Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Power Output”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Preliminary Analysis: Am-241 RHU/TEG Electric Power Source for Nanosatellites

The Februay 2013 Space Works Commercial report indicates a strong increase in nano/microsatellite (1-50 kg) launch demand globally in future years. Nanosatellites (NanoSats) are small spacecraft in the 1-10 kg range, which present a simple, low-cost option for developing quickly-deployable satellites. CubeSats, a special category of NanoSats, are even being considered for interplanetary missions. However, the small dimensions of CubeSats and the limited mass of the NanoSat class in general place limits of capability on their electrical power systems (especially where typical power sources such as solar panels are considered) and stored energy reserves; restricting the power budget and overall functionality. For example, leveraging NanoSat clusters for computationally intensive problems that are solved collectively becomes more challenging with power related restrictions on communication and data-processing. Further, interplanetary missions that would take NanoSats far from the sun, make the use of solar panels less effective as a power source as their required area would become quite large. To overcome these limitations, americium 241 (Am-241) has been suggested as a low power source option. The Idaho National Laboratory, Center for Space Nuclear Research reports that:  (Production) requires small quantities of isotope - 62.5 g of Pu-238; 250 g Am- 241 (for 5 We); Am-241 is available at around 1 kg/yr commercially; Am-241 produces 59 kev gammas which are stopped readily by tungsten so the radiation field is very low. Whereby, an Am-241 source could be placed in among the instruments and the waste heat used to heat the platform; and  amounts of isotope are so low that launch approval may be easier, especially with tungsten encapsulation. As further reported, Am-241 has a half-life that is approximately five times greater than that of Pu- 238 and it has been determined that the neutron yield of a 241-AmO(sub 2) source is approximately an order of magnitude lower than that of a 238-PuO(sub 2) source of equal mass and degree of (sup 16)O enrichment. Also it has been demonstrated that shielded heat sources fuelled by oxygen-enriched 238-PuO(sub 2) have masses that are up to 10 times greater than those fuelled by oxygenenriched 241-AmO(sub 2) with equivalent thermal power outputs and neutron dose rates at 1 m radii. For these reasons, Am-241 is well suited to missions that demand long duration electrical power output, such as deep spaceflight missions and similar missions that use radiation-hard electronics and instrumentation that are less susceptible to neutron radiation damage.

Robertson, Glen A.↗

Affordable Development and Demonstration of a Small NTR Engine and Stage: A Preliminary NASA, DOE, and Industry Assessment

The Nuclear Thermal Rocket (NTR) represents the next evolutionary step in cryogenic liquid rocket engines. Deriving its energy from fission of uranium-235 atoms contained within fuel elements that comprise the engine's reactor core, the NTR can generate high thrust at a specific impulse of approx. 900 seconds or more - twice that of today's best chemical rockets. In FY'11, as part of the AISP project, NASA proposed a Nuclear Thermal Propulsion (NTP) effort that envisioned two key activities - "Foundational Technology Development" followed by system-level "Technology Demonstrations". Five near-term NTP activities identified for Foundational Technology Development became the basis for the NCPS project started in FY'12 and funded by NASA's AES program. During Phase 1 (FY'12-14), the NCPS project was focused on (1) Recapturing fuel processing techniques and fabricating partial length "heritage" fuel elements for the two candidate fuel forms identified by NASA and the DOE - NERVA graphite "composite" and the uranium dioxide (UO2) in tungsten "cermet". The Phase 1 effort also included: (2) Engine Conceptual Design; (3) Mission Analysis and Requirements Definition; (4) Identification of Affordable Options for Ground Testing; and (5) Formulation of an Affordable and Sustainable NTP Development Strategy. During FY'14, a preliminary plan for DDT&E was outlined by GRC, the DOE and industry for NASA HQ that involved significant system-level demonstration projects that included GTD tests at the NNSS, followed by a FTD mission. To reduce development costs, the GTD and FTD tests use a small, low thrust (approx. 7.5 or 16.5 klbf) engine. Both engines use graphite composite fuel and a "common" fuel element design that is scalable to higher thrust (approx. 25 klbf) engines by increasing the number of elements in a larger diameter core that can produce greater thermal power output. To keep the FTD mission cost down, a simple "1-burn" lunar flyby mission was considered along with maximizing the use of existing and flight proven liquid rocket and stage hardware (e.g., from the RL10-B2 engine and Delta Cryogenic Second Stage) to further ensure affordability. This paper provides a preliminary NASA, DOE and industry assessment of what is required - the key DDT&E activities, development options, and the associated schedule - to affordably build, ground test and fly a small NTR engine and stage within a 10-year timeframe.

Nuclear rocket engines↗

Simulation of an Electromechanical Spin Motor System of a Control Moment Gyroscope

A two-phase brushless DC motor (BDCM) with pulse-width modulated (PWM) voltage drive is simulated to control the flywheel speed of a control moment gyroscope (CMG). An overview of a double-gimballed control moment gyroscope (DGCMG) assembly is presented along with the CMG torque effects on the spacecraft. The operating principles of a two-phase brushless DC motor are presented and the system's electro-mechanical equations of motion are developed for the root-mean-square (RMS) currents and wheel speed. It is shown that the system is an extremely "stiff" set of first-order equations for which an implicit Euler integrator is required for a stable solution. An adaptive proportional voltage controller is presented which adjusts the PWM voltages depending on several control modes for speed, current, and torque. The simulation results illustrate the interaction between the electrical system and the load dynamics and how these influence the overall performance of the system. As will be shown, the CMG spin motor model can directly provide electrical power use and thermal power output to spacecraft subsystems for effective (average) calculations of CMG power consumption.

Inampudi, Ravi↗

Effect of Delayed Energy Release on Power Normalization in Reactor Depletion Calculations

Reactor depletion calculations typically assume that the thermal power of the reactor is directly proportional to the instantaneous fission rate within the core. However, approximately 7% of the sensible energy released per fission comes from the radioactive decay of fission products, which occurs alter the fission event. Thus, the assumed direct relationship between reactor power and fission rate implies that all fission products have reached secular equilibrium within the core. In situations where fission product concentrations have not reached equilibrium (e.g., shortly after reactor startup or a change in reactor power during operation), the delayed energy release due to fission product decay creates a nonlinear relationship between reactor power and fission rate. This non-linear relationship, in turn, affects the neutron flux levels and fuel consumption rate required to maintain the desired thermal power output for the reactor. For example, during initial startup of a commercial light water reactor the apparent energy release per fission is ∼7{sup %} lower than the typical value of ∼200 MeV/fission due to the potential energy stored in radioactive fission products. As a consequence, the flux level (and, therefore, uranium consumption rate) in the reactor must be correspondingly higher to preserve the desired reactor power. As the reactor operates and fission product inventories increase, the decay heat produced by the reactor will rise, producing a corresponding increase in the apparent energy release per fission. The characteristic time-dependent behavior of energy release due to the decay of fission products (i.e., decay heat) following reactor startup, shutdown, or changes in reactor power is well-known and widely-used in reactor safety analyses. However, to our knowledge, the effects of time-dependent decay heating rates on reactor depletion calculations have not been thoroughly investigated. In this paper, we present a simple methodology for explicitly accounting for delayed energy release due to the decay of fission products in reactor depletion calculations. In the proposed method, the balance equations for fission product decay energy are incorporated into the depletion coefficient matrix, using a strategy similar to that described by Isotalo in 2016. The modified system of differential equations can be solved via a matrix exponential approximation (or other suitable numerical method) to yield solutions for both nuclide densities and decay energy emission densities as a function of time. Numerical results from the method are presented for simplified (one-group point (0-D) and 1-D) representations of a commercial pressurized water reactor (PWR), in order to estimate the effect of delayed energy release on fuel consumption and flux level immediately following reactor startup.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design and global optimization of high-efficiency thermophotovoltaic systems

Despite their great promise, small experimental thermophotovoltaic (TPV) systems at 1000 K generally exhibit extremely low power conversion efficiencies (approximately 1%), due to heat losses such as thermal emission of undesirable mid-wavelength infrared radiation. Photonic crystals (PhC) have the potential to strongly suppress such losses. However, PhC-based designs present a set of non-convex optimization problems requiring efficient objective function evaluation and global optimization algorithms. Both are applied to two example systems: improved micro-TPV generators and solar thermal TPV systems. Micro-TPV reactors experience up to a 27-fold increase in their efficiency and power output; solar thermal TPV systems see an even greater 45-fold increase in their efficiency (exceeding the Shockley–Quiesser limit for a single-junction photovoltaic cell).

14 SOLAR ENERGY↗

Design and experimental testing of the performance of an outdoor LiBr/H{sub 2}O solar thermal absorption cooling system with a cold store

A domestic-scale prototype experimental solar cooling system has been developed based on a LiBr/H{sub 2}O absorption system and tested during the 2007 summer and autumn months in Cardiff University, UK. The system consisted of a 12 m{sup 2} vacuum tube solar collector, a 4.5 kW LiBr/H{sub 2}O absorption chiller, a 1000 l cold storage tank and a 6 kW fan coil. The system performance, as well as the performances of the individual components in the system, were evaluated based on the physical measurements of the daily solar radiation, ambient temperature, inlet and outlet fluid temperatures, mass flow rates and electrical consumption by component. The average coefficient of thermal performance (COP) of the system was 0.58, based on the thermal cooling power output per unit of available thermal solar energy from the 12 m{sup 2} Thermomax DF100 vacuum tube collector on a hot sunny day with average peak insolation of 800 W/m{sup 2} (between 11 and 13.30 h) and ambient temperature of 24 C. The system produced an electrical COP of 3.6. Experimental results prove the feasibility of the new concept of cold store at this scale, with chilled water temperatures as low as 7.4 C, demonstrating its potential use in cooling domestic scale buildings. (author)

14 SOLAR ENERGY↗

Preliminary experimental comparison and feasibility analysis of CO2/R134a mixture in Organic Rankine Cycle for waste heat recovery from diesel engines

This paper presents results of a preliminary experimental study of the Organic Rankine Cycle (ORC) using CO2/R134a mixture based on an expansion valve. The goal of the research was to examine the feasibility and effectiveness of using CO 2 mixtures to improve system performance and expand the range of condensation temperature for ORC system. The mixture of CO 2 /R134a (0.6/0.4) on a mass basis was selected for comparison with pure CO 2 in both the preheating ORC (P-ORC) and the preheating regenerative ORC (PR-ORC). Then, the feasibility and application potential of CO 2 /R134a (0.6/0.4) mixture for waste heat recovery from engines was tested under ambient cooling conditions. Preliminary experimental results using an expansion valve indicate that CO 2 /R134a (0.6/0.4) mixture exhibits better system performance than pure CO 2 . For PR-ORC using CO 2 /R134a (0.6/0.4) mixture, assuming a turbine isentropic efficiency of 0.7, the net power output estimation, thermal efficiency and exergy efficiency reached up to 5.30 kW, 10.14% and 24.34%, respectively. For the fitting value at an expansion inlet pressure of 10 MPa, the net power output estimation, thermal efficiency and exergy efficiency using CO2/R134a (0.6/0.4) mixture achieved increases of 23.3%, 16.4% and 23.7%, respectively, versus results using pure CO2 as the working fluid. Finally, experiments showed that the ORC system using CO2/R134a (0.6/0.4) mixture is capable of operating stably under ambient cooling conditions (25.2-31.5 °C), demonstrating that CO 2 /R134a mixture can expand the range of condensation temperature and alleviate the low-temperature condensation issue encountered with CO 2 . Under the ambient cooling source, it is expected that ORC using CO 2 /R134a (0.6/0.4) mixture will improve the thermal efficiency of a diesel engine by 1.9%.

42 ENGINEERING↗

Improved GaSb-based quantum well laser performance through metamorphic growth on GaAs substrates

The promise of the metamorphic growth paradigm is to enable design freedom of the substrate selection criteria beyond current choices that are limited by lattice matching requirements. A demonstration of this emerging degree of freedom is reported here by directly comparing identical laser structures grown both pseudomorphically on a GaSb substrate and metamorphically on a GaAs substrate. Improved thermal performance of the metamorphic laser material enables a higher output power before thermal roll-over begins. These performance gains are demonstrated in minimally processed gain-guided broad-area type-I lasers emitting close to 2-μm wavelengths and mounted p-side up. Continuous wave measurements at room temperature yield a T{sub 0} of 145 K and peak output power of 192 mW from metamorphic lasers, compared to a T{sub 0} of 96 K and peak output power of 164 mW from identical lasers grown pseudomorphically on GaSb.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Thermal Considerations of Space Solar Power Concepts with 3.5 GW RF Output

This paper presents the thermal challenge of the Space Solar Power (SSP) design concepts with a 3.5 GW radio-frequency (RF) output. High efficiency klystrons are thermally more favored than solid state (butterstick) to convert direct current (DC) electricity to radio-frequency (RF) energy at the transmitters in these concepts. Using klystrons, the heat dissipation is 0.72 GW. Using solid state, the heat dissipation is 2.33 GW. The heat dissipation of the klystrons is 85% at 500C, 10% at 300C, and 5% at 125C. All the heat dissipation of the solid state is at 100C. Using klystrons, the radiator area is 74,500 square m Using solid state, the radiator area is 2,362,200 square m Space constructable heat pipe radiators are assumed in the thermal analysis. Also, to make the SSP concepts feasible, the mass of the heat transport system must be minimized. The heat transport distance from the transmitters to the radiators must be minimized. It can be accomplished by dividing the radiator into a cluster of small radiators, so that the heat transport distances between the klystrons and radiators can be minimized. The area of each small radiator is on the order of 1 square m. Two concepts for accommodating a cluster of small radiators are presented. If the distance between the transmitters and radiators is 1.5 m or less, constant conductance heat pipes (CCHPs) are acceptable for heat transport. If the distance exceeds 1.5 m, loop heat pipes (LHPs) are needed.

Choi, Michael K.↗

Conceptual design of an advanced Stirling conversion system for terrestrial power generation

A free piston Stirling engine coupled to an electric generator or alternator with a nominal kWe power output absorbing thermal energy from a nominal 100 square meter parabolic solar collector and supplying electric power to a utility grid was identified. The results of the conceptual design study of an Advanced Stirling Conversion System (ASCS) were documented. The objectives are as follows: define the ASCS configuration; provide a manufacturability and cost evaluation; predict ASCS performance over the range of solar input required to produce power; estimate system and major component weights; define engine and electrical power condidtioning control requirements; and define key technology needs not ready by the late 1980s in meeting efficiency, life, cost, and with goalds for the ASCS.

Source record↗

Improved Electrical Load Match In California By Combining Solar Thermal Power Plants with Wind Farms

California with its hydro, geothermal, wind, and solar energy is the second largest producer of renewable electricity in the United States (Washington state is the largest producer of renewable energy electricity due to high level of hydro power). Replacing fossil fuel electrical generation with renewable energy electrical generation will decrease the release of carbon dioxide into the atmosphere which will slow down the rapid increase in global warming (a goal of the California state government). However, in order for a much larger percentage of the total electrical generation in California to be from renewable energies like wind and solar, a better match between renewable energy generation and utility electrical load is required. Using wind farm production data and predicted production from a solar thermal power plant (with and without six hours of storage), a comparison was made between the renewable energy generation and the current utility load in California. On a monthly basis, wind farm generated electricity at the three major wind farm areas in California (Altamont Pass, east of San Francisco Bay area; Tehachapi Pass in the high desert between Tehachapi and Mojave; and San Gorgonio Pass in the low desert near Palm Springs) matches the utility load well during the highest electrical load months (May through September). Prediction of solar thermal power plant output also indicates a good match with utility load during these same high load months. Unfortunately, the hourly wind farm output during the day is not a very good match to the utility electrical load (i.e. in spring and summer the lowest wind speed generally occurs during mid-day when utility load is highest). If parabolic trough solar thermal power plants are installed in the Mojave Desert (similar to the 354 MW of plants that have been operating in Mojave Desert since 1990) then the solar electrical generation will help balance out the wind farm generation since highest solar generated electricity will be during mid-day. Adding six hours of solar thermal storage improved the utility load match significantly in the evening and reliability was also improved. Storage improves reliability because electrical production can remain at a high level even when there are lulls in the wind or clouds decrease the solar energy striking the parabolic trough mirrors. The solar energy from Mojave Desert and wind energy in the major wind farm areas are not a good match to utility load during the winter in California, but if the number of wind farms were increased east of San Diego, then the utility renewable energy match would be improved (this is because the wind energy is highest during the winter in this area). Currently in California, wind electrical generation only contributes 1.8% of total electricity and solar electrical generation only contributes 0.2%. Combining wind farms and solar thermal power plants with storage would allow a large percentage of the electrical load in California to be met by wind and solar energy due to a better match with utility load than by either renewable resource separately.

14 SOLAR ENERGY↗

Modeling Flexible Generator Operating Regions via Chance- constrained Stochastic Unit Commitment

Here, we introduce a novel chance-constrained stochastic unit commitment model to address uncertainty in renewables' production uncertainty in power systems operation. For most thermal generators,underlying technical constraints that are universally treated as "hard" by deterministic unit commitment models are in fact based on engineering judgments, such that system operators can periodically request operation outside these limits in non-nominal situations, e.g., to ensure reliability. We incorporate this practical consideration into a chance-constrained stochastic unit commitment model, specifically by in-frequently allowing minor deviations from the minimum and maximum thermal generator power output levels. We demonstrate that an extensive form of our model is computationally tractable for medium-sized power systems given modest numbers of scenarios for renewables' production. We show that the model is able to potentially save significant annual production costs by allowing infrequent and controlled violation of the traditionally hard bounds imposed on thermal generator production limits. Finally, we conduct a sensitivity analysis of optimal solutions to our model under two restricted regimes and observe similar qualitative results.

42 ENGINEERING↗

Utility-Scale Power Tower Solar Systems: Performance Acceptance Test Guidelines

The purpose of these Guidelines is to provide direction for conducting performance acceptance testing for large power tower solar systems that can yield results of a high level of accuracy consistent with good engineering knowledge and practice. The recommendations have been developed under a National Renewable Energy Laboratory (NREL) subcontract and reviewed by stakeholders representing concerned organizations and interests throughout the concentrating solar power (CSP) community. An earlier NREL report provided similar guidelines for parabolic trough systems. These Guidelines recommend certain methods, instrumentation, equipment operating requirements, and calculation methods. When tests are run in accordance with these Guidelines, we expect that the test results will yield a valid indication of the actual performance of the tested equipment. But these are only recommendations--to be carefully considered by the contractual parties involved in the Acceptance Tests--and we expect that modifications may be required to fit the particular characteristics of a specific project.

14 SOLAR ENERGY↗

Feasibility Study of Solar Dome Encapsulation of Photovoltaic Arrays

The technical and economic advantages of using air-supported plastic enclosures to protect flat plate photovoltaic arrays are described. Conceptual designs for a fixed, latitude-tilt array and a fully tracking array were defined. Detailed wind loads and strength analyses were performed for the fixed array. Detailed thermal and power output analyses provided array performance for typical seasonal and extreme temperature conditions. Costs of each design as used in a 200 MWe central power station were defined from manufacturing and material cost estimates. The capital cost and cost of energy for the enclosed fixed-tilt array were lower than for the enclosed tracking array. The enclosed fixed-tilt array capital investment was 38% less, and the levelized bus bar energy cost was 26% less than costs for a conventional, glass-encapsulated array design. The predicted energy cost for the enclosed fixed array was 79 mills/kW-h for direct current delivered to the power conditioning units.

Source record↗

Space Power Free-Piston Stirling Engine Scaling Study

The design feasibility study is documented of a single cylinder, free piston Stirling engine/linear alternator (FPSE/LA) power module generating 150 kW-electric (kW sub e), and the determination of the module's maximum feasible power level. The power module configuration was specified to be a single cylinder (single piston, single displacer) FPSE/LA, with tuning capacitors if required. The design requirements were as follows: (1) Maximum electrical power output; (2) Power module thermal efficiency equal to or greater than 20 percent at a specific mass of 5 to 8 kg/kW(sub e); (3) Heater wall temperature/cooler wall temperature = 1050 K/525 K; (4) Sodium heat-pipe heat transport system, pumped loop NaK (sodium-potassium eutectic mixture) rejection system; (5) Maximum power module vibration amplitude = 0.0038 cm; and (6) Design life = 7 years (60,000 hr). The results show that a single cylinder FPSE/LA is capable of meeting program goals and has attractive scaling attributes over the power range from 25 to 150 kW(sub e). Scaling beyond the 150 kW(sub e) power level, the power module efficiency falls and the power module specific mass reaches 10 kg/kW(sub e) at a power output of 500 kW(sub e). A discussion of scaling rules for the engine, alternator, and heat transport systems is presented, along with a detailed description of the conceptual design of a 150 kW(sub e) power module that meets the requirements. Included is a discussion of the design of a dynamic balance system. A parametric study of power module performance conducted over the power output range of 25 to 150 kW(sub e) for temperature ratios of 1.7, 2.0, 2.5, and 3.0 is presented and discussed. The results show that as the temperature ratio decreases, the efficiency falls and specific mass increases. At a temperature ratio of 1.7, the 150 kW(sub e) power module cannot satisfy both efficiency and specific mass goals. As the power level increases from 25 to 150 kW(sub e) at a fixed temperature ratio, power module efficiency is seen to increase slightly, but at the expense of increased specific mass. An empirical equation relating power module thermal efficiency as a function of power module specific mass, power output, and temperature ratio is developed. Alternative configurations to the single cylinder, direct coupled linear alternator approach are also evaluated, but are shown to have technical drawbacks that lessen their attractiveness. The dynamic balance assembly mass (moving mass and structure) represents 20 to 30 percent of the total single cylinder power module mass. Joining two modules in a balanced opposed configuration eliminates the need for the balancer, and a hot end junction can be made without significant addition of structural mass. Recommendations are made for evaluation of advanced heat pipe concepts, tests of radial flow heat exchangers, and evaluation of high temperature alternator materials.

Jones, D.↗

Economic viability of using thermal energy storage for flexible carbon capture on natural gas power plants

Fossil fuel-based power plants generate 80% of the electricity in the United States and provide a reliable generation source for both base and peak power demands. These plants are expected to adapt to changes in environmental policies that will require carbon management with carbon capture and storage (CCS) representing a possible solution. Current solvent-based CCS has a detrimental impact on a power plant's performance due to large heat loads required for carbon capture solvent regeneration. This parasitic load restricts the power plant's output and operation flexibility. Therefore, this study evaluates the feasibility of using thermal storage technologies for natural gas combined cycle (NGCC) power plants coupled with CCS to minimize the impact of solvent regeneration and enable the plant to operate at peak power output. Thermal storage can minimize the impact of CCS on the power plant by providing the heat load required for solvent regeneration during times of peak demand which will allow the plant to operate unrestricted and at full power. In total, fifteen unique thermal storage configurations were evaluated from three thermal storage categories: Brayton cycle heat pump, vapor compression heat pump, and heat recovery steam generator steam extraction for storage. The viability of these systems was determined by evaluating each configuration on thousands of real-world Locational Marginal Pricing (LMP) profiles from the New York Independent System Operator and California Independent System Operator electricity markets using a techno-economic analysis. Afterwards, results were compared to the performance of a base power plant (NGCC with CCS and no thermal storage) to determine the impact of thermal storage on power plant economics. Overall, six of the thermal storage configurations performed better than base CCS enabled power plant on between 11.5% and 38.7% of the LMP signals evaluated. The best performing configuration was a vapor compression heat pump that used flue gas as the working fluid and had both hot and cold thermal storage units. This configuration performed better than the base CCS power plant on 38.7% of the LMP profiles. The results of this study show thermal storage can mitigate the economic impact of carbon capture solvent regeneration on NGCC power plants. Discussion focuses on the impact of electricity pricing on the optimal thermal storage system, the advantages and disadvantages of the systems evaluated, and identifies limitations with the study.

25 ENERGY STORAGE↗

ORNL Input to GDSA Repository Systems Analysis FY21

This document satisfies the M3 milestone M3SF-21OR010304082 titled “ORNL Input to GDSA Repository Systems.” This document describes the current status of Oak Ridge National Laboratory’s (ORNL’s) efforts related to analyses of dual-purpose canister (DPC) disposal in unsaturated alluvium with a focus on thermal hydrological constraints on criticality timing and power output. This analysis updates previous analyses of thermal hydrological constraints on timing and power output of a potential criticality event in Dual-Purpose Canisters (DPCs) in a hypothetical repository in unsaturated alluvium using a more realistic representation of heat transport inside dry DPCs. PFLOTRAN was used for the simulations of multiphase thermal hydrology near a single DPC. The scenario considers a DPC failure at 9000 years, allowing water to enter and eventually fill the DPC. Once the DPC is filled to a level that could support a criticality event, different values for criticality power output were added to the decay heat. The main objective is to bound the power output that could be produced by a criticality event without driving water out of the package. For the conditions analyzed here, following a package breach, the alluvial formation could supply enough water to allow enough accumulation in the DPC to support a criticality event. However, the power output that would be generated is limited to modest values by loss of water moderator due to evaporation and vapor diffusion. In the reference case scenario, the DPC would not start to fill with water until about 16,000 years post closure and would not fill to a level that allows a criticality event until approximately 25,000 years post closure. The long-term average power output that could be sustained without driving off the water and terminating the criticality event is limited to approximately 100 W. Sensitivity to assumed conditions and parameters in the reference case, especially the deep percolation rate, need to be addressed but could not be undertaken because of numerical failures of the PFLOTRAN code running in general mode in the dry conditions of an unsaturated alluvium repository

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Latent Heat Reservoirs for Thermal Management of QCW Laser Diodes

There is great interest in improving the thermal management of laser diodes intended for use as pumps in inertial confinement fusion systems. Laser diode power is currently constrained by heat dissipation in the diodes. Diodes typically dissipate a quantity of heat that is comparable to their optical power output. This heating of the diode junction causes a thermal rollover that prevents the output power from scaling linearly with current drive, and also results in reliability limits due to catastrophic failure at diode mirror facets. For the pulsed, quasi-continuous wave (QCW) operating mode employed for LIFE and certain DOD applications, {approx}5 kW/cm{sup 2} of heat must be removed on timescales of {approx}100{micro}s, which is determined by thermal paths located within {approx}200 {micro}m of the laser junction. For these reasons, QCW thermal management is extremely challenging. Reducing the diode junction temperature enables more efficient operation, reduced thermal chirp, and operation at higher output power without compromised reliability - which improves the diode costs as measured in $/W. We have proposed the use of latent heat reservoirs to improve thermal management of diodes used in pulsed, quasi-continuous wave (QCW) operation. Our basic concept involves placement of a reservoir of low-melting-point metal within a few hundred microns of the laser junction, as in Fig. 1-1. This metal's latent heat of fusion maintains a nearly constant temperature (like a cold plate) in the very near vicinity of the diode junction. This cold reservoir creates large thermal gradients, which in turn are anticipated to drive a large heat flow from the diode. In contrast, conventional QCW devices rely on thermal diffusion into a large solid mass which cannot be held at a fixed temperature, which significantly limits the thermal extraction. Our operational concept involves phase changes within the reservoir during every QCW pulse. During the early portion of the pulse, heating of the diode and its surrounding material initiates melting within the latent heat reservoir. This phase change results in a near-constant reservoir temperature that facilitates heat transfer. During the long ({approx}100 ms) time between QCW pulses, the reservoir metal resolidifies. A simple back-of-the-envelope calculation based on Gallium metal shows that a 50 {micro}m thick Gallium reservoir is sufficient to absorb all heat generated by a 350 {micro}s pulse at 5 kW/cm{sup 2}. While this calculation shows that a latent heat reservoir can provide sufficient capacity to handle the magnitude of heat generated, it does not address the transient change in the diode junction temperature, which depends on details the heat flow into and through the reservoir. For this reason, we undertook a set of numerical experiments to quantitatively assess the impact of latent heat reservoirs on junction temperature. This report documents the results of these simulations.

42 ENGINEERING↗