Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Energy transfer from a pulsed thermal source to He II below 0.3 K.

Results of measurements of the angular distribution of the energy flux radiated from a pulsed heater immersed in He II at low temperatures (around 230 mK). It is shown that the energy transfer from a pulsed carbon heater at a relatively high temperature to ambient liquid helium maintained at low temperature cannot be adequately described by the phonon-coupling models. The experimental data on the velocity and angular distribution of the energy flux radiated from the plane of the heater indicate that the energy from the heater is transferred to a layer of hot helium adjacent to the surface of the heater and that this layer acts as the effective source of excitations radiated into the ambient liquid helium. The extent and shape of this source depend on the total energy flux produced by the heater.

Pfeifer, C. D.↗

Evidence for inhomogeneous thermal sources of two similar solar spike event of 1978, May 5 and December 4

Two short duration single spike events of 1978 May 5 and December 4 exhibit similar time profiles in the microwave and hard X-ray ranges, indicating emission from compact sources. Microwave spectral observations exhibit inhomogeneities present in the source parameters. The existence of fine time structures in the microwave time profiles at 10.4 GHz from Berne are interpreted as a signature of the dynamics of a disturbance travelling through the souce at the ion-sound speed. Stereoscopic observations with the hard X-ray detector on the solar orbiter, Helios-2, and the Berne microwave antennae do not indicate any time lag or differences in the time profiles during the impulsive phase. This is taken as evidence for the absence of directionality of emission making beam models unlikely for short duration single spike events.

Wiehl, H. J.↗

Evidence for inhomogeneous thermal sources of two similar solar spike events of 1978 May 5 and December 4

Two short duration single spike solar events of 1978 May 5 and December 4 exhibit similar time profiles in the microwave and hard X-ray ranges, indicating emission from compact sources. Microwave spectral observations exhibit inhomogeneities present in the source parameters. The existence of fine time structures in the microwave time profiles at 10.4 GHz from Berne are interpreted as a signature of the dynamics of a disturbance traveling through the source at the ion-sound speed. Stereoscopic observations with the hard X-ray detector on the solar orbiter, Helios-2, and the Berne microwave antenna do not indicate any time lag or differences in the time profiles during the impulsive phase. This is taken as evidence for the absence of directionality of emission making beam models unlikely for short duration single spike events. Previously announced in STAR as N83-13047

Desai, U.↗

Comparison of photoexcited p-InAs THz radiation source with conventional thermal radiation sources

P-type InAs excited by ultrashort optical pulses has been shown to be a strong emitter of terahertz radiation. In a direct comparison between a p-InAs emitter and conventional thermal radiation sources, we demonstrate that under typical excitation conditions p-InAs produces more radiation below 1.2 THz than a globar. By treating the globar as a blackbody emitter we calibrate a silicon bolometer which is used to determine the power of the p-InAs emitter. The emitted terahertz power was found to be 98{+-}10 nW in this experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma model for thermal X-ray sources

Thermal X ray sources associated with rotating collapsed stars with surrounding plasma shells, discussing plasma density profile and electron distribution in stellar magnetosphere

Coppi, B.↗

Electron temperature and concentration in a thermal atomic oxygen source

A thermal atomic oxygen source for materials screening was built for NASA by Boeing Aerospace. The objective here was to use a microwave interferometer and Langmuir probe to characterize the electron concentration in this thermal atomic oxygen source. Typical operating conditions in the thermal atomic oxygen source were found to produce electron concentrations that were well below the detection threshold of the interferometer (10(exp 8) cm (sup -3)). The researchers calibrated (with the interferometer) the Langmuir probe at an artificially high plasma density and then used the circular and the square Langmuir probes to measure the low electron concentrations that exist during materials exposure tests. Electron concentration was measured as a function of power and position. The electrons were lost to the walls through ambipolar diffusion, and their concentration was accurately described by an equation. The electron concentration was proportional to power squared and decayed exponentially with distance.

Pedrow, Patrick Dennis↗

Thermal evaporation sources for wide-area deposition

A thermal evaporation source includes: a crucible configured to contain a volume of evaporant and a vapor space above the evaporant; a manifold body having within it a hollow expansion chamber that is flowably connected to the vapor space via one or more restriction orifices; one or more effusion nozzles flowably connected to the expansion chamber and exiting an outer surface of the thermal evaporation source, the nozzle(s) oriented to direct an evaporant vapor flow out of the source vertically downward, in one or more horizontal directions, or in one or more directions intermediate between horizontal and vertically downward; and a heater capable of heating some or all of the thermal evaporation source to a temperature sufficient to produce the one or more evaporant vapor flows when a vacuum is applied to the thermal evaporation source.

Birkmire, Robert W.↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

Thermal Inspection of Low Emissivity Surfaces Using a Pulsed Light Emitting Diodes (PLED) Heat Source

Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.

thermal nondestructive evaluation↗

X-RAY POINT-SOURCE POPULATIONS CONSTITUTING THE GALACTIC RIDGE X-RAY EMISSION

Apparently diffuse X-ray emission has been known to exist along the central quarter of the Galactic Plane since the beginning of X-ray astronomy; this is referred to as the Galactic Ridge X-ray emission (GRXE). Recent deep X-ray observations have shown that numerous X-ray point sources account for a large fraction of the GRXE in the hard band (2-8 keV). However, the nature of these sources is poorly understood. Using the deepest X-ray observations made in the Chandra bulge field, we present the result of a coherent photometric and spectroscopic analysis of individual X-ray point sources for the purpose of constraining their nature and deriving their fractional contributions to the hard-band continuum and Fe K line emission of the GRXE. Based on the X-ray color-color diagram, we divided the point sources into three groups: A (hard), B (soft and broad spectrum), and C (soft and peaked spectrum). The group A sources are further decomposed spectrally into thermal and non-thermal sources with different fractions in different flux ranges. From their X-ray properties, we speculate that the group A non-thermal sources are mostly active galactic nuclei and the thermal sources are mostly white dwarf (WD) binaries such as magnetic and non-magnetic cataclysmic variables (CVs), pre-CVs, and symbiotic stars, whereas the group B and C sources are X-ray active stars in flares and quiescence, respectively. In the log N-log S curve of the 2-8 keV band, the group A non-thermal sources are dominant above Almost-Equal-To 10{sup -14} erg cm{sup -2} s{sup -1}, which is gradually taken over by Galactic sources in the fainter flux ranges. The Fe K{alpha} emission is mostly from the group A thermal (WD binaries) and the group B (X-ray active stars) sources.

79 ASTRONOMY AND ASTROPHYSICS↗