Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal desalination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimization-based technoeconomic comparison of multi-stage membrane distillation configurations for hypersaline produced water desalination

Unconventional oil and gas production raises concerns regarding sustainable management of high salinity wastewaters generated in this process. Membrane distillation (MD) is a thermal desalination process capable of treating hypersaline brines such as produced water. The low single pass recovery in MD systems operated in a single stage requires a large recycle stream to achieve the desired recovery, resulting in high energy consumption and operating cost. Multistage configurations in continuous recirculation operation mode offer the potential to reduce the energy intensity of MD systems. However, rigorous analysis is needed to assess the performance of MD configurations when operating in multi-stage mode. Here, we present an optimization-based comparison of economic and energetic performance for five configurations of MD (including DCMD, AGMD, PGMD, CGMD, and VMD) operating in multi-stage continuous recirculation mode. Our findings demonstrate that multistage operation reduces the treatment cost and energy intensity of all MD configurations compared to single stage MD, with the greatest benefit for VMD and PGMD. AGMD with five stages outperforms other configurations with 3.58 $/m 3 feed treatment cost, followed by VMD, CGMD, DCMD, and PGMD with 3.8, 4.2, 5.4, and 9.06$/m 3 feed treatment costs corresponding to twelve, eight, eight, and sixteen stages, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scale-bridging Optimization Framework for Desalination Integrated Produced Water Networks

Produced water (PW) management poses a major challenge to U.S. oil and gas development. Due to freshwater scarcity and PW injection curtailments, desalination may become a necessity in some parts of the country. Integrating rigorous desalination process models within a produced water network for co-optimization of desalination design and network operation can be challenging to scale-up due to computational complexity. In this work we use the trust region filter framework to decompose the integrated optimization problem into an optimization master problem consisting of the network model and simplified surrogates for the desalination units and an optimization sub problem for the rigorous desalination unit model. The approach is demonstrated on a multiperiod produced water network from the PARETO library with thermal desalination units.

Naik, Sakshi↗

Integrating Solar Energy, Desalination, and Electrolysis

Solar electricity enables the advancement and deployment of technologies that are strongly influenced by clean energy availability and cost. The economics of both desalination and hydrogen production from water electrolysis are dominated by the cost of energy, and the availability of inexpensive solar energy creates markets and offers incentives to the desalination and electrolyzer industries. In this report the production of high-purity water and hydrogen from seawater is focused on. Current electrolyzers require deionized water so they need to be coupled with desalination units. It is shown that such coupling is cost effective in hydrogen generation, and it also offers benefits to thermal desalination, which can utilize waste heat from electrolysis. Furthermore, such coupling can be optimized when electrolyzers operate at high current density, using low-cost solar and/or wind electricity, as such operation increases both hydrogen production and heat generation. Results of technoeconomic modeling of polymer electrolyte membrane electrolyzers define thresholds of electricity pricing, current density, and operating temperature that make clean electrolytic hydrogen cost competitive with hydrogen from steam methane reforming (SMR). By using 2020 hourly electricity pricing in California and Texas, it is estimated that hydrogen can be produced from seawater in coupled desalination-electrolyzer systems at prices near $2 kg -1 H 2 , reaching cost parity with hydrogen produced from SMR.

14 SOLAR ENERGY↗

The Levelized Cost of Exergy Framework

Exergy is the amount of energy within a substance or within a transfer of energy that can be used to produce work or some other useful output when interacting with some reference environment. Two different energy systems that produce the same output with the same exergetic efficiency must necessarily have the same amount of exergy input, even if the amount of energy input to the two systems is vastly different. For example, a low-grade heat-driven desalination would require far more energy input than a reverse osmosis (RO) plant producing the same amount of water, but if their exergetic efficiencies were the same, they would require the same amount of exergy input. Thus, comparisons between different energy sources on the basis of energy is not always appropriate. Instead, a comparison on a per unit exergy basis provides more insight on the cost-effectiveness of different energy sources and systems. In this presentation, we describe a framework for analyzing the levelized cost of exergy (LCOEx) for both inputs and outputs of various energy systems. Our framework illustrates how the cost per unit exergy of a system's energy source, as well as the exergetic efficiency of the system, greatly affect the cost of the system output. We use the levelized cost of electricity as a benchmark value for LCOEx, due to electricity's ubiquity as an energy source, and because it is relatively inexpensive on a per unit exergy basis. The LCOEx of various heat sources are then compared to the LCOEx of electricity. Medium- and high-grade industrial heat (> 150 degrees C) produced by natural gas tends to have an LCOEx on par with electricity. This is due to the low cost of natural gas, as well as the high exergy content of heat at higher temperatures. Meanwhile, low-grade heat tends to be an expensive exergy source, owing to the low exergy content of the low-grade heat. We first apply our framework to desalination, where RO has come to dominate, due to the low LCOEx of the energy source (electricity) and relatively high exergetic efficiency of RO compared to thermal desalination systems. We then use this framework to highlight an opportunity for dehumidification systems to experience a similar cost improvement as desalination has. If an electrically-driven, high exergetic efficiency dehumidification system were developed (such as the membrane-based dehumidification systems proposed in literature), it would use a low cost exergy source with a high exergetic efficiency and could potentially lower the cost of dehumidification in the way that RO has done for desalination. Finally, we apply our framework to various fuels (natural gas, hydrogen, gasoline, etc.) and energy systems across different sectors (desalination, dehumidification, vehicles, etc.) to understand the variation in the cost of exergy input and exergetic efficiency of different systems and technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimization strategies for produced water networks with integrated desalination facilities

Optimal management and desalination of produced water is a major challenge for U.S. oil and gas development. Integrating rigorous desalination models into multi-period produced water network optimization problems presents several hurdles, which need to be tackled using advanced optimization strategies. Here, in this work, a novel multi-period produced water network formulation with separate solid and liquid flows is introduced to avoid singularities at zero flows. Rigorous steady state desalination models based on mechanical vapor recompression are embedded at the desalination sites in the network model. An integrated optimization formulation is developed to co-optimize the design of desalination units along with the operation of the network. Furthermore, a more robust approach based on the trust region filter method is developed to efficiently integrate complex desalination models into the multi-period planning problem. Both optimization approaches are demonstrated on a produced water network from the PARETO library (Drouven et al., 2022) using thermal desalination units. Our results show that while the TRF and integrated approaches have comparable solve times, the TRF approach has better performance reliability in terms of solver convergence. Furthermore, the optimal solution obtained by embedding rigorous models into the network is significantly different than when desalination costs are approximated using simple cost models, which motivates further research in this field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy efficient supercritical water desalination using a high-temperature heat pump: A zero liquid discharge desalination

Supercritical water desalination (SCWD) is zero liquid discharge technology that can potentially control the solubility of different electrolytes. However, SCWD is an energy-intensive process and requires high-quality thermal heat (> 450 °C). This study proposes the integration of a high-temperature heat pump to reduce the SCWD energy requirement. The integrated system energy consumption improves by 36% for 3.5% feed concentration and 14% for 20% feed, and the distillate cost reduces by 15% and 10%. Another benefit of the proposed integration is the system can be operated using only electricity as a heat source, as is the case with commonly used high-recovery thermal desalination technology. The integrated SCWD-heat pump system shows superior performance compared to the commercially used brine concentrator and crystallizer system. It is approximately 20% more energy-efficient for 25% feed concentration and 8% cheaper. Hence, the integrated SCWD-heat pump has the potential to outperform the pre-existing high-recovery desalination technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Loop Thermosyphon Enhanced Solar Collector

A two-phase loop thermosyphon solar collector was developed to transfer thermal energy efficiently and passively from a concentrated solar collector to a thermal desalination process. The two-phase flow in the loop thermosyphon is driven by a difference in gravitational pressure head between the liquid return line and the two-phase riser located between the evaporator and condenser. A numerical model incorporating mass, energy, and pressure drop balances was developed to predict system performance and use as a design tool. Three iterations of loop thermosyphon solar collectors were designed, fabricated, and tested to validate the numerical analysis and demonstrate system integration. Additionally, a novel solar receiver design was evaluated based on volumetric absorption of the concentrated sunlight by an optically absorptive two-phase working fluid. Life tests were performed to evaluate the working fluid thermal stability and resistance to ultraviolet degradation. A glass receiver tube and associated glass-to-metal junctions were developed. Finally, a full-scale loop thermosyphon was integrated with a parabolic trough solar collector and tested on-sun.

14 SOLAR ENERGY↗

A Cost-Performance Analysis of a Sodium Heat Engine for Distributed Concentrating Solar Power

We present that a sodium thermal electrochemical converter (Na-TEC) generates electricity directly from heat through isothermal expansion of sodium ions across a beta"-alumina solid-electrolyte. This heat engine has been considered for use with conventional concentrating solar power (CSP) systems before. However, unlike previous single-stage devices, the improved design uses two stages with an interstage reheat, allowing more economical and efficient conversion up to 29% at a hot side temperature of 850 °C. Herein, a cost-performance analysis for this improved design assesses opportunities for distributed-CSP in the context of micro-combined heat and power systems. A high-level techno-economic analysis (TEA) is presented that explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per W e are feasible, which equate to LCOEs from 6.9 to 17.2 cents kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗

Empirical prediction of saline water atomization pressure loss and spray phase change using local flow pressure analysis

A pressure analysis technique was developed to obtain spray spatial evaporation profile in a thermal desalination process. The technique can replace temperature-based evaporation measurement methods that are challenged by liquid-phase interference. It also provides an alternative to optical methods with high cost and complexity. Fundamental analysis was developed to determine local humidity ratios from changes in local static and dynamic pressures. The analysis was applied to data obtained from an external mixing air-assist atomizer. An empirical model was developed for the pressure loss in atomization process and was used in the analysis of humidity ratio. The results were used to develop empirical correlations for local humidity ratio in spray mediums using inlet conditions. Utilizing inlet conditions to predict evaporation profiles is an important contribution as it eliminates the need to take local spray measurements. Obtaining local data is often difficult and expensive; Our method and correlation circumvent the need for that. Finally, the correlations presented in this paper apply to saline water sprays with total dissolved salt of 0-10 wt%. The salinity-specific correlations are accurate to within ±10% of experimental data. The individual models were aggregated into a unified correlation for salinities within 0-10 wt%. The unified correlation is accurate to within ±18% of experimental data.

42 ENGINEERING↗

Utilizing waste heat in wastewater treatment plants for water desalination: Modeling and Multi-Objective optimization of a Multi-Effect desalination system using Decision Tree Regression and Pelican optimization algorithm

This paper examines the feasibility of using waste heat from wastewater treatment plants (WWTPs) for water desalination. A model was developed to utilize waste heat from the gensets at As Samra WWTP in Jordan, using real data and TRNSYS® software to calculate available waste heat. The desalination process was then modeled with ASPEN PLUS® software, focusing on multi-effect desalination (MED). Both series and parallel configurations for the MED system were compared. The study investigated the effects of system feeding flow rate, feeding pressure, and heat input on productivity, performance ratio, and recovery ratio. The study also introduces a novel optimization technique combining machine learning and modern optimization algorithms to maximize system productivity and performance. Initially, a decision tree regression (DTR) model is developed to establish relationships between key independent variables (flow rate, feed pressure, and heat input) and dependent variables (productivity, performance ratio, and recovery ratio). The Pelican Optimization Algorithm (POA) is then used to identify the optimal values of the independent variables for maximum productivity and performance. The results show that using a series configuration yields a system productivity of 3984.2 kg/hr, a performance ratio of 3.78, and a recovery ratio of 0.991 at a feed flow rate of 4000 kg/hr, feed pressure of 3 bars, and heat input of 719 kW. Optimal productivity (4421 kg/hr), performance ratio (3.81), and recovery ratio (0.851) are achieved at a feed flow rate of 5166 kg/hr, feed pressure of 3.2 bars, and heat input of 794 kW. In conclusion, the techno-economic assessment indicates a levelized cost of water of 1.63 USD/m 3 for parallel configurations and 1.65 USD/m 3 for series configurations, with a payback period of less than two years.

42 ENGINEERING↗

Slippery liquid infused porous surface (SLIPS) condensers for high efficiency air gap membrane distillation

Abstract To address growing water scarcity, we must improve the energy efficiency of thermal desalination technologies such as air gap membrane distillation. However, promising functional materials such as slippery liquid infused porous surfaces have not yet implemented for any desalination technology. Here, we fabricate and test slippery liquid infused porous surfaces (using Krytox 16,256 lubricant and CuO nanostructures) in an air gap membrane distillation apparatus. System-level transport models, validated by experimental data, establish a framework for improving performance through enhanced condensation surfaces. Results are obtained across a range of temperatures (50–80 °C), salinities (5–105 g/kg), and module lengths. We find that small air gap thickness and efficient droplet shedding significantly improves performance. The CuO Krytox process achieves these with a conductive-self-limiting coating, high nanostructure rugosity, strong covalent and metallic bonding, high hydrophobicity, minimal droplet pinning sites, and ultra-low contact angle hysteresis. The greatest efficiency enhancement from SLIPS is derived from the improved droplet shedding, which allows for reduced gap sizes without flooding, and is further augmented by the increased permeate flux.

Yogi, Yashwant S.↗

An in-situ conductometric apparatus for physicochemical characterization of solutions and in-line monitoring of separation processes at elevated temperatures and pressures

Specific conductance and frequency-dependent resistance (impedance) data are widely utilized for understanding the physicochemical characteristics of aqueous and non-aqueous fluids and for evaluating the performance of chemical processes. However, the implementation of such an in-situ probe in high-temperature and high-pressure environments is not trivial. This work provides a description of both the hardware and software associated with implementing a parallel-type in-situ electrochemical sensor. The sensor can be used for in-line monitoring of thermal desalination processes and for impedance measurements in fluids at high temperature and pressure. Further, a comparison between the experimental measurements on the specific conductance in aqueous sodium chloride solutions and the conductance model demonstrate that the methodology yields reasonable agreement with both the model and literature data. A combination of hardware components, a software-based correction for experimental artifacts, and computational fluid dynamics (CFD) calculations used in this work provide a sound basis for implementing such in-situ electrochemical sensors to measure frequency-dependent resistance spectra.

47 OTHER INSTRUMENTATION↗

Conducting thermal energy to the membrane/water interface for the enhanced desalination of hypersaline brines using membrane distillation

Membrane distillation (MD) is a membrane-based thermal desalination process capable of treating hypersaline brines. Standard MD systems rely on preheating the feed to drive the desalination process. However, relying on the feed to carry thermal energy is limited by a decline of the thermal driving force as the water moves across the membrane, and temperature polarization. In contrast, supplying heat directly into the feed channel, either through the membrane or other channel surfaces, has the potential of minimizing temperature polarization, increasing single-pass water recoveries, and decreasing the number of heat exchangers in the system. When solar thermal energy can be utilized, particularly if the solar heat is optimally delivered to enhance water evaporation and process performance, MD processes can potentially be improved in terms of energy efficiency, environmental sustainability, or operating costs. Here we describe an MD process using layered composite membranes that include a high-thermal-conductivity layer for supplying heat directly to the membrane-water interface and the flow channel. Here, the MD system showed stable performance with water flux up to 9 L/m 2 /hr, and salt rejection >99.9% over hours of desalinating hypersaline feed (100 g/L NaCl). In addition to bench-scale system, we developed a computational fluid dynamics model that successfully described the transport phenomena in the system.

42 ENGINEERING↗

The Internal Compound Parabolic Concentrator (ICPC): a Novel Low Cost Solar Thermal Collection System for Desalination Processes

The research team at UC Merced designed, prototyped, and tested (1) a novel low cost non-tracking solar thermal collector/concentrator called the Integrated Compound Parabolic Concentrator (ICPC) and (2) a low-cost phase-change thermal energy storage system. Together these technologies can significantly reduce the levelized cost of heat from solar thermal sources while also incorporating features of dispatchability and portability. The ICPC allows elevated temperature and efficiency in a low cost, non-tracking collector. The collector has demonstrated 60% ±4% solar to thermal modules efficiency at fluid outlet temperature of 120°C. The raw material cost of the collector system is reduced by utilizing low cost aluminum minichannels. The collector design is also amenable to economic mass production. A 200 tube, 10 kW prototype array was constructed and tested, yielding over 6 kWh/day on average at outlet fluid temperature exceeding 120°C.

14 SOLAR ENERGY↗

Generating Buoyancy-Driven Convection in Membrane Distillation

Membrane distillation (MD) is a thermally-driven desalination process that can treat hypersaline brines. Considerable MD literature has focused on mitigating temperature and concentration polarization. This literature largely neglects that temperature and concentration polarization increase the feed density near the membrane. With gravity properly oriented, this increase in density could trigger buoyancy-driven convection and increase permeate production. Convection could also be strengthened by heating the feed channel wall opposite the membrane. To investigate that possibility, we perform a series of experiments using a plate-and-frame direct contact MD system with an active membrane area of 300 cm2 and a feed channel wall heated using a resistive heater. The experiments measure the average transmembrane permeate flux for two gravitational orientations, feed Reynolds numbers between 128 and 1128, and wall heat fluxes up to 12 kW/m2. The results confirm that with gravity properly oriented, wall-heating can trigger buoyancy-driven convection for a wide range of feed Reynolds numbers, and increase permeate production between roughly 20 and 130 %. We estimate, however, that at high Reynolds numbers (Re > 800), more than 70 % of the wall heat is carried out of the MD system by the feed flow, without contributing to permeate production. This suggests the need for longer membranes and heat recovery steps in any future practical implementation.

buoyancy-driven convection↗