Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermodynamic systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fundamental Issues Identified for Thermodynamic Description of Molten Salt Systems

Thermodynamic modeling of the molten salt systems is critical in the design of advanced nuclear power plants, materials recycling, and many other important clean energy applications. As one of the most capable computational thermodynamic approaches, the CALPHAD (Calculation of Phase Diagrams) method has been widely used for multicomponent thermodynamic database development and further support more physics-based modeling. Although considerable CALPHAD modeling efforts for molten salt systems have been made, we found that no evaluation has been performed regarding the unary thermodynamic models for the molten salt systems despite the fact that more than one pure substance database is available for the CALPHAD modeling. Therefore, the thermodynamic descriptions of the pure salts should be critically evaluated to ensure a high-fidelity molten salt thermodynamic database. In this work, we comprehensively analyzed some selected molten salts using different available thermodynamic descriptions from two databases as an example. One is the SSUB database released by the SGTE (Scientific Group Thermodata Europe), and the other is the FactPS database from the FactSage. Finally, the significant discrepancies observed in the thermodynamic description between the existing CALPHAD pure substance databases and experiments call for an urgent effort to improve.

42 ENGINEERING↗

Thermodynamics of the Si-O-H System

Thermodynamic functions for Si(OH)4(g) and SiO(OH)2(g) have been measured using the transpiration method. A second law enthalpy of formation and entropy and a third law enthalpy of formation has been calculated for Si(OH)4. The results are in very good agreement with previous experimental measurements, ab-initio calculations, and estimates.

Jacobson, Nathan S.↗

Thermodynamic Vent System Applied as Propellant Delivery System for Air Force

Responding to a request from the Air Force, NASA Lewis Research Center engineers designed a combination pressure control and propellant delivery system based on thermodynamic vent system (TVS) technology. The Air Force is designing a new type of orbit transfer vehicle that uses energy from sunlight to both propel and power the vehicle. Because this vehicle uses propellant at a substantially slower rate than higher-energy rockets, it needed the Lewis-developed TVS technology for long-duration storage of cryogen propellants. Lewis engineers, in conjunction with industry partners, showed how this TVS technology could also be used to deliver propellant to the thruster. The Air Force has now begun the ground test demonstration phase. After successful completion of ground testing, the Air Force plans to use this technology in a space flight as early as 1999.

Source record↗

Thermodynamic Vent System Test in a Low Earth Orbit Simulation

A thermodynamic vent system for a cryogenic nitrogen tank was tested in a vacuum chamber simulating oxygen storage in low earth orbit. The nitrogen tank was surrounded by a cryo-shroud at -40 F. The tank was insulated with two layers of multi-layer insulation. Heat transfer into cryogenic tanks causes phase change and increases tank pressure which must be controlled. A thermodynamic vent system was used to control pressure as the location of vapor is unknown in low gravity and direct venting would be wasteful. The thermodynamic vent system consists of a Joule-Thomson valve and heat exchanger installed on the inlet side of the tank mixer-pump. The combination is used to extract thermal energy from the tank fluid, reducing temperature and ullage pressure. The system was sized so that the tank mixer-pump operated a small fraction of the time to limit motor heating. Initially the mixer used sub-cooled liquid to cool the liquid-vapor interface inducing condensation and pressure reduction. Later, the thermodynamic vent system was used. Pressure cycles were performed until steady-state operation was demonstrated. Three test runs were conducted at tank fills of 97, 80, and 63 percent. Each test was begun with a boil-off test to determine heat transfer into the tank. The lower tank fills had time averaged vent rates very close to steady-state boil-off rates showing the thermodynamic vent system was nearly as efficient as direct venting in normal gravity.

VanOverbeke, Thomas J.↗

Design and integrated operation of an innovative thermodynamic vent system concept

A unique zero-g thermodynamic vent system (TVS) is being developed by NASA's Marshall Space Flight Center (MSFC) and Rockwell International to meet cryogenic propellant management requirements for future space missions. The design is highly innovative in that it integrates the functions of a spray-bar tank mixer and a TVS. This concept not only satisfies the requirement for efficient tank mixing and zero-g venting but also accommodates thermal conditioning requirements for other components (e.g., engine feed lines, turbopumps, and liquid acquisition devices). In addition, operations can be extended to accomplish tank chill-down, no-vent fill, and emergency venting during zero-g propellant transfer. This paper describes the system performance characterization and future test activities that are part of MSFC's Multipurpose Hydrogen Test Bed (MHTB) program. The testing will demonstrate the feasibility and merit of the design, and serve as a proof-of-concept development activity.

Fazah, Michel M.↗

Solid-State Thermodynamic Vent System (STVS) for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellant condition. By exploiting the vacuum-induced cryocooling (VIC) potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger (HX) can expel some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. Testing proved the effectiveness of the concept by reducing the liquid nitrogen (LN 2 ) boiloff rate and tank pressure by roughly 70% and 77%, respectively, during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Cryogenic Fluid↗

Identification of salt-alloy combinations for thermal energy storage applications in advanced solar dynamic power systems

Thermodynamic calculations based on the available data for flouride salt systems reveal that a number of congruently melting compositions and eutectics exist which have the potential to meet the lightweight, high energy storage requirements imposed for advanced solar dynamic systems operating between about 1000 and 1400 K. Compatibility studies to determine suitable containment alloys to be used with NaF-22CaF2-13MgF2, NaF-32CaF2, and NaF-23MgF2 have been conducted at the eutectic temperature + 25 K for each system. For these three NaF-based eutectics, none of the common, commercially available high temperature alloys appear to offer adequate corrosion resistance for a long lifetime; however mild steel, pure nickel and Nb-1Zr could prove useful. These latter materials suggest the possibility that a strong, corrosion resistant, nonrefractory, elevated temperature alloy based on the Ni-Ni3Nb system could be developed.

Whittenberger, J. D.↗

Liquid Oxygen Thermodynamic Vent System Testing with Helium Pressurization

This report presents the results of several thermodynamic vent system (TVS) tests with liquid oxygen plus a test with liquid nitrogen. In all tests, the liquid was heated above its normal boiling point to 111 K for oxygen and 100 K for nitrogen. The elevated temperature was representative of tank conditions for a candidate lunar lander ascent stage. An initial test series was conducted with saturated oxygen liquid and vapor at 0.6 MPa. The initial series was followed by tests where the test tank was pressurized with gaseous helium to 1.4 to 1.6 MPa. For these tests, the helium mole fraction in the ullage was quite high, about 0.57 to 0.62. TVS behavior is different when helium is present than when helium is absent. The tank pressure becomes the sum of the vapor pressure and the partial pressure of helium. Therefore, tank pressure depends not only on temperature, as is the case for a pure liquid-vapor system, but also on helium density (i.e., the mass of helium divided by the ullage volume). Thus, properly controlling TVS operation is more challenging with helium pressurization than without helium pressurization. When helium was present, the liquid temperature would rise with each successive TVS cycle if tank pressure was kept within a constant control band. Alternatively, if the liquid temperature was maintained within a constant TVS control band, the tank pressure would drop with each TVS cycle. The final test series, which was conducted with liquid nitrogen pressurized with helium, demonstrated simultaneous pressure and temperature control during TVS operation. The simultaneous control was achieved by systematic injection of additional helium during each TVS cycle. Adding helium maintained the helium partial pressure as the liquid volume decreased because of TVS operation. The TVS demonstrations with liquid oxygen pressurized with helium were conducted with three different fluid-mixer configurations-a submerged axial jet mixer, a pair of spray hoops in the tank ullage, and combined use of the axial jet and spray hoops. A submerged liquid pump and compact heat exchanger located inside the test tank were used with all the mixer configurations. The initial series without helium and the final series with liquid nitrogen both used the axial jet mixer. The axial jet configuration successfully demonstrated the ability to control tank pressure; but in the normal-gravity environment, the temperature in the upper tank region (ullage and unwetted wall) was not controlled. The spray hoops and axial jet combination also successfully demonstrated pressure control as well as temperature control of the entire tank and contents. The spray-hoops-only configuration was not expected to be a reliable means of tank mixing because there was no direct means to produce liquid circulation. However, surprisingly good results also were obtained with the sprayhoops- only configuration (i.e., performance metrics such as cycle-averaged vent flowrate were similar to those obtained with the other configurations). A simple thermodynamic model was developed that correctly predicted the TVS behavior (temperature rise or pressure drop per TVS cycle) when helium was present in the ullage. The model predictions were correlated over a range of input parameters. The correlations show that temperature rise or pressure drop per cycle was proportional to both helium mole fraction and tank heat input. The response also depended on the tank fill fraction: the temperature rise or pressure drop (per TVS cycle) increased as the ullage volume decreased.

Thermodynamic vent system↗

Two-Phase Cryogenic Heat Exchanger for the Thermodynamic Vent System

A two-phase cryogenic heat exchanger for a thermodynamic vent system was designed and analyzed, and the predicted performance was compared with test results. A method for determining the required size of the Joule-Thomson device was also developed. Numerous sensitivity studies were performed to show that the design was robust and possessed a comfortable capacity margin. The comparison with the test results showed very similar heat extraction performance for similar inlet conditions. It was also shown that estimates for Joule- Thomson device flow rates and exit quality can vary significantly and these need to be accommodated for with a robust system design.

Christie, Robert J.↗

Solid-State Thermodynamic Vent System for Control of Cryogenic Propellants

A Solid-State Thermodynamic Vent System (STVS) is a novel Cryogenic Fluid Management (CFM) technology for spacecraft cryogenic propellant tanks that may reduce boiloff while providing greater control over the propellent condition. By exploiting the vacuum-induced cryocooling potential of cryogen-saturated silica aerogel material, an internal STVS heat exchanger expels some sacrificial cryogenic propellant to the vacuum of space to produce cooling within the storage tank. This cooling is transferred directly to the stored fluid, thereby reducing boiloff and increasing hold times. The primary STVS project objective was to design and build a bespoke STVS heat exchanger that employed aerogel blanket material and perform a ground demonstration of the technology using liquid nitrogen (LN2) as the cryogenic propellant. This demonstration aimed to prove that an STVS can have a positive influence on the tank boiloff, shown through a reduction in mass flow rate out of the system during operation, and exercise control over the tank pressure. Testing proved the effectiveness of the concept by reducing the LN2 boiloff rate and tank pressure by roughly 70% and 77% respectively during a single pump-down cycle, which sacrificed around 1.8 kg of propellant.

Propellant Production↗

Polynomial coefficients of thermochemical data for the C-H-O-N system

Thermodynamic data are required input for the finite kinetics and equilibrium computer programs needed for modeling the combustion of hydrocarbons in the fields of energy and pollution research. Least squares determined coefficients of the curve-fitted thermodynamic data for 193 species in the C-H-O-N system are presented in card image form and are of suitable format for use by common computer programs.

Wakelyn, N. T.↗

Zero-G thermodynamic vent system for shuttle/Centaur

Viewgraphs are presented showing drawings of Centaur configurations, the Thermodynamic Vent System (TVS), the mixer pump, and the hydrogen vent motor pump inverter. A cryogenic performance summary is given in chart form. The TVS liquid flow operation and vapor flow operation are diagrammed.

Niggemann, Richard E.↗

Zero-G Thermodynamic Venting System (TVS) Performance Prediction Program

This report documents the Zero-g Thermodynamic Venting System (TVS) performance prediction computer program. The zero-g TVS is a device that destratifies and rejects environmentally induced zero-g thermal gradients in the LH2 storage transfer system. A recirculation pump and spray injection manifold recirculates liquid throughout the length of the tank thereby destratifying both the ullage gas and liquid bulk. Heat rejection is accomplished by the opening of the TVS control valve which allows a small flow rate to expand to a low pressure thereby producing a low temperature heat sink which is used to absorb heat from the recirculating liquid flow. The program was written in FORTRAN 77 language on the HP-9000 and IBM PC computers. It can be run on various platforms with a FORTRAN compiler.

Nguyen, Han↗

Testing of a Spray-bar Thermodynamic Vent System in Liquid Nitrogen

To support development of a microgravity pressure control capability for liquid oxygen, thermodynamic vent system (TVS) testing was conducted at Marshall Space Flight Center (MSFC) using liquid nitrogen (LN2) as a LOX simulant. The spray bar TVS hardware used was originally designed by the Boeing Company for testing in liquid hydrogen (LH2). With this concept, a small portion of the tank fluid is passed through a Joule-Thomson (J-T) device, and then through a longitudinal spray bar mixed-heat exchanger in order to cool the bulk fluid. To accommodate the larger mass flow rates associated with LN2, the TVS hardware was modified by replacing the recirculation pump with an LN2 compatible pump and replacing the J-T valve. The primary advantage of the spray-bar configuration is that tank pressure control can be achieved independent of liquid and vapor location, enhancing the applicability of ground test data to microgravity conditions. Performance testing revealed that the spray-bar TVS was effective in controlling tank pressure within a 6.89 kPa band for fill levels of 90%, 50%, and 25%. Tests were also conducted with gaseous helium (GHe) in the ullage. The TVS operated nominally with GHe in the ullage, with performance similar to the tests with gaseous nitrogen (GN2). Testing demonstrated that the spray-bar TVS design was flexible enough for use in two different propellants with minimal hardware modifications.

Flachbart, R. H.↗