Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal envelope performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Influence of the concentration ratio on the thermal and economic performance of parabolic trough collectors

The thermal and economic performance of parabolic trough collectors (PTCs) and PTCs with double glass envelope (DGE-PTCs) are analyzed in this work. A model including thermal and optical effects is developed to evaluate the efficiency of vacuum and air-filled DGE-PTCs, while an economic model based on two commercial PTCs (SkyTrough and Ultimate Trough collectors) was developed to assess the economic performance. The efficiency and thermal output per unit cost of the proposed DGE-PTCs are analyzed as a function of the concentration ratio and are respectively compared with the thermal and economic performance of traditional and commercial PTCs. The optimum concentration ratio for maximum thermal performance varies from 11.0 to 23.3 for operation temperatures (T HTF ) between 100 degrees C and 400 degrees C, while the optimum concentration ratio for maximum economic performance ranges between 28.9 and 33.2 for the SkyTrough and between 40.0 and 43.8 for the Ultimate Trough collector designs. Finally, the DGE-PTCs present higher thermal and economic performance at high operating temperatures, which presents a valuable opportunity for implementation in new PTC designs pursuing higher operating temperatures to achieve superior thermal cycle efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerogel from Sustainably Grown Bacterial Cellulose Pellicles as a Thermally Insulative Film for Building Envelopes

Improving building energy performance requires the development of new highly insulative materials. An affordable retrofitting solution comprising a thin film could improve the resistance to heat flow in both residential and commercial buildings and reduce overall energy consumption. Here, we propose cellulose aerogel films formed from pellicles produced by the bacteria Gluconacetobacter hansenii as insulation materials. We studied the impact of the density and nanostructure on the aerogels’ thermal properties. A thermal conductivity as low as 13 mW/(K·m) was measured for native pellicle-based aerogels that were dried as-is with minimal post-treatment. The use of waste from the beer brewing industry as a solution to grow the pellicle maintained the cellulose yield obtained with standard Hestrin-Schramm media, making our product more affordable and sustainable. In the future, our work can be extended through further diversification of food wastes as the substrate sources, facilitating higher potential production and larger applications.

36 MATERIALS SCIENCE↗

An Instrumented Capsule Design to Measure Thermal Conductivity in Miniature UO2 Specimens

Numerous separate effects irradiations of miniature nuclear fuel specimens have been conducted in the High Flux Isotope Reactor (HFIR) under the experimental platform designated as MiniFuel. MiniFuel is a static irradiation capability in which microstructural evolution and fuel performance phenomena are observed during postirradiation examination thereby offering a snapshot of the terminal fuel characteristics. This approach inherently requires fielding an irradiation where the experimental conditions are determined using predictive models and the pertinent outcomes are measured at the end of the test. Static irradiations can provide useful insights to the relationships between fuel performance and the pivotal irradiation conditions, namely temperature and burnup, but the ability to monitor fuel performance in situ would further support fuel development and qualification. To this end, an instrumented experiment design is being developed at Oak Ridge National Laboratory to capture thermal conductivity degradation and fission gas release during HFIR irradiation. These phenomena will be monitored using unique capsule designs that each target a different phenomenon. This paper details the thermal conductivity capsule (TCC) design and its expected performance envelope as determined using computer models. Each TCC will contain a miniature UO2 disc specimen (~0.5 mm thick × 5 mm diameter) sandwiched between metallic slugs with embedded thermocouples. The coupling of in situ temperature measurements, known thermal conductivity of the metallic components, and heat generation rates computed using high-fidelity neutronics models make the thermal conductivity measurement possible. This paper describes the reactor physics and heat transfer models used to predict the capsule’s performance and the methodology for calculating the fuel specimen’s thermal conductivity from the thermocouple measurements.

Gorton, Jacob [ORNL] (ORCID:0000000269806083)↗

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multimetallic Layered Composites (MMLCs) for Rapid, Economical Advanced Reactor Deployment (Final Report)

This project focused on the development of multi-metallic layered composites (MMLCs) for advanced fission reactor technologies. There are many instances where one alloy or material simply cannot meet all the demands thrown at it by a reactor system, or cannot allow it to perform as strongly as one would like. Instead of focusing all our effort on developing one perfect alloy, we seek to leverage the design principle of “separation of functionality,” used in many other arenas in design, to boost performance beyond single alloys alone. One illustrative example shows the power of this approach for molten salt-cooled reactors: A three meter tall, three meter diameter reactor vessel made of Incoloy 800 was quoted at $\$$500k in 2018. A Hastelloy N vessel was quoted at $\$$5M. An MMLC vessel, in which a layer of Hastelloy N would be weld-overlaid onto Incoloy 800, was quoted at $\$$700k, and it would achieve the same performance. The potential economic gains of leveraging this approach are therefore substantial. At a minimum, each MMLC would contain one core structural layer and one coolant-facing corrosion-resistant layer. Sometimes, MMLCs required buffer layers, as the structural and corrosion-resistant layers were metallurgically incompatible. In other words, they didn’t always play nice, thus separating layers compatible with both functioned as intermediaries to keep the composite together. However, in doing so we inevitably produce new interfaces, where new issues can arise. Therefore, this project focused on what happens at these interfaces from a combination of high temperatures, irradiation, corrosion, and time. After all, a reactor makes money when it is operating, and outages of any kind erode its economic viability. First, we set out to experimentally prove that MMLCs for at least two advanced reactor systems can be made, today, in US domestic facilities. In this respect we were successful – one MMLC (a Ni-201/Incoloy 800H composite) was successfully made and drawn into two-inch coolant piping. Others were attempted, though new issues relating to cracking in vanadium layers for one and radiation damage performance of the corrosion-resistant layer in another prevented us from moving further in those specific arenas – these are engineering problems which deserve continued focus after this project. Additional experimental work focused on long-term corrosion testing of the outermost layers of the salt-cooled and liquid lead-cooled MMLC concepts, which would then be fed into predictions of how long the MMLCs could last. Next, computational (thermodynamics and atomistic) simulation studies studied how much we expect the interfaces to “blend,” due to the mixing action of neutron irradiation. This eats into both the margin for the structural layer of each MMLC, as dilution from the corrosion-resistant layer into the structural layer would decrease the total load-bearing capacity of an MMLC of finite size. On the other hand, dilution of the corrosion-resistant layer into the structural layer further reduced the margin of corrodible material, reducing the lifetime of the MMLC or necessitating extra thickness to be imparted to the MMLC to meet its functional requirements. Work here focused on irradiation-induced segregation to predict new phases which may embrittle the MMLCs, as well as quantifying irradiation-induced mixing at each interface. The results showed that mixing is expected, but it is both steady and therefore predictable, and not lifetime-limiting for most MMLC concepts – it simply has to be accounted for in calculations of reactor performance when utilizing an MMLC. Then, full-core simulations using the experimentally-derived corrosion data, the computationally discovered irradiation-induced mixing data (partially validated by experiment), and existing, benchmarked core designs for large and small sized reactor concepts (one salt-cooled, one lead-cooled) were conducted to quantify any expansion of reactor operating envelopes achieved by utilizing these MMLCs. This new framework, called REX (Reactor Envelope Expansion), incorporates a combination of core neutronics, thermal hydraulics, and the material performance data derived from this project to see how using an MMLC expands advanced fission reactor operating envelopes. It was discovered that in some cases, MMLC utilization does indeed increase the maximum operating temperatures and cycle lengths of reactor concepts, while in other cases it does not. Finally, our tech-to-market (T2M) strategy was not necessarily to create specific embodiments of MMLCs for immediate sale (because getting into the nuclear market is incredibly slow and laden with regulation, this is a long-term goal), but rather immediate stimulation of US industry using the design approach of MMLCs derived from this project. In this respect we were successful, as one of the PhD students funded on this project co-founded Allium Engineering, Inc., which created a stainless steel / low-alloy steel MMLC to function as chloride corrosion-resistant rebar for embedding into concrete structures. Allium Engineering continues to be successful, having recently opened their first factory as of this writing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development and Performance Evaluation of of Active Insulation Systems using Solid-State Thermal Switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs), which dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. Sensitivity studies have provided requirements for the AIS properties and control schemes that can lead to those savings. However, materials and assembly development have not yet achieved a cost-effective product that achieves the required performance. In this study, we present the process to develop an AIS that we will install in a test hut for their performance evaluation. Minimum performance criteria of the AIS system are developed based on Rmin/Rmax ratio, required time and efficiency to switch states and cost estimate. The next step carried out during this study is creating the concept to meet the requirements, predicting the performance by simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to natural weather conditions. The selected approach uses off-the-shelf products to create a materials system that can switch R-value between R~=1 ft2·°F·h/BTU (0.18 m2·K/W) and R~=7 ft2·°F·h/BTU (1.23 m2·K/W and have a switching time of less than one minute between R-high and R-low.

Iffa, Emishaw↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials↗

Impact of Insulation Strategies of Cross-Laminated Timber Assemblies on Energy Use, Peak Demand, and Carbon Emissions

Cross-Laminated Timber (CLT) panels have many structural benefits but do not have much thermal resistance. We have developed a solution to insulate CLT structures that uses high-performance insulation panels that provide R-values up to R40/inch. The CLT panels are made of layers of wood laminates (three, five, seven or more). The solution replaces some of the wood laminates in the CLT production with the insulation panels in a staggered fashion so that the wood laminates maintain contact throughout the panel, ensuring the CLT panel’s structural integrity. The insulated CLT panels have factory-installed water-resistive barriers reducing the installation time by eliminating installing insulation and water-resistive barriers on site. Per simulations, the CLT/insulation panel achieved code-required insulation levels with commonly available insulation materials. The significance of the thermal mass of CLT/insulation hybrid building envelopes was quantified by comparing the whole building energy performance and peak demand of traditional low mass and CLT wall assemblies resulting in up to 7% reduction in peak demand for cooling in Knoxville, TN, in a multifamily building. Buildings contribute over 40 percent of carbon emissions. The proposed CLT/insulation hybrid building envelope addresses both operational and embodied carbon by having high thermal resistances due to the embedded insulation sections and eliminating the use of high embodied carbon materials such as steel and concrete. The carbon benefit is estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing thermal resilience of an assisted living facility during heat waves and cold snaps with power outages

Extreme hot and cold weather events are becoming more frequent, intense, and longer due to climate change. When these events occur coincidentally with power outages, the resulting extreme indoor temperatures pose a severe health hazard for occupants. This study conducted a holistic modeling and analysis of an assisted living facility, where senior residents live, to assess its thermal resilience performance under a six-day heat wave in 2015 and a three-day cold snap in 2021 with power outages. Impacts of 13 energy efficiency measures on thermal resilience and backup power capacity of the facility were evaluated. Three thermal resilience metrics: the SET (standard effective temperature) degree-hours, the Heat Index, and the Hours of Safety, were used and calculated from the EnergyPlus simulation models. Furthermore, major findings are: (1) the facility would suffer from extreme temperatures during the cold and hot events without a power supply, not meeting the passive survivability requirements; (2) most passive envelope measures improve thermal resilience for both hot and cold events, but making the building envelope airtight results in conflicting performance between the hot and cold events; (3) natural ventilation is an effective measure to mitigate summer indoor overheating; and (4) the energy efficiency package can reduce backup power capacity by 19% for the three-day cold snap. It is recommended that building technologies and design strategies be evaluated to consider co-benefits of energy use, thermal resilience, and backup power needs through building energy codes or policies for existing and new buildings, which are transitioning for decarbonization and climate resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Making Small-Volume Heat Pump Water Heaters Larger: A Design Framework for Integrated Phase Change Material Heat Exchangers

Those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. One major barrier to wider HPWH adoption is the added equipment required, which prevents current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). PCMs have been studied extensively in building envelope and HVAC systems, but remain a nascent technology in residential water heating. While water itself has a uniquely high energy storage capacity, PCMs have an even higher energy storage density, thus providing the potential to elevate the performance of 40-gallon HPWHs to that of 50-gallon or larger tanks. This research is part of a larger project that seeks to utilize thermal energy storage to enable decarbonized water heating in low-income communities. In this study, we outline the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. In order to ensure optimal PCM utilization and tank storage capacity, we focus here on co-maximizing surface area and PCM volume in the heat exchangers; therefore, this research targets triply periodic minimal surface (TPMS) lattices. TPMS lattices boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries and offer highly tailorable designs; thus, they pair well with the growing field of additive manufacturing, or 3D printing. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives.

25 ENERGY STORAGE↗

$\mathrm{REX}$: An analytical tool for reactor operating envelope expansion through fuel-clad thermo-mechanics

Here REX, an analytical reactor design tool for the identification and expansion of reactor operating envelopes, is introduced and detailed. Written in MATLAB, REX takes core geometries and axially discretized detector and depletion output from the Serpent neutron transport code and performs full-core, pin-specific thermal-hydraulic and thermo-mechanical calculations. REX identifies the operating envelopes of advanced, solid-fuel nuclear reactors on the basis of their fuel-cladding, fuel-gas, and coolant-cladding interfacial thermo-mechanics. It iteratively pushes coolant inlet temperatures and modifies fuel pin geometries to induce mechanical failure in their original cladding materials at the fullest extent of their fuel cycle lengths and permissible coolant inlet temperatures. It then attempts to expand their operating envelopes by determining the mechanical responses of alternative cladding materials under the same geometric conditions. The result of the REX calculation sequence is a set of 5-D variables describing the temperatures, pressures, geometries, and mechanics of the core as functions of assembly, fuel pin, axial zone, depletion step, and coolant inlet temperature for each candidate cladding material with the limiting fuel pin geometry for the original material.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

Among 32 million multi-family buildings in the United States, approximately 42% have poor or no insulation. Envelope retrofits of these buildings will provide thermal resiliency and enable a pathway to electrification of space heating systems as a result of improved thermal performance. Hydronic Shell (HS) is a technology which combines an insulated retrofit panel with a heating, ventilation and air-conditioning (HVAC) thus enabling both envelope retrofit and space heating electrification. In this study, we used whole building energy simulation to evaluate energy impact of multi-family building retrofit with hydronic shell system. The simulation was performed for four locations of New York, Syracuse, Chicago and Boston. The results from the simulation showed more than 66% cooling energy reduction and more than 88% heating energy reduction from Hydronic Shell retrofit compared to Baseline building in all four locations. This reduction in energy consumption resulted in up to 219 MT reduction in annual CO2 emission. The cost reduction per floor area achieved from HVAC energy consumption reduction using Hydronic Shell retrofit was 0.66 to 0.99 $\$$/ft 2 . The results also showed higher percentage of heating energy reduction comes from the envelope only retrofit and higher percentage of cooling energy reduction comes from the retrofit HVAC system for the four locations under study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BESTEST-GSR (Building Energy Simulation Test - Generation Simulation and Reporting) 2023 [SWR 18-23]

Building Energy Simulation Test (BESTEST) is an NREL-developed method to validate the qualitative performance of different whole building simulations engines relative to each other. https://www.nrel.gov/docs/legosti/old/6231.pdf The purpose of this repository is to generate BESTEST test case models, run simulations, and populate data for ASHRAE Standard 140 reporting spreadsheets for EnergyPlus® based whole building simulation tools. It was originally setup for 2014 version of Standard 140. In May of 2022 it was updated to the 2020 version of Standard 140. This update included updates and additions to existing test suites, the bulk of which was in Section 5.2 (Building Thermal Envelope and Fabric Load Tests). We did not add Section 5.5 Airside HVAC Equipment Performance, but we hope to add that later in 2022. At some point we also hope to add Section 5.2.4 ground modeling, which is currently excluded. Supported Tools The default IDF generation is based on the OpenStudio® CLI, but the workflow supports a 'Bring your own IDF' use case. Additionally, for non-EnergyPlus® based tools the post processing scripts can be used if simulation results are provided as a CSV file.The scripts on this repository should work on Mac, Windows, and Linux. Dependencies Install OpenStudio® 3.4.0 make sure command line can recognize the 'openstudio' command This includes EnergyPlus® 22.1 Install Ruby on your system if it isn't already setup. 2.7 is used for development but other versions may work Since OpenStudio has its own embedded Ruby, which is used for running measures, you don't necessarily have to use a version of Ruby supported by OpenStudio. Install RubyXL Ruby gem This is used to modify Microsoft Excel spreadsheets Install Parallel Ruby gem This allows the CLI to run simulations in parallel

Goldwasser, David↗