Final Technical Report, Comport: Rigorous Testing Methods to Safeguard Software Porting
Final report for Comport grant.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Final report for Comport grant.
Explore the source record for details and available documents.
The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.
ANSI/ASHRAE Standard 140 Method of Test for Evaluating Building Performance Simulation Software specifies the method to test the core competency of building performance simulation (BPS) software, a broad class of software which includes building energy modeling (BEM) software. Standard 140 has been widely used by BEM software vendors to help diagnose and compare the results from the program with other modeling programs. The Standard is also referenced by codes, standards, government programs, and other incentive programs as a part of minimum requirements for qualifying BEM software. The explanatory information, summary tables and figures in this 140 User’s Manual (referred to as “this Manual”) are provided to help users in implementing various suites of tests specified in Standard 140-2023 (referred to in this manual as “Standard 140” or “the Standard”).
Surface biofouling reduces the efficiency and lifespan of equipment across many industries. The development of high-performance antifouling surfaces, such as foul release coatings, benefits from test methods that can quickly identify superior antifouling surfaces in the laboratory during material development. Existing test methods poorly discriminate between different foul release coatings. Here is presented a method to assess the ability of surfaces to resist mussel adhesion using a quantitative, controlled single thread adhesion test (STAT) method, allowing for meaningful comparisons between low adhesion foul release surfaces. This method provides greater accuracy and finer resolution than push-based mussel shear adhesion methods without the difficulties associated with mussel size, thread attachment angle, or harming the mussels. The single thread tensile method is demonstrated on a variety of standard and high-performance coatings, and it is shown that the method detects differentiation between commercial foul release coatings that could not be resolved using other methods.
Extensive research has been conducted on the sulfate attack of concrete structures; however, the need to adopt the use of more sustainable materials is driving a need for a quicker test method to assess sulfate resistance. This work presents accelerated methods that can reduce the time required for assessing the sulfate resistance of mixtures by 70%. Class F fly ash has historically been used in concrete mixtures to improve sulfate resistance. However, environmental considerations and the evolving energy industry have decreased its availability, requiring the identification of economically viable and environmentally friendly alternatives to fly ash. Another challenge in addressing sulfate attack durability issues in concrete is that the standard sulfate attack test (ASTM C1012) is time-consuming and designed for only standard mortars (not concrete mixtures). To expedite the testing process, accelerated testing methods for both mortar and concrete mixtures were adopted from previous work to further the development of the accelerated tests and to assess the feasibility of testing the sulfate resistance of mortar and concrete mixtures rapidly. This study also established criteria for interpreting sulfate resistance for each of the test methods used in this work. A total of 14 mortar mixtures and four concrete mixtures using two types of Portland cement (Type I and Type I/II) and various supplementary cementitious materials (SCMs) were evaluated in this study. The accelerated testing methods significantly reduced the evaluation time from 12 months to 21 days for mortar mixtures and from 6 months to 56 days for concrete mixtures. The proposed interpretation method for mortar accelerated test results showed acceptable consistency with the ACI 318-19 interpretations for ASTM C1012 results. The interpretation methods proposed for the two concrete sulfate attack tests demonstrated excellent consistency with the ASTM C1012 results from mortar mixtures with the same cementitious materials combinations. Metakaolin was shown to improve sulfate resistance for both mortar and concrete mixtures, while silica fume and natural pozzolan had a limited impact. Using 15% metakaolin in mortar or concrete mixtures with Type I/II cement provided the best sulfate resistance.
Controlling indoor humidity levels is essential for maintaining acceptable indoor air quality in buildings. The use of energy recovery ventilators (ERVs) is an energy-efficient way to regulate indoor air humidity. Fixed-bed regenerators and rotary wheels are widely used ERVs because of their high sensible and latent effectiveness. These ERVs are made of desiccant-coated substrates, which enable them to transfer moisture between the supply and exhaust air streams. However, the moisture transfer ability of ERVs depends on the physiochemical and sorption properties of desiccants. Extensive, full-scale experiments are required to determine the best desiccant material for these systems. This paper presents a simplified method of selecting suitable desiccant materials for ERVs. The methodology involves important characterization methods, literature correlations for performance prediction, and cost-effective testing methods prior to full-scale testing, and full-scale test methods are discussed in detail. Furthermore, the performance of a few newly derived materials is evaluated and compared with that of conventional desiccants such as silica gel and molecular sieves. The highest latent effectiveness was obtained for composite of super absorbent polymer (SAP) with potassium formate (SAP-HCO2K-50 %), all-polymer porous solid desiccant (APPSD) and metal organic framework (MOF)–MIL–101 (Cr), followed by activated carbon fibre felt (ACFF) Silica sol-LiCl30, SAP, silica gel, MOF–303, and molecular sieve. Researchers and manufacturers would benefit from the proposed methodology and presented data in developing new desiccant materials for ERV applications.
Additive manufacturing (AM) is a rapidly growing technology space, not only for prototyping, but is also becoming more feasible at larger scales and increasing component quantities. There are a large variety of AM processes and materials available to users and effectively applying those processes and materials to a specific use case can be challenging. One specific area where AM could be particularly beneficial is marine renewable energy (MRE). Not only is MRE a relatively nascent industry with a near-term need for rapid deployments and prototype testing, but developers could also see long-term benefits from the broad variety of environmentally resistant materials available and the ability to manufacture complex geometries that AM technologies offer. Over the past 4 years, AM materials have played an increasing role in the Advanced Materials project; a multi-year, multi-laboratory research project funded by the U.S. Department of Energy's Water Power Technologies Office, with the main goal of reducing barriers to the adoption of complex materials in the MRE industry. The primary focus of this project is to develop test methods and generate datasets to understand the long-term performance of advanced materials in marine environmental and address specific material challenges as they arise. This report provides an extensive overview of the research that has been performed specific to AM polymers as part of the Advanced Materials project. The intention of this document is to provide recommendations of best practices with regards to material selection, mechanical test method development, and design practices, lessons learned along the way, current research trends, and ongoing challenges with regards to AM polymers in marine environments. In particular, this report focuses on several key aspects: Material and process selection, Environmental conditioning and subsequent degradation quantification through mechanical characterization, Composite reinforcements on AM polymer substrates, Adhesion of instrumentation for mechanical characterization and loads measurements, Protective coatings for preventing biofouling and water ingress, Other MRE case studies where AM has proved particularly useful. Ultimately, we hope that the test methods that have been developed, data generated, and lessons learned from this research will be valuable to the MRE community (researchers and developers alike), as well as other industries, and can be used as a reference point as the respective MRE and AM industries continue to grow and mature.
This thesis studies drop durability of electronic assemblies when the acceleration vector is oriented at 45° to the out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field environments during ground-based laboratory testing. However, many of these test methods require expensive and specialized equipment not available in most laboratories. An alternative approach for approximating simultaneous loading along multiple axes on conventional equipment utilizes skewed fixtures which have seen use in off-axis random vibration and drop impact testing. These methods generally rely on the conversion of a uniaxial input load from the test equipment (using a uniaxial drop tower or shaker) into a multiaxial load when resolved in the reference frame of the test article (mounted on a skewed fixture). Skewed fixture design is presented and recommendations for conducting skewed angle drop testing are introduced based on local measurements along the skewed face of the fixture to accurately monitor the impact event. Characterization tests were performed with a skewed fixture, at simultaneous acceleration loads from 500 to 3,000 g in two (in-plane and out-of-plane) directions, while meeting standard time domain tolerances. Upon experimental characterization, drop shock durability tests were conducted on a printed circuit assembly (PCA). Mean drops-to-failure were measured and quantified with Weibull statistics. Dominant solder joint failure modes were identified via failure analysis. Prior work on inclined angle impact testing is limited, and the majority of solder joint interconnect level fatigue studies are conducted considering perpendicular loading normal the circuit card. Low-cycle fatigue curves are generated based on plastic strain and plastic work density within the solder joint. A multiscale nonlinear finite element model is used to relate board-level flexure to solder joint interconnect level plastic strain. A high strain rate solder constitutive model allows for accurate modeling of solder plasticity resulting from high-impact drop shock. Fatigue parameters are computed from the Coffin-Manson relation and Palmgren-Miner damage accumulation. This work serves to apply established low-cycle fatigue methods for conventional drop shock loading (impact normal to circuit card) to non-perpendicular loading with a skewed fixture.
Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.
Hydropower is undergoing technological innovation as future development increasingly targets low-head sites (<10 m), primarily through retrofits, rehabilitation, and upgrades of existing infrastructure. This shift toward smaller systems creates a timely opportunity: unlike conventional large projects, many emerging low-head technologies may be small enough for direct full-scale validation. Full-scale testing is particularly important for environmental mitigation technologies, including fish passage, sediment continuity, and water-quality improvements, whose performance is difficult to assess reliably using reduced-scale models. Yet adoption remains constrained by the limited risk-bearing capacity of small hydropower owners, discouraging manufacturers from bringing unvalidated technologies to market. This review and perspective paper examines hydropower trends driving innovation, selected emerging technologies, conventional testing methods, and current U.S. testing capabilities as a case study. We then evaluate the gap between existing capabilities and the needs of low-head powertrains and environmental mitigation measures. Many technologies exceed existing facility flow capacities; in the U.S., the highest combined head–flow capability is limited to 5.66 m3/s, compared with median and 90th-percentile low-head turbine-unit flows of 14.3 and 60 m3/s. To mitigate this gap, we advocate repurposing large, retired, or underused hydraulic infrastructure as full-scale testing facilities to reduce first-adoption risk and support sustainable low-head hydropower deployment.
The expanding foil photoionized plasma platform was developed on the Z-machine at Sandia National Laboratories to produce terrestrial photoionized plasmas at some of the same conditions as those observed in astrophysical black hole accretion disks. The specific scientific goals of the platform are motivated by long-standing astrophysical puzzles related to accreting black hole systems. Ultimately, the experimental goal is to inform the supersolar Fe abundance problem by testing photoionized plasma models in emission with at-parameter laboratory data. High quality high resolution emission data with absolute intensity calibration from a laboratory photoionized plasma have never been collected prior to the experiments described here, providing broader motivation. A robust test of the model predictions requires the successful production of a laboratory photoionized plasma along with measurements of the supporting model inputs including the radiation drive spectrum used to create the photoionized plasma, the electron density, and the temperature. The measured absolute spectral radiance in emission collected from the independently diagnosed plasma can be compared against model calculations performed using the measured inputs. In this paper, we focus on the experimental platform and the model inputs, specifically detailing the methodology used to measure the plasma conditions. The moderate electron temperature of ∼41 eV ± 15 eV and electron density of ∼1e19 ± 1.6e18 e−/cm3 and the ∼3e12 W/cm2 x-ray irradiance at the sample confirm that photoionization dominates the plasma ionization and spectra.
The major goal of the project is the construction and operation of an electromagnetic isotope separator. Included in that goal is the construction and installation of a high throughput surface ion source, with specific applicability to the Lanthanides. The surface ion source features a single-piece titanium crucible insert that mates with a tantalum hot surface ionizer. The titanium crucible, which does not readily activate, can be loaded with samarium and then irradiated simultaneously, greatly reducing operator dose.
Accelerated weathering and material compatibility testing for polymeric and asphaltic materials. NLR will be testing the durability of the polymeric materials proposed for use in the supporting structures designed by TESCI solar. This will include the bare materials and coupons attached to asphalt shingles. The exposure will be in damp heat and separately heat, humidity and UV light, all followed by mechanical evaluation. Modification 1 is an extension of the first round of testing with both a continuation of some of the same testing and addition of new testing methods and materials. The testing of materials in the condition of A3 looking at mechanical durability will be continued looking at the materials used in the mounting brackets. We will be adding in testing of the silicone adhesive to the module and of the module itself. For the mounting brackets, testing will also be conducted at multiple temperatures and humidity levels to allow for extrapolation to the field.
Explore the source record for details and available documents.
Marine energy structures are typically made of advanced composite materials and are subjected to extreme ocean environments in service. In extreme ocean environments, seawater currents and waves load structures repeatedly, which cause two environmental conditions: water intrusion and mechanical fatigue. In prior research, the two environmental conditions were applied sequentially, where composite specimens were aged and then mechanically tested. To understand the combined effects of dynamic loading and water intrusion on composite materials, the present study involves the static and fatigue four-point bend testing of composite coupons in a water tank. The water tank was designed and built to fit either a 100 kN or a 250 kN load frame. Flexural strength value, cycles to failure, and failure mode results from submerged fatigue testing will be used to inform marine energy structure designs. The coupon-scale test method will be used to scale up to and inform methods for subsequent subcomponent testing and standards development. Finally, the benefits of designing marine energy structures to informed standards are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.
Hybridization events complicate the accurate reconstruction of phylogenies, as they lead to patterns of genetic heritability that are unexpected under traditional, bifurcating models of species trees. This phenomenon has led to the development of methods to infer these varied hybridization events, both methods that reconstruct networks directly, as well as summary methods that predict individual hybridization events from a subset of taxa. However, a lack of empirical comparisons between methods – especially those pertaining to large networks with varied hybridization scenarios – hinders their practical use. Here, we provide a comprehensive review of popular summary methods: TICR, MSCquartets, HyDe, Patterson’s D-Statistic (ABBA-BABA), D3, and Dp. TICR and MSCquartets are based on quartet concordance factors gathered from gene tree topologies and HyDe, Patterson’s D-Statistic, D3, and Dp use site pattern frequencies to identify hybridization events between sets of three taxa. We then use simulated data to address questions of method accuracy and ideal use scenarios by testing methods against complex networks which depict gene flow events that differ in depth (timing), quantity (single vs. multiple, overlapping hybridizations), and rate of gene flow (γ). We find that deeper or multiple hybridization events may introduce noise and weaken the signal of hybridization, leading to higher relative false negative rates across all methods. Despite some forms of hybridization eluding quartet-based detection methods, MSCquartets displays high precision in most scenarios. While HyDe results in high false negative rates when tested on hybridizations involving extinct or unsampled ghost lineages, HyDe is the only method able to identify the direction of hybridization, distinguishing the source parental lineages from recipient hybrid lineages. Lastly, we test the methods on a dataset of ultraconserved elements from the bee subfamily Nomiinae, finding possible hybridization events between clades which correspond to regions of poor support in the species tree estimated in a previous study.
It is known that the predictive life of the refractory ceramic liner of nuclear waste glass melters is conservative, as demonstrated by performance of these materials such as in the Defense Waste Processing Facility (DWPF). The motivation for this task is to maximize the useful life of the melters that will be operated at the Waste Treatment and Immobilization Plant (WTP), which will in turn minimize procurement and disposal costs and melter outage times, as well as to identify maximum loadings in the waste glass of those species that corrode melter components. This task was initiated jointly with Pacific Northwest National Laboratory (PNNL) with the objective to develop a methodology and model to enable more accurate prediction of refractory service life under prototypic conditions from laboratory-scale material corrosion tests. Refractory corrosion is generally reported as physical material loss, measured in units of distance (e.g., inch) or as physical material loss rate, measured in units of distance per time (e.g., inch/day). In post-operational melters, the refractory corrosion is measured directly, sometimes reported as corrosion depth. Crucible tests are used in the laboratory to accelerate the refractory corrosion to facilitate a meaningful measurement in a commensurate amount of time. Crucible tests are particularly useful in understanding refractory corrosion across a large glass composition space, where operational testing would be prohibitive. Some of the critical parameters that are known to influence refractory corrosion by molten glass in a crucible test are temperature, system redox, molten salt phases, glass chemistry, and test duration. The majority of data collected for Monofrax® K-3 (hereafter referred to as K-3) corrosion is from crucible tests, but a small amount comes directly from scaled and production melters. Crucible test data has been collected under varying conditions, whereas data collected from operational melters is relatively fewer and represents conditions specific to the melter campaign. The result is that the published data can be grouped and analyzed in multiple ways, not all of which are readily comparable. The Standard Test Method for Isothermal Corrosion Resistance of Refractories to Molten Glass (ASTM C621) outlines the general guidelines used across industry. That method describes a sealed, static test in which the surface area of the refractory coupon and the volume of glass are fixed. A significant portion of the crucible data pertaining to nuclear waste glasses has been collected in a modified configuration; the most notable differences being the surface area of the refractory coupon to volume of the glass and use of a method for bubbling the melt. To our knowledge, the influence of those parameters on the refractory corrosion has not been quantified. In this work, it was determined that static tests and bubbled tests would be performed. Savannah River National Laboratory (SRNL) was tasked with setting up and performing static testing while PNNL was tasked with setting up and performing bubbled testing. Initial activities were performed to establish laboratory methods that reproduce data comparable to existing data sets of K-3 refractory corrosion by low activity waste (LAW) and high-level waste (HLW) glass compositions. Later activities were focused on refining the test parameters to establish a standard test practice to be used between Laboratories and collecting additional data to be used in the enhanced waste glass model development. This document serves primarily to convey the refractory loss measurement results from corrosion testing of K-3 refractory with waste glass compositions developed for use in the WTP melters. The data will be used in the enhanced property/composition models being developed for waste glass vitrification and melter operations.