Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

DC Microgrid Reliability Enhancement with Adaptive Converter Thermal Management

Due to the different device selections, aging levels, and thermal dissipation performance, some converters may take additional thermal stress on switching devices than others in paralleled converter systems, which will reduce system reliability. To address this problem, this paper proposes a power-sharing strategy with adaptive thermal management. First, the temperature-based power loss model and electrical-thermal model are established. Based on that, a high-accuracy IGBT junction temperature estimate considering the power loss-temperature coupling can be achieved. Further, the thermal-sharing for all the switching devices in paralleled converters can be achieved with the proposed adaptive thermal management strategy. The proposed strategy can change the power-sharing ratio adaptively according to the system operation conditions, which will contribute to the system reliability enhancement. The effectiveness of the proposed strategy is verified through PLECS thermal simulation and joint real-time simulation with Dspace and RT-box.

DC microgrid↗

Thermal management of a high temperature sodium sulphur battery stack

The sodium sulfur battery is an advanced secondary battery with high potential for grid-level storage due to their high energy density, low cost of the reactants, and high open-circuit voltage. However, as the operating temperature of the battery is high (about 300 °C), effective thermal management is required to prevent thermal runaway under high current density operation. Here, to develop efficient thermal management strategies, a detailed, thermo-electrochemical, non-isothermal, distributed dynamic model of a sodium-sulfur battery stack is developed. Models of three thermal management strategies are developed and analyzed in this work: active cooling, passive cooling, and hybrid cooling. The active cooling strategy uses air as the cooling medium whereas, the passive cooling strategy uses a phase change material. In the hybrid cooling strategy, both active and passive cooling strategies are used. Due to the high operating temperature of the sodium sulfur batteries, the rejected heat can be utilized effectively and consequently a high variability in the heat rejection rate may not be acceptable. Performance of these strategies is analyzed under high current density operation by evaluating the variability in the cell temperature during charge/discharge cycles, temperature difference between the cells based on their locations, and variability in the heat rejection rate. The phase change-based hybrid thermal management strategy with an embedded controller maintained the temperature variation within ±/- 2.8 °C. Considering the tradeoff between the capital cost for PCM, fan power requirement, and variability in the heat rejection rate, the optimal quantity of the PCM and the maximum air velocity for the maximum current density of 260 mA/cm 2 (0.55 C-rate) were found be 0.74 g/Wh and 3 m/s, respectively.

25 ENERGY STORAGE↗

Integrated Traction Drive Thermal Management: Keystone Project 3

The presentation represents a report of accomplishments during FY 2024 and is prepared for 2024 DOE VTO Annual Merit Review. The project goal is identifying pathways enabling high-performance, compact, and reliable integrated electric drives and facilitation of achieving DOE 2025 target of 33 kW/L system power density for an electric traction drive through support of other EDT consortium members in design and development of thermal management systems for their respective integrated drive concepts. Specific objectives are: 1) research and evaluation of motor-integrated power electronics packaging technologies and thermal management approaches; 2) explore novel materials and manufacturing options (3D printing with thermally enhanced polymers or ceramic materials) for key thermal management system components; 3) develop thermal management system and its sub-components to enable integrated electric drive DOE power density targets in collaboration with project partners; 4) support activities of DOE's Electric Drive Technologies (EDT) consortium members, Oak Ridge National Laboratory (ORNL), University of Wisconsin and Georgia Tech research teams in thermal management component design and thermal modeling of their integrated traction drives.

ADVANCED PROPULSION SYSTEMS↗

A Comprehensive Numerical and Experimental Study for the Passive Thermal Management in Battery Modules and Packs

Cooling plates in battery packs of electric vehicles play critical roles in passive thermal management systems to reduce risks of catastrophic thermal runaway. In this work, a series of numerical simulations and experiments are carried out to unveil the role of cooling plates (both between cells and a bottom plate parallel to the cell stack) on the thermal behavior of battery modules and packs under nail penetrations. First, we investigated the role of side cooling plates on the thermal runaway propagation mitigation in battery modules (1S3P) and packs (3S3P) by varying the key parameters of the side cooling plates, such as plate thicknesses, thermal contact resistances, and materials. Then, three important factors for passive thermal management systems are identified: (i) thermal mass of side cooling plates, (ii) interfacial thermal contact resistances, and (iii) the effective heat transfer coefficients at exterior surfaces. The roles of bottom cooling plates on thermal runaway propagation mitigation in 1S3P and 1S5P battery modules are numerically investigated by comparing the thermal behavior of the modules with only side cooling plates and with both side and bottom cooling plates.

25 ENERGY STORAGE↗

Impact of Fuel Properties on the Combustion of Late Post Injections used for Aftertreatment Thermal Management

Typical calibration for catalyst thermal management for compression-ignition engines involves delaying the post-injection into the expansion stroke. Reduced work extraction due to the late heat release event is used to increase the exhaust gas temperature to shorten the time associated with reaching optimal temperatures for aftertreatment systems. Shorter catalyst heat-up time can simultaneously reduce tail-pipe emissions and the typical fuel penalties associated with this mode of operation. In this study, the effects of volatility, reactivity, and oxygen content of the fuel on combustion stability and emissions were studied in a light-duty single-cylinder research engine. Blends of iso-octane/ n-heptane and farnesane/ 2,2,4,4,6,8,8-heptamethylnonane were used to study the impacts of volatility and reactivity. At constant reactivity, little to no variation in combustion performance was observed due to differences in volatility. On the other hand, increased reactivity improved combustion stability and efficiency at late injection timings (+24 CAD). The combined effect of increase in chemical reactivity and oxygen content was analysed by comparing the baseline #2 diesel operation with two blends of mono-ethers and #2 diesel to achieve cetane numbers (CNs) of 45 and 55, and a pure blend of mono-ether components with CN > 100. Fuels with higher reactivity and oxygen content were found to reduce engine-out hydrocarbon and carbon mono-oxide emissions while also achieving stable combustion at post-injection timings later than those achievable with diesel fuel. The pure ether-blend had the latest achievable post-injection timing (≥+26 CAD) while still maintaining stable combustion. At similar combustion stability, the pure ether blend was found to have 2.8% higher combustion efficiency and 4.3% higher thermal efficiency than the baseline diesel. The ether-diesel blends at CN45 and CN55 were found to have 1.8% higher combustion efficiency than baseline diesel. The results demonstrate that fuels with increased reactivity can increase combustion efficiency, reducing carbon monoxide and hydrocarbon emissions, while maintaining similar exhaust temperature and combustion stability compared to baseline diesel. Further greenhouse gas benefits can also be realized as the mono-ether bioblendstocks show potential for >50% reduction in greenhouse gas emissions relative to diesel fuel based on their production method.

99 GENERAL AND MISCELLANEOUS↗

Integrated Traction Drive Thermal Management: Keystone Project 3

The presentation represents a report of accomplishments during FY 2022 and is prepared for 2022 DOE VTO Annual Merit Review. The project goal is facilitation of achieving DOE 2025 target of 33 kW/L system power density for an electric traction drive through support of other EDT consortium members in design and development of thermal management systems for their respective integrated drive concepts. Namely, identifying pathways enabling high-performance, compact, and reliable integrated electric drives. Specific objectives are: 1) Research and evaluation of motor-integrated power electronics packaging technologies and thermal management approaches. 2) Development of thermal management system and its sub-components to enable integrated electric drive DOE power density targets in collaboration with project partners. 3) Supporting activities of DOE's Electric Drive Technologies (EDT) consortium members, Oak Ridge National Laboratory (ORNL) and University of Wisconsin research teams in thermal management component design and thermal modeling of their integrated traction drives. 4) Identifying candidate driveline fluids suitable for direct cooling of traction-drive components and high-voltage power electronics and evaluate their convective cooling performance.

ADVANCED PROPULSION SYSTEMS↗

Comparative analysis of thermal management systems in electric vehicles at extreme weather conditions: Case study on Nissan Leaf 2019 Plus, Chevrolet Bolt 2020 and Tesla Model 3 2020

With the surge in electric vehicle (EV) adoption and the need for extended driving ranges, optimizing energy efficiency, particularly through thermal management, is critical, especially in extreme weather. Managing the substantial energy needed for cabin climate control and battery temperature regulation can increase energy demands by over 50 %, severely limiting range. This study conducts a comparative analysis of thermal management systems (TMS) in three popular EV vehicles, 2020 Chevrolet Bolt, 2019 Nissan Leaf Plus, and 2020 Tesla Model 3, evaluating their distinct TMS configurations and performance under varied weather conditions. Using both numerical simulations and experimental data collected on a controlled test bench at Argonne National Laboratory, we assess how TMS architecture and operational modes influence energy consumption and range. A comprehensive TMS model was developed, integrating cabin and battery thermal sub-models in the Autonomie software platform, to simulate temperature fluctuations and range impacts. Cabin climate was modeled using a mono-zonal approach, while battery cell temperature distribution was estimated through a 2D nodal structure. Each vehicle's distinct TMS setup was evaluated: the Chevrolet Bolt and Tesla Model 3 use a dual evaporator vapor compression cycle with a PTC heater for the cabin and a coolant loop for battery thermal management; the Nissan Leaf Plus employs a heat pump with a PTC heater for the cabin and air-cooling for the battery. Tests conducted at ambient temperatures of 35°C, 22°C, -7°C, and -18°C reveal significant differences in energy use and range reduction across both configurations and conditions. At 35°C, the Tesla Model 3, Chevrolet Bolt, and Nissan Leaf Plus have a range reduction of 8%, 9%, and 13%, respectively, due to air conditioning. In winter, heating technology is paramount; at -7°C, the Nissan Leaf's heat pump configuration achieves a lower range reduction (19.3%) compared to the Tesla and Chevrolet Bolt PTC heaters, which reduce range by 28.3% and 31%, respectively. Further, this study provides valuable insights for automotive engineers, EV technology researchers, and thermal management system designers aiming to enhance electric vehicle performance by understanding how different weather conditions and TMS architectures impact energy consumption and driving range.

33 ADVANCED PROPULSION SYSTEMS↗

Thermoelectric air conditioning undergarment for personal thermal management and HVAC energy saving

Personal thermal management systems (PTMS) are highly desirable for improving individual thermal comfort and reducing indoor HVAC energy consumption. Although there have been many attempts in developing PTMS, existing PTMS are generally bulky, heavy or immobile. Besides, previous analysis on additional personal cooling and heating power required for maintaining thermal comfort in changing environments did not consider the individual difference in metabolism and the variability of comfort skin temperature with environmental conditions. In this paper, we report on the development of a novel lightweight (<1 kg) thermoelectric air conditioning undergarment system with a preferred design of branching tubing network (branching angle of 60° and diameter ratio of 0.782) for air distribution. Through thermal manikin and human subject tests, we demonstrated that the novel system is capable of providing a maximum of 15.5 W of personal cooling and 18.1 W personal heating with a coefficient of performance (COP) greater than 0.4, which is sufficient to the expansion of the indoor set-points by at least 2.2 °C (4 °F) on both sides without compromising thermal comfort and the potential saving of about 15% HVAC energy. Furthermore, our study improved the understanding of the required additional personal cooling and heating power for changing environmental conditions, which are essential guidelines for the further development of PTMS.

42 ENGINEERING↗

Integrated Traction Drive Thermal Management: Keystone Project 3

Current poster provides update on research progress on Integrated Traction Drive Thermal Management project for Department of Energy's 2021 Annual Merit Review. NREL's support in thermal management system design for integrated traction drives of two Electric Drive Technologies Consortium teams (led by Oak Ridge National Lab and University of Wisconsin) is highlighted.

ADVANCED PROPULSION SYSTEMS↗

Integrated Traction Drive Thermal Management: Keystone Project 3

The presentation was developed for the U.S. Department of Energy (DOE) Vehicle Technologies Program 2020 Annual Merit Review and Peer Evaluation Meeting. It reports on progress and accomplishments of DOE funded Integrated Traction Drive Thermal Management project. Highlighted are NREL's research accomplishments during FY 2020. Challenges associated with thermal management of integrated traction drives for electric vehicles arise due to the limited packaging space, coolant distribution, electrical connections, and ambient temperatures. For this project at NREL, research focuses on enabling thermal management technologies to support a modular, compact, self-contained integrated electric drive unit with motor and power electronics. Integration approaches, based on packaging location and coolant options for power electronics integrated with candidate motor technologies to reduce cables and connectors, are reviewed and compared using finite element analysis (FEA) tools. Automatic transmission fluid (ATF) jet impingement cooling characterization is carried out experimentally (measuring heat transfer coefficients) and using computational fluid dynamics (CFD) modeling.

47 OTHER INSTRUMENTATION↗

An open source fast fluid dynamics model for data center thermal management

Although computational fluid dynamics (CFD) has been widely adopted to improve data center thermal management, the high computational demand limits its applications, such as multivariate optimal design and operation. Fast fluid dynamics (FFD), which has been applied for fast airflow simulation, shows great potential. However, few research applied FFD for optimal design and operation of data center thermal management. This research improves the FFD model for data centers and conducts a comprehensive evaluation and demonstration. First, the FFD model is improved by solving the advection and diffusion equations together using an upwind scheme instead of a semi-Lagrangian advection solver in the conventional FFD model. Second, new features for data centers are added, such as a pressure correction method to simulate plenum airflow and dynamic boundary conditions for IT racks. The new FFD model is first validated with two indoor environment cases and the results show that the new FFD model has slightly better overall prediction accuracy and faster speed compared to the conventional FFD model. It is also observed that both FFD models achieve acceptable accuracy, except for a few localized disparities with experimental data, which might be due to simplified handling of turbulence viscosity near the boundaries. Furthermore, validation with a real data center shows that the FFD model achieves a similar level of accuracy as CFD when compared to the experimental measurements with some level of uncertainties. It is then demonstrated for data center optimal design and operation, which saves 53.4–58.8% of annual energy while still meeting the thermal requirements. In conclusion, with a much faster speed and comparable accuracy compared to CFD, the FFD model parallelized on a graphics processing unit is promising for practical model-based data center early design and operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hierarchical multi-time-scale predictive thermal management and fuel optimization for heavy-duty compression ignition engines

For heavy-duty diesel engines, NO X emissions reduction is strongly constrained by fuel efficiency. This paper presents a hierarchical model predictive controller (H-MPC) for coordinated control of tailpipe NO X emissions and fuel consumption. The H-MPC uses the separation of slow and fast dynamics that exist in the engine and its aftertreatment system. The controller is synthesized with an architecture in which a high-level MPC uses a longer prediction horizon compared to the low-level predictive controller which tracks the high-level controller command and manages the thermal dynamics of the aftertreatment system. Engine load preview enables the high-level controller to estimate the desired catalyst temperature ahead of time and addresses the selective catalytic reduction (SCR) slow thermal dynamics. Calculated by the high-level controller, the intake manifold pressure, and the start of injection (SOI) crank angle is used as reference trajectories in the low-level controller that regulates fast dynamical behaviors such as engine out NO X emissions. Hardware-in-the-loop (HIL) validation of this integrated H-MPC on a rapid prototype controller shows that when the SCR catalyst temperature is above light-off temperature (warmed-up condition), the engine operation is shifted to operate with the best fuel economy since the warmed-up SCR can efficiently reduce the engine-out NO X emissions. Results indicate that up to 0.8% benefit in cycle averaged BSFC along with a 13% reduction in tailpipe NO X compared to a stock engine calibration can be achieved with the coordinated engine and aftertreatment system through H-MPC.

Engineering↗

2025 InterPACK: Thermal Management and Reliability Aspects

The presentation will provide an overview of automotive power electronics and electric machines thermal management systems that are typical for light-duty vehicles. Unique thermal and environmental aspects related to medium and heavy-duty vehicle applications will then be discussed. Finally, advanced thermal management and packaging technologies that could be evaluated and used in this project will be described.

33 ADVANCED PROPULSION SYSTEMS↗

Automotive Power Electronics and Electric Machine Thermal Management

The transition to modular and scalable electrified vehicle transportation requires technologies to improve power density within cost and reliability constraints to maximize vehicle platform flexibility. Key research challenges arise due to the limited packaging space, coolant distribution, electrical connections, and ambient temperatures. Challenges include thermal management for compact power-dense electric machines and the associated power electronics for power management within the vehicle. High-temperature silicon and wide-bandgap (WBG) based power electronics systems are of interest to enable compact and efficient electric drive systems. The higher temperatures present packaging challenges for thermal management and reliability. In this work, we provide an overview of research for thermal characteristics of materials, packages and thermal management approaches for enabling compact power dense automotive electric drive systems.

DIRECT ENERGY CONVERSION↗

Revolutionizing thermal Management in Next-Generation AI data centers: Challenges and breakthrough innovations

Data centers (DCs) serve as critical infrastructure for powering the growth and evolution of AI. Next-generation AI DCs present unique challenges in thermal management driven by unprecedented computational demands. This paper provides a comprehensive summary of key stakeholder perspectives on technology gaps, infrastructure requirements, test bed needs, emerging opportunities, and preliminary solutions related to thermal management for AI DCs. It establishes six strategic pillars of thermal management for next generation AI DC: reliability, deployability, efficiency, resilience, measurability, and valorization. The discussion spans a range of critical topics, including advanced cooling technologies, thermal strategies for emerging modular and edge DCs, system-level optimization and control frameworks, infrastructure planning and grid integration designs, benchmarking approaches, and pathways for waste heat recovery and reuse. The proposed research, development, and demonstration efforts are aimed at accelerating the deployment of AI DCs while ensuring energy efficiency, reliability, safety, and regulatory compliance.

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Thermal Management Solution for an Integrated Outer-Rotor Motor Drive: Opportunities and Challenges

This work highlights an integrated thermal management solution for the outer-rotor motor (ORM) drive. The integrated ORM drive utilizes water-ethylene glycol coolant for power electronics and stator cooling. Air cooling is used for rotor laminations, magnets and outer-rotor structures, and the rotor shaft. To fully understand the performance of the integrated ORM drive and thermal management coupling effects, a full drive conjugate heat transfer model has been developed to investigate coupled cooling performance of various components of the ORM drive. Various motor rotational speeds, power output scenarios, and cooling options for the integrated ORM drive have been investigated. The model estimates the operating window for the ORM drive while keeping component operating temperatures below prescribed limits. The model also highlights the importance of windage losses at higher rotational speeds for this ORM design, which involves higher rotor surface area per unit width of the rotor. Different designs are also investigated, particularly focusing on rotor cooling with air either naturally induced by rotor spin or forced airflow with the help of a blower, to circumvent challenges imposed by higher windage losses. The work highlights motor rotational speed limitations and the need for potential liquid cooling options for desired rotor performance at higher rotational speeds. Liquid cooling for the rotor may even become more critical for nonuniform rotor-stator gaps, leading to even higher and uneven windage losses across the full circumference of the motor, consequentially, more heating for the rotor.

30 DIRECT ENERGY CONVERSION↗

Passive radiative thermal management using phase-change metasurfaces

Abstract Realizing innovative composite materials with passive thermal management capabilities and minimal ecological footprints is a challenging but much sought-after goal that would have a transformative effect on renewable energy sciences. We demonstrate an environmentally friendly metasurface utilizing vanadium dioxide (VO 2 ) that offers responsiveness to ambient temperature and potentially long-term stability. The metasurface enables passive thermal management by self-adjusting its absorptivity and emissivity response over a broad bandwidth ranging from visible to mid-infrared (IR) wavelengths. Above the VO 2 phase transition the metasurface exhibits increased mid-IR emissivity and reduced visible/near-IR absorptivity, creating an efficient radiative emission channel in the first atmospheric transparency window with reduced absorption of solar radiation. In contrast, below VO 2 ’s transition temperature, the metasurface increasingly absorbs sun light while minimizing mid-IR radiative heat losses. Moreover, a functional silicon layer eliminates the need for an additional capping layer commonly employed to protect VO 2 from environmental degradation. The additional protective layer often impedes the use and performance of VO 2 based devices in terrestrial as well as spacecraft applications. Therefore, the proposed durable and eco-friendly metasurface will be an excellent candidate for essential passive thermal regulation systems across residential and terrestrial applications.

42 ENGINEERING↗

Thermally Anisotropic Composites for Heat Redirection and Thermal Management in Building Envelopes

In building envelope systems, thermal management is important from energy conservation and thermal comfort perspectives, and is typically done via insulation, thermal mass, solar control and shading, etc. Thermal anisotropy is commonly utilized in electronics for heat dissipation. This article investigates the feasibility of utilizing thermally anisotropic composites (TACs) to reduce unwanted heat gains and losses through the building envelope by redirecting the heat transfer to or from appropriate heat sinks and sources.Numerical simulations of building envelope components using COMSOL Multiphysics and whole building simulations using EnergyPlus (E+) were performed to estimate the energy savings potential of TACs used in external walls of residential buildings. Application of TACs was compared with baseline walls with cavity insulation as well as with and without exterior continuous insulation (CI). The COMSOL simulations indicated 75% or higher reductions in heat gains when using a TAC coupled with a heat sink compared to an exterior CI case. In terms of energy savings in a hot climate, E+ models estimated cooling energy savings of 19% with a "TAC + heat sink" compared to a baseline wall with only cavity insulation. Further, a small-scale test sample with a TAC-heat sink system was built and tested in a multi-transducer heat flow meter (HFM). The heat sink was a copper tube circulating cold water. The experiments verified the re-direction of heat to a sink and significant reduction in heat transfer through the test specimen. The experiments showed that the heat redirection only occurred in the presence of both thermal anisotropy and water circulation; if either element was missing, the system behaved like a traditional envelope component.

Biswas, Kaushik↗