifiably better than the current method of using a sufficiently stiff fixture.

42 ENGINEERING↗

A Novel Rotating Flexure-Test Technique for Brittle Materials with Circular Geometries

The four-point bend test is one of the simplest and often the preferred flexural strength evaluation method for brittle materials. In this loading mode, fracture often initiates from a critical surface (or subsurface) flaw when subjected to a tensile stress state. However, if the critical flaw exists on the compression side of the test specimen, it may not activate to grow a crack and hence the resulting flexural strength will be higher than the true value. The goal of this study is to measure the true flexural strength of a solid or hollow cylindrical brittle specimen by ensuring that failure occurs at its weakest point by rotating along its longitudinal axis, thereby exposing and activating its critical surface flaw during a four-point bend test. A novel test fixture has been designed and fabricated, and the true flexural strengths of cylindrical brittle and quasi-brittle tubular specimens have been measured and compared to existing experimental data obtained through traditional four-point bend tests. In this work, experimental results showcase the orientation dependance on flexural strength for various materials. Additionally, similarities between experimental findings and those available in literature, including observations of fracture surfaces and relationships between surface roughness and material strength, are discussed.

36 MATERIALS SCIENCE↗

Testing, Characterization, and Modeling of the Resonant Plate Test Environment

The resonant plate shock test is a dynamic test of a mid-field pyroshock environment where a projectile is struck against a plate. The structure undergoing the simulated field shock is mounted to the plate. The plate resonates when struck and provides a two sided shock that is representative of the shock observed in the field. This test environment shock simulates a shock in a single coordinate direction for components looking to provide evidence that they will survive a similar or less shock when deployed in their operating environment. However, testing in one axis at a time provides many challenges. The true environment is a multi-axis environment. The test environment exhibits strong off-axis motion when only motion in one axis is desired. Multiple fixtures are needed for a single test series. It would be advantageous if a single test could be developed that tests the multi-axis environment simultaneously. In order to design such a test, a model must be developed and validated. The model can be iterated in design and configuration until the specified multi-axis environment is met. The test can then execute the model driven test design. This report discusses the resonant plate model needed to design future tests and the steps and methods used to obtain the model. This report also details aspects of the resonant plate test discovered during the process of model development that aids in our understanding of the test.

42 ENGINEERING↗

Design studies for the transmission simulator method of experimental dynamic substructuring.

In recent years, a successful method for generating experimental dynamic substructures has been developed using an instrumented fixture, the transmission simulator. The transmission simulator method solves many of the problems associated with experimental substructuring. These solutions effectively address: (1) rotation and moment estimation at connection points; (2) providing substructure Ritz vectors that adequately span the connection motion space; and (3) adequately addressing multiple and continuous attachment locations. However, the transmission simulator method may fail if the transmission simulator is poorly designed. Four areas of the design addressed here are: (1) designating response sensor locations; (2) designating force input locations; (3) physical design of the transmission simulator; and (4) modal test design. In addition to the transmission simulator design investigations, a review of the theory with an example problem is presented.

42 ENGINEERING↗

The Elusive “Life” of LEDs: How TM-21 Contributes to the Solution

This magazine article discusses the issue of LED 'lifetime' and explains where TM-21 plays as part of the solution to this issue. In August 2011, the Illuminating Engineering Society (IES) published the TM-21 document entitled 'Lumen degradation lifetime estimation method for LED light sources.' TM-21 is the IES-recommended method for projecting lumen degradation of an LED package, array or module based on data collected according to LM-80. The lighting community expects TM-21 to become the standard method for projecting useful LED lighting product life at realistic operating temperature. This article presents the development process behind TM-21, and clarifies how and when to apply the lifetime extrapolation method to arrive at reasonable and useful estimations. Why TM-21 and why now? We are all familiar with the very real but sometimes exaggerated long-life attributes of LED technology. Not the least of these is the potential for very long life that helps make it an attractive design choice. The trick has been and continues to be how to measure or estimate this longevity to provide assurance to users of this technology's reliability (life) compared to other options. We also understand that the overall reliability of a complete LED lighting fixture can be affected by the reliability of individual product components (driver, lens, etc.) and should be accounted for in lifetime estimations. The useful life of standard lighting technologies is defined as the time to filament or cathode failure. For most of these lamps, the time period prior to failure exhibits acceptable levels of light output, as shown with the solid lines in Fig. 1. This makes it easy to determine when to replace the lamp. However, LEDs do not have filament burn-out that conveniently announces the end of life (dashed line in Fig. 1). Further, the rapid development of the technology and the desire to bring products to market in a timely manner does not allow for actual testing verification of the long lives claimed (100,000 or even 35,000 hours). As a result, the industry has come to accept a definition of the end of the useful life of an LED as the point when it no longer provides a specified level of light output. And finally, the life and performance of LED lighting products depends greatly on excess heat retained at the diode. This is why LEDs require testing at multiple temperatures such that when a source is installed in a luminaire, its actual operating temperature can be measured and lumen depreciation of the product can be derived. Therefore, to serve the solid-state lighting industry, the Technical Procedures Committee (TPC) of the IES proceeded to develop appropriate tests for use in rating LED product longevity. The initial need was a measure of the basic lumen degradation of LED source components identified by a module, package, or array of diodes and this came in the form of LM-80. Importantly, LM-80 only specifies how to measure lumen depreciation to a minimum of 6000 hours (but recommends testing to 10,000 hours or longer). LM-80 stops short of using that data to estimate any depreciation after that, which is where TM-21 comes in. The TM-21 working group (WG) as part of the IES TPC was formed to develop the lumen depreciation projection method and spent over three years exploring many options. The WG evaluated various projection options starting with an analysis of various mathematical, engineering-based models to provide effective depreciation fit and a useful projection method. Next, the WG analyzed LED lumen maintenance behavior using over 40 sets of LM-80-08 test data (20 sets with 10,000 hours or more) collected from four major LED manufacturers. The working group also examined the accuracy of proposed projections using various proposed models and LM-80 data that extended up to 15,000 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Improved Sub-component Fatigue Testing Method for Material Characterization

In this paper an improved sub-component fatigue testing method is proposed, in which structural optimization is used to obtain specimens in which fatigue failure is precipitated in the designated area away from the boundaries, i.e., load application and fixture points. This is achieved by optimizing the nonlinear beam taper and the dynamic excitation. The major requirement for accurate material characterization through sub-component tests concerns unbiased stress states in the gauge section. However, empiricism shows that many sub-component high-cycle fatigue testing methods suffer from failure in the boundaries rather than the gauge section, which causes bias. The common practice for reinforcing those regions only shifts the issue into new areas of local discontinuities where failure is still caused remotely from the gauge section. An experimental proof of concept demonstrates that optimization of the beam taper can be used to obtain unbiased fatigue test data.

42 ENGINEERING↗

Aging Behavior of the Viton® Fluoroelastomer O-Rings in the 9975 Shipping Package

The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basis to extend that period. This paper describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior and leak performance. The CSR behavior of O-rings was evaluated at temperatures from 79 °C to 177 °C. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 75 °C). O-rings were also aged in Primary Containment Vessel (PCV) fixtures at temperatures ranging from 79 °C to 232 °C. The fixtures are helium leak tested periodically to determine if they remain leak-tight. The PCV fixture tests demonstrate that the 9975 O-rings will remain leak-tight at temperatures up to 149 °C for 3 years or more, and no leak failures have been observed with up to 8 years aging at 93 °C. Significantly longer periods of leak-tight service are expected at the lower temperatures actually experienced in the storage environment. The predictive model developed from the CSR data conservatively indicates a service life of more than 20 years at the bounding temperature of 75 °C. Although the relationship between CSR behavior and leak-tight performance has not been established for this design, the CSR predictions for this O-ring are conservative relative to leak-tight performance to date.

36 MATERIALS SCIENCE↗

Research three-dimensional hierarchical graphite architectures for anodes for fast charging

With current lithium ion batteries optimized for performance under relatively low charge rate conditions, implementation of XFC has been hindered by drawbacks including Li plating, kinetic polarization, and heat dissipation. This project will utilize model-informed design of 3-D hierarchical electrodes to tune key XFC related variables like 1) bulk porosity/tortuosity 2) vertical pore diameter, spacing, and lattice 3) crystallographic orientation of graphite particles relative to exposed surfaces 4) interfacial chemistry of the graphite surfaces through "artificial sEr formation using ALD 5) current collector surface roughness (aspect ratio, roughness factor, etc.). A key aspect of implementing novel electrodes is characterizing them in relevant settings. For this project, ultimately led out of University of Michigan by Neil Dasgupta, that includes both coin cell and 2+ Ah pouch cell testing, as well as comparison testing against baselines. Sandia National Labs will be conducting detailed cell characterization on iterative versions/improvements of the model-based hierarchical electrodes, as well as COTS cells for baseline comparisons. Key metrics include performance under fast charge conditions, as well as the absence or degree of lithium plating. Sandia will use their unique high precision cycling and rapid EIS capabilities to accurately characterize performance and any lithium plating during 6C charging and beyond, coupling electrochemical observations with cell teardown. Sandia will also design custom fixturing to cool cells during rapid charge, to decouple any kinetic effects brought about by cell heating and allow comparisons between different cells and charge rates. Using these techniques, Sandia will assess HOH electrodes from the University of Michigan, as well as aiding in iterative model and electrode design.

25 ENERGY STORAGE↗

Research three-dimensional hierarchical graphite architectures for anodes for fast charging

With current lithium ion batteries optimized for performance under relatively low charge rate conditions, implementation of XFC has been hindered by drawbacks including Li plating, kinetic polarization, and heat dissipation. This project will utilize model-informed design of 3-D hierarchical electrodes to tune key XFCrelated variables like 1) bulk porosity/tortuosity 2) vertical pore diameter, spacing, and lattice 3) crystallographic orientation of graphite particles relative to exposed surfaces 4) interfacial chemistry of the graphite surfaces through "artificial sEr' formation using ALD 5) current collector surface roughness (aspect ratio, roughness factor, etc.). A key aspect of implementing novel electrodes is characterizing them in relevant settings. For this project, ultimately led out of University of Michigan by Neil Dasgupta, that includes both coin cell and 2+ Ah pouch cell testing, as well as comparison testing against baselines. Sandia National Labs will be conducting detailed cell characterization on iterative versions/improvements of the model-based hierarchical electrodes, as well as COTS cells for baseline comparisons. Key metrics include performance under fast charge conditions, as well as the absence or degree of lithium plating. Sandia will use their unique high precision cycling and rapid EIS capabilities to accurately characterize performance and any lithium plating during 6C charging and beyond, coupling electrochemical observations with cell teardown. Sandia will also design custom fixturing to cool cells during rapid charge, to decouple any kinetic effects brought about by cell heating and allow comparisons between different cells and charge rates. Using these techniques, Sandia will assess HOH electrodes from the University of Michigan, as well as aiding in iterative model and electrode design.

25 ENERGY STORAGE↗

Kinematic fixtures to enable multi-material printing and rapid non-destructive inspection during two-photon lithography

Here, two-photon lithography (TPL) is a polymerization based technique that enables additive manufacturing of millimeter scale parts with submicron features. TPL equipment is often based on retrofitted optical microscopes that lack precise registration capabilities. Consequently, slow and error-prone visual alignment to fiducials is necessary if registration to pre-existing features is required. Herein, we have designed, built, and tested precise kinematic fixtures that are repeatable to within ±315 nm (3σ value) and passively register the build surface to TPL equipment with an accuracy of ±1.7 μm. This enables one to sequentially print with multiple materials by building the structures directly on top of the kinematic fixtures. In addition, the same fixtures passively register to an X-ray computed tomography (CT) system to enable non-destructive 3D inspection that is integrated with the fabrication process. These fixtures (i) provide a practical means to handle micro-scale parts during non-destructive imaging, (ii) reduce the set-up time for X-ray CT from more than an hour to less than a few minutes, and (iii) eliminate operator uncertainty from the multi-material printing and imaging process. As such, these fixtures enable new printing and imaging functionalities that are critical for high-quality additive manufacturing of multi-material polymer parts with microscale and submicron features.

42 ENGINEERING↗

Preliminary Report: Effects of Irradiation and Thermal Exposure on Elastomeric Seals for Cask Transportation and Storage

A testing and analysis approach to predict the sealing behavior of elastomeric seal materials in dry storage casks and evaluate their ability to maintain a seal under thermal and radiation exposure conditions of extended storage and beyond was developed, and initial tests have been conducted. The initial tests evaluate the aging response of EPDM elastomer O-ring seals. The thermal and radiation exposure conditions of the CASTOR® V/21 casks were selected for testing as this cask design is of interest due to its widespread use, and close proximity of the seals to the fuel compared to other cask designs leading to a relatively high temperature and dose under storage conditions. A novel test fixture was developed to enable compression stress relaxation measurements for the seal material at the thermal and radiation exposure conditions. A loss of compression stress of 90% is suggested as the threshold at which sealing ability of an elastomeric seal would be lost. Previous studies have shown this value to be conservative to actual leakage failure for most aging conditions. These initial results indicate that the seal would be expected to retain sealing ability throughout extended storage at the cask design conditions, though longer exposure times are needed to validate this assumption. The high constant dose rate used in the testing is not prototypic of the decreasingly low dose rate that would occur under extended storage. The primary degradation mechanism of oxidation of polymeric compounds is highly dependent on temperature and time of exposure, and with radiation expected to exacerbate the oxidation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RLUOB Celebration

Los Alamos National Laboratory's newest facility, the Radiological Laboratory Utility Office Building (RLUOB), is also its first to achieve both the Leadership in Energy and Environmental Design (LEED) status and LEED Gold certification from the U.S. Green Building Council (USGBC). From its robust design to its advanced scientific equipment, RLUOB is essential to the Laboratory's national security mission in support of the National Nuclear Security Administration's (NNSA) nuclear weapons program. At more than 200,000 square feet, this building is the only radiological facility within the Department of Energy to have attained LEED Gold, which contributes to NNSA's achievement towards the high performance sustainable building goals outlined in Executive Order 13514, Federal Leadership in Environmental, Energy, and Economic Performance. 'As we celebrate RLUOB being completed almost one year ahead of schedule and having achieved LEED certification at the Gold level, we approach our plutonium mission at Los Alamos and NNSA with a great sense of achievement,' said Don Cook, NNSA's deputy administrator for defense programs. 'RLUOB adds a major component to NNSA's plutonium support capability and RLUOB demonstrates our commitment in helping to deliver President Obama's nuclear security agenda which includes ensuring the safety, security and effectiveness of the nuclear deterrent without testing.' The facility contains laboratories for analytical chemistry and materials characterization of special nuclear material, along with space for offices, training and emergency operations. Its multi-functional purpose makes RLUOB a unique project for which LEED certification was sought. 'LEED certification was a huge goal and one we sought from the very beginning of this project,' said Laboratory Director Charlie McMillan. 'It's an important step forward, allowing us to advance national security science in modern, safer, more efficient infrastructure.' The Laboratory's project team and its contractor partners, especially in coordination with Jacobs Engineering, focused on green design and construction in LEED categories, such as sustainable sites, water efficiency, energy and atmosphere, materials and resources, indoor environmental quality and innovation in design. RLUOB's features include: (1) Building envelope design (orientation, materials and insulation) yielded a 20 percent improvement in energy performance; (2) Incorporation of building materials with 24 percent recycled content; (3) Diversion of 72 percent of construction-generated materials through reuse, recycle and salvage; (4) Roofing comprised of 93 percent highly-reflective materials to reduce heat island effects; (5) High efficiency, gas-fired hot water boilers, air-cooled chillers, thermal storage systems and variable frequency drives for compressors, fans and pumps; (6) Energy efficient lighting for interiors, exteriors, process glove boxes and fume hoods; (7) Water efficient fixtures resulting in 30 percent reduction in usage; (8) Low emission paints and carpeting for improved indoor air quality; (9) Landscaping that doesn't require permanent irrigation; (10) Enhanced building system commissioning; and (11) Comprehensive transportation alternatives, including public transportation, bicycle storage and changing rooms, and a refueling station for government vehicles using alternative fuels. 'RLUOB's LEED certification demonstrates tremendous leadership in green building,' says Rick Fedrizzi, president and CEO of USGBC. 'The urgency of our mission has challenged the industry to move faster and reach further than ever before, and RLUOB serves as a prime example of just how much we can accomplish.'

25 ENERGY STORAGE↗

Research, Development and Demonstration of Micro-CHP System for Residential Applications

ECR International and its joint venture company, Climate Energy, are at the forefront of the effort to deliver residential-scale combined heat and power (Micro-CHP) products to the USA market. Part of this substantial program is focused on the development of a new class of steam expanders that offers the potential for significantly lower costs for small-scale power generation technology. The heart of this technology is the scroll expander, a machine that has revolutionized the HVAC refrigerant compressor industry in the last 15 years. The liquid injected cogeneration (LIC) technology is at the core of the efforts described in this report, and remains an excellent option for low cost Micro-CHP systems. ECR has demonstrated in several prototype appliances that the concept for LIC can be made into a practical product. The continuing challenge is to identify economical scroll machine designs that will meet the performance and endurance requirements needed for a long life appliance application. This report describes the numerous advances made in this endeavor by ECR International. Several important advances are described in this report. Section 4 describes a marketing and economics study that integrates the technical performance of the LIC system with real-world climatic data and economic analysis to assess the practical impact that different factors have on the economic application of Micro-CHP in residential applications. Advances in the development of a working scroll steam expander are discussed in Section 5. A rigorous analytical assessment of the performance of scroll expanders, including the difficult to characterize impact of pocket to pocket flank leakage, is presented in Section 5.1. This is followed with an FEA study of the thermal and pressure induced deflections that would result from the normal operation of an advanced scroll expander. Section 6 describes the different scroll expanders and test fixtures developed during this effort. Another key technical challenge to the development of a long life LIC system is the development of a reliable and efficient steam generator. The steam generator and support equipment development is described in Section 7. Just one year ago, ECR International announced through its joint venture company, Climate Energy, that it was introducing to the USA market a new class of Micro-CHP product using the state-of-the-art Honda MCHP gas fired internal combustion (IC) engine platform. We now have installed Climate Energy Micro-CHP systems in 20 pilot demonstration sites for the 2005/2006 heating season. This breakthrough success with IC engine based systems paves the way for future advanced steam cycle Micro-CHP systems to be introduced.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical Design and Fabrication of a New RF Power Amplifier for LANSCE

A Full-scale prototype of a new 201.25 MHz RF Final Power Amplifier (FPA) for Los Alamos Neutron Science Center (LANSCE) has been designed, fabricated, assembled and installed in the test facility. This prototype was successfully tested and met the physics and electronics design criteria. The team faced design and manufacturing challenges, having a goal to produce 2 MW peak power at 13% duty factor, at the elevation of over 2 km in Los Alamos. The mechanical design of the final power amplifier was built around a Thales TH628 Diacrode{sup R}, a state-of-art tetrode power tube. The main structure includes Input circuit, Output circuit, Grid decoupling circuit, Output coupler, Tuning pistons, and a cooling system. Many types of material were utilized to make this new RF amplifier. The fabrication processes of the key components were completed in the Prototype Fabrication Division shop at Los Alamos National Laboratory. The critical plating procedures were achieved by private industry. The FPA mass is nearly 600 kg and installed in a beam structural support stand. In this paper, we summarize the FPA design basis and fabrication, plating, and assembly process steps with necessary lifting and handling fixtures. In addition, to ensure the quality of the FPA support structure a finite element analysis with seismic design forces has also been carried out.

Accelerator Design, Technology, and Operations↗

High power s-band vacuum load

Through a combination of experimentation and calculation the components of a novel room temperature dry load were successfully fabricated. These components included lossy ceramic cylinders of various lengths, thicknesses, and percent of silicon carbide (SiC). The cylinders were then assembled into stainless steel compression rings by differential heating of the parts and a special fixture. Post machining of this assembly provided a means for a final weld. The ring assemblies were then measured for S-parameters, individually and in pairs using a low-cost TE10 rectangular to TE01 circular waveguide adapter specially designed to be part of the final load assembly. Matched pairs of rings were measured for assembly into the final load, and a sliding short designed and fabricated to assist in determining the desired short location in the final assembly. The plan for the project was for Muons, Inc. to produce prototype loads for long-term testing at SLAC. The STTR funds for SLAC were to upgrade and operate their test station to ensure that the loads would satisfy their requirements. Phase III was to be the sale to SLAC of loads that Muons, Inc. would manufacture. However, an alternate solution that involved a rebuild of the old loads, reduced SLAC budget projections, and a relaxed time for the replacement of all loads meant that in-house labor will be used to do the upgrade without the need for the loads developed in this project. Consequently, the project was terminated before the long term testing was initiated. However, SLAC can use the upgraded test stand to compare the long-term performance of the ones produced in this project with their rebuilt loads when they are available.

42 ENGINEERING↗

Robotic Assisted Non-Destructive Testing (NDT)

Mission Statement: Concrete wall characterization for structural integrity evaluation of H-Canyon exhaust tunnel using a remote controlled robotic arm with a NDT Concrete Instrument. Challenges: Rough and Curved Surfaces, Remote location. The UR5 is a collaborative robotic arm capable of: Payload: 11 lbs (5 kg), Reach: 33.5 in (850 mm), Footprint: 5.87 in (149 mm) diameter, Weight: 45.4 Ibs (20.6 kg). The force torque sensor reacts to a set value inputted by the user that can be utilized for sensitive products. This allows the UR5 to react to surfaces using the built-in function to search for a wall and orient itself normal to that plane. The Proceq Pundit 250 array is a nondestructive device that the user applies against a concrete wall and scans using ultrasonic transducers. The back wall and other defects can be show through the touchscreen. A fixture to hold the Proceq Pundit 250 array onto the UR5 robotic arm was designed and 3D printed. It includes openings for easy access to the buttons from the Pundit array as well as a reinforced structural design. The scan from the Pundit array can show the back-wall, rebars, and other defects to assist in determining the structural integrity. In order to scan, a program was made to search for the wall first. 1. The UR5 robotic arm will go to the desired location away from the wall. 2. It will then search for the wall by moving towards it slowly. 3. After contact, the force applied will slowly but steadily increase to a preset value inputted by the user. 4. The force torque sensor will use those values and communicate with the UR5 by adjusting the arm to become normal to the wall. 5. The arm will then apply force to push back the transducers on the Pundit array to avoid gaps. 6. It will then prompt the user to collect data and wait until finished. The UR5 teach pendant allows the user to program the robot to perform automated and repeatable tasks. It includes a free drive mode which allows the user to move the arm to a desired position by hand. The user can also apply restricted planes which include either stopped or slower motion to ensure safety. The concrete sample being tested includes rebars and different grades of surface roughness to understand the readings from the Proceq Pundit 250 array. Desired concrete samples are currently being fabricated that will simulate the terrain being tested.

3D PRINTING↗

Aging Behavior of Viton{sup R} O-Ring Seals in the 9975 Shipping Package - 12594

The Savannah River Site (SRS) is storing plutonium (Pu) materials in the K-Area Materials Storage (KAMS) facility. The Pu materials were packaged according to the DOE-STD-3013 standard and shipped to the SRS in Type B 9975 packages. The robust 9975 shipping package was not designed for long-term product storage, but it is a specified part of the storage configuration and the KAMS facility safety basis credits the 9975 design with containment. Within the 9975 package, nested stainless steel containment vessels are closed with dual O-ring seals based on Viton{sup R} GLT or GLT-S fluoro-elastomer. The aging behavior of the O-ring compounds is being studied to provide the facility with advanced notice of nonconformance and to develop life prediction models. A combination of field surveillance, leak testing of surrogate fixtures aged at bounding service temperatures, and accelerated-aging methodologies based on compression stress-relaxation and oxygen consumption analysis is being used to evaluate seal performance. A summary of the surveillance program relative to seal aging behavior is presented. The aging behavior of fluoro-elastomer seals based on Viton{sup R} GLT and GLT-S is being studied to develop life prediction models in support of long-term storage of plutonium materials in the 9975 shipping packages at the Savannah River Site. Field surveillance data in combination with accelerated-aging data suggest a significant lifetime for the seals. Typical storage conditions are not anticipated to challenge the leak-tightness of the seals for many years. Early life prediction models based on compression stress relaxation indicate a seal lifetime of ∼12 years at the maximum service temperature predicted (93 deg. C). Seal lifetimes at lower, more realistic conditions are likely significantly longer. Service life predictions based on CSR data are thus far conservative relative to predictions based on time to leakage failure. Surveillance data on packages examined after 6 years in storage show only minor compression set of the O-rings and no significant degradation. Surveillance and testing will continue as needed to validate and refine life prediction models. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗