Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Multiphysics modeling of printed surface acoustic wave thermometers

Surface acoustic wave (SAW) transducers are a class of sensors and actuators that operate on the fundamental principle of piezoelectricity. Aerosol jet printing and other additive manufacturing techniques have resulted in the low-cost fabrication of low-power and small-footprint SAW devices that are suitable for sensing in high-temperature and radioactive environments. In this work, we developed a series of temperature-dependent finite element models for a SAW transducer consisting of printed silver interdigitated transducers (IDTs) deposited onto piezoelectric lithium niobate. Modeling accuracy was evaluated experimentally from room temperature to 200 °C using an aerosol-jet-printed SAW thermometer. A time-domain study enabled visualization of the wave propagation and successfully guided the denoising of the scattering parameter measurement. Additionally, frequency-domain models using traditional modal analysis or the unique port boundary condition feature in COMSOL Multiphysics accurately predicted the temperature-driven natural frequency drift in the SAW thermometer. The finite element models developed in this study serve to facilitate the computer-aided design of future SAW transducers for applications in harsh environments.

47 OTHER INSTRUMENTATION↗

Developing compact tuning fork thermometers for sub-mK temperatures and high magnetic fields

There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. Here, we present the development of scalable thermometers based on quartz tuning fork resonators immersed in liquid 3 He and adapt hydrodynamic models to provide an improved description of temperature dependence in the high viscosity regime between 1 and 10mK. We demonstrate successful thermometer operation and discuss the feasibility of fast and compact thermal probes suitable for small samples.

47 OTHER INSTRUMENTATION↗

Nuclear temperature and its dependence on the source neutron-proton asymmetry deduced using the Albergo thermometer

Albergo thermometers with double isotope, isotone and isobar yield ratio pairs with one proton or/and neutron difference are investigated. Without any extra sequential decay correction, a real temperature value of 4.9 ± 0.5 MeV is deduced from the yields of the experimentally reconstructed primary hot intermediate mass fragments (IMFs) from 64 Zn + 112 Sn collisions at 40 MeV/nucleon using the Albergo thermometer for the first time. An experimental sequential decay correction from the apparent temperatures to the real ones for twelve other reaction systems with different neutron-proton (N/Z) asymmetries in the same experiment, 70 Zn, 64 Ni on 112,124 Sn, 58,64 Ni, 197 Au, 232 Th at 40 MeV/nucleon, is performed using an empirical correction factor approach of Tsang et al. with the deduced 4.9 MeV temperature value. The dependence of nuclear temperature on the source N/Z asymmetry is further investigated using these deduced real source temperature values from the present thirteen systems. It is found that the deduced real source temperatures at the present source N/Z range show a rather weak dependence on the source N/Z asymmetry. In conclusion, by comparison between our previous results and those from other independent experiments, a consistent description for the N/Z asymmetry dependence of nuclear temperature is addressed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared Thermometer Instrument Handbook

The infrared thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the brightness temperature of the scene in its field of view. The ground IRT (sometimes referred to as the upwelling instrument) lens has a wide field of view for measuring the radiating temperature of the ground surface. It measures in a narrow range of the infrared band, details of which can be found in Table 2. It provides data to the user averaged to 1-minute resolution. The infrared thermometer for sea-surface temperature (IRTSST) is a ship-based radiation pyrometer that provides measurements of the temperature of the sea surface. The upwelling infrared emission is determined with two different IRTs for over-ocean field campaigns and the data is at 1-second temporal resolution. The IRTs are mounted at heights varying between 2 and 42 m above the ground, oriented so the mounting platform and other human made objects are not in the field of view, and also to ensure that the ground and vegetation cover are representative of the local area. The Heitronics IRT is generally mounted inside a small enclosure, and the Apogee IRT is shielded by a cylindrical enclosure that is part of the design from the manufacturer.

47 OTHER INSTRUMENTATION↗

Calibration of a resistance thermometer down to 0.04 degrees K

Method for calibrating germanium-resistance thermometers in cryostats between 0.4 degrees K and 4 degrees K involves extrapolating the specific heat of a simple metal to low temperatures. This method is used when a magnetic thermometer is not available.

Culbert, H. V.↗

A valid Margules formulation for an asymmetric ternary solution - Revision of the olivine-ilmenite thermometer, with applications

A derivation of a valid asymmetric ternary Margules expression for the excess free energy is presented, and the olivine-ilmenite thermometer is revised accordingly. Although the effect on the thermometer is relatively small, the revision results in improved precision. Estimated temperatures of equilibration are presented for olivine and ilmenite from lunar and terrestrial rocks.

Andersen, D. J.↗

Two-Range Electrical Thermometer

Thermocouple and resistance thermometer expand thermometer scale. Switch thrown up to connect platinum resistance temperature detector or down to connect (platinum/rhodium)/platinum thermocouple to meter. Thermocouple integral part of platinum resistance temperature detector wiring.

Bridges, W. F.↗

Noncontacting Thermometer

Proposed laser/ultrasonic thermometer measures bulk and surface temperatures of part without physical contact. No sensors or wire connections needed on part, moving or stationary. Problems of bonding sensors, of mutal diffusion of materials between sensor and part, and of disturbances of fluid and heat flows by sensor avoided. Single thermometer used to measure many parts remotely.

Wyett, Lynn M.↗

Evaluation of industrial platinum resistance thermometers

The calibration and stability of four surface temperature measuring industrial platinum resistance thermometers for use in the temperature range -120 C to 160 C was investigated. It was found that the calibration formulation of the International Practical Temperature Scale of 1968 provided the most accurate calibration. It was also found that all the resistance thermometers suffered from varying degrees of instability and hysteresis.

Daryabeigi, Kamran↗

Progress in kinetic inductance thermometers for X-ray calorimeters

Conventional X-ray microcalorimeters have so far used ionimplanted resistors for thermometers. Recently, however, several new methods for sensing small temperature changes have been suggested that are nondissipative. Such devices may have intrinsically better energy resolution by eliminating the Johnson noise present in resistive devices. The use of kinetic inductance thermometers for X-ray microcalorimeters is being investigated. This technique exploits the strong temperature dependence of magnetic penetration depth of thin superconducting films. The prototype system, designed for operation at 1.5 K, uses films of aluminum and tin. Once the expected temperature sensitivity and alpha particle detection have been demonstrated, aluminum will be replaced with titanium or another material with a suitable critical temperature and the device will be operated at 0.3 K. At this temperature, the energy resolution from thermal noise should be sufficiently good to allow X-ray detection.

Rawley, G. L.↗

Germanium Resistance Thermometer For Subkelvin Temperatures

Improved germanium resistance thermometer measures temperatures as small as 0.01 K accurately. Design provides large area for electrical connections (to reduce electrical gradients and increase sensitivity to changes in temperatures) and large heat sink (to minimize resistance heating). Gold pads on top and bottom of germanium crystal distribute electrical current and flow of heat nearly uniformly across crystal. Less expensive than magnetic thermometers or superconducting quantum interference devices (SQUID's) otherwise used.

Castles, Stephen H.↗

Electrical Thermometers for Aircraft

Electrical thermometers commonly used on aircraft are the thermoelectric type for measuring engine-cylinder temperatures, the resistance type for measuring air temperatures, and the superheat meters of thermoelectric and resistance types for use on airships. These instruments are described and their advantages and disadvantages enumerated. Methods of testing these instruments and the performance to be expected from each are discussed. The field testing of engine-cylinder thermometers is treated in detail.

Peterson, John B↗

Evaluation of the Use of Optical Fiber Thermometers for Thermal Control of the Quench Module Insert

Issues regarding the use of optical fiber thermometers to control heater settings in a microgravity vacuum furnace are addressed. It is desirable to use these probes in environments such as the International Space Station, because they can be operated without re-calibration for extended periods. However, the analysis presented in this paper shows that temperature readings obtained using optical fiber thermometers are corrupted due to emissions from the fiber when extended portions of the probe are exposed to elevated temperatures.

Jones, Matthew R.↗

Evaluation of the Use of Optical Fiber Thermometers for Thermal Control of the Quench Module Insert

Issues regarding the use of optical fiber thermometers to control heater settings in a microgravity vacuum furnace are addressed. It is desirable to use these probes in environments such as the International Space Station, because they can be operated without re-calibration for extended periods. However, the analysis presented in this paper shows that temperature readings obtained using optical fiber thermometers can be corrupted by emissions from the fiber when extended portions of the probe are exposed to elevated temperatures.

Jones, Matthew R.↗

A PdMn Based High Resolution Thermometer for the Temperature Range of 0.7-1 K

Experiments Along the Coexistence near Tricriticality (EXACT) will test exact predictions made by Renormalization Group theory by mapping the phase diagram of liquid He-3 and He-4 mixtures at the tricritical point, Tcp=0.867 K. A PdMn based High Resolution Thermometer (HRT) will be utilized by EXACT to make accurate measurements with a resolution that has never been attained for the temperature range 0.7-1 K. The basic design of this mini high resolution thermometer comprises a sensing element whose magnetic susceptibility changes with temperature, a thermal connector, magnetic shielding, and some permanent magnets to apply a constant magnetic field. In this study, we will quantitatively determine the resolution of possible sensing element candidates of 0.15%, 0.20%, and 0.25% ppm Mn and compare them with an annealed group of PdMn with the corresponding concentrations to see how this processing technique affects sensitivity.

Koo, Peter K.↗

Correction for Self-Heating When Using Thermometers as Heaters in Precision Control Applications

In precision control applications, thermometers have temperature-dependent electrical resistance with germanium or other semiconductor material thermistors, diodes, metal film and wire, or carbon film resistors. Because resistance readout requires excitation current flowing through the sensor, there is always ohmic heating that leads to a temperature difference between the sensing element and the monitored object. In this work, a thermistor can be operated as a thermometer and a heater, simultaneously, by continuously measuring the excitation current and the corresponding voltage. This work involves a method of temperature readout where the temperature offset due to self-heating is subtracted exactly.

Ressler, Michael E.↗

Performance and Characterization of Magnetic Penetration Thermometer Devices for X-Ray Spectroscopy

We are developing magnetic penetration thermometers (MPTs) for applications in X-ray astronomy. These non-dissipative devices consist of an X-ray absorber in good thermal contact to a superconducting thin film with a transition temperature around T=100mK. A microfabricated superconducting planar inductor underneath is used to store a persistent current and couple the superconductor's diamagnetic response to a readout SQUID. The strong temperature dependence of the diamagnetic response make these devices suitable for highly sensitive macroscopic thermometers that are capable of achieving very high energy resolution. We present results achieved with MPTs consisting of MoAu bilayer sensors attached to overhanging square 250 micron by 250 micron gold absorbers that have demonstrated an energy resolution of delta E_FWHM=2.3eV at an X-ray energy of 5.9keV. A similar device has shown delta E_FWHM=2.0eV at 1.5 keV. Under certain conditions and for specific device geometries, the temperature responsivity of the MPTs can vary on long timescales degrading the spectral performance. We present the characterization of different inductor geometries to optimize the design for the highest possible temperature sensitivity and compare different device designs with respect to responsivity stability.

Porst, J. -P.↗