Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Energy Storage Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Applications of thermal energy storage in the cement industry

In the manufacture of cement, literally trillions of Btu's are rejected to the environment each year. The purpose of this feasibility study program was to determine whether thermal energy storage could be used to conserve or allow alternative uses of this rejected energy. This study identifies and quantifies the sources of rejected energy in the cement manufacturing process, established use of this energy, investigates various storage system concepts, and selects energy conservation systems for further study. Thermal performance and economic analyses are performed on candidate storage systems for four typical cement plants representing various methods of manufacturing cement. Through the use of thermal energy storage in conjunction with waste heat electric power generation units, an estimated 2.4 x 10 to the 13th power Btu/year, or an equivalent on investment of the proposed systems are an incentive for further development.

Jaeger, F. A.↗

Design of a cavity heat pipe receiver experiment

A cavity heat pipe experiment has been designed to test the critical issues involved with incorporating thermal energy storage canisters into a heat pipe. The experiment is a replication of the operation of a heat receiver for a Brayton solar dynamic power cycle. The heat receiver is composed of a cylindrical receptor surface and an annular heat pipe with thermal energy storage canisters and gaseous working fluid heat exchanger tubes surrounding it. Hardware for the cavity heat pipe experiment will consist of a sector of the heat pipe, complete with gas tube and thermal energy storage canisters. Thermal cycling tests will be performed on the heat pipe sector to simulate the normal energy charge/discharge cycle of the receiver in a spacecraft application.

Schneider, Michael G.↗

Impact of thermal energy storage properties on solar dynamic space power conversion system mass

A 16 parameter solar concentrator/heat receiver mass model is used in conjunction with Stirling and Brayton Power Conversion System (PCS) performance and mass computer codes to determine the effect of thermal energy storage (TES) material property changes on overall PCS mass as a function of steady state electrical power output. Included in the PCS mass model are component masses as a function of thermal power for: concentrator, heat receiver, heat exchangers (source unless integral with heat receiver, heat sink, regenerator), heat engine units with optional parallel redundancy, power conditioning and control (PC and C), PC and C radiator, main radiator, and structure. Critical TES properties are: melting temperature, heat of fusion, density of the liquid phase, and the ratio of solid-to-liquid density. Preliminary results indicate that even though overalll system efficiency increases with TES melting temperature up to 1400 K for concentrator surface accuracies of 1 mrad or better, reductions in the overall system mass beyond that achievable with lithium fluoride (LiF) can be accomplished only if the heat of fusion is at least 800 kJ/kg and the liquid density is comparable to that of LiF (1880 kg/cu m.

Juhasz, Albert J.↗

Impact of thermal energy storage properties on solar dynamic space power conversion system mass

A 16 parameter solar concentrator/heat receiver mass model is used in conjunction with Stirling and Brayton Power Conversion System (PCS) performance and mass computer codes to determine the effect of thermal energy storage (TES) material property changes on overall PCS mass as a function of steady state electrical power output. Included in the PCS mass model are component masses as a function of thermal power for: concentrator, heat receiver, heat exchangers (source unless integral with heat receiver, heat sink, regenerator), heat engine units with optional parallel redundancy, power conditioning and control (PC and C), PC and C radiator, main radiator, and structure. Critical TES properties are: melting temperature, heat of fusion, density of the liquid phase, and the ratio of solid-to-liquid density. Preliminary results indicate that even though overall system efficiency increases with TES melting temperature up to 1400 K for concentrator surface accuracies of 1 mrad or better, reductions in the overall system mass beyond that achievable with lithium fluoride (LiF) can be accomplished only if the heat of fusion is at least 800 kJ/kg and the liquid density is comparable to that of LiF (1800 kg/cu m).

Juhasz, Albert J.↗

High-temperature molten salt thermal energy storage systems

The results of comparative screening studies of candidate molten carbonate salts as phase change materials (PCM) for advanced solar thermal energy storage applications at 540 to 870 C (1004 to 1600 F) and steam Rankine electric generation at 400 to 540 C (752 to 1004 F) are presented. Alkali carbonates are attractive as latent heat storage materials because of their relatively high storage capacity and thermal conductivity, low corrosivity, moderate cost, and safe and simple handling requirements. Salts were tested in 0.1 kWhr lab scale modules and evaluated on the basis of discharge heat flux, solidification temperature range, thermal cycling stability, and compatibility with containment materials. The feasibility of using a distributed network of high conductivity material to increase the heat flux through the layer of solidified salt was evaluated. The thermal performance of an 8 kWhr thermal energy storage (TES) module containing LiKCO3 remained very stable throughout 5650 hours and 130 charge/discharge cycles at 480 to 535 C (896 to 995 F). A TES utilization concept of an electrical generation peaking subsystem composed of a multistage condensing steam turbine and a TES subsystem with a separate power conversion loop was defined. Conceptual designs for a 100 MW sub e TES peaking system providing steam at 316 C, 427 C, and 454 C (600 F, 800 F, and 850 F) at 3.79 million Pa (550 psia) were developed and evaluated. Areas requiring further investigation have also been identified.

Petri, R. J.↗

Experimental simulation of latent heat thermal energy storage and heat pipe thermal transport for dish concentrator solar receiver

Test results on a modular simulation of the thermal transport and heat storage characteristics of a heat pipe solar receiver (HPSR) with thermal energy storage (TES) are presented. The HPSR features a 15-25 kWe Stirling engine power conversion system at the focal point of a parabolic dish concentrator operating at 827 C. The system collects and retrieves solar heat with sodium pipes and stores the heat in NaF-MgF2 latent heat storage material. The trials were run with a single full scale heat pipe, three full scale TES containers, and an air-cooled heat extraction coil to replace the Stirling engine heat exchanger. Charging and discharging, constant temperature operation, mixed mode operation, thermal inertial, etc. were studied. The heat pipe performance was verified, as were the thermal energy storage and discharge rates and isothermal discharges.

Narayanan, R.↗

STS-69 Postflight Presentation

A postflight conference of the STS-69 mission is presented. The flightcrew ('The Dog Team') consisted of Cmdr. David Walker, Pilot Kenneth Cockrell, Payload Cmdr. James Voss, and Mission Specialists James Newman and Michael Gernhardt. The mission's primary objective was the deployment and retrieval of the SPARTAN-201 satellite, which investigated the interaction between the Sun and it's solar wind. Other secondary experiments and shuttle payloads included the Wake Shield Facility (WSF), which grew several layers of semiconductor films, the International Extreme Ultraviolet Hitchhiker (IEH-1), the Capillary Pumped Loop-2/Gas Bridge Assembly (CAPL-2/GBA), several Get Away Specials (GAS) experiments, the Electrolysis Performance Improvement Concept Study (EPICS), the Thermal Energy Storage (TES-2) experiment, the Commercial Generic Bioprocessing Apparatus-7 (CGBA-7), the National Institutes of Health-Cells 4 (NIH-C4) experiment, and the Biological Research in Canister-6 (BRIC-6) experiment. Earth views consisted of Saudi Arabia water wells, uncommon vortices over Oman, the Amazon River, the Bahamas, Somalia, a sunset over the Earth's horizon, and two hurricanes, Luis and Marilyn.

Source record↗

Thermal evaluation of advanced solar dynamic heat receiver performance

The thermal performance of a variety of concepts for thermal energy storage as applied to solar dynamic applications is discussed. It is recognized that designs providing large thermal gradients or large temperature swings during orbit are susceptible to early mechanical failure. Concepts incorporating heat pipe technology may encounter operational limitations over sufficiently large ranges. By reviewing the thermal performance of basic designs, the relative merits of the basic concepts are compared. In addition the effect of thermal enhancement and metal utilization as applied to each design provides a partial characterization of the performance improvements to be achieved by developing these technologies.

Crane, Roger A.↗

NASA's Office of Aeronautics and Exploration Technology space power flight projects

NASA created a program called In-STEP (in-space technology experiments program) to give the aerospace community an opportunity to validate advanced technologies in space. In-STEP has funded feasibility studies for the following experiments in the power technology arena: a microsphere insulation investigation, a utilized regenerative fuel cell experiment, an inflatable solar collector experiment, a moving belt radiator experiment, and a liquid drop radiator experiment. The following experiments are currently in the experiment definition phase: an integrated two-phase thermal experiment, an electrolysis performance experiment, and a sodium sulfur battery experiment. Three In-STEP experiments are entering the hardware fabrication phase: thermal energy storage technology, solar array module plasma interaction, and heat pipe performance experiments. Each of these experiments is described, with an emphasis on the benefits of technology validation.

Chmielewski, Art B.↗

Temperature-Staged Thermal Energy Storage Enabling Low Thermal Exergy Loss Reflux Boiling in Full Spectrum Solar Systems

Hybrid full spectrum solar systems (FSSS) designed to capture and convert the full solar wavelength spectrum use hybrid solar photovoltaic/thermodynamic cycles that require low thermal exergy loss systems capable of transferring high thermal energy rates and fluxes with very low temperature differentials and losses. One approach to achieving this capability are high-heat-flux reflux boiling systems that take advantage of high heat transfer boiling and condensation mechanisms. Advanced solar systems are also intermittent by their nature and their electrical generation is often out-of-phase with electric utility power demand, and their required power system cycling reduces efficiency, performance (dispatch ability), lifetime, and reliability. High temperature thermal energy storage (TES) at 300-600°C enables these reflux boiling systems to simultaneously store thermal energy internally to increase the energy dispatch ability of the associated solar system, as this can increase the power generation profile by several hours (up to 6-10 hours) per day. Many TES phase change materials (PCM’s) exist including KNO3, NaNO3, LiBr/KBr, MgCl2/NaCl/KCl, Zn/Mg, and CuCl/NaCl, which have various operating melting points and different latent heats of fusion. Common, cost effective TES PCM's are FeCl2/NaCl/KCl mixtures, whose phase change temperature can be varied and controlled by simple composition adjustments. This paper presents and discusses unique "temperature-staged" thermal energy storage configurations using these TES materials and analysis of such systems integrated into high-heat-flux reflux boiling systems. In this specific application, the TES materials are designed to operate at staged temperatures surrounding an operating design point near 350°C, while providing 18 kW of source heat transfer to operate a thermoacoustic power system during off-sun conditions (e.g., temporary cloud conditions, after sun-down). This work discusses relevant configurations, and critical thermal and entropy models of the TES configurations, which show the inherent minimization of thermal exergy during critical heat transfers within the configurations and systems envisioned.

Hendricks, Terry J.↗

Full-size solar dynamic heat receiver thermal-vacuum tests

The testing of a full-size, 120 kW, solar dynamic heat receiver utilizing high-temperature thermal energy storage is described. The purpose of the test program was to quantify receiver thermodynamic performance, operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber with liquid nitrogen cold shrouds and an aperture cold plate to partly simulate a low-Earth-orbit environment. The cavity of the receiver was heated by an infrared quartz lamp heater with 30 independently controllable zones to allow axially and circumferentially varied flux distributions. A closed-Brayton cycle engine simulator conditioned a helium-xenon gas mixture to specific interface conditions to simulate the various operational modes of the solar dynamic power module on the Space Station Freedom. Inlet gas temperature, pressure, and flow rate were independently varied. A total of 58 simulated orbital cycles, each 94 minutes in duration, was completed during the test conduct period.

Sedgwick, L. M.↗

Full-size solar dynamic heat receiver thermal-vacuum tests

The testing of a full-size, 102 kW, solar dynamic heat receiver utilizing high-temperature thermal energy storage is described. The purpose of the test program was to quantify receiver thermodynamic performance, operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber with liquid nitrogen cold shrouds and an aperture cold plate to partly simulate a low-Earth-orbit environment. The cavity of the receiver was heated by an infrared quartz lamp heater with 30 independently controllable zones to allow axially and circumferentially varied flux distributions. A closed-Brayton cycle engine simulator conditioned a helium-xenon gas mixture to specific interface conditions to simulate the various operational modes of the solar dynamic power module on the Space Station Freedom. Inlet gas temperature, pressure, and flow rate were independently varied. A total of 58 simulated orbital cycles, each 94 minutes in duration, was completed during the test period.

Sedgwick, L. M.↗

Heat pipe solar receiver with thermal energy storage

An HPSR Stirling engine generator system featuring latent heat thermal energy storge, excellent thermal stability and self regulating, effective thermal transport at low system delta T is described. The system was supported by component technology testing of heat pipes and of thermal storage and energy transport models which define the expected performance of the system. Preliminary and detailed design efforts were completed and manufacturing of HPSR components has begun.

Zimmerman, W. F.↗

Understanding Thermal Transport in Polymer –Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems.Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.

Thermal transport↗

Understanding Thermal Transport in Polymer - Silver Nanowire Composites

Understanding thermal transport across filler-polymer interfaces and filler-filler contacts within polymer composites is of great importance for better thermal design of the composites that are widely used in high-performance heat exchangers, energy storage devices, and flexible electronics. Over the past several decades, considerable progress has been made in improving the thermal conductivity of polymer composites, but several key questions concerning the influence of interfacial thermal resistance, or Kapitza resistance, still remain. Firstly, the thermal properties of these composites are highly dependent on thermal transport through the filler network and its contacts. For metallic nanofillers, the thermal conductivity is often estimated using the Wiedemann-Franz law based on electrical conductivity; however, it remains a question whether the Wiedemann-Franz law still holds at nanoscale contacts. Through investigation of silver nanowires of varying sizes, we were able to demonstrate that the Lorenz number for silver nanowire increases with decreasing nanowire diameter. Examination of the corresponding electrical and thermal conductivities indicate that these changes are due to that the relative contribution of phonons becomes more significant as a result of elastic stiffening. Furthermore, we show that for silver nanowires, the contact thermal resistance is ~8 times lower than that of multi-walled carbon nanotube (MWCNT) of similar diameters. Additionally, through systematic studies of electrospun polymer-silver nanowire composite nanofibers, we investigated the impact of interface morphology on the thermal conductivity enhancement of the composite system and probed the value of the Kapitza resistance for individual polymer-filler interfaces. For polymer nanofibers containing continuous, single silver nanowires, the thermal conductivity increases linearly with increasing volume fraction of silver, which is consistent with the prediction of percolation theory for samples above the percolation limit. By comparing this linear trend to the measured thermal conductivities of composite nanofibers with more complex structures, we were able to determine the resistance associated with any additional polymer-filler boundaries. In doing so we find that the thermal boundary resistance for polyvinylpyrrolidone (PVP)–silver interfaces is significantly lower than that of comparable polymer-MWCNT composite systems. Together our studies provide new insights into thermal transport in polymer nanocomposites and should help facilitate the design of high performance polymeric thermal interface material.

Matthew L. Fitzgerald↗

Phase 1 of the First Small Power System Experiment (engineering Experiment No. 1). Volume 5: Supporting Analyses and Trade Studies

The development and design of a modular solar thermal power system for application in the 1 to 10 MWe range is described. The system is used in remote utility applications, small communities, rural areas, and for industrial uses. Thermal and stress analyses are performed on the collector subsystem, energy storage subsystem, energy transport subsystem, the power conversion subsystem, and the plant control subsystem.

Holl, R. J.↗

Preliminary Investigation on Battery Sizing Investigation for Thrust Vector Control on Ares I and Ares V Launch Vehicles

An investigation into the merits of battery powered Electro Hydrostatic Actuation (EHA) for Thrust Vector Control (TVC) of the Ares I and Ares V launch vehicles is described. A top level trade study was conducted to ascertain the technical merits of lithium-ion (Li-ion) and thermal battery performance to determine the preferred choice of an energy storage system chemistry that provides high power discharge capability for a relatively short duration.

Miller, Thomas B.↗

Evaluation of solar thermal power plants using economic and performance simulations

An energy cost analysis is presented for central receiver power plants with thermal storage and point focusing power plants with electrical storage. The present approach is based on optimizing the size of the plant to give the minimum energy cost (in mills/kWe hr) of an annual plant energy production. The optimization is done by considering the trade-off between the collector field size and the storage capacity for a given engine size. The energy cost is determined by the plant cost and performance. The performance is estimated by simulating the behavior of the plant under typical weather conditions. Plant capital and operational costs are estimated based on the size and performance of different components. This methodology is translated into computer programs for automatic and consistent evaluation.

El-Gabawali, N.↗